Loading...
RC-0491-2018 TOWN OF QUEENSBURY ot, I,`' If742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building&Codes (518) 761-8256 y BUILDING PERMIT Permit Number: RC-0491-2018 Tax Map No: 309.17-1-9 • Permission is hereby granted to: Matthew Suders For property located at: 42 EAGAN RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance . Type of Construction Owner Name: Diana Suders • Single Family-Addition $144,000.00 Owner Address: 42 Eagan RD • Total Value $144,000.00 Queensbury,NY 12804 , Contractor or Builder's Name/Address Electrical Inspection Agency . - Record Time Construction Co 78 Maple ST ' Hudson Falls,NY 12839 Plans&Specifications • Residential Addition:Third bay of 352 sq.ft.added onto existing garage Second Story addition of 440 sq.ft.above the existing garage(living space)with 2nd story deck 96 sq.ft. Cross Ref.Area Variance Z-AV-19-2018 approved June 27,2018 . I $ 250.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday,August 21,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town o - "e-._.ury; ues 6,.,, ,,f,I. - 21,2018 4 SIGNED BY: 1 4 for the Town of Queensbury. Director of Building&Code Enforcement • Office Use Only , c - I ADDITION/ALTERATION PERMIT Permit#: 49/ d-o / 81 c• APPLICATION Permit Fee:$C3qp ibwn of 41pe;;A:ury' • 742 Bay Road,Queensbury,NY 12804 Invoice#: 7/g P:518-761-8256 www.queensbury.net /41.LICA:; Project Location: eetaro [1)111ga-6641y AV Tax Map ID #: 309. 17-1-9 Subdivision Name: sw 1E- Fri) CONTACT INFORMATION: 2U j • Applicant: 11 JUL 3 El Name(s): in 04-1-1-1-eto Sut.(4erS TCW or JURY Mailing Address, C/S/Z: il'A QAAPertsinuiry Aiy 1-VO CommuNr DEvELORviENT Cell Phone: ( -51?) ) 1o0A(/) Land Line: ( ) Email: rkudertz;6 roacIrGi nner; roirn • Primary Owner(s): Name(s): rYt Alei,) na (,3grs Mailing Address, C/S/Z: Siot)c. Cell Phone: ( •S Land Line: ( Email: • Contractor(s): n Business Name: ke cOr(21-17 m e 0 inSlilA,C117 br'N Co Contact Name(s): cv-44- ',c-cL Address, C/S/Z: 15 toldSi 14fAcksor, AJ I Cell Phone: ( ) ' O Land Line: ( Email: • Architect(s)/Engineer(s): Business Name: (jecti .e, 'T Jcrcir, rt P-111-ec+ Contact Name(s): C-s)fore: i iTrr)14 rei Mailing Address, C/S/Z: 7?) e.,-+ lit)T;C\ SPA ,A)V ia0 a c-.7 Cell Phone: ( ) C, - 170:6 Land Line: ( Email: Contact Person for Building & Code Compliance: 4ift:c4 Cell Phone: ( 511 g3()-torD-Ce Land Line: ( Email: Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 PROJECT INFORMATION: TYPE: Commercial Residential j95(0 y� • WORK CLASS: 1 Single-Family Two-Family _Multi-Family(#of units ) Townhouse Business Office Retail Industrial/Warehouse _Garage (#of cars ) _Other (describe ) � `1 .ADDITION SQUARE FOOTAGE: � � �s� • Yitilt,ALTERATION SQUARE FOOTAGE: 1st floor: 02 a X ,•{ `� � S 1st floor: 2nd floor:_ _ --p _,>.A- : Nr mover ih-r a 2nd floor: 3rd floor: - :-?"' Art 3rd floor: Basement space): �d�-�, (habitable s ace Total square feet: T ...dr Total square feet: .,1 Q)(4S'-C* F2-40 dick /fir A (ter ADDITIONAL PROJECT INFORMATION: Apt 40,0 r 1. Estimated Cost of Construction: $ I Lig/ WO -Z- 1✓-1401 2. If Commercial project, what is the proposed use: 3. Source of Heat (circle one): Gas Oil Propane Solar Other Fireplaces need a separate Fuel Burning Appliances &Chimney Application 4. Are there any structures not shown on the plot plan? YES NO Explain: 5. Are there any easements on the property? YES NO 6. SITE INFORMATION: a. What is the dimensions or acreage of the parcel? b. Is this a corner lot? YES O c_Nc. Will the grade be changed as a result oft e construction? YES NO I�d. What is the water source? RBt7f` y PRIVATE WELL e. Is the parcel on SEWER or a PR T'E SEPTIC system? 