Loading...
2009-055 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20090055 Date Issued: Tuesday, January 15, 2013 This is to certify that work requested to be done as shown by Permit Number P20090055 has been completed. Location: 456 BAY Rd Tax Map Number: 523400-296-016-0001-011-000-0000 Owner: GREGORY V CANALE Applicant: GREG CANALE This structure may be occupied as a: Commercial Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan,Variance, or VVV other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 BayRoad,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090055 Application Number. A20090055 Tax Map No: 523400-296-016-0001-011-000-0000 Permission is hereby granted to: HARRY RUECKER For property located at: 456 BAY Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: GREGORY V CANALE 456 BAY Rd Commercial Addition $20,000.00 QUEENSBURY,NY 12804-0000 Total value $20,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2009-055 534 sq ft commercial addition $100.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,August 24,2011 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) 1 Dated at the To of Que bu �� Tie gust 24,2010 %r /V e�. SIGNED BY � for the Town of Queensbury. Director of Building&Code Enforcement OFFICE USE ONLY /�� / , TAX MAP NO. ` _____( PERMIT NO. ' �•i ` v4�.7 FEES: PERMIT/ RECREATION ENGINEERING ; 01 (If app licable) ; ' PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: _(-,(ea OWNER: A4ir( tZvec k e a ADDRESS: - ��t( 3 r, �aleVS' �llS, A,, �Y ADDRESS: PHONE NOS. -7('/T- J ) v PHONE NOS. N 1 e' CONTACT PERSON FOR BUILDING & 1_�", l i hey.CODES COMPLIANCE: Co,'G�t �Ci�AlP PHONE: LOCATION OF PROPERTY: ,y (' , r HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? ❑ YES fl NO IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z APPLY TO YOUR z 0 cj PROJECT 0 00 (0o u- w 0 F- 0 F- LU p J L � o u- = H a0U z z OL~i. OF- � Wz F- U- n. 2 05 SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO. of UNITS ) TOWNHOUSE BUSINESS OFFICE SM RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST FUEL TYPE: O a l HEAT TYPE: 61s t *HOW MANY FIREPLACE(S): O AND/OR WOODSTOVES(S): d ZONING CATEGORY: P O ARE THERE WETLANDS ON THIS SITE? ('V'17- IS THIS A HISTORIC SITE? kr(1- PROPOSED USE OF BUILDING OR ADDITION: L rA.w 4 �� *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office Town of Queensbury - Community Development Office - 742 Bay Road, Queencoburt/, NY 12804 B 3-LGL 11-05 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ! ARE THERE EASEMENTS ON PROPERTY?_, ►�145 I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete state me nt/descri ptio n of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have rea and agree to the above Signed lit Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is herebyranted to the above g ; This application / proposed action described ; Applicant to erect or alter the building ; ; herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: ; 10 11 11 1 / 1 , 0 , , 0 0 0 , , BUILDING & CODES APPROVAL ' ZONING APPROVAL DATE ' DATE ..................... QUESTIONS? CALL 761-8256 OR EMAIL Office Use Only codes CciagueensburV net VISIT OUR WEBSITE FOR MORE INFORMATION Operating Permit Issued: Yes No www.aueensbury net Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury - Communihj Development Office - 742 Bay Road, Queensbury, NY 12804 Ell, Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: tLIP am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Ins s Initials: . NAME: PERMIT* 657 LOCATION: DATE: — COMMENTS: Y KNA Chimney/'B'Vent/Direct Vent Location Plumbing Vent Through Roof 6'/Roof ConWeft Exterior Finish/Grade Complete 6"in I or Equivalent Interior I Exterior Guardrails 42 in. Platform/Decks Interior I Exterior Ballisters 4 in. Spacing Platform I Decks Stair Handrail 34 in.