2009-110 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 ur.ID mTIFI .]AT E {JF C0MPLLA-NkC','E" Pernut Number: P20090110 Date Issued: Thursday, October 28, 2010 This is to certify that work requested to be done as shown by Permit Number P20090110 has been completed. Tax Map Number. 523400-309-009-0002-001-000-0000 Location: 200 LUZERNE Rd Owner. HOMESTEAD VILLAGE L P Applicant: HOMESTEAD VILLAGE L P This structure maybe occupied as a: Septic Alteration Commercial By Ch+rler of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090110 Application Number. A20090110 Tax Map No: 523400-309-009-0002-001-000-0000 Permission is herebygranted to: HOMESTEAD VILLAGE L P For properly located at: 200 LUZERNE Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: HOMESTEAD VILLAGE L P 4294 ROUTE 5 Septic Alteration Commercial CALEDONIA, NY 14423 Total value Contractor or Builder's Name/Address Electrical Inspection Agency SANITARY SEWER DAN DRELLOS PO BOX 224 GLENS FALLS NY Plans &Specifications 2009-110 178 & 179 Adirondack St - septic alteration commercial $35.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday, April 20, 2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the T�w"o ee ry 1 i t Apri120, 2009 w.ve� SIGNED BY " _ for the Town of Queensbury. Director of Building&Code Enforcement OFFICE USE ONLY__________________________% % 01 TA MAP NO. PER NO.67-11C PERMIT FEE. 'f CS 10 ; APPROVALS: ZONING TOWN CLERK 00 APPLICATION FOR SEPTIC DISPOSAL SYSTEM PERMIT: A PERMIT MU T BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJEC TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. �,, OWNER:H ��'¢ i 1/ INSTALLER: "7' ADDRESS: ,e 4 U E �� ADDRESS: P y 9 x z2 y PHONE NOS. 7 1`'-47 ` -i PHONE NOS. / 1 b — y OC-6 J LOCATION OF INSTALLATION: fl 7 9 l/ R/C4ClL 4-,�i-<"e NO.OF RESIDENCE INFORMATION: YEAR BUILT BEDROOMS X COMPUTATION= = TOTAL DAILY FLOW GARBAGE GRINDE 1980 or older X 150 gallon per bedroom INSTALLED?_ 1981 -1991 X 130 gallon per bedroom = SPA OR HOT TUB 1992-present X 110 gallon per bedroom INSTALLED? I" PARCEL INFORMATION: ✓ TOPOGRAPHY: Flat rolling r/ Steep slope %Slope ✓ SOIL NATURE: Sand Loam Clay Other ✓ GROUNDWATER: At what depth? ✓ BEDROCK/IMPERVIOUS MATERIAL: At what depth? ✓ DOMESTIC WATER SUPLY: Municipal Well (If well: Water supply from any septic system absorption is ft.) ✓ PERCOLATION TEST: Rate is per minute per inch. (Test to be completed by a licensed professional engineer or architect.) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect (unless installed in a Planning Board approved subdivision). TANK SIZE: a `� ✓ GALLON (MIN. SIZE IS 1,000 GAL.) Add 250 gallons to the size of the septic tank for each garbage grinder, spa or whirlpool tub. SYSTEM TYPE: ABSORPTION FIELD (WITH NO. 2 STONE) Total length �S7 ft. Each trench �� X Z! ❑ SEEPAGE PIT(S) (WITH NO. 3 STONE) How many? Size? ❑ ALTERNATIVE SYSTEM Bed or other type? ❑ HOLDING TANK SYSTEM Total required capacity? Tank size? Number of tanks? NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPP(TI=n