0 ri+,ram sP -ic r Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 L3ECLARATION: 1. I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. • 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: • PRINT NAME: ,Jicyir hi e, Scci& 7 SIGNATURE: ti(lr;mr,, ,,r (' _ DATE: • Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 Your Company Here... Sagan rd Your Address Here... -City Here..., State Here..Zip Here... �} ' Phone Here -Email Here... ; .o e ary, ny 12804 Sales Consultant: Al'� � Job#: TOWN OF OUEENSBURY Date: 08/17/2018 COMMUNITY DEVELOPMENT System I (Average Load Procedure) Design Conditions Location: Glens Falls AP, New York Elevation: 335 ft Daily Range: Medium Input Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 43° N Design Grains: 26 Summer: 92 72 Heated Area 762 Sq.Ft. Winter: -17 70 Cooled Area 762 Sq.Ft. FILE COPY Heat/Loss Summary (July Heat Load Calculations) Gross Sensible Latent Area Loss Gain Gain Walls 920 4389 1128 0 Windows 178 6940 6531 0 Doors 0 0 0 0 Ceilings 762 1922 593 0 Skylights 0 0 0 0 Floors 618 1882 327 0 Room Internal Loads 0 2400 0 Blower Load 1707 0 ,,,Mtn Hot Water Piping Load 0 0 0 % ,. Winter Humidification Load 0 0 0 miiiiikd Infiltration 5931 715 575 —__.__ — —' Approved ACCA Ventilation 5742 1320 1061 MJ8 Calculations Duct Loss/Gain EHLF=0 ESGF=O 0 421 416 AED Excursion n/a 1656 n/a Subtotal 26806 16798 2052 Total Heating 26806 Btuh Total Cooling 18850 Btuh 53 Linear ft. of Hydronic Baseboard *Calculations are based on the ACCA Manual J 8th Edition and are approved by ACCA.All computed calculations are estimates based on building use,weather data, and inputted values such as R-Values,window types, duct loss, etc. Equipment selection should meet both the latent and sensible gain as well as building heat loss. This application has glass areas that produce large cooling loads for part of the day. Variable air volume devices are required to overcome large spikes in solar load for one or more rooms. Install a zoned system or provide zone control(individual, motorized, thermostatically controlled dampers) for problem rooms. Single speed equipment may not be suitable for this application. Adtek AccuLoad Report Version 17.3.5 Page 1 Your Company Here... 42 eagan rd Your Address Here... -City Here..., State Here..Zip Here... Phone Here - Email Here... queensbury, ny 12804 Sales Consultant: Job#: Date: 08/17/2018 System l Load Chart Heat Loss Percentages Walls El Windows & Skylights 21% 16% II Doors Ceilings r Floors Misc System Loss � 26% III Infiltration 22% Al ��" � Ventilation 7% 7% Duct Loss Heat Gain Percentages • Walls 5% 7% �;�°` Skylights ' Windows & Sk li hts 15% -. II Doors Ceilings Floors lk x. 42% . _® Internal Gains Infiltration III 15% Ventilation 2%4% • Duct Loss II Adtek AccuLoad Report Version 17.3.5 Page 2 Your Company Here... 42 eagan rd Your Address Here... -City Here..., State Here..Zip Here... Phone Here - Email Here... queensbury, ny 12804 Sales Consultant: Job#: Date: 08/17/2018 Equipment Selection Design Conditions Design Location: Glens Falls AP, New York Relative Humidity: 50% Elevation: 335 ft Summer Outdoor Design: 92 Latitude: 43° N Winter Outdoor Design: -17 Daily Range: Medium Summer Indoor Design: 72 Design Grains 26 Winter Indoor Design: 70 Heating Equipment Mfg: YORK BY JOHNSON CONTROLS Altitude Correction Factor: 0 Model: TM9E040A10MP11 Heating Input(btuh): 