—38 in./Stop Risers 7"/Treadle 11" Vestibules For Exit doors>3000 sq.It All Doors 36 in.wA over Handle/Panic Hardware if required Exits At Grade Or Platform 36 w x 44' 1 or Equiv. Gas Valve Shut-off &Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Okey Relief Valve Heat Trap/Water Temp.110 Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Sue&for Occupan/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft or VO Mt Line Of Site Od Furnace Shut Off at Enhance to Furnace Area eceiving/Shipping Room(2 hr.), 1 %doors > 10%> 1000 sq.ft %Hour Corridor Doors&Closers FirewaNs/Fire Separation,2 Hour, 3 Hour Complete/Fire Dam /Fire Doors Ceiling Fine Skipphy,3,000 sq.ft Wood Frame Attic Access 30"x 20"x 30' h Crawl Space Access 18'x 24" Smoke Vents Or Fan if required Elevator operation and Signage/Shaft Sealed HandtjNgg Bo mom Grab Bars/Sinks/Toilets Handicapped Bath/Parldng Lot S Public Toilet Room Handicapped Accessible Hand' Servioe Counters 34 in. Checkout 36- Handicapped Ramp/Handrails Continuousl12 In.Beyond(Both CV side Acute Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plait cep If As-built Septic System La out RequW or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler BuildingAccess AN Sides by2 Surface 2W wills May To Issue Temp.or Pofmanent CIO Okay To Issue C/C L:IBuilding&Codes Form UkAding&Code$Vnspecbon FwnsWAffw Taal Final Inspection Reportdoc Revised Jwwety 7,2008 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No...0.9z....Cert. Na 29016 Cut-in Card No..................................... Owner..........C .12.F6........... L. ............................................................................................... /„ Location.... ........ ..x6l ..... �....................................................... f:.4. ..... .... Installation Consisting of.... ............................. ......... .................... _ 12671(� .... ........... .......... ................ .......................... .................................................................................................................................................................................... Installed B .�.:.......y..... C� /✓..'.......................................Lic.No................................................... .....'....:.�,.....1....... . The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making i ions at any time, and if its rules are violated,the Company shall have the right�torepvothis c ific . Date..../... ........�. ............... INSPECTOR..... .. ...... .................................................. Member N.F.P.A.,I.A.E.I. Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: tW am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: _ r ��+'� -Q PERMIT* —b LOCATION:-) y t5( DATE: -- COMMENTS: Y N NA Chim /"B'Vent/Direct Vent Location Plumbing Vent Through Roof 8'/Roof Complete Exterior Finish/Grade Complete 8"in I or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior/Exterior Be inters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in.I Stop Risers T"1 Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 38 in.wlLever Handles/Panic Hardware V required Exits At Grade Or Platform 36 W x 44' or Equiv. Gas Valve Shut-off Exposed S Regukdor 18" Above Grade Floor Bathroom Watertight/Other Fbors Okay Relief Valve Heat Trap/Water Temp.110 revs Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Sup&for