Loading...
SEP-000371-2017 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 --- Community Development-Building&Codes (518)761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SEP-000371-2017 Date Issued: Thursday, December 21, 2017 This is to certify that work requested to be done as shown by Permit Number SEP-000371-2017 has been completed. Tax Map Number: 308.14-1-52 Location: 183 PITCHER RD Owner: FOREST PARK MHC,LLC Applicant: Stone Installations This structure may be occupied as a: Residential Septic Alteration 47&49 Briwood Circle By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the a; 4A property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development-Building& Codes (518)761-8256 BUILDING PERMIT Permit Number: SEP-000371-2017 Tax Map No: 308.14-1-52 Permission is hereby granted to: Stone Installations For property located at: 183 PITCHER RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: FOREST PARK MHC,LLC Septic Disposal-Residential $0.00 Owner Address: 183 Pitcher RD Total Value $0.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Stone Installations 4305 Route 50 Saratoga Springs,NY 12866 Plans&Specifications Residential Septic Alteration 47&49 Briwood Circle $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Thursday,July 5,2018 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury befojthee iration dateDated at the Town oQueens //VJe u y 5,2017 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement 4 SEPTIC DISPOSAL PE I emrmitFee: JE rm n�trZRre. ,,. 742 Bay Road,Queensbu 1 8 ✓�, OCt7'3Z)��(7 P:518-761-8256 www. e b . �'' 26 2017 (i Tax Map ID#: O I v �D Invoice#:�/NpF UProject Location: y 1 I NSBur Yes No Primary Owners) o_r k 14C, LTZ7� Mailing Address bL & Phone & Email , 169 ' 1 Co Installer/Builder 940ne 1n9t-aJW1ons Mailing Address N304T kle 6b damfwa4ni�� Phone & Email jg-5M 0 L49 Engineer Ruan Piper12 �2PJ Mailing Address Phone &E , t Contact Person for Building&Code Compliance:) LMI C /.l noh Phon :5Shr?45,7771_n RESIDENCE INFORMATION: Year Built #of bedrooms X gallons per bedroom =total daily flow Garbage Grinder Yes o 1980 or older Installed? (circle one) 1981-1991 Spa or Hot Tub Yes No 1992-Present Installed? (circle one) �0 PARCEL INFORMATION: Topography _Flat Rolling _Steep Slope _%Slope Soil Nature Sand _Loam _Clay _Other Groundwater At what depth? / Id Bedrock/Impervious material At what depth? Domestic Water Supply —Municipal _Well(if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch (test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size I _gallons(min.size 1,000 gallons,add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field with#2 stone Total length ft.; Each Trench ft. Seepage