40 AHRI Ref#: 7137317 Heating Output(btuh): 38000 Efficiency (AFUE): 95 Calculated HeatPump 0 Output @ Design (btuh): Cooling Equipment Mfg: CHAMPION BY JOHNSON Altitude Correction Factor: 0 Oudoor Unit Model: TC3B2421 Rated Total Cooling (btuh): 24000 Coil: CF/CM36A Sensible Cooling (btuh): 18000 Furnace: TM9E040A10MP11 Latent Cooling (btuh): 6000 AHRI Ref#: 8535240 SEER - EER@95: Heat Pump HSPF: Summary MJ8 Calculations Status Equipment Capacities Sensible Gain (btuh): 16798 Sufficient Sensible Capacity (btuh): 18000 Latent Gain (btuh): 2052 Sufficient Latent Capacity (btuh): 6000 Total Heat Gain (btuh): 18850 Sufficient Total Capacity (btuh): 24000 Heat Loss (btuh): 26806 Sufficient Heating Capacity (btuh): 38000 Adtek AccuLoad Report Version 17.3.5 Page 3 Your Company Here... 42 eagan rd Your Address Here... -City Here..., State Here..Zip Here... Phone Here - Email Here... queensbury, ny 12804 Sales Consultant: Job#: Date: 08/17/2018 System — AED Curve — DAL 1.3 — 1.5 9000 8000 7000 6000 = 5000 03 4000 3000 2000 1000 0 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour AED Excursion: 1656 btuh AED Status: System does NOT have Adequate Exposure Diversity. AED Flag: This application has glass areas that produce large cooling loads for part of the day. Variable air volume devices are required to overcome large spikes in solar load for one or more rooms. Install a zoned system or provide zone control (individual, motorized, thermostatically controlled dampers) for problem rooms. Single speed equipment may not be suitable for this application. Hours are listed in 24-hour format: 8 is 8am, 20 is 8pm. Adtek AccuLoad Report Version 17.3.5 Page 4 - Your Company Here... 42 eagan rd Your Address Here... -City Here..., State Here..Zip Here... Phone Here - Email Here... queensbury, ny 12804 Sales Consultant: Job#: Date: 08/17/2018 System I Breakdown Item Name U-Value /SHGC Net Area Htg. HTM. Clg. HTM Sens. Htg. Sens. Clg. Lat. Clg. Total Clg. Construction Type System I .. . 0..........._. 1707 0 1707 bathroom 0 0 0 0 Ceiling 0.029 90 2.523 0.78 227 70 0 70 Ceiling Below Roof JoistsIDark or Bold Color Asphalt ShinglesINAIR-38 blanket or loose fill Floor 0.035 90 3.045 274 48 0 48 Floor Over Open Crawl Space or GarageINAIPassiveINAjR-30 boardlAny Floor CoveringINAINA . . ..................................................................................................................................................................................................................................................................................................................... East Wall 0.068 66 5.916 1.52 390 100 0 100 Frame Wall/PartitionINAINA!WoodIR-191NoneINAjSiding or StuccoINA Window-2x3 .0.42/0 6 36.54 34.17 219 205 0 205 French DooriFrench DoorIClearl2 PanelWood, Wood with Metal Clad, or Vinyl bedroom 1 0 0 0 0 Ceiling 0.029 180 2.523 0.78 454 140 0 140 Ceiling Below Roof JoistsIDark or Bold Color Asphalt ShinglesINAIR-38 blanket or loose fill Floor 0.035 180 3.045 548 95 0 95 Floor Over Open Crawl Space or GarageINAIPassiveINAIR-30 boardlAny Floor CoveringINAINA South Wall 0.068 88 5.916 1.52 521 134 0 134 Frame Wall/PartitionINAINA!WoodIR-19!NoneINAlSiding or StuccoINA . . ......................................................................................................................................................................................................................................................................................................... West Wall 0.068 94 5.916 1.52 556 143 0 143 Frame Wall/PartitionINA!NAIWood!R-19!NoneINAISiding or StuccolNA Window-4x5 0.47/0 20 40.89 38.65 818 773 0 773 OperablelNormal WindowILow-e (0.20)12 Pane (0.05) Surface 2IWood, Wood with Metal Clad, or Vinyl Window-6x5 0.47/0 30 40.89 38.67 1227..............................1160_.........................................0 ...........................................116 ................. 