Loading...
RC-0412-2018 TOWNOFQUEEN SBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development - Building& Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-0412-2018 Date Issued: Monday, October 22, 2018 This is to certify that work requested to be done as shown by Permit Number RC-0412-2018 has been completed. Tax Map Number: 295.20-1-4.12 Location: 211 FARR LN Owner: Robin Shirley Applicant: Fan Construction This structure may be occupied as a: Residential Addition 227.5 s.f. By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the 4 property owner of the responsibility for compliance with Site Plan, 44t Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. Y �� TOWN OF QUEENSBURY i "'- i` j' 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 . ' P .-=- Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-0412-2018 Tax Map No: 295.20-1-4.12 Permission is hereby granted to: Farr Construction For property located at: 211 FARR LN In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Robin Shirley Single Family-Addition $19,500.00 Owner Address: 211 Farr LN Total Value $19,500.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Farr Construction 4 STONEHURST DR Queensbury,NY 12804 Plans&Specifications Residential Addition 227.5 s.f. $ 250.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday, July 24,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town u sbury; Tu<_sf ayii 4,2018 41 SIGNED BY: f `. \ for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only )t 'I ADDITION/ALTERATION PERMIT Permit#: APPLICATION Permit Fee:$, r Ck Town of CLucensbury F 742 Bay Road,queensbury,NY 12804 Invoice#: 0 91 P:518-761-8256 www.queensburv.net Project Location: all/ Farr e #: oqq.5 d-0 —I -Lk f Subdivision Name: � L. �`� 'i Tax Map I� �y� rQ�A �f ems.--.���^^ 'V of r!f�l\r 4 < ��\��rj CONTACT INFORMATION: bN y )'}i�� •O2MM N®DE 0• Applicant: ENT Name(s): &RAY--rs.�yv✓r— �, a 7 r Mailing Address, C/S/Z: 1s/ S' i--,bf 5I..0 D ( eee5©I4,'-/de Cell Phone: (57r ) 7/ -7444 Land Line: (c''If ) 7I/ -Czair Email: ti +r Sfdri4O`i al3 ✓ Ono`/ • Primar Owner(s): Name(s): Shot/ Mailing Address, C/S/Z: // Pm.- v' �2--- Cell Phone: ('Ti ' ) Land Line: (cf.q' ) 71,7 a75-Y Email: C4\ - ( • Contractor(s): Business Name: 1 , G��►.S-Er�it� ^ Contact Name(s): (' i4;-c_ ,�i ►� ,./ Mailing Address, C/S/Z: Sti/64116fOr: //4-01,►14Cfr .. ` ^ l 91 Cell Phone: ( i ) 7g, `''e.I Land Line: (67( ( ) 7 -- 5-' ur Email: ArY"G/7/S coot', eve • Architect(s)/Engineer(s): Business Name: Contact Name(s): Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( ) Email: Contact Person for Building & Code Compliance: 73r,PGfi -FA-r-- Cell Phone: (6'i'6 ) 7'7 -766 Land Line: ( ) Email: • • Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 f PROJECT INFORMATION: TYPE: Commercial f/ Residential WORK CLASS: ti Single-Family Two-Family _Multi-Family (#of units Townhouse Business Office Retail Industrial/Warehouse Garage (#of cars ) _Other (describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 07d275 I h 12171 1st floor: 2nd floor: 2nd floor: 3rd floor: 3rd floor: Basement (habitable space): Basement (habitable space): Total square feet: PP 5 Total square feet: • ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 1°l �v�•Pb/ 2. If Commercial project, what is the proposed use: 3. Source of Heat (circle one): Ga' Oil Propane Solar Other Fireplaces need a separate uel Burning Appliances & Chimney Application 4. Are there any structures not shown on the plot plan? YES69, Explain: 5. Are there any easements on the property? YES C/ 6. SITE INFORMATION: 7.a� a. What is the dimensions or acreage of the parcel? C1 3,�� b. Is this a corner lot? YES c. Will the grade be changed as a result o e construction? YES 0 d. What is the water source? PUBLIC) PRIVATE WELL e. Is the parcel on SEWER or a PRIVATE SEPTICystem? • Town of Queensbury Building_&Code Enforcement Addition/Alteration Application Revised March 2018 ``ma�yy;; R` 1. I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. • 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I.certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4, I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: • PRINT NAME: (,/,G1 z /%-rr SIGNATURE: '��� � � DATE: sa2,'/K • • Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 r/ FARI?sf2.24,5.reilAiNT 4w Clal, F- 4`.5...00E _�• - IN Yiu-.. ,� ?f '- —.."