Pit with#3 stone How many: ;Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ;tank size :#of tanks NOTES:1.Alarm system &associated electrical work must be inspected by a Town approved electrical inspection agency;2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regul ions and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: Ge", Za"-Cl4ee-_ DATE: "l7 SIGNATURE: / DATE: Zd / Town of Queensb ullding&Code nforcement Revised February 2017 1. DESIGN INFORMATION SOILS INFORMATION:: SITE INFORMATION: CLARIFY ANY DESIGN LAYOUT DETAILS. SEE NOTE SHEET CALL ENGINEER TO TOPOGRAPHY AT TREATMENT FIELD IS RELATIVELY LEVEL , nFSIGN FLOW D a PER., RFO'D FNGTH OF PT = PERCOLATION TEST (LOCATIONS, SEE PLAN) x 1 »„I.A-I REDAMS �� AY ��- LATERALS DTP = DEEP TEST PIT '' a TEST PERFORMED ON 05-08-17 WITH STONE INDUSTRIES AND NYSDOH. DWEWNG SUPPLIED WITH MUNICIPAL WATER. 2.USE DIMENSIONS GIVEN: DO NOT `�--� _� � � _:�••��� ;� - 3 33d GAL/17AY 1-5 MPI 138'-25%*=103' SCALE DRAPINGS. x. i -.- DIP #3 lbtt tit ILL ELM EVEN. 0"-8' DARK SANDY TOP80ILROOTS NO ACTIVE NOGH9oRING WELLS /VI518:t #V14-1100' 0' -3 -PERMITTING/VARIANCES TO BE 4 , ^a] ±` t .i OF TREATMENT AREA. ' ;; v: T .NED BY CONTRACTOR AND/OR ��ry s`E I`• !. ;I �� 8'-24" REDDISH BROWN SAND. !\, PROPOSED. INSTALLATION FOR, EACH :HOME: I� ~-�- ° ERrir OWNER. "-` 24'-81' GRAY/TAN COURSE SAND $ TRENCH SYSTEM WITH ADS HANCOR ARC 24 CHAMBERS NO GROUNDWATER OR MOTTLING NOTED pn�� I �U J 2G 2Q17 W �� TOTAL NUMDER OF LATERALS = 5 �� o c� Q r' �( 'i1�C`T>I�CA'tI�Oft LENGTH OF EACH LATERAL. = 25'=0" I o \ ' '? f . TOTAL LENGTH OF LATERALS_ = 15' NORTH �� OF C�IJEEsvSSu �f z _ "� f PT j1 STABILIZED PERGOLA ION RAIE 1:25 MPI BU! D1 �� � 4 _ PT #2 STABILIZED PERCOLATION RATE 1:10 MPI _ .,- W Q O e`er ' r, �, ,.. • PER NYSbOH APP. 75-A(FEB 3, 2010); A 25% DEDUCTION IN O_ PROJECT LOCATION PLAN TRENCH LENGTH IS ALLOWED WITH USE OF GRAVELLESS CHAMBERS i s ► e�4•asi—o• o o t e•t�o o e 0�•• amass•• o a t�0 s®si a tem o 6 t®'6 o e�0 tr cam O W,ui z u- - - wTH 1.6SF/FT OF BOTTOM AREA & VOLUME OF 7.5GAL/FT & OPEN PROPERTY LINE AND FENCE L, co U U SIDEWALLS. TABLE 6C OF NYSDOH 'GREEN" HAND80bk. NOT TO SCALE LOCATE UTILITY LINE 10' MIN. Cr o a o z = o It is a violation of NYS education law for any person, y W CD unless he is acting under the direction of a licensed O 6 DUE TO SITE CONSTRAINTS, INDIVIDU � o o Professional dngine6r, .to alter any itefn in any way. _ Q _ ENT A RE TREATMENT TANKS.AND SEPTIC � o LOT--= .47 .-_.. ARE PROPOSED FOR EACH LOT#47 = u_�-uj - - _-_ ,-._- - .-- -- --- � ,... ._. _ AND"-#49--- -. _T,:- �---_-- - - - �----_ - -- - ' LO`f INf:ZSRI�ARTI'ON;.. LOT #4� 5 LATERALS AT 25' EACH. 2 TAX MAP : 308.14-1 -52 ADS RANCOR ARC 24 CHAMBERS. '�'.� TO QEz . QUEENSBURY SEE DETAILS. O Z C)z o z LOT SIZE:. 48.9 ACRES zo J U]0W FILE COPY (l10W wm0 < w M o P #2 BOX SOLID 4"0 SCH40 AT APPROVAL- STAMP / NOTES B /-� PER FOOT, TYP. INSTALLER TO LOCATE ALL UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. EXISTING 1000 GALLON CONC ETE TANK WITH NEW FILTER.SEE DETAILS. NEW 1000 GALLON CONCRETE — TANK WITH rILTER.SEE DET S. - - _._..._.. ..._ .. .__... 5 LATERALS AT 25' EACH. APPROVED ADS HANCOR ARC 24 CHAMBERS. _';_;,;'�N 0� Q � SEE DETAILS. For Sewage Disposal I . T s ' I DIN I"+� %" ;�; ." W ' �` ` - NEW YORK STATE DEPARTMENT OF HEALTH L1 : 2 O �e Revia `AV _ �T_ , P.E. 308.14-1-52 SEP-000371-2017 w , Forest Park MCH LLC TP L5 0�: -: Date 47 & 49 Briwood Circle Residential Septic Alteration ,- , ACTUAL SEPTIC C MPONENT LAYOUT - MAY VARY DUE TO BURIED UTILITIES. PARKING 10' MIN. LOCATE WATER LINE AND PARKING SEPTIC RPLACEM:ENT DESIGN GRAVE LLESS CHAMBER MAINTAIN 10' HORIZONTAL PROJECT:. FOREST PARK - BRIW OD IRCLE SEPARATION TO SEPTIC, TYP. — 7 & #49 LOT #4 183 PITCHER ROAD, QUEENsBURY, NY (TOWN OF QUEENSBURY) BRIa\�+/�„ .00D CIRCLE DRAWING TITLE:_ V y0F R'p RK ENGINEERING, PLLC SITE PLAN DIM AS-BUILT`TIE-1N DIMENSIONS T) MRUGGLESRD.,SARATOGASPRINGS,NY A r l� 518.581.3893 FILE NAME SITE B C D SEPTIC SITE PLAN h a t� w SCALE 1' = 20'-0' NO. SUBMITTAL / REVISION APP'D. DATE DATE MAY 2017 o D—BOX PLOT PLAN INFORMATION OBTAINED FROM WARREN COUNTY GIS A ISSUED FOR REVIEW/APPROVAL RKR s/a/n REVISION A a L1 BEGINAND AS PURPORTED BY PROPERTY MANAGER. U' x"`5 s L1 END THIS DRAWING DOES NOT REPRESENT A ND SURVEY AND MUST SOA 'HF�T LA �7950h ti o OF NOT BE CONSTRUED AS SUCH. �� �Q' C-001 L5 BEGIN _ F SSI° 2 00 a L5 END. _ MOUND TOPSOIL FOR SETTLING. PROJEGT NOTEs: SEE PLAN FOR NUMBER SEED AND COVER WITH STRAW1. SYSTEM DESIGNED IN ACCORDANCE WITH 2010 NYSDOH APPENDIX 757A. . OF LATERAL LINES 6' - 6°1 DUE TO GRADE CHANGE SEE NYSDOH'S "APPENDIX 75-A, WASTEWATER TREATMENT STANDARDS - TYP• MIN. BURIAL DEPTH WILL VARY. INDIV1bUAL HOUSEHOLD SYSTEMS"8c "NYSDOH - (GREEN) DESIGN INSTALL LATERAL END VENTS HANDBOOK" FOR ADDITIONAL DESIGN AND INSTALLATION GUIDELINES. NO IF TOP OF CHAMBER >3' DEEP. GUARANTEE ON SYSTEM PERFORMANCE OR LONGEVITY. GRAVELLESS NATIVE CHAMBER EARTH -- - 2, INFORMATION ON THESE DRAWINGS IS FOR SEP SYSTEM DESIGN BACKFILL ILL- PURPOSES ONLY. FULL TiME INSPECTIONS NOT PERFORMED. 1- = /N 11- 11- J I1=1I I-I I I 3. CONSTRUCTION SHALL BE AS SHOWN ON THESE DRAWINGS AND — I I � - _1 r iT IMT ,JI 1111 11J' 1� I�J1-1— J-�2 CHAMBER 'I—II �� I r IN ACCORDANCE WITH ALL NYSDOH AND SYSTEM MANUFACTURER'S LI I r aT II 1- IL 111 HEIGHT REQUIREMENTS. z PROPOSED GRADE, SLOPE TO DRAIN. SEED AND MULCH. 