0 Adtek AccuLoad Report Version 17.3.5 Page 5 - Your Company Here... 42 eagan rd Your Address Here... -City Here..., State Here..Zip Here... Phone Here - Email Here... queensbury, ny 12804 Sales Consultant: Job#: Date: 08/17/2018 OperablelNormal WindowjLow-e (0.20)12 Pane (0.05) Surface 2IWood, Wood with Metal Clad, or Vinyl . . . . . ......................................................................................................................................................................................................................................................................................................................................... bedroom 2 0 0 0 0 Ceiling 0.029 132 2.523 0.78 333 103 0 103 Ceiling Below Roof Joists!Dark or Bold Color Asphalt Shingles!NA!R-38 blanket or loose fill Floor 0.035 132 3.045 402 70 0 70 Floor Over Open Crawl Space or Garage!NAiPassiveINAIR-30 boardjAny Floor Covering!NAINA East Wall 0.068 66 5.916 1.52 390 100 0 100 Frame Wall/PartitionINA!NA!Wood!R-19!None!NAjSiding or StuccolNA ......................................................... .... Window-6x5 0.42/0 30 36.54 34.17 1096 1025 0 1025 French DooriFrench Door!Clear!2 PanelWood, Wood with Metal Clad, or Vinyl South Wall 0.068 88 5.916 1.52 521 134 0 134 Frame Wall/Partition!NA!NA!Wood!R-19!None!NAISiding or Stucco!NA Kitchen 0 2400 0 2400 Ceiling 0.029 144 2.523 0.78 363 112 0 112 Ceiling Below Roof Joists!Dark or Bold Color Asphalt ShinglesINA!R-38 blanket or loose fill West Wall 0.068 54 5.916 1.52 319 82 0 82 Frame Wall/Partition!NA!NA!Wood!R-19!None!NA1Siding or Stucco!NA Window-6x7 0.42/0 42 36.54 34.17 1535 1435 0 1435 French DoorlFrench Door!Clear!2 PanelWood, Wood with Metal Clad, or Vinyl North Wall 0.068 96 5.916 1.52 568 146 0 146 Frame Wall/Partition!NA!NAIWood!R-19!None!NAlSiding or Stucco!NA Living Room 0 0 0 0 .. .. ....... . . . .................................................................................................................................................... ... . .. Ceiling 0.029 216 2.523 0.78 545 168 0 168 Ceiling Below Roof JoistslDark or Bold Color Asphalt ShinglesINA1R-38 blanket or loose fill Floor 0.035 216 3.045 658 114 0 114 Adtek AccuLoad Report Version 17.3.5 Page 6 Your Company Here... 42 eagan rd Your Address Here... -City Here..., State Here..Zip Here... Phone Here - Email Here... queensbury, ny 12804 Sales Consultant: Job#: Date: 08/17/2018 Floor Over Open Crawl Space or GaragejNAIPassivejNAlR-30 boardlAny Floor CoveringINAlNA North Wall 0.068 96 5.916 1.52 568 146 0 146 Frame Wall/PartitionINAINAIWoodjR-191NonejNAlSiding or StuccoINA West Wall 0.068 94 5.916 1.52 556 143 0 143 Frame Wall/PartitionINAINAIWood1R-191NoneINAISiding or StuccolNA Window-4x5 0.47/0 20 40.89 38.65 818 773 0 773 OperablelNormal WindowlLow-e (0.20)12 Pane(0.05) Surface 2jWood, Wood with Metal Clad, or Vinyl Window-6x5 0.47/0 30 40.89 38.67 1227 1160 0 1160 OperablelNormal WindowlLow-e (0.20)12 Pane(0.05) Surface 2IWood, Wood with Metal Clad, or Vinyl Adtek AccuLoad Report Version 17.3.5 Page 7 Your Company