Loading...
CC-0552-2018 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-0552-2018 Date Issued: Friday, December 7, 2018 This is to certify that work requested to be done as shown by Permit Number CC-0552-2018 has been completed. Tax Map Number: 296.18-1-5 Location: 63 QUAKER RD Owner: 63 Quaker, LLC Applicant: 63 Quaker, LLC This structure may be occupied as a: Commercial Alterations (dividing wall and creating 3 offices) By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the (" a4P/f ,ott" property owner of the responsibility for compliance with Site Plan, v Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: CC-0552-2018 Tax Map No: 296.18-1-5 Permission is hereby granted to: J&P Builders For property located at: 63 QUAKER RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: 63 Quaker,LLC Business Office-Alteration $25,000.00 Owner Address: 2 Fort Vaux LN Total Value $25,000.00 Watervliet,NY 12189 Contractor or Builder's Name/Address Electrical Inspection Agency J&P Builders Plans&Specifications Commercial Alterations(dividing wall and creating 3 offices) $ 578.30 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday, September 12,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensb before the xpiration date.) Dated at the Town o Queen ; e• ,e.d. _ . mber 12,2018 SIGNED BY: V \ for the Town of Queensbury. Director of Building&Code Enforcement • • L Office Use Only = IT AZT 1T1 l a PERMIT Permit#: C C v ( 11 w Permit Fee: $ 3 00., O O Town ofOpxn bwy TOWN nlNG x CODES 742 Bay Road,Queensb Invoice#: f,� P:518-761-8256 www<queensburymnet Project Location: L ` , Tax Map ID#: 2 l (g` Subdivision Name: CONTACT INFORMATION: • Applicant: 6,3 Name(s): L � f+�.� C Mailing Address, C/S/Z: t 1 (N< ("��-� (j cci ij\ &,e;r 1), 1 Cell Phone: (&: ) W---7C/10(1 Land Line: ( ) T , LI/4 lcl Email: t,` t2\ Q\ t - C • Primary Owner(s): C Names : NCVN •Oca (;)9 Mailing Address, C/S/Z: �� bQ V �� tiU `"fI---- N i 12IP1 n C& ---7 Land Line: tp 61 C/0 C7 Cell Phone: (�� ) � � � `�1 (jam ) 3�.. Email: \04\p.ce\�� i\�l • Contractor(s): Business Name: 7:kW �, r Contact Name(s): Mailing Address, C/S/Z: Cell Phone: i ) 7� � / �-t Land Line: ( • Architect(s)/Engineer(s): Business Name: Z C\IMAriAiia Contact Name(s): � MailingAddress, C/S/Z: cct1 C1tN S V- 1 )-06S- Cell Phone: ( S"l " ) "tV 3 t-13 Land Line:. ( Email: \k U• , V M,C\\(�t.,c- - cc 0/ ( -Contact Person for Buildin & Code Com liance: e, �� Cell Phone: (Sit ) C( "1— / Land Line: I ) Email: Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 • f PROJECT INFORMATION: TYPE: Commercial Residential WORK CLASS: Single-Family Two-Family Multi-Family(#of units ) Townhouse Z±9Business Office Retail Industrial/Warehouse Garage (#of cars ) Other (describe ) ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 2nd floor: 2"d floor: 3rd floor: 3rd floor: Basement (habitable space): Basement (habitable space): Total square feet: 0 Total square feet: /606•.•w ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ 491 Sr—ICOO I\i the ro osed use: � �� �2. If Commercial ro ect what s OfCce3 t-�-r �p J p p 3. Source of Heat (circle one): Gas Oil Propane Solar Other Fireplaces need a separate urning Appliances &Chimney Application 4. Are there any structures not shown on the plot plan? YES 0 'Explain: 5. Are there any easements on the property? YES ei 6. SITE INFORMATION: a. What is the dimensions or acreage of the es,rcel? p oC�.1 ti b. Is this a corner lot? YES ii c. Will the grade be changed as a r- _ ...,,,,,the construction? YES N d. What is the Ovate ce? PUBL PRIVATE WELL e. Is the parcel o SEWEf?or a PRI , SEPTIC system? Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 DECLARATION: 1. I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Nic `� A SIGNATURE: DATE: Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 FIRE MARSHAL'S OFFICE � . 1_i Town of Queensbury f 742 Bay Road, Queensbury, NY 12804 41111b— "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW Edward Jones 63 Quaker Road CC-0552-2018 8/31/2018 The following comments are based on review of drawings: • Verify fire extinguisher locations • Verify function of exit and emergency lighting • Verify paths of egress • Verify storage • CO detection required • Locks and latches shall be compliant w/Chapter 10 IFC • Provide information regarding fire alarm comments on Dwg A102 Michael J Palmer Fire Marshal 742 Bay Road Queensbury NY 12804 firemarshal@queensbury.net Fire Marshal 's Office • Phone: 518-761-8206 - Fax: 518-745-4437 firemarshal@queensbunj.net - www.queensbury.net INSPECTION WORKSHEET (FM-007796-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-0552-2018Permit Case Number:Case Module: Fri Nov 2, 2018Failed Inspection Date:Inspection Status: Gary StillmanOCC-Inspections Inspector:Inspection Type: 63 QUAKER RD296.18-1-5 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName ContractorJ & P Builders Primary Owner63 Quaker, LLC Applicant63 Quaker, LLC Granted PermissionJ & P Builders ArchitectKPB Architecture Checklist ItemPassedComments Fire MarshalYES Exit AccessYES Exit EnclosureYES Exit DischargeYES Locks and LatchesNO11/2/18 REMOVE LOCK OR PROVIDE CAP FOR INSIDE FRONT DOOR, UNABLE TO VERIFY NEW REAR DOOR (NOT INSTALLED) Sign: NormalYES Nov 02, 2018Page (1) INSPECTION WORKSHEET (FM-007796-2018) Checklist ItemPassedComments Sign: BackupYES Main Aisle WidthYES Secondary Aisle WidthYES Fire Extinguisher HungNOPROVIDE (2) FIRE EXTINGUISHERS 5 Ib. ABC AS DISCUSSED- FRONT & REAR Inspection of ExtinguisherNO Emergency Lighting InteriorYES Clearance to ElectricalYES Electrical Wiring Enclosed/LabeledNO11/2/18 CLOSE UP ALL ELECTRICAL Combustibles in Equipment RoomsYES F.D. SignageYES StorageYES Interior FinishesYES CO DetectorsNOADD CARBON MONOXIDE DETECTOR PER NYS PART 1228 as discussed Clearance to Sprinkler/CeilingYES Occupancy CycleYESB Stillman, Gary (Inspector) Nov 02, 2018Page (2) INSPECTION WORKSHEET (FM-007902-2018) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-0552-2018Permit Case Number:Case Module: Wed Nov 7, 2018Passed Inspection Date:Inspection Status: Gary StillmanOCC-Inspections Inspector:Inspection Type: 63 QUAKER RD296.18-1-5 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName ContractorJ & P Builders Granted PermissionJ & P Builders ArchitectKPB Architecture Primary Owner63 Quaker, LLC Applicant63 Quaker, LLC Checklist ItemPassedComments Fire MarshalYES Exit AccessYES Exit EnclosureYES Exit DischargeYES Locks and LatchesYES11/2/18 REMOVE LOCK OR PROVIDE CAP FOR INSIDE FRONT DOOR, UNABLE TO VERIFY NEW REAR DOOR (NOT INSTALLED) 11/7/18 CORRECTED Nov 07, 2018Page (1) INSPECTION WORKSHEET (FM-007902-2018) Checklist ItemPassedComments Sign: NormalYES Sign: BackupYES Main Aisle WidthYES Secondary Aisle WidthYES Fire Extinguisher HungYESPROVIDE (2) FIRE EXTINGUISHERS 5 Ib. ABC AS DISCUSSED- FRONT & REAR 11/7/18 Inspection of ExtinguisherYES Emergency Lighting InteriorYES Clearance to ElectricalYES Electrical Wiring Enclosed/LabeledYES11/2/18 CLOSE UP ALL ELECTRICAL 11/7/18 CORRECTED Combustibles in Equipment RoomsYES