Occupapff/Ventlation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Vlfrthin tine Of Site Oil Furnace Shut Off at Entrance to Furnace Area SbckroomtStorage/ReceMng/Shipping Room(2 hr.), 1 %doors > 10%> 1000 sq.fL %Hour Corridor Doors&Closers Firewatls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dam /Fire Doors Calling Fire Stopping, 3,000 sq.It.Wood Frame Attic Access 30"x 20"x 30" h Crawl Spew Access 18"x ZC Smoke Vents Or Fan, if required Elevator Operadon and Signage/Shaft Sealed HandtWeld Bathroom Crab Bars I Sinks/Toilets Handica Bath/Parking tot SigrifteR //, f Public Toilet Room Hand Accessible " ,- 1�� /� 41- Hand' Service Counters 34 in. Checkout 36 Handicapped Ramp/Handrails Continuous/12 In.Beyond(Both sides Active Listening System and Signage Assembly Spam Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required �Final Survey, New Structure/Flood Plater cerfflocadon,if As-buik Septic System La art Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Build' Arxe=AN Sides by 20'1 Driveable Surface 2W wide Okay To Issue Temp. or Permanent CIO Okay To issue C/C L:1Budding&Codes Fom %BWdmg S CodesNnspection Form r4mmerchd Final Inspection ReporLdoc Revised January 7,2008 k_ Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: T PERMIT#: O —D J� LOCATION: DATE: "-it COMMENTS: Chan /"B'Vent/Direct Vent Location C-7�, Plumbing Vent Through Roof 6'/Roof Exterior Finish/Grade Complete 6'in I or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks Interior l Exterior Ballsters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Stop Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft All Doors 36 in.wfiAw Handier/Panic Hardware if required Exits At Grade Or Platform 36 w x 4,V or Eguly. Gas Valve Shut-off &RegulaW IS" Above Grade Floor Batt wn Watertight I Odw Floors Okay Relief Valve Heat Trap/Water Temp.110 Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Supply for Occupa2g/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off within 30 ft.or VM*jn tine Of Site Od Furnace Shut Off at Entrance to Fumaoe Area Stockroom/Storage/ReceMng/Shipping Room(2 hr.), 1 fill doors > 10%> 1000 sq.ft. Hour Corridor Doors&Closers FrewaNs/Fire Separation,2 Hour, 3 Hour Complete/Fire Damee/Fire Doors calling Fire Stopping, 3,000 sq.ft.Wood Frame Attic Access 30'x 20"x 30' h ,Crawl Space Access 18'x ZC Smoke Vents Or Fan if required Elevator operation and S /Shalt Sealed Hand Bathroom Grab Baas/Sinks I Tobb r k�i yJ(� r Handica Bath/Parkin Lot 3 s �` Public Toilet Room Handicapped Agile Handicapped Service Counters 34 in. Checkout 86" Handicapped Ramp/Handrails Continuousl12 in.Beyond sides Active Ustening System and Signage Assembly Spam / ��+►''r'i� Final Electrical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain cerdroadon ff x�✓� , �h S�114 . As built Septic System Layout Required or On File Buildim Number or Tenant Address on Build' or Drivewa C G AP Ce,, )t /"po Water Fountain or Cooler Building Access AS Sides by 2W/Definable Surface 20'wkle Okay To Issue Temp.or Permanent CIO Okay To issue C/C L:\Bulding&Codes Formftild"$Codesunsp x*on FomnsT"nmwcwA Final inspection Report doc Revised January 7,2006 Commercial Final Inspection Report Office No.: (518) 761-8258 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 inspector's Initials: ,VA NAME: & e e- ' lQ3,1� _ PERMIT t. LOCATION: LI DATE: . - ff COMMENTS: Y N NA Chun /"B'Vent/Direct Vent Location Plumbing Vent Th h Roof 6'/Roof Exterior Finish/Grade Complete 6"in I W or Equivalent Interior/Exterior Guardrails 42 in. Platform/Dedcs Interior/Exterior Banisters 4 in. Spacing PWonrr I Dedcs Stair Handrail 34 in.