Rv A Tn%Arkt Septic Inspection Repo Office No. (518) 761-8256 Date Ins on r u re iv Queensbury Building &Code Enforcement Arrive: %� m ,part: am/pm 742 Bay Rd., Quee`nsbury, NY 12804 Inspector's Initials: NAME: 1-t A tI t L P R NO.: LOCATION: 1_ ECT ON: RECHECK: �E Comments and/or diagram Soil Type: Sand Loam Clay Type of Water: Municipal Well Water Waterline separation distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/ - Y N N/A 150'to well required if NO Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field Pit Opening Sealed: Y N End Cap Y N Inlet/Outlet Pipes&Baffles Y N Manholes 12"or less below grade Y_N [provide extension collar if Yes Y N Location Separations Foundation to tank ft. Foundation to absorption ft. Separation of Pits Aft. Conforms as per Plot Plan N Engineer Report and As-Built Y N ETU Maintenance Contract Y_ N provided Location of System on Property: Front Re r Left Side Right Side Middle Front Middle Rear st m Use S Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Forms\Inspection Forms\Septic Inspection Report-03 2910.doc o �IIIIIIIIIII� IIIIIIIIIIII ENVIRONMENTAL DESIGN PARTNERSHIP,LLP October 19, 2010 Queensbury Building & Code Enforcement 742 Bay Road Queensbury,NY 12804 Attn: John O'Brien Re: Homestead Village Mobile Home Park Lot 178/179 Adirondack Dear John: On October 13, 2010 I visited above referenced Homestead Village Mobile Home Park lots. The purpose of this visit was to observe the installation of the new septic system designed by EDP dated May 30, 2008. Based on my review of the plans and observation of the installation it is my opinion that the installation of the system is in compliance with the intent of the design plans. I would note that the positioning of the two septic tanks were modified from that indicated on the original plan. Enclosed with this letter is a revised plan (2 copies) which reflects the `as-built' condition. Please contact me should you have any questions regarding this system. Sincerely, Dennis MacElroy, PE Enclosure cc: Homestead Trailer Park AS BUILT' 900 Route 146,Clifton Park, New York 12065 phone(518)371-7621 -fax(518)371-9540 Septic Inspection Report Office No. (518) 761-8256 Date Ins n iv Queensbury Building&Code Enforcement Arrive: rt: _. _n 742 Bay Rd., Queensbury, NY 12804 Inspector's In NAME: ' IT NO.: LOCATION: SPECT ON: _�1 RECHECK: Comments and/or diagram Soil Ty Sa Loam Clay Type of Water• Well Water Wa ration distance ft. Well separation distance ft. Other wells: ft. Well Casing Length 50' +/- Y N N/A 150'to well required If NO Absorption Field: Total length Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank �Vt. F Tank to Distribution Box Distribution Box to Field Pit Ir Opening Sealed: Vft N End Cap N Inlet/Outlet Pipes&Baffles N. Manholes 12"or less below grade Y_ 1p Y N Location Separations zi Foundation to tank ft. Foundation to absorption 1A ft. Separation of Pits ft. Conforms as per Plot Plan Y Engineer Report and As-Built Y N ETU Maintenance Contract Y_N