F.D. SignageYES StorageYES Interior FinishesYES Nov 07, 2018Page (2) INSPECTION WORKSHEET (FM-007902-2018) Checklist ItemPassedComments CO DetectorsYESADD CARBON MONOXIDE DETECTOR PER NYS PART 1228 as discussed 11/7/18 CORRECTED Clearance to Sprinkler/CeilingYES Occupancy CycleYESB Stillman, Gary (Inspector) Nov 07, 2018Page (3) ���D ARcy kpbirciiitecture Rr i P.O. Box 697 Lu ti; ;� �G-0 -A Clifton Park NY 12065 1`t . -t. *-) 518.429.8093 >.. kbuff@kpbarchitecture.com P • 1S tj o " Date: September 11, 2018 Re: 63 Quaker Ave—Edward Jones Office Fit-Out ADDENDUM NUMBER 1 This Addendum forms a part of the Contract Documents and modifies/clarifies the original Drawings dated August 22,2018. Comments from John O'Brien dated August 31, 2018 1. Submit a mechanical plan with new ductwork layout and heating, cooling and ventilation calculations for Edward Jones Space. Response:The following is a modification of the text on A102 to better explain the intent and criteria of the mechanical system. 'THE PASSONNO PAINT SPACE IS AN OPEN AREA THAT IS CURRENTLY SERVED FROM A DEDICATED ROOF TOP UNIT THAT SITS ABOVE THE SPACE AND FEEDS DOWN INTO THE CEILING SPACE.THE RTU IS A CARRIER MODEL#:48TME007-501 WITH A HEATING BTU OF 115,000 AND A COOLING BTU OF 71,000 WHICH OFFERS MORE THAN ENOUGH CAPACITY TO SERVE THE NEW RECONFIGURED SPACE.THE CONTRACTOR SHALL RECONFIGURE OR PROVIDE NEW DUCTWORK AS REQUIRED TO PROVIDE A MINIMUM OF 200 CFM TO EACH OFFICE SPACE.NEW SUPPLY AND RETURN DIFFUSERS SHALL BE PROVIDED FOR EACH SPACE.CONTRACTOR SHALL PROVIDE ALL NECESSARY DUCTWORK,CONNECTIONS,ACCESSORIES, OFFSETS AND MATERIALS TO FACILITATE A FUNCTIONING SYSTEM.CONTRACTOR SHALL RETAIN A TESTING AGENCY TO PRODUCE AN AIR BALANCING REPORT TO VERIFY THE SYSTEM IS OPERATING CORRECTLY.THE NEW TOILET ROOM SHALL BE PROVIDED WITH A MINIMUM EXHAUST RATE OF 50 CFM INTERMITTEN OF 70 CFM CONTINUOUS.ALL WORK SHALL BE IN ACCORDANCE WITH LOCAL CODES/ORDINANCES AND IS SUBJECT TO INSPECTION.' 2. Submit 2015 COMchecks for Lighting& Mechanicals for Edward Jones Space Response:2015 COMcheck for interior lighting is attached. 2015 COMcheck for Mechanical cannot be completed because the existing roof top unit does not meet the required minimum of 11.00 EER for the proposed system.The RTU was installed 8-10 years ago and the product data on the equipment shows an EER of 10.1.The unit does have a motorized economizer with a minimum adjustable setpoint to allow for fresh air intake and exhaust. 3. Provide name of company to perform Air Balancing Report for HVAC in Edward Jones Space. Response: Mechanical Testing, Inc. 70 Lake Ave. Saratoga Springs, NY 12866 518.450.7292 ♦f 4. Provide specifications on 1 hour fire spray to be applied at the top of the tenant separation walls. Response:There are two equal products that the contractor can use at the top of the tenant wall to maintain a 1 hr UL rated assembly.3M FireDam Spray 200-OR-Hilti Firestop Joint Spray (CFS-SP WB). Both products are acceptable for this application and product data for each is attached. 