-38 in./Stop RMers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 in.wA ever Handles/Panic Hardware if required Exits At Grade Or Platform 36 W x 44' or Equiv. Gas Valve Shut-off Exposed S Regulator(ID Above Grade Floor 80mxxn Watertight/Ottrer Floors Okay Relief Valve Heat Trap/Water Ter .110 Degraw Maximum Baler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fret Air Sup&for /Ventilation Combustion Low Water Shut Off For Boilers Gas Fumaoe Shut Off Within 30 ft.or VYrthin Line Of Site Oil Fumace Shut Off at Enhance to Fumace Area Stockroom/StoragetReceiving/Shlpping Room(2 hr.), 1 %doom > 10%> 1000 sq.ft. %Hour Corridor Doors&Closers Fr swans i Fire Separation,2 Hour,3 Hour Complete/Fire Dam rs/Fire Doors ceiling Foe Stopping,3,000 sq.ft.Wood Frame Attic Access 30"x 20'x 3(r h Crawl Space Access 16'x 24" / Smoke Vents Or Fan if required /' Elevator Operation and S /Shaft SealedHand' Bathroom Grab Bars/Sinks/Toilets z Handicapped Bath/Parking Lot S / /� N SC,� Public Toilet Room Handica A�sible -�.Hs/�•f cJ Handicapped Service Counters 34 in. Checkout 36" /A7 Handicapped Ramp/Handrails Continuous/12 in.Beyond(Botlr sides Active Listening System and SigMe Assembly Final Electrical/Flex Gas Piping Bonded - Fns Site Plan/Variance required Final Survey, New Structure/Flood Plain corWication K recL. As-built Septic System La out Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access AN Sides by 20`/Driveable Sud we 2W wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C LABudding 8 Codes Forrm%BuildkV&CodesUnspedion FamslCommercial Final Inspecdon ReporLdoc Revised January 7,2008 Commercial Final Inspection Report Office No.: (518)761-8258 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT#. LOCATION: DATE: 2 COMMENTS: Y NA Chimney/'B"Vent/Direct Vent Location / /r1 PlumbingVent Through Roof 6 /Roof' Exterior Finish/Grade Complete 6"in I or Eguhmient Interior I Exterior Guardrails 42 in. Platform/Decks Interior l Exterior Ballisters 4 in.Spacing Platform/Decks Stair Handrail 34 in.—38 in./Stop Risers T"1 Tr++eads 11" Vestibules For Exit doors>3000 sq. ft All Doors 36 in.wA wer Handles/Panic Hardware if required Exits At Grade Or Platform 36 w x 44'QyCwwff or Equiv. Gas Valve Shut-off &Regulator 18" Above Grade Floor Sadhroom Wateftht/Other Floats Okay Relief Valve Heat Trap I Water Temp.110 Degraw Maximum Boiler/Furnace Enclosure 1 hr.or Fire Extinguishing System Fresh Air Supply for Occupa2ff/Vendation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft or Vftin Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/StonageiReceiving/Shipping Room(2 hr.), 1 %doors > 10%> 1000 sq.ft. %Hour Corridor Doors&Closers Firewafis I Fire Separation,2 Hour,3 Hour Complete/Fire Dam rs/Fire Doors Ceiling Fine Stoppiry, 3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 3(r h ,CrawlSpace Access 18"x 24' Smoke Vents Or Fan, if required Elevator operation and Siggao/Shaft Sealed Hand" Ba fwn Crab Bars/Sinks/Toilets Handicapped Bath/Parldng Lot SlgngP Public Toilet Room Handicapped Accessible Handicapped Service a Counters 34 in. Checkout w Handicapped Ramp/Handralls Continuous/12 in.Beyond(Both � / sides]G'�- f GUt'f` !Y• C Active Lidening System and Signage AwernWy Spam Final Electrical i Flex Gas Piping Bonded 9 Site Plan/Variance required Final Survey, New Shucture/Flood Plait cefflicadon,N As-built Septic SyMem La out Regaired or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access AN Sides by 20'/D&WINWOR Surface 2W wide Okay To Issue Temp. or Penman C/ Okay To Issue C/C LABuilding&Codes Fonns%Builyding&CodesUnspection Fo mW4mnwcial Final Inspection Report.doe Revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 