Here... 42 eagan rd Your Address Here... -City Here..., State Here..Zip Here... Phone Here -Email Here... queensbury, ny 12804 Sales Consultant: Job#: Date: 08/17/2018 System I Design Conditions Location: Elevation: 0 Daily Range: 0 Design Data: Outdoor Dry Bulb Indoor Dry Bulb Latitude: 0 Design Grains: 0 Summer: 92 72 Summer Design RH% 0 Winter: -17 70 Heating Equipment Mfg: YORK BY JOHNSON CONTROLS Heating Input(btuh): N/A Model: TM9E040A10MP11 Heating Output(btuh): 38000 AHRI Ref#: 7137317 Calculated HeatPump 0 Output @ Design (btuh): Efficiency (AFUE): N/A Outdoor Equipment Mfg: CHAMPION BY JOHNSON Rated Total Cooling (btuh): 24000 Oudoor Unit Model: TC3B2421 Sensible Cooling (btuh): 18000 Coil: CF/CM36A Latent Cooling (btuh): 6000 Indoor Unit: TM9E040A10MP11 AHRI Ref#: 8535240 Adtek AccuLoad Report Version 17.3.5 Page 9 Your Company Here... 42 eagan rd Your Address Here... -City Here..., State Here..Zip Here... Phone Here - Email Here... queensbury, ny 12804 Sales Consultant: Job#: Date: 08/17/2018 Expanded Manual S (ACCA Guidelines) MJ8 Design Calculations Sensible Gain (btuh): 16798 Design TD for Airflow: 17 Latent Gain (btuh): 2052 Design CFM: 898 Total Heat Gain (btuh): 18850 SHR: 0.89 Heat Loss (btuh): 26806 Manufacturers Performance Data(A) Entering Coil Temperature = 75 (F db) Lower Return Air Total Sensible Latent CFM (F wb) BTUH BTUH BTUH SHR Rated CFN @ Rated RA Temperature: 0 0 0 0 Rated CFN @ Design RA Temperature: 0 63 0 0 0 Rated CFN @ Rated RA Temperature: 0 0 0 0 Manufacturers Performance Data(B) Entering Coil Temperature = 75 (F db) Higher Return Air Total Sensible Latent CFM (F wb) BTUH BTUH BTUH SHR Rated CFN @ Rated RA Temperature: 0 0 0 0 Rated CFN @ Design RA Temperature: 0 63 0 0 0 Rated CFN @ Rated RA Temperature: 0 0 0 0 Equipment Performance Data Entering Coil Temperature= 75 (F db) Design Return Air Total Sensible Latent CFM (F wb) BTUH BTUH BTUH SHR Intopolated Equipment Capacity 0 0 0 Excess Latent Capacity Calculation 0 0 0 0 0 Capacity @ Design CFM/RA (F wb) 0 0 0 Equipment Capacity as a % of Design Equipment Performance Data Capacity Capacity Thermal Supplemental Entering Coil Temperature= 75 (F db) 47 17 F db Balance Heat Required @F db @ Point Heat Pump Data N/A N/A 0 0 Desired Calculated Input Output AFUE Temperature Airflow Capacity Capacity Rise Furnace Data N/A N/A N/A N/A 0 Adtek AccuLoad Report Version 17.3.5 Page 10 • fantech® a systemair company FLEX 100H ES FR. AIR APPLIANCE Documenttype: Product card Document date: 2018.08.17 Item no. 44001 Generated by: Systemair Online Catalogue 6 2100111`, 111V1 "" DERTlFIED C us ENERGYSTAR Description • Airflow up to 104 cfm @ 0.4"PS serves 1 to 7 bedroom homes • Top-mounted ports for easier duct connectivity • Unobstructed front access • The TurboTouch feature delivers up to 50%more exhaust capacity • Aluminum core provides superior heat transfer capability • Integrated airflow measurement system allows for rapid and accurate reading of _ airflow during installation ;l[ Application ;'i `-- As Fantech's masterpiece of versatility,features and efficiency,the Flex 100H ES is ideal for high-rise apartment applications,condominiums,single and multi family homes.With its compact top port design featuring 5 inch oval collars and the it included EZ-MountTM wall bracket,the Flex 100H ES can be installed in spaces as small as 24 inches,such as a closet or maintenance room. i� How it works -- Unlike traditional HRVs that require excessive power to meet supplemental ventilation needs,the compact,yet