._.. B °d�J 0a f PERMI PLAT CLAN I HAVE PERSONALL MEASUR E-FIE` ®a PRFROM PRO OSE TR GTUR (S)OR SIGN(S) " --° 0 1� r Si NATURE { DATE ��"$$ C _< f _ F m al ' I S ! ! a'Q X 1 4 it I1F a2. t. I . �^+,,,is 4 �' s• ..------ zSS'wRf'.?_L 1•' .- j� 4 . N 0 i ,,,..,f t N P La .' a -.- _ - `�`t I i CO < li R ?1/4) C.? .1q,44.3j . � ... ,�' mot' `� Sl n #" sds,�-,, E f \17 A`" pay i • . ' . [JlEcEilvE5 REScheck Software Version 4.6.4 . • JUL 1 7 2018 i .c.11, Compliance Certificate TOWN OF QUEENSBURY COMMUNITY ITY DEVELOPMENT Project RC-0412-2018 295.20-1-4.12 Energy Code: 2015 IECC Shirley, Robin Location: Glens Falls, New York Construction Type: Single-family _ 211 Farr Lane 227.5 s.f. Project Type: Addition Residential Addition Climate Zone: 6 (7635 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Compliance:Passes using UA trade-off Compliance: 8.6%Better Than Code Maximum UA: 35 Your UA: 32 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor U Perimeter R-Value R-Value Ceiling 1:Cathedral Ceiling 228 49.0 0.0 0.022 5 Skylight 1:Wood Frame:Double Pane with Low-E 19 0.420 8 Wall 1:Wood Frame,16"o.c. 27 21.0 0.0 0.057 0 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 24 0.290 7 Basement Wail 1:Solid Concrete or Masonry 244 0.0 15.0 0.051 12 Wall height: 8.0' Depth below grade:5.5' - Insulation depth:8,0' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other - calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements-in REScheck Version 4.6.4 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. troL Fil"------ ‘-40.11. Name-Title Signat re Date HECEOVIE, {) szTh ilp.--,--',. , JUN 2 8 2018 -,._. , ttr., A ,,,,, Jr k TOWN OF QUEENSBURY }. t, .Z ,y BUILDING&CODES .._' . ti '`'', u r, T0. Project Title: Report date: 06/10/18 Data filename: Untitled.rck Page 1 of 9 0 REScheck Software VersionChecklist 4.6.4 Energy Code: 2015 IECC , Requirements: 0.0%were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen.For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions &Req.lD 103.1, Construction drawings and 'DComplies 103.2 .documentation demonstrate ;DDoes Not [PR1]1 energy code compliance for the 1ONot Observable building envelope.Thermal envelope represented on DNot Applicable construction documents. 103.1, Construction drawings and • DComplies 103.2, documentation demonstrate ;DDoes Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. DNot Observable Systems serving multiple DNot Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, !Heating and cooling equipment is: Heating: ; Heating: DComplies 403.7 sized per ACCA Manual S based Btu/hr : Btu/hr DDoes Not [PR2]z on loads calculated per ACCA Cooling: ; Cooling: DNot Observable 414, Manual)or other methods Btu/hr Btu/hr approved by the code official. gDNot Applicable • Additional Comments/Assumptions: i • • 1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/10/18 Data filename: Untitled.rck Page 2 of 9 ♦ S Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions &Req-10 402.1.1 Conditioned basement wall R-4,1 R- ;DComplies ;See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R_ R- DDoes Not table for values. insulation is used,verification [:-_Not Observable may need to occur during Insulation Inspection. Not 1]Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ,'OComplies [F05]1 insulation installed per DDoes Not manufacturer's instructions. pNot Observable CDNot Applicable 402.2.9 Conditioned basement wall 04 ft ft DComplies t e the for Envelope Assemblies es. [F06]1 insulation depth of burial or DDoes Not distance from top of wall. pNot Observable ❑Not Applicable 303.2.1 A protective covering is installed iOComplies [F011]2 ;to protect exposed exterior DDoes Not insulation and extends a pNot Observable minimum of 6 in.below grade. DNot Applicable 403.9 !Snow-and ice-melting system ! DComplies [F012]2 controls installed. ;0Does Not ; , ![]Not Observable 'ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/10/18 Data filename: Untitled.rck Page 3 of 9 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions &Req.ID 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies 'See the Envelope Assemblies 402.3.1, average). ;DDoes Not ;table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 IONot Applicable [FR2]1 303.1.3 "U-factors of fenestration products I❑Complies [FR4]1 are determined in accordance ❑Does Not -with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.1.1, `SkylightU-factor. U- U- ;[Complies See the Envelope Assemblies - 402.3.3, ^❑Does Not table for values. 