4. ALL WORK MUST COMPLY WITH LOCAL, STATE & FEDERAL SAFELY REGULATIONS, (NYSDOH, OSHA, NYSDOT). PERMITTING REQUIREMENTS ARE DO NOT SMEAR SOILS DURING N INSTALL LEVEL. REMOVE THE RESPONSIBILITY of THE OWNER. EXCAVATION. DEBRIS, RAKE FLOOR & WALLS. j�� GROUND WATER, _BEDROCK OR 5, HEAVY EQUIPMENT SHALL BE KEPT AWAY FROM THE TREATMENT FIELD. ONE CHAMBER / ` / / NO VEHICLES ALLOWED ON TREATMENT FIELD. LONGITUDINAL SECTION IMPERMEABLE STRATA 6. SMEARED TREATMENT AREA FLOORS AND WALLS ARE TO BE RAKED. PER NYSDOH APP. .75=A FEB 3, 2010; A 25% REDUCTION IN TRENCH LENGTH IS ALLOWED W17H USE OF e� 7. TREATMENT HELD SHALL BE GRADED TO SHED RAINFALL AND TO GRAVELLESS CHAMBERS WITH 1.6SF/Fr OF BOTTOM AREA ADS HANCOR ARC 24 CHAMBER MODEL DIVERT SURFACE RUNOFF FROM ADJACENT AREAS; & VOLUME OF 7�56AL/FT & OPEN SIDEWALLS Ap_ TR EICH�_M t, T E . 8-. RECOMMENDATION: DOWNSLOPE O2 SHALLOW L TW ELLS SHOULD_ HAVE -UV TREAl1i1ENT dR CIiL'ORINAlT75N AND FILTRATION SYSTEM-INSTALLED: -`- SCALE: NTS WELL WATER QUALITY SHOULD BE TESTED PERIODICALLY. 4PRECAST SNK r-T-�- ==- 24•' DIA 9, INSTALL EFFLUENT FILLER IN SEPTIC TANK, (POLY-�°LOK PL-122) WITH C I I I I I A RISER OR EQUAL. I �-F,I I INLET �- II �"�A J - - OUTLET10. GARBAGEGRINDERS AND WATER TREATMENT SYSTEM SHALL NOT ATTACH TO SEPTIC. NO SUMP PUMP DISCHARGE ALLOWED. LEAKING FIXTURES WILL CAUSE FAILURE OF SEPTIC SYSTEM. INLETOUTLET PROVIDE EFFLUENT FILTER. SEE NOTES. APPROVAL STAMP / NOTES INSTALL RISER & EFFLUENT FILTER (POLYLOK PL3-122) It is a violation of NYS education law for any person, LOCKABLE COVER, TYP unlese he is acting under the direction of a licensed 1-1//2 professional engineer, t8 alter any item in any wdy> COf(CRETE BAFFLE BACKFILL WITH CLEAN OR EQUAL BASE I gLNISHED GRADE REMOVABLE COVER IN 8 ISELIFTS AND TAMPED EFFLUENT FILTER TOP SOIL. SEED & MULCH r4, ; WATERPROOF SEAL 12IN vet � t a ,. POLY RISER IN INVERT �7s �t r�ee � '. c ..E ii �I III.I I SII I I' II ILII i " U 2' ABQ.VE r i.n s`i;it s�'6 �'1 (1,4� }j Sp INLET I °u INET ( OUTLET NEW YORK S: A` 'DEPARTMENT GE HEALTH iiVLEr — I I. cauLKEo cAuu<ED Glens Falls nistnCt Officefi r .3� —� °.. 1p ,. .. TLET JOINT QuIr J61NT Refer to first sheet for approved date and signature. + TEE W/ i l SANITARY SANITARY EFFLUENT FILTER Imo! o n l' 2" MIN. TEE 4 uLlc{,EAo ' 3' MIN 12" MIN CLEAN SAND, PEA e L ATL 11-��iIf 1 GRAVEL OR AGGREGATE u tiu=i -t r r�TNrYa (3/4" - 1 1/2") o X63 �6'-o-�d p •.. o �--�•,"��,,�• IF DESIGNED TO USE EXISTING SEPTIC,TANK, PUMP OUT AND INSPECT EXISTING TANK. PROVIDE WRITTEN REPORT TO ENGINEER, SYSTEM COMPONENTS SHALL BE SEPTIC REPLACEMENT. DESIGN GRAVELLESS CHAMBER 1. MINIMUM TANK CAPACITY AS FOLLOWS: MAINTAINED. TANKS SHALL BE PUMPED 1. PIPE JOINTS TO BE SEALED LIQUID !IGHT. OUT AND INSPECTED EVERY 2 YEARS FOREST P BRIWO D CIRCLE - FOR 3 BEDROOMS OR LESS TANK SHALL BE 1,000 GALLONS, WITH OR LESS FOR OPTIMAL PERFORMANCE; PRO,ECT•. 27 S.F. SURFACE AREA. 2, SPEED LEVELING DEVICES SHALL BE USED ON ALL - 4 BEDROOMS SHALL HAVE A 1,250 GALLON TANK WITH 34 S.F. F_FFLUENTFILTER (IF INSTALLED) SHALL LOTS #47 & #49 OUTLET PIPES. SURFACE•AREA: B E CHECKED AND. CLEANED - FOR EACH ADDITIONAL BEDROOM ADD 250 GALLONS & 7 S.F. REGULARLY. OTHERWISE PREMATURE 3. SEPTIC TANK TO D-BOX: 4" PVC OR SOR21, LIQUID SURFACE AREA. FAILURE COULD 0 C C U R. 183 PITCHER ROAD, QUEENSBURY, NY (TOWN OF QUEENSBURY) TiGHT JOINTS, MIN. SLOPE 1/8" PER FOOT - FOR HOT TUB/SPA AND/OR GARBAGE GRINDER ADD 250I. GALLONS TO TANK SIZE FOR EACH. 4, THE SLOPE OF OUTLET PIPES BETWEEN THE DRAWING,TITLE: DISTRSHO IBUTION 19E SLOPED bISTRIBUTI1/32 LAPET FOOT 2. BUILDING TO SEPTIC TANK: 4" PVC SCH. 40 PIPE, LIQUID TIGHT'JOINTS, SOF W RKEN.GINEERING, DETAILS LEASTMIN. SLOPE 1/4' PER FOOT. K , PLL AND CONSTRUCTED OF 4" PVC SCH. 40 OR SDR21 225 RUGGLES RD.,SARATOGA SPRINGS,NY WITH LIQUID TIGHT JOINTS. 3. SEPTIC TANK TO D-BOX OR PUMP TANK: 4" PVC SCH. 40 PIPE OR Gj l 518.581.3893 FILE NAME DETAILS SDR21. LIQUID TIGHT JOINTS. MIN. SLOPE 1/8" PER FOOT. '�� SA r` 5. USE DOUBLE SIDED STICKING RUBBER BUM FOR W SCALE AS NOTED DOSED SYSTEMS. 4. SEPTIC TANK TO CONSTRUCTED PER NYSDOH GUIDUNES. ` NO. SUBMITTAL / REVISION APP'D. DATE DAiS MAY 2017 N_I NEW. CONCRETE FOR LOT .47 PROVIDE f (� a ISSUED FOR REVIEW/APPROVAL RKft s/s/n REVISION A DISTRIOUTION BOX NEW 100 GAL CONCRETE SEPTIC TANK �d SHEET �a00 a SCALE NONE SCALE: NONE PUMP OUT & INSPECT A�CFESSIO��~ C-100 2 OF USE EXISTING 10.00 GAL TANK AT LOT :49 2 DESIGN INFORMATION -� f SOILS I _............ -_ GENERAL NOTES: � . SITE INFORMATION:t ` INFORMATION: I 1. SEE NOTE SHEET. CALL ENGINEER TO CLARIFY ANY DESIGN LAYOUT DETAILS DESIGN FLOW DESIGN PERE. i REQ'D LENGTH DF PT — PERCOLATION TEST (LOCATIONS, SEE PLAN) TOPOGRAPHY AT TREATMENT FIELD IS RELATIVELY LEVEL, BEDRMS_ GAL./DAY BAS 1 LATERAL i 3 330 GAL./DAY 1-5 MPI 13 DTP = DEEP TEST PIT s > INDUSTRIES AND NYSDOH DWELLING SUPPLIED WITH MUNICIPAL WATER. 2.USE DIMENSIONS GIVEN: DO NOT ON 05-08-17 WITH STONE s 8' 03 SCALE DRAWINGS 111 1 TEST PERFORMED ON PLANtUK Lui:AYIUN.I .. . .., ._... h X • i 0"-8" DARK SANDY TOPSOIL.ROOTS NO ACTIVE NEIGHBORING WELLS NOTED/VISIBLE WITHIN 100' 3,ALL PERMITTING/VARIANCES TO BE l y1"� i' PROPOSED INSTALLATION F0 OBTAINED BY CONTRACTOR R tn)s 8"-24" REDDISH BROWN SAND. OF TREATMENT AREA. r r R EACH HOME: 24"-81" GRAY/TAN COURSE SAND = PROPERTY OWNER. 1' TRENCH SYSTEM WITH ADS HANCOR ARC 24 CHAMBERS NO GROUNDWATER OR MOTTLING NOTED TOTAL NUMBER OF LATERALS = 5 LENGTH OF EACH LATERAL = 25'-0" rMOO=WCAIM •:.' ",4 TOTAL LENGTH OF LATERALS = 125' RCNORTH - '..- - �l TABILIZED PEOLATION RATE: 1:25 MPI PT #2 STABILIZED PERCOLATION RATE: 1:10 MPI WITH 16SF/FT OF BOTTOM AREA & VOLUME OF 75GAL/FT &AVELLESS BOPEN- �11i + u4 IIPROPERTY®LINE AND FENCE ®� ®. ®® v® PROJECT REDUCTIONTRENCH LENGTH IS ALLOWED WITH USE OF LOCATION PLAN SIDEWALLS. TABLE 6C OF NYSDOH "GREEN" HANDBOOK. LOCATE UTILITY LINE 10 MIN. , NOT TO SCALE DUE TO SITE CONSTRAINTS, INDIVIDUAL It is a Violation of NYS education law for any person, e / unless he is acting under the direction of a licensed Ll TANKS AND SEPTIC TREATMENT AREAS professional engineer, to alter any item in any way. ARE PROPOSED FOR EACH LOT#47 LOT #49 L5 AND #49 5 LATERALS AT 25' EACH. 25 LOTINFORMATIoN' ADS HANCOR ARC 24 CHAMBERS. SEE DETAILS. ��� z®� TAX MAP #: 308.14-1'-52 Z07i z0-1 TOWN 'OF QUEENSBURY I=W_j In0W (npW XLj3. XW�i -Box wm� 48.9 ACRES LOT SIZE w m® SOLID 4"0 SCH40 AT - P #2 APpRov a�,, 0 PER FOOT, TYP. STAMP / NOTES EXISTING 1000 GALLON CONI E� TE INSTALLER TO LOCATE ALL UNDERGROUND TANK WITH NEW FILTER.SEE DETAILS. D—BOX C NEW 1000 GALLON CONCRETE UTILITIES PRIOR TO CONSTRUCTION. 1 1 TANK WITH FILTER.SEE DETAILS. 5 LATERALS AT 25' EACH, LOT #47 _ ADS HANCOR ARC 24 CHAMBERS. SEE DETAILS. (� F T#I IJ l,�! 25' DEC 2 0 2017 LOT 47 CTP#1 L1 .. •...,AS—BUILT TIE—IN DIMENSIONS ENSIO C®(FT).... TOWN C7i~QUEENSBURY D BUILUI�!(3 c CODES T. ACTUAL SEPTIC COMPONENT LAYOUT MAY VARY DUE TO BURIED UTILITIES. D—BOX 26.5 48.5 PARKING 10' MIN. PARKING L1 BEGIN 24.5 48 L1 END 12 72.5 -- __- 3 SEPTIC FORESZAcPARK DESIGN BRTWOODL CIRCLE ESS CHAMBER L5 BEGIN 41.5 58 ———--—_______ PRo,1ECT: D 5 79 — _ ----------------- - LOT #47 & #49 RI V V/��O O CIRCLE 183 PITCHER ROAD, QUEENSBURY, NY (TOWN OF QUEENSBURY) LOT 49 ..•.. •.•(FT) DRAWING TITLE, ,... EVtBNEEiING' P� � C SITEPLAAS—BUILT TIE—IN DIMENSIONS K A B C D 225 RUGGLES RD.,SARATOGA SPRINGS,NY. E„I„ ®„ S TE„ - - SEPTICi ' ~ 518.581 3893 FILESC „ n �1 PLAN 1 JAI Z ALE I 1” = 20'—Q" w PL INFORM IO PROPERTY FROM MANAGER. COUNTY GIS f E i 0. t NO, ISSUEDFORTREVIEW/APPROVAL RKR �8/E DATE I MAY 2017 D—BOX 46.5 38.5 / l AND AS L1 BEGIN 51.5 42.5 OT PLAN FORMATION OBTAINED U _ L1 END 73 32,5 THIS DRAWING DOES NOT REPRESENT A LAND SURVEY AND MUST = tai �� 17 N I ... •• � � - ��9 S®�` 1, 1 _ RECORD DRAWING _RKR a/31/n = REVISION 1 SHEET � 00 L5 BEGIN 41.5 28 NOT BE CONSTRUED AS SUCH. �A� P � a— END,, 57 9 °�Ess1Q� — of ..w..�,-.—..�.�..�,�..._W-.Y. � � C 001 1 • 2 q MOUND TOPSOIL FOR SETTLING. PROJECT NOTES: SEE PLAN FOR NUMBER SEED AND COVER WITH STRAW. 