5. Review attached Fire Marshal's Plan Review. Response: Response to Fire Marshall comments follow. Comments from Mike Palmer dated August 31,2018 1. Verify fire extinguisher locations Response: Fire extinguishers shall be provided and can be verified prior to Cert.of Occ. 2. Verify function of exit and emergency lighting Response: Exit and emergency lighting can be verified prior to Cert.of Occ. 3. Verify paths of egress Response: Paths of egress can be verified prior to Cert.of Occ. 4. Verify Storage Response:Storage can be verified prior to Cert.of Occ. 5. CO detection required Response:Carbon Monoxide detection shall be provided and can be verified prior to Cert.of Occ. 6. Locks and latches shall be compliant w/Chapter 10 IFC Response: Door hardware shall be complaint with Chapter 10 of the IFC and can be verified prior to Cert.of Occ. 7. Provide information regarding fire alarm comments on Dwg A102 Response: Fire alarm comment on A102 is incorrect. Existing space does not contain a fire alarm system but rather has a single smoke detector. Based on my code research, I do not believe the new B occupancy is required to have a fire alarm system. Please confirm.Also, it is unclear to me whether a smoke detection system is required but if so, please confirm and it can be verified prior to Cert.of Occ. END OF ADDENDUM NUMBER 1 Please contact me should you have any questions. Keith P. Buff,AIA 518.429.8093 kpb Architecture T 518.429.8093 kbuff@kpbarchitecture.com • AfiCOMcheck Software Version 4.1.0.0 l Interior Lighting Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Edward Jones Investments Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 63 Quaker Ave Michael Fiacco Keith Buff Queensbury,NY 12804 63 Quaker Rd kpb Architecture Queensbury, NY 12804 PO Box 697 Clifton Park, NY 12065 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Office 1757 0.82 1441 Total Allowed Watts= 1441 Proposed Interior Lighting Power A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Office(1757 sq.ft.) LED 1:EPANL2440L35K:2X4 LITHOINIA LED:LED Panel 38W: 1 20 39 776 Total Proposed Watts= 776 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection hecklist Keith Buff-Architect 09.11.2018 Name-Title Signa e Date Project Title: Edward Jones Investments Report date: 09/06/18 Data filename: A:\2018\2018.23-63 QUAKER EJ\01.Project Management\Ed Jones.cck Page 1 of 5 s:",Kra,. dui '' _ ''!r ,:r 4- 3 _ - �, - -, k _tri,„4 ..,,'ij-''''' S '''''il-i;'-' c, . 1 tl: "%-4'.-'- , Gay�u E nnao:p ,.,r FIRE BARRIER SMOKE SEAL Ta�1 Lcc 3MTMFireDamTMSpray 200 �� � Meets eqguir SOUND BARRIER ELASTOMERIC Product Data Sheet zio y In STC 56-rated Movement wall assembly Capabity 1 . Product Description 3M-FireDam"Spray 200 is a sprayable water-based material that dries to form a tough,elastomeric coating. This material is used to firestop perimeter joints(curtain ��.,SSIp4 wall),construction joints and through penetration openings.3M'"FireDam'"Spray 200,when installed prop- erly,will help control the transmission of fire,heat,and smoke before,during,and after exposure to fire. UL LISTED FILL,VOID,OR CAVITY Available in: •■Gray •Red. FILL,VOID OR CAVITY 90G9 — MATERIAL.FOR USE IN JOINT 7, SYSTEMS,THROUGH-PENETRATION Product Features FIRESTOP SYSTEMS,AND PERIMETER CONTAINMENT SYSTEMS • Up to 4-hour fire protection in • Improved spraying pattern- sEE FIRE SRESISTANCE DIRECTOR' 90Gf. I construction joints per ASTM E 1966 applied with conventional airless LISTED de (UL 2079) spray equipment nitt�GAp0 usTED • Up to 2-hour fire protection for through • Robust jobsite formula(freeze/thaw penetration systems per ASTM E 814 resistant and uniform seal formation � c _(UL 1479)&CAN/ULC-S115 in hot or cold d in conditions) %•,. .p US g drying RAT09. US li • Highly elastic material maintains • Improved spraying for lower sag Intertek performance with up to±50% uniform coating build properties Intertek FIRESTOPSYSTEMS FIRESTOP SYSTEMS SEE INTERTEK DIRECTORY movement capabilities (stays where it's sprayed) SEE INTERTEK