402.3.6, i 402.5 ❑Not Observable [FR5]1 ❑Not Applicable 402.4.1.1 :Air barrier and thermal barrier 'OComplies [FR23]1 installed per manufacturer's ❑Does Not ++ `instructions. ;❑Not Observable :❑Not Applicable 402.4.3 i Fenestration that is not site built ;DComplies [FR2011 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440; Not Observable • or has infiltration rates per NFRC ; 400 that do not exceed code '❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures' ❑Complies [FR16]2 ,sealed at housing/interior finish 'ODoes Not and labeled to indicate s2.0 cfm leakage at 75 Pa. ❑Not Observable ❑Not Applicable 403.2.1 !Supply and return ducts in attics ' ICDComplies [FR12]1 insulated>=R-8 where duct is i ❑Does Not >=3 inches in diameter and>= ALP R-6 where<3 inches.Supply and, ,❑Not Observable .' `return ducts in other portions of i ❑Not Applicable the building insulated>=R-6 for `diameter>=3 inches and R-4.2 for<3 inches in diameter. 403.3.3.5 ,Building cavities are not used as : '❑Complies [FR1S]3 ,ducts or plenums. ❑Does Not 414, iQNot Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- - ❑Complies [FR17]2 above 105 sF or chilled fluids a DDoes Not below 55 QF are insulated to aR- ONot Observable ;❑Not Applicable 403.4.1 Protection of insulation on HVAC :❑Complies [FR24)1 piping. Does Not QNot Observable '❑Not Applicable 403.5,3 Hot water pipes are insulated to R- ' R- ❑Complies [FR18)2 '_.R-3. ❑Does Not QNot Observable ❑Not Applicable 1 High impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/10/18 Data filename: Untitled.rck Page 4 of 9 Section Plans Verified Field Verified Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions &Req.ID 403.6 Automatic or gravity dampers are :QComplies [FR19]2 'installed on all outdoor air QDoes Not intakes and exhausts. QNot Observable QNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title :__ cat _. xrrrsaar � 3 Riznfark AlAh; r3EI1 ffi S Section Plans Verified Field Verified Insulation Inspection Value Value Complies? Comments/Assumptions 6c Req.ID 303.1 All installed insulation is labeled ; C7Complies [IN13]2 or the installed R-values C1Does Not provided. tap 'QNot Observable QNot Applicable 402.1.1, Wail insulation R-value.If this is a R- R- 'DComplies See the Envelope Assemblies 402.2.5, mass wall with at least1z of the 'Q Wood Q Wood QDoes Not table for values. 402.2.6 ;wall insulation on the wall [IN3]2 ;exterior,the exterior insulation Mass ❑ Mass QNot Observable requirement applies(FR10). ❑ Steel 0 Steel eONot Applicable 9 6 303.2 Wall insulation is installed per i jDComplies [IN4]1 manufacturer's instructions. DDoes Not 'ONot Observable , QNot Applicable Additional Comments/Assumptions: diF 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/10/18 Data filename: Untitled.rck Page 6 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID • 402.1.1, ,Ceiling insulation R-value. ' R-l01, R- ❑Complies See the Envelope Assemblies 402.2.1, 0 Wood ;0 Wood ❑Does Not ;table for values. 402.2.2, 402.2.6 0 Steel „❑ Steel [7Not Observable [FUR I„ Applicable 303.1.1.1,;Ceiling insulation installed per ❑Complies 303.2 :manufacturer's instructions. j❑Does Not [F12]1 ;Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable 402.2.3 'Vented attics with air permeable j❑Complies [F122)2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that ;❑Nofi Observable extends over insulation. ❑Not Applicable 402.2.4 ;Attic access hatch and door R- R- ;❑Complies [FI3]1 insulation?R-value of the ❑Does Not adjacent assembly. l ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50= ❑Complies [FI17]1 ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ;❑Complies [FI4]1 cfm/100 ft2 across the system or : ft2 ft2 `❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa.For rough-in ['Not Observable tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 determine air leakage with ' ft2 ft2 ❑Does Not either: Rough-in test:Total k leakage measured with a ❑Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test.Postconstruction test:Total leakage measured with a , pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 .,Air handler leakage designated ;❑Complies (F124]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable DNot Applicable 403,1.1 Programmable thermostats % ;❑Complies [Fl9]2 installed for control of primary :❑Does Not 'heating and cooling systems and initially set by manufacturer to ; ❑Not Observable code specifications. ;❑Not Applicable 403.1.2 :Heat pump thermostat installed '❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Nat Observable [-_:Not., Not Applicable 403.5.1 ;Circulating service hot water j❑Complies [F311]2 systems have automatic or ;❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium impact(Tier 2) 3 Law Impact(Tier 3) Project Title: Report date: 06/10/18 Data filename: Untitled.rck Page 7 of 9 Section # Final Inspection Provisions Plans Verified Field VerifiedValue Value Complies? Comments/Assumptions &Req.ID 403.6.1 'All mechanical ventilation system! ; Complies [F125]2 fans not part of tested and listed iDDoes Not HVAC equipment meet efficacy and air flow limits. ! 0 !DNot Observable DNot Applicable 403.2 Hot water boilers supplying heat OComplies (F126)2 through one-or two-pipe heating DDoes Not systems have outdoor setback control to lower boiler water (]Not Observable temperature based on outdoor !I: Not Applicable temperature. 403.5.1.1 ;Heated water circulation systems; OComplies [F128]2 have a circulation pump.The CDDaes Not system return pipe is a dedicated; ' return pipe or a cold water supply; [JNot Observable ,pipe.Gravity and thermos- DNot Applicable syphon circulation systems are not present.Controls for 'circulating hot water system pumps start the pump with signal ; ;for hot water demand within the occupancy.Controls - automatically turn off the pump :when water is in circulation loop is at set-point temperature and no demand for hot water exists. i 403.5.1.2 ,Electric heat trace systems ;DComplies [F129]2 comply with IEEE 515.1 or UL DDoes Not 515.Controls automatically adjust the energy input to the DNot Observable heat tracing to maintain the DNot Applicable desired water temperature in the piping, 403.5.2 Water distribution systems that Ocomplies [F13012 have recirculation pumps that ,DDoes Not ;pump water from a heated water supply pipe back to the heated ONot Observable water source through a cold ZINot Applicable water supply pipe have a demand recirculation water system.Pumps have controls ;that manage operation of the pump and limit the temperature j of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ' !]Complies [F131]2 tested in accordance with CSA DDoes Not B55.1.Potable water-side pressure loss of drain water heat ! ;C]Not Observable recovery units<3 psi for DNot Applicable individual units connected to one or two showers. Potable water- j ;side pressure loss of drain water heat recovery units<2 psi for individual units connected to 'three or more showers. 404.1 75%of lamps in permanent (]Complies [FI6]1 -fixtures or 75%of permanent '. rDDoes Not fixtures have high efficacy lamps. (]Not Observable Does not apply to low-voltage ` lighting. ;ONot Applicable 404.1.1 ;Fuel gas lighting systems have Complies [FI23]3 no continuous pilot light. Does Not ;INot Observable ' i DNot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/10/18 Data filename: Untitled.rck Page 8 of 9 q � i Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req,ID 401.3 Compliance certificate posted. • ;DComplies [F17]2 '0Does Not ;©Not Observable ;(Dot Applicable 303.3 :Manufacturer manuals for DComplies [F118]3 mechanical and water heating DDoes Not systems have been provided. [JNot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 06/10/18 Data filename: Untitled,rck Page 9 of 9 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 0.00 Ceiling/Roof 49.00 Ductwork(unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door Skylight 0.42 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments