Loading...
RC-0663-2018TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: RC-0663-2018 Date Issued: Friday, February 1, 2019 This is to certify that work requested to be done as shown by Permit Number has been completed. RC-0663-2018 Tax Map Number: Location: Owner: 295.15-2-1 26 JOHN CLENDON RD FOOTHILLS BUILDERS, LLC FOOTHILLS BUILDERS, LLCApplicant: This structure may be occupied as a: Single Family Dwelling 1823 s.f. Garage 440 s.f. Lot 1 By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board or Zoning Board of Appeals. Director of Building & Code Enforcement IOW TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-0663-2018 Tax Map No: 295.15-2-1 Permission is hereby granted to: FOOTHILLS BUILDERS,LLC For property located at:26 JOHN CLENDON RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: FOOTHILLS BUILDERS,LLC Single Family-New 200,000.00 Owner Address: 9 Mountainside DR Total Value 200,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency FOOTHILLS BUILDERS,LLC 9 Mountainside DR Queensbury,NY 12804 Plans&Specifications Single Family Dwelling 1823 s.f. Garage 440 s.f. Lot 1 721.90 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday,October 31,2019 If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before t expiration d-to. Dated at the Town f Quee ury; 4W4 (y.October 31,2018 SIGNED BY:for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only 1 Permit#: r\C ~`(( "G r PRINCIPt.g rktic rvl E_ t.l hi+m p ._ `ON Permit Fee:. 71 Rec. Fee: S N Pi 742 Bay Road Queensbury. NV 12$04 P 518-;6'1-8255 invoice#: 0 7/o 1 Project Location: __2,Ce To W N C1.:0 6;) KD Tax Map #: 2.9c P r - 2- - I Subdivision Name 56 OP (L(N')6i.' A1Dpf.1 e i41€! TOWN BD RESOLUTION 86- 013 S850 recreation fee for new dwelling un dup two-family multiple€amity _ t and manufactured homes : not homes This is in addition to the permit fee(s). CONTACT INFORMATION: Applicant: Name(s): c o T H I L-(_S 3 LL I Ltd E S (3O C Lev,cl t Mailing Address, C/S/Z: ` m c u N TR 1-)Li I 2.t-c Cell Ph.: I ( s i ) 7`1 i t t 33 L- -Une: t (c t ' ) -1i6-3S2c.' Email: Fc c T f-E t c.,t.. t.--DE RS hf y Ls' t /Y1 L - c c ;\ Primary Owner(s): Name(s): SA016 OS ri ?pc_l c. fl i Mailing Address. CIS/Z: Cell Ph.: ( Land Line: ( Email: Contractor(s): Name(s): S AS P P L r N T w Mailing Address. C/S/Z: Cell Ph.: ( Land Line: ( Email: Architect(s)/Engineer(s): Name(s): _ PAN . PE Lvsic Mailing Address. CIS/Z: G-LCN 5 i cvo Tc: .C L L-t_5 '- ti )2-1c Cell Ph.: ( Land Line: l ( 5't ) 2. .- 9 2-CQy Email: DR..i Y l 51 or.) EN A 1 L. Contact Person for Building & Code Compliance: 306: LC Cell Ph.: I (S"t ) 1 l - 19 33 Eaftel Line: i ( 1? ) 3S"U (4_6-1-0 Email: EGc 4 t-k t L-LS t?)ti. 1 Li) }ZS Pi 1 C-Pn f1 t , (...c ofN TnC)Pc "._?`r it f:efnr r.. ! rt',r,Sir:t;?t:r. Rts,spci?,+1.i 'r,.R SEPTIC DISPOSAL PERMIT APPLICATI ON nay Pca:: Qu -n bury t P518 .76 5() P,:rm 1ZC. - 0(..ccc) , Ta M-:p lD + t Project_Location: Primary Owner(s)T0 CT i-t t Lt..S I L 1)E-AZ LIA. C..vci c L e v; e--i Mailing Addres sI CI tll c u r./i to 1 t•, rue .P., C.to E n,: aL,t.`'-; 1"J l2X i.' `f Phone & Email et t I Installer/Builder So i-1 t1F Pc-IC iv\)T Mailing Address s . 1 Phone & Email 1 1 Engineer Itr Le c.R e.c Mailing Address N D, 1.4A y-t LA Ai Phone & Email T Contact Person for Building&Code C c:mpitiancca: ICe Le ( Phc)rre: ( 1 C)Ti 1 - I13-3 RESIDENCE NFORMATION: Year Built of bedrooms X gallons per bedroom E = totaldaily flow ' Garbage Grinder Yes 1980 or older Installed? {Circle one) Spa or Hot Tub Yes No 1981-9 1 I Installed? {circle one; 1192-Present 3 ilD 33 PARCEL NFORMATION: Topography 0( Flat Rolling Steep Slope Slope Soil Nature Sand Loam Clay __Other- Groundwater At what depth? J f'4 Bedrock/Impervious material At what depth? i./M Domestic Water Supply X_ Municipal -__ Well {if well.water