DIRECTORY Sag-resistant,highly • Helps minimize sound transfer* • Improved hiding power to maintain elastomeric formula for Broad range of applications proper coating thicknessigi> construction joints(airless (extensive portfolio of tested and • sprayer sold separately). p Paintable listed building and perimeter Easy water cleanup APPROVED joint systems) • SUBJECT TO THE CONDITIONS OF Meets the intent of LEER®VOC guidelines—helps reduce the quantity of indoor air contaminants that APPROVAL AS AwALL&FLOOR maybe odorous,irritatingand harmful to the comfort and well-beingofthe installers and occu ts. INSTA LED ASIRDESC WHEN .� .f f p� INSTALLED DESCRIBED IN THE CURRENT EDITION OF *Minimizes noise transfer—STC-Rating of 56 when tested in STC 56-rated wall assembly. THE FMRC APPROVAL GLIDE 2. Applications 3M'FireDam"Spray 200 is ideal for sealing perimeter joints(curtain walls),construction joints and through penetrations.Recommended for firestopping areas that require large coverage. Helps limit the spread of noxious gas,smoke and water. Helps maintain the integrity of fire-rated construction.Note:when tested at 50%movement for 100 cycles in a 4-inch joint,product remained elastomeric and did not show signs of cracking.3M-FireDam"'Spray 200 has been qualified for use as a replacement or repair material in all listed systems that specify its predecessor,3M-FireDam"Spray 100. ically Specified Division 3. Specifications This coating is tested and listed by independent Typ Tiision 7 test agencies such as U.L,ULC, Intertek. In addition, the coating has Factory Mu- tual approval.The coating complies with the current requirements of the International Section 07 84 00-Firestopping Building Code(IBC),NBCC,NFPA 5000 and NFPA 101. Section 07 84 13-Penetration Firestopping Construction Joints: Has been fire tested and evaluated under the pass/fail criteria of Section 07 8416-Annular Space Protection ASTM E 1966(UL 2079)and CAN/ULC-S 115 at the maximum extended joint width. Section 07 84 43-Fire Resistive Joint Sealants Section 07 85 53-Building Perimeter Firestopping Perimeter Joints: Has been fire tested and evaluated under the pass/fail criteria of Section 07 86 00-Smoke Seals ASTM E 2307 and CAN/ULC-S 115 at the maximum extended joint width. Section 07 92 13-Elastomeric Joint Sealants Through Penetrations: Has been fire tested and evaluated under the pass/fail criteria Section 07 92 19-Acoustical Joint Sealants of ASTM E 814(UL 1479)Standard and CAN/ULC-S 115. 3M For technical support relating to 3M Fire Protection Products and Systems,,,call:1-800-328-1687 For more information on 3M Fire Protection Products,visit:www.3m,corryfirebtop s"° �3% r y,a `a' ri.y$.5;y _ ' 4. Performance &Typical Physical Properties Colors Available: Gray or Red Unit/vol: 5 Gallon(18.9 liter)pail/ 1155.0 cu.in.(18926.9 cu.cm.) Non-Volatile Content: 65% Viscosity: 120,000 cps with shear thinning Coverage*: 12.8 sq.ft./gallon(0.31 sq.m/liter)*calculated coverage based on 1!8 in.(3 mm)thick wet coating Flash Point: None ASTM E 84: Flame Spread<25 Smoke Developed Index<50 Dry Time: <4 hour to tack free@70°F(21°C)!50%R.H. <24 hours fully dry STC Rating: 56 when installed in a 56 STC-rated wall assembly 5. Packaging, Storage, Shelf Life Packaging 3M-FireDam"Spray 200 is packaged in 5 gallon(18.9 liter)plastic pails. Storage 3M-FireDam"Spray 200 should be stored indoors in dry conditions.It is recommended that the pails of product remain in heated storage at 70°F(21°C)prior to spraying material in conditions below 40°F(4°C). Shelf Life 3M-FireDam"Spray 200 shelf life is 18 months from date of packaging when stored above 40°F(4°C). Lot numbering(e.g.8183AS):First digit=Last digit of year manufactured,second to fourth digit=Julian Date,Letters=Random to distinguish between lot numbers. 