1. SYSTEM DESIGNED IN ACCORDANCE WITH 2010 NYSDOH APPENDIX 75-A. OF LATERAL LINES g' g" DUE TO GRADE CHANGE SEE NYSDOH'S "APPENDIX 75-A, WASTEWATER TREATMENT STANDARDS - TYP. MIN. BURIAL DEPTH WILL VARY. INDIVIDUAL HOUSEHOLD SYSTEMS"& "NYSDOH - (GREEN) DESIGN I INSTALL LATERAL END VENTS HANDBOOK" FOR ADDITIONAL DESIGN AND INSTALLATION GUIDELINES. NO GRAVELLESS �, NATIVE IF TOP OF CHAMBER >3' DEEP. GUARANTEE ON SYSTEM PERFORMANCE OR LONGEVITY. CHAMBER EARTH � _ 2. INFORMATION ON THESE DRAWINGS IS FOR SEPTIC SYSTEM DESIGN BACKFILL III- PURPOSES ONLY. FULL TIME INSPECTIONS NOT PERFORMED. ; I—III- I—III- -III_ III- -III—I I I I I-1 _ — I—I — — —11=1 — — — —_— I » — 1=1 1 I =_I 3. CONSTRUCTION SHALL BE AS SHOWN ON THESE DRAWINGS AND (=III=III=11' L=1 I=1 IJ I' =1 I H I1=III=1I-III =III-12 CH AM BER =I i(=1 - _— 1=III IN ACCORDANCE WITH ALL NYSDOH AND SYSTEM MANUFACTURER'S HEIGHT —I i I-1 REQUIREMENTS. ? PROPOSED GRADE, SLOPE TO :2 DRAIN. SEED AND MULCH. 4. ALL WORK MUST COMPLY WITH LOCAL, STATE & FEDERAL SAFETY S' REGULATIONS, (NYSDOH, OSHA, NYSDOT). PERMITTING REQUIREMENTS ARE DO NOT SMEAR SOILS DURING N INSTALL LEVEL. REMOVE THE RESPONSIBILITY OF THE OWNER. _ EXCAVATION, I _ GDEBRIS RAKE FLOOR & WALLS. - �— ,. � i ROUND WATER, BEDROCK OR 5. HEAVY EQUIPMENT SHALL BE KEPT AWAY FROM THE TREATMENT FIELD. ONE CHAMBER . ,�/ %`/ ,/ /%% �� NO VEHICLES ALLOWED ON TREATMENT FIELD. LONGITUDINAL SECTION IMPERMEABLE STRATA 6. SMEARED TREATMENT AREA FLOORS AND WALLS ARE TO BE RAKED. PER NYSDOH APP. 75-A(FEB 3, 2010); A 25% REDUCTION IN TRENCH LENGTH IS ALLOWED WITH USE OF 7. TREATMENT FIELD SHALL BE GRADED TO SHED RAINFALL AND TO ! GRAVELLESS CHAMBERS WITH 1,6SF/FT OF BOTTOM AREA ADS HANCOR ARC 24 CHAMBER MODEL DIVERT SURFACE RUNOFF FROM ADJACENT AREAS, & VOLUME OF 7.5GAL/FT & OPEN SIDEWALLS. GRALLESS CHAMBER TRENCH TREA ENT SEI✓ 11®N 8. RECOMMENDATION: DOWNSLOPE OR SHALLOW WELLS SHOULD HAVE .... .,,,...W...._ , .......e_ ,._,._....,..,W...._.._.� UV TREATMENT OR CHLORINATION AND FILTRATION SYSTEM INSTALLED. SCALE: NTS WELL WATER QUALITY SHOULD BE TESTED PERIODICALLY. 4PRECAST TNK r-r�---------- I I /�24" DIA 9. INSTALL EFFLUENT FILTER IN SEPTIC TANK, (POLY-LOK PL-122) WITH C I I I I I / A RISER OR EQUAL. INLET III ry/ OUTLET 10. GARBAGE GRINDERS AND WATER TREATMENT SYSTEM SHALL NOT ATTACH I I I I I \ TO SEPTIC. NO SUMP PUMP DISCHARGE ALLOWED. LEAKING FIXTURES WILL CAUSE FAILURE OF SEPTIC SYSTEM. W............ ...... .. INLETOUTLET FIRURDESEE NOTES. q APPROVAL STAMP / NOTES INSTALL RISER EFFLUENT FILTER (POLYLOK PL— 122) It is a violation of NYS education low for any person, LOCKABLE COVER, TYPunless he is acting under the direction of a licensed 1-1 2" professional engineer, to alter any item in any way. CONCRETE BAFFLE BACKFILL WITH CLEAN -FINISHED GRADE OR EQUAL REMOVABLE COVER ON-SITE MF01 DL TAMPED -Fl _ IN 8 INCH LIFTS EFFLUENT FILTER—� / IOP SOIL, SEED & MULCH COVER I WATERPROOF SEAL 'Y/%" %\\/: x 12" MIN 1 POLY RISER r. r <` `:.