inspectionsINSPECTION WORKSHEET (FIST-001459-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0395-2018 Case Module:Permit Inspection Date:Mon Mar 18, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Firestopping Job Address:Parcel Number:147 Chestnut Ridge RD Queensbury, NY 12804 290.-1-22.8 Contact Type Company Name Name Granted Permission Rhein, George Engineer Scharff, Michael Contractor Rhein, George Applicant Rhein, George Primary Owner Rhein, George Checklist Item Passed Comments Building Inspector Notes NO 1/7/19 Firestopping Partial Approval - Firestopped two truss area dead spaces to create areas smaller than 32 sf at bonus room. No access required in these two areas. 3/11/19 fire stopping for vertical penetrations approved for first floor and bonus room only. Basement not completed. 3/18/19 fire stopping in basement approved for vertical penetrations Fire separation 1, 2, 3 hour NO Fire wall 2, 3, 4 hour NO Fireproofing NO Mar 18, 2019 Page (1) INSPECTION WORKSHEET (FIST-001459-2019) Checklist Item Passed Comments Firestopping NO 1/7/19 Firestopping Partial Approval - Firestopped two truss area dead spaces to create areas smaller than 32 sf at bonus room. No access required in these two areas. Penetration sealed YES 3/11/19 fire stopping for vertical penetrations approved for first floor and bonus room only. Basement not completed3/18/19 fire stopping in basement approved for vertical penetrations 16 inch insulation in cavity min.NO Garage Fire Separation NO House side ½ inch or 58 inch Type X NO Garage side 5/8 inch Type X NO Ceilingwall NO Mar 18, 2019 Page (2) Smith, Mark (Inspector) INSPECTION WORKSHEET (BINS-001460-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0395-2018 Case Module:Permit Inspection Date:Mon Mar 18, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Building Insulation Job Address:Parcel Number:147 Chestnut Ridge RD Queensbury, NY 12804 290.-1-22.8 Contact Type Company Name Name Applicant Rhein, George Contractor Rhein, George Primary Owner Rhein, George Granted Permission Rhein, George Engineer Scharff, Michael Checklist Item Passed Comments Building Inspector Notes NO 1/7/19 Insulation Partial Approval - R19 Exterior wall of fireplace chase. 3/18/19 insulation on first floor walls and bonus room ceiling approved. Ceilings on main level not insulated at this time. Knee walls in bonus room not insulated. Closed cell spray foam in walls and bonus room ceiling Basement insulation approved. R 21 in cavities with foam insulation over foundation. Provide documents from installer stating R value and thickness of insulation. U Factors = .3 cfm for windows, .5 cfm for doors NO Tyvek or Similar Exterior Sealant YES Zip system used Mar 18, 2019 Page (1) INSPECTION WORKSHEET (BINS-001460-2019) Checklist Item Passed Comments Proper Vent, Attic Vent NO Insulation Residential Check Commercial Check NO 1/7/19 Insulation Partial Approval - R19 Exterior wall of fireplace chase. Blower Door Test NO Combustion Air Supply for Furnace NO Fresh air supply 3' from grade NO Duct Insulation - if required in unheated spaces NO Tub Shower R-20 with Vapor Barrier NO Air Barrier behind Knee Walls NO All Ductwork Sealed Return and Supply NO Duct Blaster Test for duct work, R-8 NO All Return Air Hard Duct Work NO House Wrap Taped at all Seams NO Mar 18, 2019 Page (2) Smith, Mark (Inspector) INSPECTION WORKSHEET (RPLUM-001341-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0395-2018 Case Module:Permit Inspection Date:Fri Mar 8, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Rough Plumbing Job Address:Parcel Number:147 Chestnut Ridge RD Queensbury, NY 12804 290.-1-22.8 Contact Type Company Name Name Granted Permission Rhein, George Contractor Rhein, George Primary Owner Rhein, George Engineer Scharff, Michael Applicant Rhein, George Checklist Item Passed Comments Building Inspector Notes NO 3/8/19 rough plumbing approved inspection for supply and sanitary drain lines only. Items remaining Air pressure test for gas lines Air pressure test for radiant heat in floor. Plumbing Under Slab NO Rough Plumbing / Nail Plates YES Plumbing Vent Vents in Place YES 3" Vent Through Roof YES Verified glue joint above ball stop at roof penetration Mar 08, 2019 Page (1) INSPECTION WORKSHEET (RPLUM-001341-2019) Checklist Item Passed Comments 1 ½ inch minimum Drain Size YES Shower liner test (2" of water)NO Washing Machine Drain 2 inch minimum YES Washing Machine Trap: 18"-24" discharge YES Cleanout every 100 feet change of direction YES Pressure Test NO Drain Vent NO Air Head YES 5 psi or 10 ft. above highest conn. for 15 minutes YES Holding 5 psi for fifteen minutes Pressure Test YES Holding 5 psi for fifteen minutes Water Supply Piping YES Air Head YES 50 P.S.I for 15 minutes YES Holding 60 psi for 15 minutes Air Test Gas Piping 10 psi for 10 Minutes NO Gas piping not ready All Return Air Hard Duct Work NO Duct Insulation - if required in unheated spaces NO Mar 08, 2019 Page (2) INSPECTION WORKSHEET (RPLUM-001341-2019) Checklist Item Passed Comments Duct Testing Outside Conditioned Space NO Duct work sealed properly NO Mar 08, 2019 Page (3) Smith, Mark (Inspector) INSPECTION WORKSHEET (RPLUM-001359-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0395-2018 Case Module:Permit Inspection Date:Mon Mar 11, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Rough Plumbing Job Address:Parcel Number:147 Chestnut Ridge RD Queensbury, NY 12804 290.