6. Installation Techniques Consult a 3M Authorized Fire Protection Products Distributor/Dealer or Sales Representative for Applicable UL,cUL, ULC,Intertek or other third party drawings and system details. Equipment In order to achieve the thickness and coverage necessary to comply with the tested systems,3M-FireDam"Spray 200 is applied using an airless sprayer. Pump requirements(minimum specifications) Flow Output:0.7 gpm minimum Liquid Pressure:2000 psi minimum Motor Size:Minimum 0.75 horsepower Recommended Tip Size:419(8 in.fan with 0.019 in.orifice)which can be changed based upon application conditions Preparatory Work Surfaces must be frost free,clean,dry and dust free. Installation Details Tested and listed system details must be followed for each specific application.Install mineral fiber insulation in accordance with system details for density,depth and compressions requirements.Note:3M'Fire Barrier Packing Material PM-4 can be used as a suitable insulation material in through penetration applications only.Apply 3M-FireDam"'Spray 200 using an airless sprayer.A nominal 1/8 in.(3mm)wet coating should be applied over the insulation,adjacent substrates and penetrant(if applicable)maintaining all required overlaps. Limitations 3M"FireDam" Spray 200 must be applied at a temperature between 40°F(4°C)and 110°F (43°C). 3M-FireDam" Spray 200 can be applied to surfaces that are 10°F(-12°C)or higher providing that the surfaces are frost free,clean,dry and dust free. 3M-FireDam"Spray 200 can be applied when the ambient air temperature is 10°F(-12°C)or higher. The drying (evaporating of water) of the 3M- FireDam" Spray 200 is affected by the ambient temperature and humidity. The lower the temperatures and the higher the humidity,the slower the 3M-FireDam"Spray 200 will dry. At 70°F(21°C)and 50%R.H.a 1/8 in.(3mm)thick wet coating is fully dried in 24 hours. At temperatures below 32°F (0°C),no drying of the 3M-FireDam"Spray 200 will occur. 7. Maintenance No maintenance is expected to be required when installed in accordance with the 3M'FireDam"Spray 200 Installa- tion Guide.Once installed,if any section of the 3M-FireDam"Spray 200 is damaged,the following procedure will apply:Any damaged product must be cut out and removed.The insulation material must be inspected to ensure no moisture is evident.The open area created must then be filled with new product,installed as detailed in the original applicable 3rd party tested and listed system.The new product must overlap a minimum 1 in.(25.4 mm) onto the previously installed product.This procedure is applicable to both current and previous formulations of 3M-FireDam"Spray 200 as well as 3M-FireDam"Spray 100(discontinued). 8. Availability 3M"FireDam"Spray 200 is available from 3M Authorized Fire Protection Products Distributors and Dealers. 3M-FireDam"Spray 200 is available in the following 5-gallon(18.9 liter)pails:Gray(3M ID Number:98-0400-5587-7),Red(3M ID Number: 98-0400-5598-5).For additional technical and purchasing information regarding this and other 3M Fire Protection Products,please call: 1-800-328-1687 or visit www.3m.com/firestop. 