pate Insp6ction request received: Qcteer�#~ Building&Code Enforcement Arrive:-am/pm Depart: s am/pm 742 Bay Road, Queensbury, NY 12804 tropectoes Initials: NAME: PERMIT* LOCATION: INSPECT ON: - TYPE OF STRUCTURE: Y COMETS-Framing -- _--�- Attic Access 7Z 30' minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sung nailed properly 1Y O.C. . Headroom 6 ft. 8 in. Stairwtags 36 in. or more Exterior Dedc Bracing Headroom 6 fL 8 in. Notch/Holes/Bearing Walls MOW Strapping for Noshes Top Plate 1 % w 16 gauge 8 16D nde each we Draft stopping 1,000 sq. ft floor trusses Anchor Bold 6 ft. or less on center Ice and waiter shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wail 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation Home side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ce!qn2LAtall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. CM 5.7 sf above/below grade 5.0 sf grade L adld ft&Codas Forms-OLDSuftV&Codoftpectbn FomWW=ft FWuk*ft hapedw ReporLdoc RWbed Jwmm"7,2000 ), �)a w. Foundation Inspection Report Office No.(518)761-8256 Date Inspection request received: 2 —7 / Queensbury Building&Code Enforcement Arrive: am/pm Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: NAME. �t)� �`— PERMIT#: LOCATION: .4 INSPECT ON: TYPE OF STRUCTURE: Y Footings 9 WA iers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this pur pose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproof ng Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\BuUding&Codes Fomis\Building&Codes\lrgxxtion Forn sWoundatlon Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Framing / Flrestopping Inspe �on Report �T Olfbe No. (518)761-8256 Dale I pection Queensbury 6uikiing&Code Enforcement Arrive:: a 742 Bay Road, Queerwbkuy, NY 12804 Inspector's In' NAME: RMIT#: 00 LOCATION: I SPECT ON: �// TYPE OF STRUCTURE: Framing C�tiAtiAE Attic Access 22" x 30*minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posh/Main Beams Exbertor sheeting naffed property 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Hobs/Bearing Wells Metal Strapping for Notches Top Plate 1 %M 16 8 16D naps each side Draft shopping 1,000 sq.ft floor trusses Anctor Bolts 6 ft or less on center ice and water shield 24 inches from wail Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in caft min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingtwall Windows Habitable Space/Bedrooms 24 in. (H) 20 In. OM 5.7 sf above/below grade 5.0 sf grade LASU11 drg&Codas Foens4M)S ildi v&CodesYrapsaion FomnsY==ft FksdcPPkV k"P*d0n RapofLdoc PAfted Jam"7,2M8 /'�--3 7V-r4T! Foundation Inspection Report Office No.(518)761-8256 Date Inspection req ed Queensbury Building&Code Enforcement Arrive:' 7.1� Depart: 742 Bay Rd.,Queensbury,NY 12904 Inspector's Initials• l NAME: C�n RMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: C r,�CoC re N/A 06 Footinim Piers .� onolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement Of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproof ng Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. U\Building&Codes Forms\Building&Codes\Inspection Fon nsWoundatlon Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Framing / Firestopping Inspection Report Office No. (618)761-8256 Dater I request received: Queensbury Building&Code Enforcement Arrive: 4) am/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: J'L2 NAME: � PERMIT#: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing COMMENTS: 27 x 30" minimum Jedc Studs/Headers �L� ty�� axe _ Bracing/Bridging L�e,�k Joist hangers Jack Posts/Main Beams P Exterior sheeting raged properly 17 O.C. Headroom 6 ft. 8 