provided Location of System on Property: Front Rear Left Side Right Side Middle Front Middle Rear System Use Status• Approved Partial Approved and needs to be re-Inspected, please call the Building&Codes Office Disapproved L:\Pam Whiting\2010\Building Codes Farms\Inspectlon Forms\Septic Inspection Repoi#_03 2910.doc INSPECTION REQUIREMENTS: BORING AND PERCOLATION TEST: ENGINEER OF RECORD TO INSPECT TRENCHES PRIOR TO BACKFILLING. ASSUMED CONDITION BASED ON SITE EVALUATION 0-5' MEDIUM FINE SAND NO WATER OR MOTTLING NO TE: 1) BASEMAP INFORMATION OBTAINED FROM PUBLICALLY AVAILABLE PERCOLATION RATE APPROXIMATELY ONE MINUTE RESOURCES AND DOES NOT REPRESENT AN ACTUAL FIELD NOTE: SOIL CONDITIONS TO BE CONFIRMED BY P.E. PRIOR TO BACKFILLING SYSTEM. INSTRUMENT SURVEY SEPTIC DESIGN : APPLICATION RATE = 1 .2 GAL./SF/DAY LOT 178 3 BEDROOMS AT 100 GALLONS/BEDROOM =300 GALLONS /VpR7-H LOT 179 3 BEDROOMS AT 100 GALLONS/BEDROOM =300 GALLONS TOTAL 6 BEDROOMS AT 100 GALLONS/BEDROOM (2) AS—BUILT 1,000 = 600 GALLONS GALLON SEPTIC TANKS USE 1250 GALLON PRECAST TANK USE 5 LINES AT 50 FT. EACH (SPACED 6 FT. ON-CENTER) AS—BUILT 4" PVC AS—BUILT 4" PVC SCH 40 AT 2% MIN. SCH 40 AT 2% MIN. CONSTRUCTION NOTES: 1) CONSTRUCTION OF ABSORPTION FACILITIES SHALL NOT OCCUR WHEN THE GROUND /S FROZEN OR THE SOIL MOISTURE CONTENT IS HIGH. IF A FRAGMENT OF SOIL FROM APPROXIMATELY NINE INCHES 15. BELOW THE SURFACE CAN EASILY BE ROLLED INTO A RIBBON INSTEAD OF CRUMBLING, THE 4' 25.7" �6.5 MOISTURE CONTENT IS TOO HIGH FOR CONSTRUCTION PURPOSES. OBVIOUSLY, SOME SILT OR CLAY MUST BE PRESENT FOR A RIBBON TO BE FORMED. r PROPOSED WYE AND 4" PVC SDR 2) TRENCH LOCATIONS AND DEPTHS SHOULD BE MARKED BY STAKES BEFORE TRENCHES ARE I —35 (GASKETED BELL) AT 175 MIN. EXCAVATED. THE NATURAL SURFACE SHALL NOT BE SIGNIFICANTLY DISTURBED. IF THE SITE IS REGRADED OR SIMILARLY DISTURBED, THE SOIL SHALL BE ALLOWED TO STABILIZE (I.E., SETTLE NATURALLY FOR A PERIOD OF AT LEAST SIX MONTHS, INCLUDING AT LEAST ONE FREEZE—THAW e CYCLE) AND NEW PERCOLATION AND DEEP HOLE TESTS CONDUCTED. HEAVY EQUIPMENT USE IN THE EXISTING DESIGNATED ABSORPTION SYSTEM AREA SHOULD BE MINIMIZED TO PREVENT SOIL PERMEABILITY MOBILE I I I I I REDUCTION DUE TO COMPACTION PLUS POSSIBLE TRENCH CAVE—IN AND DISTRIBUTION PIPE HOME I I I I MISALIGNMENT/BREAKAGE. AS—I I I I BUILTEXI 3) AFTER A FINAL GRADE CHECK, TRENCH EXCAVATION MAY BEGIN. TRENCH DEPTH SHALL BE AS I I I I I MOBILE SHALLOW NG DISTRIBUTION BOX #2 SHALLOW AS POSSIBLE, BUT NOT LESS THAN 18 INCHES. TRENCHES SHALL BE EXCAVATED TO HOME DESIGN DEPTH WITH BOTTOMS PRACTICALLY LEVEL. F 4) FOLLOWING EXCAVATION, THE TRENCH BOTTOMS SHOULD BE GRADED BY HAND. THE BOTTOMS OF THE TRENCHES SHOULD BE CHECKED BY A TRANSIT, ENGINEER'S LEVEL, OR CARPENTER'S LEVEL TO LOT 180 LOT 179 I I I I I ASSURE THAT EACH /S PRACTICALLY LEVEL. TRENCH BOTTOMS AND S/DEWALLS SHOULD BE LOT 178 LOT 177 IMMEDIA TEL Y RAKED AFTER FINAL GRADING AND AT LEAST SIX INCHES OF AGGREGATE PLACED /N THE TRENCHES. 