supply from any septic system absorption is__ It.i Percolation Test Rate I-c per minute per inch{test to be completed by licensed engneeriarcrect) PROPOSED SYSTEM FOR NEW CONSTRUCTION Tank size ID 0 Q gallons{min,size 1000 gallons.add 250 ga lions for each garbage cylinder or spa'hot tub System Absorption field with#2 stone Total length 1 'Q ft.:EachTrench 5-C It. i Seepage Pit with#3 stone How many. Size: li. Alternative System Bed or other type I 1 HoldingTank Systen-,Total required capacity? tank size of tanks NOTES: 1 Alarm system&associated eiectricalwork must be inspected by a Town approved electrical inspection agency.2 We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file-no exceptions Declaration Any permit or approval granted which is based upon or is granted in reliance upon any inater sal representation or failure to make a material fact or circumstance known by or on behalf of an applicant shall be vcw:.i.l have read the regutatsons and agree to abide by these and all requirements of the Town of Ouetinsbur y Sanitary Sewage Disposal Ordinance. 5- PRINT NAME: pS CPit L.G I DATE------ -- i Lilt - -- r DATE R SIGNATUR u t L"--- Town of Queensbury Thomas R.Van Ness Highway Department Highway Superintendent 742 Bay Road,Queensbury, NY 12804 Home:518-745-0929 Phone:518-761-8211 Fax:518-745-4466 David Duel! Deputy Highway Superintendent Home:518-745-0938 DRIVEWAY PERMIT Date: Applicant Name: FCC z N (LA S P 3 C YC e' '-eu L l ) Telephone No.: Cs t `1 ci ) - c 1 J ( S)?) 7 i G-. Si,6\ Address to be Inspected: Z,( TO L i N D o d ! Return Address: me"^s T-) S DST tAe-ENc c,1`14 ) Z$L 1 Applicant must show exact location and width of driveway(s)to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: Preliminary approval NEED Slight Swale Deep Swale Level with the road Level with the top of the paved wing Size culvert pipe to be used (if necessary) 12" 15" 18" 24" 36" Preliminary inspection completed by:Date: Approval by Highway Supt.: or Deputy Supt.: Upon completion please resubmit this approval permit for a final approval. STEP 2: Final Approval j Rejected Date: Thomas R.Van Ness, Highway Superintendent David Duel', Deputy Highway Superintendent Town of Queensbury Building&Code Enforcement Principal Structure Application Revised February 2017 INSPECTION WORKSHEET (000724-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0663-2018 Case Module:Permit Inspection Date:Fri Feb 1, 2019 Inspection Status:Passed Inspector:John O'Brien Inspection Type:Residential Final Inspection Job Address:Parcel Number:26 JOHN CLENDON RD Queensbury, NY 12804 295.15-2-1 Contact Type Company Name Name Granted Permission FOOTHILLS BUILDERS, LLC Applicant FOOTHILLS BUILDERS, LLC Primary Owner FOOTHILLS BUILDERS, LLC Contractor FOOTHILLS BUILDERS, LLC Checklist Item Passed Comments General Comments YES Attic access has gaps replace with new panel Grade away from foundation 6 with 10 feet YES Winter conditions grade to be completed in spring 6 clearance to sill plate YES Winter conditions grade to be completed in spring Attic Access 22 x 30 minimum YES Replace access cover As Built Septic System YES OK to Issue C/O YES 2/1/19 Final Inspection-Ok to Issue CO! Feb 01, 2019 Page (1) O'Brien, John (Inspector) NORTH EAST BUILDING PERFORMANCE ADVISORS Serving the Capital District, Saratoga and Adirondack Regions January 30, 2019 7 Rocky Ridge, Warrensburg, NY 12885 Foothill Builders LLC 9 Mountainside Drive Queensbury, NY 12804 RE: Blower Door Test for NYS Building Code, Town of Queensbury Mr. Joseph Leuci: After inspection of the New 2Story Home at 26 John Clendon Rd, Queensbury, New York and completion of a Blower Door Test consistent with the practice of depressurization to 50 Pascal in awinter condition with the exterior windows and doors shut and the interior doors