powerful Flex 100H ES allows for sizing based -` entirely on principal ventilation requirements.With its exclusive TurboTouchTM feature,the Flex 100H ES can deliver up to 50%more exhaust capacity to easily meet supplemental ventilation needs whenever additional airflow is required. Technical parameters • Nominal data Voltage 120 V Frequency 60 Hz Phase 1 Rated power 168 W Current 14 A Airflow high 104 cfm Static pressure 0,4 in.wg Certificate CSA,HVI,ENERGY STAR Weight 39,2 lbs. Name:FLEX 100H ES FR.AIR APPLIANCE I Item no.:44001 1/5 Document type:Product card j Document date:2018-08-17 I Generated by:Online catalogue Energy performance . Heating Supply temperature Net airflow Consumed power Sensible recovery efficiency Apparent sensible effectiveness Latent recovery/moisture transfer °F(°C) cfm(Us) W % % - - 32(0) 64(30) 50 65 69 0.02 32(0) 81 (38) 65 63 68 -0.01 32(0) 102(48) 100 60 66 0.00 -13(-25) 66(31) 65 62 65 0.04 Dimensions _ • -.l. E . E • A B C D E F Duct size 21 1/2(546) 14 1/2(368) 15 5/8(397) 17 8/9(454) 22 1/2(572) 15(381) 5(125)Oval Dimensional information is in inches(mm) Name:FLEX 100H ES FR.AIR APPLIANCE I Item no.:44001 2/5 Document type:Product card I Document date:2018-08-17 I Generated by:Online catalogue ' ,.:,. fantech® a systemair company FLEX 100H ES FR. AIR APPLIANCE Documenttype: Product card Document date: 201841 8.17 Item no.44001 Generated by: Systemair Online Catalogue 2100 NV. CERTIFIED C US ENERGY STAR Description • Airflow up to 104 cfm @ 0.4"PS serves 1 to 7 bedroom homes • Top-mounted ports for easier duct connectivity • Unobstructed front access • The TurboTouch feature delivers up to 50%more exhaust capacity • Aluminum core provides superior heat transfer capability • Integrated airflow measurement system allows for rapid and accurate reading of airflow during installation I It Application As Fantech's masterpiece of versatility,features and efficiency,the Flex 100H ES is ideal for high-rise apartment applications,condominiums,single and multi family homes.With its compact top port design featuring 5 inch oval collars and the included EZ-Mounter wall bracket,the Flex 100H ES can be installed in spaces as small as 24 inches,such as a closet or maintenance room. How it works Unlike traditional HRVs that require excessive power to meet supplemental \!I OP_ - - ventilation needs,the compact,yet powerful Flex 100H ES allows for sizing based \_ -- entirely on principal ventilation requirements.With its exclusive TurboTouchTM feature,the Flex 100H ES can deliver up to 50%more exhaust capacity to easily meet supplemental ventilation needs whenever additional airflow is required. Technical parameters Nominal data Voltage 120 V Frequency 60 Hz Phase 1 -- Rated power 168 W Current 1,4 A Airflow high 104 cfm Static pressure 0,4 in.wg Certificate CSA,HVI,ENERGY STAR Weight 39,2 lbs. • Name:FLEX 100H ES FR.AIR APPLIANCE I Item no.:44001 1/5 Document type:Product card I Document date:2018-08-17 I Generated by:Online catalogue Y Y • Wiring SPEEDS n4V 'y ti BFEED n• Z°- t,JUMPER Him y�n�1�ftllfA 1 SEnit6S N SIAM By �- - U___��6 �,� JP3 1Psd! 51rg ph} Pur Elk- TOR ' 8m GLarK iia MITEN• �CQA ISZ fit ^ Iin IA I - Qiie GFa0 it Ocso; ,off o:a Lsj 0 0151.111 rARR01AN IIA ObLrk P • f rrVVtt;; 11111 1tHITEEll.tt r OtLLY l3'i +o©C ,—.1 II 0 AUTO XI MN II i 0aP1 R 44?t 4 L �_a0R015r --y�r_���a y am�m�:_ }ET/REO aa.