• INLET INVERT III j l I N v INLET. ) t ' OUTLET INVERT OUTLET CAULKED--/ / JOINTED INLET OUTLET JOINT ` - 111��� SANITARY o o LES SANITARY TEE W/ _ -IIIA 2" MIN. TEE I uLKHEAD a EFFLUENT FILTER = - - b° t —� 3" MIN 12" MIN. — / - - CLEAN SAND PEA _ - ° R AGGREGATE /�/�/��///////��� GRAVEL 0 �IIIj;1�!I--lit-111=Iii=lil-lir=lir11=u1-IL (3/4" - 1 1/2") - - ,- _ ,.. ._ - ,. _ - IF DESIGNED TO USE EXISTING SEPTIC TANK, PUMP OUT AND INSPECT 1 EXISTINGTANK. 7ANKROVIDE CAPACI IAS FOLLOWS:REPORT TO ENGINEER. SYSTEM COMPONENTS SHALL BE ` OUTAAINEND D. TANKS INSPECTED EVERY BE2PUMPED YEARS 11 "'SEPTIC REPLACEMENT 'DESIGN GRAVELLESS CHAMBER 1. PIPE JOINTS TO BE SEALED LIQUID TIGHT. FOR 3 BEDROOMS OR LESS TANK SHALL BE 1,000 GALLONS, WITH OR LESS FOR OPTIMAL PERFORMANCE; FOREST PAIL I RK BRIWOOD CIRCLE 27 S.F. SURFACE AREA. }�}}} �7 p �-} (� 2. SPEED LEVELING DEVICES SHALL BE USED ON ALL - 4 BEDROOMS SHALL HAVE A 1,250 GALLON TANK WITH 34 S.F. EFFLUENT FILTER (IF INSTALLED) SHALL - LOTS t7� 1 (x TT�J OUTLET PIPES. SURFACE AREA BE CHECKED AND CLEANED - FOR EACH ADDITIONAL BEDROOM ADD 250 GALLONS & 7 S.F. REGULARLY. OTHERWISE PREMATURE 3. SEPTIC TANK TO D-BOX: 4" PVC OR SDR21, LIQUID SURFACE AREA. FAILURE COULD OCCUR . 183 PITCHER ROAD, QUEENSBURY, NY (TOWN OF QUEENSBURY) TIGHT JOINTS, MIN. SLOPE 1/8" PER FOOT. - FOR HOT TUB/SPA AND/OR GARBAGE GRINDER ADD 250 4. THE SLOPE OF OUTLET PIPES BETWEEN THE GALLONS TO TANK SIZE FOR EACH. DRAWING ' -.111111111111111h M AV TITLE. DISTRIBUTION BOX AND DISTRIBUTION LATERALS 2, BUILDING TO SEPTIC TANK: 4" PVC SCH. 40 PIPE, LIQUID TIGHT JOINTS, ®F NE \,�j K 7 � 225 RUGGLES RD.,SARATOGA SPRINGS,NY SHOULD BE SLOPED AT LEAST 1/32" PER FOOT DETAILS AND CONSTRUCTED OF 4" PVC SCH. 40 OR SDR21 Q, _ LS WITH LIQUID TIGHT JOINTS. 3. SEPTIC TANK TO D-BOX OR PUMP TANK: 4" PVC SCH. 40 PIPE OR C•j Q' l 518.581.3893 MIN. SLOPE 1/4" PER FOOT. � ENGINEERING, P�L.� ~y�o FILE NAME DETAILS SDR21, LIQUID TIGHT JOINTS, MIN. SLOPE 1/8 PER FOOT. �� r SCALE AS NOTED o I 5 DOSEDUSE OUBLE SYSTEMS.ED STICKING RUBBER BUM FOR �y4. SEPTIC TANKTO CONSTRUCTED PER NYSDOH GUIDLINES. r�� ! # � rlo suBMlrrnL / REVlsiorl InP o DATEjVd - DATE � MAY 2017 CJ � NEW CONCRETE FOR LOT#47 PRO YI®E �� E • (5 A ; ISSUED FOR REVIEW/APPROVAL RKR 5/8/17 - xce�s�oa �y _ - - I - R SEPTIC TANK S a o 4 d �, O� _ 1 RECORD DRAWING RKR e/31/tt = FREVISION � DIS lBUTION .BOX .. NEW 1®0, . GAL CONC..°.,�.��.......___. ._......... .....a = ,� 9s v SH EET iia _ SCALE N „ 0 0 -t4 F - — _.. PELT �FESSID NONE PUMP OUT & INS USE EXISTING 1000 GAL TANK AT LOT, _ -..�...�.�..c goo G .. 2