to all the rooms open, my observations are as follows: This home tested passed the current New York State Building Code for Air Changes per Hour @ 50 Pascal of less than or equal to 3 ACH/50 (for Homes permitted after stNovember1, 2016). The tested number is 2.96 ACH/50 Pascal. The total volume of conditioned space at 26 John Clendon Rd. is 23996 cubic feet taking into consideration all conditioned space inthe home. The cubic feet per minute @ 50 Pascal was 1184 CFM/50. The height correction factor for New York State is 15.4 for a two story building, as such the tested home @ 26 John Clendon Rd. has the natural rate of air exchange of 0.192 air changes per hour/natural or 76cfm natural infiltration credit based on the blower door test. In the latest (2013) version of ASHRAE 62.2, high-performance homes need to be ventilated at 7.5 cfm per bedroom + 1, plus 3 cfm per 100 square feet. That means for 3+1 bedrooms it would need 2026 sq ft/100 times 3 cfm= 61 cfm + 30 cfm or 91 cfm total. It would also be advantageous to use the bathroom and kitchen fans to help control humidity and improve indoor air quality. My credentials are as follows: BPI Certified Building Analyst BPI Certified Envelope Specialist BPI Certified Heating Professional If you have any questions regarding my findings please feel free to contact me. Sincerely, 1.888.472.2774 7 Rocky Ridge Road 4A Vatrano Drive Warrensburg, NY 12885 Albany, NY 12205 Phone (518)623.7016 Phone (518)350.2941 Fax (518)623.7015 Fax (518)694.0102 IL' wr z_67‘7-' t r EXHAUST SYSTEMS o e-, Q6 ‘ .1,,,,tL r'-e'L/ i' TABLE MISOT.3.3(1) r:: CONTINUOUS WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATE REQUIREMENTS t DWELLING UNIT NUMBER OF BEDROOMS FLOOR AREA 0-1 2-3 I 4-5 6-7 i 7-- 6„:;. feet) square Airflow in CFM 1,500 30 45 60 75 p 1', 1,501-3,000 45 60 75 90 105 3,001—4,500 60 75 90 105 120_ 4,501—6,000 75 90- 105 120 135 4LL • 6,001—7,500 90 105 120 135 150 j 7,500 105 120 V 135 150 165 a .,,;_ For SI:1 square foot=0.0929[n2,1 cubic foot per minute=0.0004719 m3/s. j'P•wr.:,• TABLE M1507.3,3(2) 4yy}''' INTERMITTENT WHOLE-HOUSE MECHANCAL VENTILATION RATE FACTORSa,b r.- RUN-TIME PERCENTAGE IN EACH 4-HOUR 5,0 75%i_zi:`` SEGMENT 1 y..''.`Factor$ 4 3 2 1.5 1.3 f a.For ventilation system run time values between those given,the factors are permitted to be determined by interpolation. yy:'` b.Extrapolation beyond the table is prohibited. TABLE M1507.4 M1507.4 Local exhaust rates.Local exhaust systems shall MINIMUM REQUIRED LOCAL EXHAUST RATES`F i!. be designed to have the capacity to exhaust the minimum air ONE-AND TWO-FAMILY DWELLINGS ';`_ flow rate determined in accordance with Table M1507.4. AREA TO BE EXHAUST RATES.:;;:EXHAUSTED 71 Kitchens 100 cfm intermittent or 25 cfrn c'x Bathrooms-Toilet Mechanical exhaust capacity of- Rooms intermittent or 20 cfm continuous For SI: I cubic foot per minute=0.0004719 m3/s.ti S M, + 1 4 Z:if /)C—ci r-r.- f-....;), IT-' ..--' 61'itr.. lam \1 J•!X.+ 1 I::itri i. v. Lr i s, n 77 2015INTERNATIONE > 100 ECM HEAT RECOVERY VENTILATOR w I ENGINEERING DATA LIFEBRERTH THERMALLY CONDUCTIVE,PATENTED DEFROST i ALUMINUM CORE Recirculating damper defrost system. The counter-flow heat recovery core transfers heat between the two airstreams.It is easily removed for cleaning or service. CASE Twenty gauge prepainted galvanized steel for superior corrosion resistance.Insulated to MOTORS AND BLOWERS prevent exterior condensation.Drain connections 2-1/2 in.(12 mm)0D.Balancing ports High efficiency electronic commutate ECM motor,for maximum energy savings.Each are located on door. airstream has one centrifugal blower,with multiple fanspeed operations driven by one double shaft motor. ELECTRONICS The DXPLO2 control included with the unit can be wall mounted in a central location of FILTERS the home.3 wire 20 gauge(min.)100 ft length(max.). Washable air filters in exhaust and supply air streams. MOUNTING WARRANTY Four threaded inserts at corners of the cabinet designed to accept the"s"hooks and i , :-I 11 t = a r a ts; n - hanging straps supplied with the unit i! 11.