in. Staines 36 in. or more Exterior Dedc Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Meted Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nds each side Draft stopping 1,000 sq.ft.floor Umm Anchor Bolts 6 fk or less on venter Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 Inch insulation in min. Garage Fire Separation House side's inch or 5/8 inch Type X Garage side 5/8 inch Type X CellIngfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade L,.SdMft&Codes ForM$4 Dftk i V&Cods6VMpseifon FormsWmnft FMwdoppkV kowdon PaporLdoc Rw sed army 7,2= )o— -� Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection r f e iyd: Queensbury Building &Code Enforcement Arrive: " ` ` `art: C> a 742 Bay Road, Queensbury, NY '12804 Inspector's Initials: NAME: PER T #: LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N /A 4Rjjjh Plumbi / ail Plates in Ve ents in Place imum Drain Size ing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent,Attic Vent Door/Window Sealed No Insulation Dud/Hot Water Piping insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing insulation Report.revised Nov 17 2003,revised February 15,2005, revised January 7,2008 DEED REFERENCES tt LAWRENCE LUPO&PAULA LUPO TO _ ` o HARRY RUECKER&KARL A.RUECK DATED:OCTOBER 15, 2008 BOOK.3653 PAGE.30 2 em, a WETLANDS o LAWRENCE LUPO&PAULA LUPO TO COUNTY OF WARREN sm 40 61 SITE w p DATED:DUNE 2, 1975 WETLAND BOOK:589 PAGE:213 rn an G ... r LAWRENCE LUPO&PAULA LUPO s CN TO u, r COUNTY OF WARREN DATED:DUNE 2, 1975 BOOK.•589 PAGE:216 , t r- b MAP REFERENCES LOCATION MAP 1 —800' (D o z MAP OF LANDS OF 0 VICTOR E TURNER r� BY.'LESLIE W. COULTER DATED:JULY 11, 1952 Cd (� PERMANENT EASEMENT � (1 MAP OF SURVEY MADE FOR - 320 AS PER DEED REFERENCE No. 3 U LAURA LUPO ( z r BY VAN DUSEN&STEVES J SjL C) DATED:APRlL 10, 1985 / PROPOSED GRADING a tv EASEMENT04 H ►� ' �!!C� ,(�T I.RFI r2 p, sr H O LANDS N/F OF U '' SHABAT i O 5ED ills 31 77' 1-1 O BENCHMARK RAILROAD t SPIKE IN POLE NM#79 ELEVATION=322-67 J 1 J / f 30-33' 1 AID 1 OR ( t 5 � t ACK J 0 ro Lol FOR PR PO ED / ~— / PROFESSIONAL OFFICE ( � FF-325.73 J f f p \ AREA J I Q 10,056.43t sq. ft. / J 0.231 acresLiGhT / t ' Y t / r f f 1 STORY / ! WOOD FRAMED 0' 12' 24' 36' 48' Q 43 j HOUSE 36' L-6.5T11 1 f IPF 4R-2287 .33 wv ° °--- 3 .4 / /� ' ''�� fry ` APPROXIMATE P SEPTIC ORC s7' S SYSTEM + / oMi IPF °- °` O RIM=320.G4 _.w- �--'_� ° / G2.6& / IPF 320 _ _.. _ ._. __ _._ _ _ �... 1 F^ 315 ...... IPF 1 2 0' f LEGEND SITE DATA LANDS N/F OF LUPO EXISTING CONDITIONS IPFO = IRON PIPE FOUND 12' PARCEL AREA 10,056.43 sq. ft. CIRFO = CAPPED IRON ROD FOUND BUILDING COVERAGE 1,329 sq. ft. a-----°-------a = WOODEN FENCE LINE PORCHES/DECKS 105 sq. ft. 4D= WELL ASPHALT/STONEICONC. 937 sq. ft. TOTAL NON PERMEABLE 2,371 sq. ft. D4= WATER VALVE OR 23.57% NON PERVE48LE 24' p ZONING IMFOAMATIDN: PROPOSED CONDITIONS c(L= uT1uTY POLE GRAPHIC SCALE PARCEL AREA 10,056.43 sq. ft. ECE D ZONED PROFESSIONAL OFFICE BUILDING (AVERAGE 1,329 sq. ft. �o u s �I I MIN. LOT SIZE 20,000 sq. ft. PORCHES/DECKS 502 sq. ft. AUG 01� 36' ASP MIN. LOT IYIDTH 80' HALT/STON ft E/CONC. 1,718 sq. . IN FEET } TOTAL NON PERMEABLE 3,549 sq. ft. OWNER/APPLICANT i inch = 14 ft SET%WKS OR 35.29% NON PERMEABLE GREGORY V. CAIW4LE T PLANNING Ql�NSB RY FRONT 50 � PROPOSED BLDG. MT. LIGHTING 456 BAY ROAD SIDES 20 PARKING REQUIREMENTS TYPICAL PHOTOMETRIC DIAGRAM DATUM=U S.G.S.t REAR 20' 1 PER 300 sq. ft. GROSS LEASABLE SPACE QUEENSBURY NY 12804 150W HPS CUT—OFF WALL PAK CONTOUR INTERVAL= 1 FOOT PERMEf18LE 30% 534 sq. ft. LEASABLE PLUS 2 FOR RESIDENCE PHONE 793-5108 t zvt-: FOR A TOTAL OF 4 REQUIRED SPACES Canole 6 - - DWG. NO. 08163