•..,®.6lTfl4ttJ--_ mm-d r I�QLVE— ULACI,JP a c REO gERES 0 0 0 u 0 c ,0 0 0 0 0 E1 0 0 0 a o g Oenpsr Vgitor,+e Jamaer;sting:, J FUND: erg 1 as-x r}r e� c� a4" ------Low voltoga'tactary%%erg Liao voltage factory crag. STJesd Jernpmr Sntfngs 14.LE5: J 3 75V 1, Use speckled OMAN.certified JP5 120V gloss fueelfAUL'r be 3A Rath l T120. LIMPER SETTINGS ON ON OFFOFFOFFOFFOFF J7 J6 J5 J4 J3 J2 J1 Accessories Electric accessories RTS2 Pushbutton Timer(40164) MDEH1 Low Voltage Dehumidistat(40172) EDF1 Multi-Func Ctrl(40375) EDF1 R Multi-Func Ctrl w Recirc(40393) RTS5 Pushbutton Timer(44794) EDF7 Elec Multi-Funct Dehum(44883) ECO-TOUCH®Pqrm Wall Control(44929) Accessories COM5P Supply and Exhaust Hoods(40223) MGE 5 Metal Exhaust Grill(411370) MGS 4 Metal Supply Grill(411368) MGS 5 Metal Supply Grill(411369) MGE 4 Metal Exhaust Grill(411106) FIDT 4 Insulated Flex Duct(4110611 FIDT 5 Insulated Flex Duct(411062) ' Documentation lex100H ES Service Manual.pdf(482,45kB) 27420 Flex 100H ES-VHR 100R ES IOM EN FR.pdf(5,25MB) Name:FLEX 100H ES FR.AIR APPLIANCE I Item no.:44001 3/5 Document type:Product card I Document date:2018-08-17 I Generated by:Online catalogue 0 ��,�.,... �� ,_a�►os Q,E,GNsB�`J 4� g7• RCMP �f ED Sl PRG • StGNA N' N N CO NAl n MAN OF Cl!EENSBURY f * fM( � j�s� a `�_"3� W►P �'• A SAY � ��5 li+ Zclf' O �4uc INSPECTION WORKSHEET (002944-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0491-2018 Case Module:Permit Inspection Date:Fri May 24, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Residential Final Inspection Job Address:Parcel Number:42 EAGAN RD Queensbury, NY 12804 309.17-1-9 Contact Type Company Name Name Architect George T Farnum Architect Contractor Record Time Construction Co Primary Owner Suders, Matthew Granted Permission Suders, Matthew Primary Owner Suders, Diana Applicant Suders, Matthew Checklist Item Passed Comments General Comments NO Conditions for temporary C/O- 1. Complete siding 2. Provide guard at sliding door 2nd level. 3. Complete Sheetrock @ garage. 4. Provide pressure relief valve on water heater. 5. Site plan conditions as per B Frank. 5/23/19 Final Inspection Not Approved Remaining Items: - Seal all penetrations (Ductwork, Plumbing, wiring, gaps in sheetrock and mud all screws in ceiling sheetrock) with fire caulk. - Deck structural framing connections and bracing needs to be nailed with hot dip galvanized 12 common nails. - Add lags at deck house plate as discussed. - Complete installing hanger nails in deck joist hangers. - Final Site Plan Inspection by Bruce Frank 5/24/19 Final Inspection Not Approved - Final Site Plan Inspection by Bruce Frank May 24, 2019 Page (1) INSPECTION WORKSHEET (002944-2019) Checklist Item Passed Comments 4 inch Building Number Address visible from road YES Roof Complete / Exterior Finish Complete YES Complete siding Grade away from foundation: 6" down, 10' out YES Winter conditions Attic Access 22 x 30 minimum YES Provide weather stripping at attic access Site Plan / Variance required NO Truss ID Signage Installed at Electrical Meter YES Provide truss ID sticker OK to Issue C/O NO 5/23/19 Final Inspection Not Approved Remaining Items: - Seal all penetrations (Ductwork, Plumbing, wiring, gaps in sheetrock and mud all screws in ceiling sheetrock) with fire caulk. - Deck structural framing connections and bracing needs to be nailed with hot dip galvanized 12 common nails. - Add lags at deck house plate as discussed. - Complete installing hanger nails in deck joist hangers. - Final Site Plan Inspection by Bruce Frank 5/24/19 Final Inspection Not Approved - Final Site Plan Inspection by Bruce Frank May 24, 2019 Page (2) O'Brien, John (Inspector)