-;t a,i, ^ n ra;++v. OPTIONAL ACCESSORIES: Weather Hood 1 Terminator Wireless 20/40/60 99-185 99-EAG4 a- EAG4 Fang Min Timer 99-186 9 99-TM4 99-DET02 99-EAG6 x 99-187 r_ lir-99-EAG8 99-TM5 la99-TM6 LIFEBREATH CONTROL OPTIONS TIMER OPTIONS 99-DET01-Lifebreath 20/40/60 Minute Timer FEATURES 99- XFL J? 99-8C0? q=; E3C 99-3C04 Initiates high speed Ventilation for 20,40 or 60 5 speed fan operation on each mode minutes.3 wire connection. 99-DET02 2 speed fan operation(Low/High) Wireless Lifebreath 20/40/60 Minute Timer Continuous low speed fan operation V Initiates high speed Ventilation for 20,40 or 60 minutes.Wirelessly connects to main control for Humidity control through adjustable Dehumidistat ease of installation.40'approximate range. Excusive to Lifebreath. Large digital LCD screen 99-RX02-Wireless Lifebreath Repeater LED status indicator lights Extends range of 99-DET02 Wireless Timers.Plugs into 120V power outlet.Wirelessly connects to Continuous Ventilation main control and 99-DET02.Install at halfway point between timer and main wall control if timer Continuous Recirculation is out of range. 20 0N/40 OFF e r11111:•It.K c 10 0N/50 OFF 20 ON/40 Recirculation I ;® i 20/40/60 min.High speed override button V 99-DXPLO2 99-DET02 Compatible with 99-DET02 Wireless Timer 3 wire connection L IFEBR R i1• Indoor Air Systems 100ECM(01-01-18) www.lifebreath.com 1u J 100 ECM kt :HEAT RECOVERY VENTILATOR PERFORMANCE(HVI CERTIFIED) LIFEBREFITH R. 0.1(=5) 0.2(SO) 3 3(75) 0.4(1L10) 0.5(125) 0.6(150) ELECTRICAL SPECIFICATIONSIN.W.G.(PA) I s _- );L,) < %)iI_,,) .."(L,$) I ,) VAC@60Hz 120 Net Supply Airflow 161(76) 143(68) 129(6i)'. 114(54) 97(46) 18(31) Watts/Low Speed 40 Gross Supply Airflow 165(18) 147(69) 131(621 117(55) 102(48) 81(38) Watts/High Speed 115 Gross Exhaust Airflow 229(108) 215(101) 210(99) 203(96) 184(87) 142(67) Amp Rating 1.15 Sensible Effectiveness(ASE) 32°F(0°C) 78% 180 WEIGHT: 71 LB5(32 KG) Sensible Efficiency(SRE) 32°F(0°C) 11% 140 SHIPPING WEIGHT: @ 64 CFM(30 Us) E 120 73 LBS(33 KG) u Sensible Efficiency(SRE) 32°F(0°C) 69% o loo @ 95 CFM(45 Us) i so Sensible Efficiency(SRE) - 13°F(-25°C) 64% a NOTE: 60 Front clearance of 25 in.(635 mm)is@68CFM(32 Us) 40 recommended for servicing unit AN ducts 20 111%4N. use 6 in.(152 mm)round collars.Balancing ISO dampers are located in all air streams. SW zloo 0.1 0.2 0.3 0.4 0.5 0.6 crvs;,;a C US HV' 9 eNeot b lM_gygatla CERTIFIED arslm Static Pressure(in w.g.) DIMENSIONS FRONT VIEW TOP VIEW I F 14 3/4 in.(315 mm) frost Recirculating I I ,II l I I L.Damped ; A : I i i i Removable Heat Blower Recovery Motor E Stale air to outside Core — ris,,,,,:. - ------- ----- Fresh air from outside v Stale air from inside Fresh air to inside0 6 in.(152 mm) J 33 5/8 in.(854 mm) o o v Round Collars I/ I Date:WARRANTY Tag: Contractor: i':-s ry a 2Iic >11111 91 Jo tha f- r UH lh 1 3 S , 3C I !3C?Tmoont 331(3 W9,r3' 4. Project* Qty:Supplier: Engineer: Quote#: All units conform to CSA and UL standards toll Control: Submitted By: LIFEBRERTH® II Indoor Air Systems Timer: Timer Qty: 100ECM(01-01-1.8)www.lifebreath.com REScheck Software Version .6.4 ci Compliance Certificate 0. N Project Foothills Builders Inc ct000 ui OCT 5 2018 oEnergyCode: 2015 IECC V V J 't Location: Glens Falls, New York ce J Construction Type: Single-family J -pn RI Project Type: New Construction U) CC cv Conditioned Floor Area: 1,812 ft2 C Ur Glazing Area 13% CClimateZone: 6 (7635 HDD) m N Permit Date: Permit Number: N 0 N 00lin ., = Construction Site: Owner/Agent: Designer/Contractor:QJohnClendonDriveVISIONEngineering, LLC fit) 0 CO a Lot#1 206 Glen Street CI) 0 II- Queensbury, NY 12804 Ste 56 N LL N (I) Glens Falls, NY 12801 518-792-9264 mplisnce:Passes using UA trade-off Compliance: 0.0%Better Than Code Maximum UA: 260 Your UA: 260 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Perimeter R-Value R-Value Ceiling 1: Raised or Energy Truss 952 49.0 0.0 0.020 19 Wall 1:Wood Frame, 16"o.c. 1,185 21.0 0.0 0.057 57 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 106 0.290 31 Door 1: Solid 20 0.240 5 Door 2: Solid 18 0.140 3 Door 3: Glass 40 0.290 12 Wall 2: Wood Frame, 16"o.c. 958 21.0 0.0 0.057 48 Window 2:Vinyl/Fiberglass Frame:Double Pane with Low-E 112 0.290 32 Floor 1:All-Wood Joist/Truss:Over Outside Air 10 38.0 0.0 0.026 0 Basement Wall 1: Solid Concrete or Masonry 1,027 0.0 15.0 0.045 45 Wall height: 7.8' Depth below grade: 7.2' Insulation depth: 7.8' Window 3:Vinyl/Fiberglass Frame:Double Pane with Low-E 16 0.290 5 Window 4:Vinyl/Fiberglass Frame:Double Pane 7 0.400 3 Project Title: Foothills Builders Inc Report date: 10/08/18 Data filename: C:\Users\Irobision\Desktop\1373 Rescheck.rck Page 1 of10 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to comply with the mandatory require n listed in the REScheck Inspection Checklist. Name-Title it tc)**Signature Da f Project Title: Foothills Builders Inc Report date: 10/08/18 Data filename: C:\Users\Irobision\Desktop\1373 Rescheck.rck Page 2 of10 REScheck Software Version 4.6.4 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions Req.ID 103.1, Construction drawings and Complies 103.2 documentation demonstrate Does Not PR1]1 energy code compliance for the building envelope.Thermal Not Observable envelope represented on Not Applicable construction documents. 103.1, Construction drawings and Complies 103.2, documentation demonstrate ElDoes Not 403.7 energy code compliance for PR3]1 lighting and mechanical systems Not Observable Systems serving multiple Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr Does Not PR232 on loads calculated per ACCA Cooling: Cooling:Manual J or other methods Not Observable approved by the code official. Btu/hr Btu/hr Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Inc Report date: 10/08/18 Data filename: C:\Users\Irobision\Desktop\1373 Rescheck.rck Page 3 of10 i Section Plans Verified Field Verified Foundation inspection Value Value Complies? Comments/Assumptions Req.iD 402.1.1 Conditioned basement wall R- R- Complies See the Envelope Assemblies FO4]1 insulation R-value.Where interior R_ R- Does Not table for values. insulation is used,verification Ale may need to occur during Not Observable Insulation Inspection. Not Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall Complies FO5]1 insulation installed per Does Not manufacturer's instructions. Not Observable Not Applicable 402.2.9 Conditioned basement wall ft ft Complies See the Envelope Assemblies FO6]1 insulation depth of burial or Does Not table for values. distance from top of wall.Not Observable Not Applicable 303.2,1. A protective covering is installed Complies F01112 to protect exposed exterior Does Not insulation and extends a minimum of 6 in. below grade. Not Observable Not Applicable 403,9 Snow-and ice-melting system Complies FO1212 controls installed. Does Not Ali Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Inc Report date: 10/08/18 Data filename: C:\Users\Irobision\Desktop\1373 Rescheck.rck Page 4 of10 i t Section Plans Verified Field VerifiedFramingIRough-In Inspection Value Value Complies? Comments/Assumptions '... Req.IO 402.1.1, Door U-factor.U- U- DComplies See the Envelope Assemblies 402.3.4 Does Not table for values. FR1]1 Not Observable Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- Complies See the Envelope Assemblies 402.3.1, average). Does Not table for values. 