-1-22.8 Contact Type Company Name Name Contractor Rhein, George Granted Permission Rhein, George Engineer Scharff, Michael Primary Owner Rhein, George Applicant Rhein, George Checklist Item Passed Comments Building Inspector Notes NO 3/8/19 rough plumbing approved inspection for supply and sanitary drain lines only. Items remaining Air pressure test for gas lines Air pressure test for radiant heat in floor. 3/11/19 air test for gas piping approved. Holding 10 PSI for ten minutes Call when radiant heat is ready for inspection. Plumbing Under Slab NO 3" Vent Through Roof YES Verified glue joint above ball stop at roof penetration Shower liner test (2" of water)NO Mar 11, 2019 Page (1) INSPECTION WORKSHEET (RPLUM-001359-2019) Checklist Item Passed Comments Drain Vent NO 5 psi or 10 ft. above highest conn. for 15 minutes YES Holding 5 psi for fifteen minutes Pressure Test YES Holding 5 psi for fifteen minutes 50 P.S.I for 15 minutes YES Holding 60 psi for 15 minutes Air Test Gas Piping 10 psi for 10 Minutes YES Gas piping not ready 3/11/19 air test for gas piping approved. Holding 10 PSI for ten minutes Duct Insulation - if required in unheated spaces NO Duct Testing Outside Conditioned Space NO Mar 11, 2019 Page (2) Smith, Mark (Inspector) INSPECTION WORKSHEET (FIST-001379-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0395-2018 Case Module:Permit Inspection Date:Mon Mar 11, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Firestopping Job Address:Parcel Number:147 Chestnut Ridge RD Queensbury, NY 12804 290.-1-22.8 Contact Type Company Name Name Contractor Rhein, George Granted Permission Rhein, George Engineer Scharff, Michael Primary Owner Rhein, George Applicant Rhein, George Checklist Item Passed Comments Building Inspector Notes NO 1/7/19 Firestopping Partial Approval - Firestopped two truss area dead spaces to create areas smaller than 32 sf at bonus room. No access required in these two areas. 3/11/19 fire stopping for vertical penetrations approved for first floor and bonus room only. Basement not completed. Fire separation 1, 2, 3 hour NO Fire wall 2, 3, 4 hour NO Fireproofing NO Mar 11, 2019 Page (1) INSPECTION WORKSHEET (FIST-001379-2019) Checklist Item Passed Comments Firestopping NO 1/7/19 Firestopping Partial Approval - Firestopped two truss area dead spaces to create areas smaller than 32 sf at bonus room. No access required in these two areas. Penetration sealed YES 3/11/19 fire stopping for vertical penetrations approved for first floor and bonus room only. Basement not completed 16 inch insulation in cavity min.NO Garage Fire Separation NO House side ½ inch or 58 inch Type X NO Garage side 5/8 inch Type X NO Ceilingwall NO Mar 11, 2019 Page (2) Smith, Mark (Inspector) INSPECTION WORKSHEET (FIST-000101-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal RC-0395-2018Permit Case Number:Case Module: Mon Jan 7, 2019Partial Pass Inspection Date:Inspection Status: John O'BrienFirestopping Inspector:Inspection Type: 147 Chestnut Ridge RD290.-1-22.8 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName Granted PermissionRhein, George Primary OwnerRhein, George EngineerScharff, Michael ContractorRhein, George ApplicantRhein, George Checklist ItemPassedComments Building Inspector NotesNO1/7/19 Firestopping Partial Approval - Firestopped two truss area dead spaces to create areas smaller than 32 sf at bonus room. No access required in these two areas. Fire separation 1, 2, 3 hourNO Fire wall 2, 3, 4 hourNO FireproofingNO FirestoppingNO1/7/19 Firestopping Partial Approval - Firestopped two truss area dead spaces to create areas smaller than 32 sf at bonus room. No access required in these two areas. Jan 07, 2019Page (1) INSPECTION WORKSHEET (FIST-000101-2019) Checklist ItemPassedComments Penetration sealedNO 16 inch insulation in cavity min.NO Garage Fire SeparationNO House side ½ inch or 58 inch Type XNO Garage side 5/8 inch Type XNO CeilingwallNO O'Brien, John (Inspector) Jan 07, 2019Page (2) INSPECTION WORKSHEET (BINS-000102-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal RC-0395-2018Permit Case Number:Case Module: Mon Jan 7, 2019Partial Pass Inspection Date:Inspection Status: John O'BrienBuilding Insulation Inspector:Inspection Type: 147 Chestnut Ridge RD290.-1-22.8 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName ContractorRhein, George Granted PermissionRhein, George EngineerScharff, Michael ApplicantRhein, George Primary OwnerRhein, George Checklist ItemPassedComments Building Inspector NotesNO1/7/19 Insulation Partial Approval - R19 Exterior wall of fireplace chase. Window SealingNO U Factors = .3 cfm for windows, .5 cfm for doorsNO Tyvek or Similar Exterior SealantNO Proper Vent, Attic VentNO Insulation Residential Check Commercial CheckNO1/7/19 Insulation Partial Approval - R19 Exterior wall of fireplace chase. Jan 07, 2019Page (1) INSPECTION WORKSHEET (BINS-000102-2019) Checklist ItemPassedComments Blower Door TestNO Combustion Air Supply for FurnaceNO Fresh air supply 3' from gradeNO Duct Insulation - if required in unheated spacesNO Door / Window Sealed (No Insulation)NO Air Barrier behind Knee WallsNO Tub Shower R-20 with Vapor BarrierNO All Ductwork Sealed Return and SupplyNO Duct Blaster Test for duct work, R-8NO All Return Air Hard Duct WorkNO House Wrap Taped at all SeamsNO O'Brien, John (Inspector) Jan 07, 2019Page (2)