9. Safe Handling Information Consult country-of-use Material Safety Data Sheet(MSDS)prior to handling and disposal. Important Notice to User: Technical Information:The technical information,recommendations and other statements contained in this document are based upon tests or experience that 3M believes are reliable,but the accuracy or completeness of such information is not guaranteed. Product Use:Many factors beyond 3M's control and uniquely within user's knowledge and control can affect the use and performance of a 3M product in a particular application, Given the variety of factors that can affect the use and performance of a 3M product,user is solely responsible for evaluating the 3M product and determining whether it is fit for a Building and Commercial particular purpose and suitable for user's method of application. Services Division Warranty and Limited Remedy:3M warrants that each 3M Fire Protection Product will be free from defects in material and manufacture for 90 days from the date of purchase 3M Center,Building 223-2N-21 from 3M's authorized distributor.3M MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES,INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FORA PAR- St.Paul,MN 55144-1000 USA TICULAR PURPOSE.If a 3M product does not conform to this warranty,the sole and exclusive remedy is,at 3M's option,replacement of the 3M product or refund of the purchase price. 1-800-328-1687 Limitation of Liability: Except where prohibited by law,3M will not be liable for any loss or damage arising from the 3M product,whether direct,indirect,special,incidental or www.3M.com/firestop consequential,regardless of the legal theory asserted. Please Recycle.Printed in USA.©3M 2014.All Rights Reserved. 3M and Firedam are trademarks of 3M Company.All other Literature Order Info: 98-0213-4391-2 trademarks are the property of their respective owners. 1■■11`TI Product Information Firestop Joint Spray • (CFS-SP WB) 1ff ! 11111110 , ; • � R Product description • ■ A sprayable fire-rated mastic for construction joints where maximum movement is required ':ram Product features • Sprayable or apply by brush IN Maximum flexibility,meets 500 cycle requirements(Class II and Ill Approval)(ASTM E 1966 and UL 2079) FIIL-Tl ■ Quick and easy installation with the Titan 600 or 1100 Sprayers can help save you time and money Firestop System Identification Label ■ Contains no halogens,solvents or asbestos ■ Water based formulation so spills and over-spray clean up quickly - - - - and easily Technical Data* CFS-SP WB ■ Paintable IIMeets LEEDTm requirements for indoor environmental quality credit Density Approx.10.8 lb/gal(1.3 g/cm3) 4.1 Low Emitting Materials,Sealants and Adhesives and 4.2 Paints Color Available in red,white and gray** and Coatings Application temperature 39°F to 104°F(4°C to 40°C) Areas of application Temperature resistance -40°F to 176°F(-40°C to 80°C) ■ Top-of-wall joints Consistency Sprayable liquid ■ Curtain wall/edge of slab Chemical basis Acrylic-water-based-dispersion ■ Expansion joints Curing time Approx.24 hours @ 73°F, 50%humidity for 1/8 depth For use with Average volume shrinkage 51.1% ■ Concrete,masonry and gypsum wall assemblies (ASTM C1241) ■ Wall and floor/wall assemblies rated up to 4 hours Ph-value Approx.8-9 Movement capability Up to 50% Examples Surface burning characteristics Flame spread:15 ■ Where a gypsum wall assembly meets the underside of a metal or (CAN/ULC-5102) Smoke development:10 concrete deck Sound transmission classification 59 ■ Where a concrete floor assembly meets with non-rated exterior (ASTM E 90-99) (per tested construction type) wall(concrete,glass,etc.) Tested in accordance with ■ Where