402.3.3, 402.3.6, Not Observable 402.5 Not Applicable FR2]1 303.1.3 U-factors of fenestration products DComplies FR4]1 are determined in accordance Does Not with the NFRC test procedure or taken from the default table. Not Observable Not Applicable 402.4.1.1 Air barrier and thermal barrier DComplies FR23]1 installed per manufacturer's Does Not instructions. Not Observable Not Applicable 402.4.3 Fenestration that is not site built MDComplies FR20]1 is listed and labeled as meeting Does Not AAMA/WDMA/CSA 101/I.5.2/A440 or has infiltration rates per NFRC Not Observable 400 that do not exceed code Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures Complies WR1612 sealed at housing/interior finish Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. Not Observable Not Applicable 403.2.1 Supply and return ducts in attics Complies FR12]1 insulated >= R-8 where duct is Does Not 3 inches in diameter and >= R-6 where< 3 inches. Supply and Not Observable return ducts in other portions of Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as Complies FR1513 ducts or plenums. Does Not Vi Not Observable Not Applicable 403.4 HVAC piping conveying fluids R- R- DComplies FR17j2 above 105°F or chilled fluids ODoes Not below 55°F are insulated to>_R- 3 Not Observable Not Applicable 403.4.1 Protection of insulation on HVAC DComplies FR24]1 piping. Does Not g Not Observable Not Applicable 403.5.3 Hot water pipes are insulated to R- R- Complies FR18]2 >_R-3. Does Not Not Observable Not Applicable 403.6 Automatic or gravity dampers are DComplies FR1912 installed on all outdoor air Does Not intakes and exhausts. Not Observable Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Inc Report date: 10/08/18 Data filename: C:\Users\Irobision\Desktop\1373 Rescheck.rck Page 5 of10 Section Plans Verified Field Verified Insulation Inspection Value Value Complies? Comments/Assumptions Req.JD 303.1 All installed insulation is labeled Complies 1N1312 or the installed R-values Does Not provided. Not Observable Not Applicable 402.1.1, Floor insulation R-value. R- R- Complies See the Envelope Assemblies 402.2.6 Wood Wood Does Not table for values. IN1]1 Steel Steel Not Observable Not Applicable 303.2, Floor insulation installed per Complies 402.2.7 manufacturer's instructions and Does Not IN2]1 in substantial contact with the has underside of the subfloor,or floor DNot Observable framing cavity insulation is in Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the . top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/ 2 of the ElWood Wood Does Not table for values. 402.2.6 wall insulation on the wall Mass Mass Not ObservableIN3]1 exterior,the exterior insulation requirement applies(FR10). Steel Steel Not Applicable 303.2 Wall insulation is installed per Complies IN4]1 manufacturer's instructions. Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Inc Report date: 10/08/18 Data filename: C:\Users\Irobision\Desktop\1373 Rescheck.rck Page 7 of10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions Req,ID 402.1.1, Ceiling insulation R-value. R- R- Complies See the Envelope Assemblies 402.2.1, Wood Wood Does Not table for values. 402.2.2, Steel Steel Not Observable 402.2.E[ FI1]1 DNot Applicable 303.1.1.1, Ceiling insulation installed per Complies 303.2 manufacturer's instructions. Does Not F12]1 Blown insulation marked every 300 ft2. Not Observable Not Applicable 402.2.3 Vented attics with air permeable Complies f F122]2 insulation include baffle adjacent Does Not to soffit and eave vents that extends over insulation. Not Observable Not Applicable 402.2.4 Attic access hatch and door R- R- Complies F13]1 insulation R-value of the Does Not adjacent assembly.Not Observable Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = Complies F117]1 ach in Climate Zones 1-2, and Does Not 3 ach in Climate Zones 3-8. Not Observable Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 Complies F14]1 cfm/100 ft2 across the system or ft2 ft2 Does Not 3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in Not Observable tests,verification may need to Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 Complies F127]1 determine air leakage with ft2 ft2 Does Not either: Rough-in test:Total leakage measured with a Not Observable pressure differential of 0.1 inch Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated Complies F124]1 by manufacturer at<=2%of DDoes Not design air flow. Not Observable Not Applicable 403.1.I Programmable thermostats Complies Fl9]2 installed for control of primary Does Not heating and cooling systems and initially set by manufacturer to Not Observable code specifications. Not Applicable 403.1.2 Heat pump thermostat installed Complies F110P on heat pumps. Does Not Not Observable Not Applicable 403.5.1 Circulating service hot water Complies f F11112 systems have automatic or Does Not accessible manual controls. ONot Observable Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) j Project Title: Foothills Builders Inc Report date: 10/08/18 Data filename: C:\Users\Irobision\Desktop\1373 Rescheck.rck Page 8 of10 t Section Plans Verified Field VerifiedFinalInspectionProvisions Value Value Complies? Comments/Assumptions tic Req.ID, 403.6.1 All mechanical ventilation system Complies F125]2 fans not part of tested and listed Does Not HVAC equipment meet efficacy and air flow limits. Not Observable Not Applicable 403.2 Hot water boilers supplying heat Complies F126]2 through one-or two-pipe heating Does Not systems have outdoor setback control to lower boiler water Not Observable temperature based on outdoor Not Applicable temperature. 403.5.1.1 Heated water circulation systems Complies F12812 have a circulation pump.The Does Not system return pipe is a dedicated return pipe or a cold water supply Not Observable pipe. Gravity and thermos- Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems Complies FI29]2 comply with IEEE 515.1 or UL Does Not 515.Controls automatically adjust the energy input to the Not Observable heat tracing to maintain the ElNot Applicable desired water temperature in the piping._ 403.5.2 Water distribution systems that Complies FI30]2 have recirculation pumps that Does Not pump water from a heated water supply pipe back to the heated Not Observable water source through a cold Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units DComplies 931]2 tested in accordance with CSA Does Not B55.1. Potable water-side pressure loss of drain water heat Not Observable recovery units < 3 psi for Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent Complies FI6]1 fixtures or 75%of permanent Does Not fixtures have high efficacy lamps. Does not apply to low-voltage Not Observable lighting.Not Applicable 404.1.1 Fuel gas lighting systems have Complies F123]3 no continuous pilot light. Does Not tt< Not Observable Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Inc Report date: 10/08/18 Data filename: C:\Users\lrobision\Desktop\1373 Rescheck.rck Page 9 of10 Section Plans Verified Field Verified Final inspection Provisions Complies? Comments/Assumptions Value Value ReqsID 401,3 Compliance certificate posted. ElComplies IF1712 DDoes Not O Not Observable O Not Applicable 303.3 Manufacturer manuals for OComplies V11813 mechanical and water heating ODoes Not systems have been provided.Not Observable ElNot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Foothills Builders Inc Report date: 10/08/18 Data filename: C:\Users\Irobision\Desktop\1373 Rescheck.rck Page 10 of10 Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 15.00 Floor 38.