5) GRAVITY DISTRIBUTOR PIPE SHALL BE CAREFULLY INSTALLED AT A SLOPE OF �6 TO Y32 INCH PER 4 I FOOT. PRESSURE OR DOSED DISTRIBUTOR PIPE SHALL BE INSTALLED LEVEL. GRADES SHALL BE �— —L DETERMINED BY AN ENGINEER'S LEVEL, TRANSIT OR CARPENTER'S LEVEL. AN EASY METHOD OF MEASURING THE '6 INCH PER FOOT SLOPE FOR DISTRIBUTOR PIPE IS TO TAPE A Y4 INCH BLOCK TO ONE END OF A STRAIGHT FOUR FOOT BOARD. BY PLACING THE BLOCKED END WITH THE BLOCK FACING DOWN ON THE DOWNSTREAM TOP OF THE DISTRIBUTOR PIPE, A CARPENTER'S LEVEL CAN BE USED TO DETERMINE THE %6 INCH PER FOOT SLOPE. A Ya INCH BLOCK SIMILARLY USED WOULD AS—BUILT RESULT IN A Y32 INCH PER FOOT SLOPE. ANOTHER METHOD USED TO ESTABLISH THE GRADE OF DISTRIBUTOR PIPE IS BY BATTER BOARDS. AGGREGATE SHALL BE INSTALLED IN THE TRENCHES TO ABSORPTION FIELD A DEPTH OF AT LEAST TWO INCHES ABOVE THE TOP OF THE DISTRIBUTOR PIPES. ADDITIONAL 5 LINES AT 50 FT. AGGREGATE MAY BE REQUIRED TO BRING THE TOP OF THE AGGREGATE TO WITHIN SIX TO 12 INCHES EACH TO SERVICE OF FINAL GRADE. BOTH LOTS 178 & 179 6) AFTER THE UPPER AGGREGATE IS PLACED IN THE TRENCHES, THE GEOTEXTILE, UNTREATED BUILDING PARKING 3 3 PARKING AREA AREA PAPER, HAY OR STRAW IS TO BE IMMEDIATELY INSTALLED ON THE AGGREGATE AND THE TRENCH BACKF/LLED WITH EXCAVATED SOIL. IF THE TRENCHES CANNOT BE IMMEDIATELY BACKFILLED, THE TRENCHES SHOULD BE TEMPORARILY COVERED WITH AN IMPERVIOUS MATERIAL, SUCH AS TREATED BUILDING PAPER TO PREVENT SIDEWALL COLLAPSE AND SILTATION INTO THE AGGREGATE. 7) THE EARTH BACKFILL IS TO BE MOUNDED SLIGHTLY ABOVE THE ORIGINAL GROUND LEVEL (I.E., NOT CO PLCTED) TO ALLOW FOR SETTLING. FOLLOWING SETTLEMENT, THE ENTIRE AREA SHOULD BE E.o.P. ADED WITHOUT THE USE OF HEAVY EQUIPMENT AND SEEDED WITH GRASS. HEAVY EQUIPMENT ALL NOT ENTER THE ABSORPTION FACILITY AREA OR THE PROPOSED EXPANSION AREA AFTER THE BSCPPFACE SEWAGE TREATMENT SYSTEM HAS BEEN CONSTRUCTED. A DI RONDA CK STREET IMU HORIZONTAL SEPARATION OF 10 FEET SHOULD EXIST BETWEEN THE HOUSE SEWER AND Y WATERLINE. LINES WHERE LINES MUST CROSS, THE WATER SERVICE LINE SHALL BE AT LEAST 12 r NCHES ABOVE THE HOUSE SEWER. IF A WATER LINE MUST PASS BELOW THE HOUSE SEWER, THE �fy 1(ERT/CAL SEPARATION MUST BE AT LEAST 18 INCHES. ROOF, FOOTING, GARAGE, CELLAR AND SURFACE WATER DRAINAGE MUST BE EXCLUDED FROM THE SYSTEM. WATER SOFTENER, WATER RECHARGE AND BACKWASH WASTES NORMALLY ARE NOT TO BE DISCHARGED TO THE SYSTEM UNLESS A SEPARATE SUBSURFACE DISCHARGE TO AN AREA 250 FEET FROM WELLS OR WATER COURSES IS UNAVAILABLE. n A S—BUI L T SEPTIC REHA BILI TA TION PREPARED FOR LOT 178 & 179 ADIRONDACK STREET EXISTING SANITARY STRUCTURES HOMES TEA D VlL L A GE INCLUDING SEPTIC TANK AND SEEPAGE DEVICES ARE TO BE CRUSHED IN PLACE > > AND FILLED WITH NATIVE MATERIAL. AS ILT TOWN OF QUEENSBUR Y WARREN COUNTY, NEW YORK SCALE: 1 " = 20' OCTOBER 18, 2010 NOTE: ENVIRONMENTAL DESIGN PARTNERSHIP, LLP 900 ROUTE 146 CLIFTON PARK, N.Y. 12065 (518) 371-7621 MOBILE HOME UNITS TO BE PLACED WITH A MINIMUM 10 FT. HORIZONTAL SEPARATION. ENGINEERING LANDSCAPE ARCHITECTURE LAND SURVEYING JAMES E. MI TCHELL P.E. 530 337