two concrete floor/wall assemblies meet •UL 2079 •ASTM E 1966 •ASTM E 84 •ASTM E 2837 •UL 1479 •ASTM E 814 •ASTM E 2307 *At 73°F(23°C)and 50%relative humidity °°Gray color requires six(6)weeks lead time FILL,VOID OR CAVITY MATERIAL ypsslF,„ FOR USE IN THROUGH-PENETRATION 4111> FIRESTOP SYSTEMS,AND/OR JOINT ®us SYSTEMS,AND/OR PERIMETER FIRE CONTAINMENT SYSTEMS APPROVED SEE UL FIRE RESISTANCE DIRECTORY 66Y7 Installation instructions for Firestop Joint Spray CFS-SP WB Notice Application of Firestop Joint Spray Firestop Joint Spray may also be brushed on with a • Before handling,read Material Safety Data Sheet and 2. Mineral wool packing:Install the prescribed back paint brush.Contact Hitti Technical Support for more product label for safe usage and health information. filling material type and depth to obtain desired information. • Instructions below are general guidelines—always rating. 4. Curing time:Allow approx.24 hours for typical refer to the applicable drawing in the UL Fire 3. Application of Firestop Joint Spray:Apply Firestop application thickness(®73°F/23°C)50%humidity Resistance Directory or Hilti Firestop Systems Guide Joint Spray to the required depth in order to obtain for 1/8"depth for the Firestop Joint Spray to fully for complete installation information the desired rating. Make sure Firestop Joint Spray cure. contacts all surfaces and overlaps beyond all 5. Identification:For maintenance reasons all Firestop Opening surrounding (Refer to UL System).Tit 1. Clean the opening.Surfaces to which Firestop Joint surfaces an Joint Spray applications can be permanently marked Sprayers have been successful in applying Firestop with an identification plate and fastened in a visible Spray will be applied should be cleaned of loose Joint Spray.Hilti recommends the use of the Titan position next to the seal. debris,dirt,oil,wax and grease.The surface should 600(for application temperatures above 50°F)or be moisture and frost free. Not for use • In areas immersed in water ,, s `41 4� tom,:41 • On hot surfaces(above 176°F) ®��` ; r ' ` :. Storage • Store only in the original packaging at temperatures .', gat Hi • 39°F to 77°F(4°C to 25°C) Observe expiration date on package 1.Clean opening 2.Pack in mineral wool 3.Spray or brush on 4.Allow Firestop Spray 5.Fasten identification plate compressed per UL Firestop Spray to cure (if required) System Hilti. Outperform. Outlast. Hilti,Inc.(U.S.)1-800-879-8000•www.us.hilti.com•en espariol 1-800-879-5000•Hilti Firestop Systems Guide RUCINSKI HALL ARCHITECTURE ����, Ronald Richard Rucinski , �� Ethan Peter Hall @ 134 Dix Avenue �J 0 Glens Falls NY 12801 Voice 518 741 0268 Fax 518 741 0274 Email ephall a©nycap.rr.com Special Inspection Report To: John O'Brien-Town of Queensbury—Code Enforcement Officer From: Ethan Hall Date: 11 September, 2018 Re: Gross Electric Office Expansion—Structure At the above referenced project location this office performed periodic on site observations of the construction including the installation of the structural sheer wall along the west wall of the building and the installation of the truss framing for the new roof. All items appear to be installed in accordance with the construction drawings and are acceptable to this office. If there are any ques . z, ease contact our office. f 4::7'SIB+- -'�' � ' --. Regards, -cam -..%1 44 � j) _ b -.:- ate' 6.._* L, Ethan P. Hall F,,-t 7,�• K ,D.,, 4-- Rucinski Hall Arc` { f= C:\!Ethan\!Al Temporary Files\Special Inspection Letter 3-Gross Electric Structure-11 Sept 2017.doc 1