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door 0.29 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments Manual S Compliance Report Job: 1373 Date: Oct 25,2018 Entire House By: FOOTHILL BUILDERS Plan: 1373 QUEENSBURY,NY 12804 Project Information For: FOOTHILL BUILDER S E , QUEENSBURY, NY 12804 Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 23955 Btuh Entering coil DB: 75.3°F Outdoor design WB: 71.0°F Latent gain: 5080 Btuh Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 29035 Btuh Indoor RH: 50% Estimated airflow: 1146 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: TCHD36S41S3+FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1 Actual airflow: 1100 cfm Sensible capacity:0 Btuh 0% of load Latent capacity: 0 Btuh 0% of load Total capacity: 0 Btuh 0% of load SHR: 0% Heating Equipment Design Conditions Outdoor design DB: -4.0°F Heat loss: 93676 Btuh Entering coil DB: 65.5°F Indoor design DB: 68.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TM9X100C16MP11 Actual airflow: 1100 cfm Output capacity: 95000 Btuh 101% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. 2018-Oct-25 14:14:43 wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 AaCK ....langeworthy\Documents\York\JOHN CLENDON DR.rup Calc=MJ7 Front Door faces: N e Residential Plans Examiner Review Form Form RPER1 ACCk® for HVAC System Design (Loads, Equipment, Ducts) 15 Mar09 Pi Conclificriv ContaitiscOmerica QUEENSBURY NY Header Information Contractor: FOOTHILL BUILDERS REQUIRED ATTACHMENTS ATTACHED Manual J1 Form(and supporting worksheets): Yes No Mechanical license: or MJ1AE Form*(and supporting worksheets): Yes No OEM performance data(heating,cooling,blower): Yes No Building plan#: 1373 Manual D Friction Rate Worksheet: Yes 0 No Duct distribution sketch: Yes No El Home address(Street or Lot#,Block,Subdivision): , Entire House HVAC LOAD CALCULATION (IRC M1401.3) Design Conditions Building Construction Information Winter Design Conditions Building Outdoor temperature:4 °F Orientation: Front Door faces North Indoor temperature: 68 °F North,East,West,south,Northeast,Northwest,Southeast,Southwest Total heat loss: 93676 Btuh Number of bedrooms: 3 Conditioned floor area: 4613 ft2 Summer Design Conditions Number of occupants: 0 Outdoor temperature: 85 °F Indoor temperature: 75 °F Windows Roof Grains difference: 27 gr/Ib I't7 0% RH Eave overhang depth: 0 ft Sensible heat gain: 26617 Btuh Internal shade:noneEave Latent heat gain: 5644 Btuh Blinds,drapes,etc. Depth Window Total heat gain: 32261 Btuh Number of skylights: 0 HVAC EQUIPMENT SELECTION (IRC M1401.3) Heating Equipment Data Cooling Equipment Data Blower Data Equipment type: Gas furnace Equipment type:Split AC Heating cfm: 1100 umace,Heat pump,Boiler,etc. Air Conditioner,Heat pump,etc. Cooling cfm: 1100 Model: York Model: York Static pressure:0 in H2O TM9X100C16MP11 TCHD36S41 S3 Fan's rated extemal static pressure for design airflow Heating output capacity: 9500 Btuh Total cooling capacity:0 Btuh Heat pumps-capacity at winter design outdoorconditions Sensible cooling capacity: 0 Btuh Aux.heating output capacity: 0 Btuh Latent cooling capacity: 0 Btuh HVAC DUCT DISTRIBUTION SYSTEM DESIGN (IRC M1601 .1) Design airflow: 1100 cfm Longest supply duct: 0 ft Duct Materials Used Equipment design ESP: 0 in H2O Longest return duct: 0 ft Trunk duct: Total device pressure losses: 0 in H2O Total effective length(TEL): 0 ft Available static pressure(ASP): 0 in H2O Friction rate: 0 in/100ft Branch duct: Sheet metal Friction Rate=ASP+(TEL x 10 ) I declare the load calculation equipment equipment selection and duct design were rigorously performed based on the building plan listed above. I understand the claims made on these forms will be subject to review and verification. Contractor's printed name: Contractor's signature: Date: Reserved for County.Town Municipality orAuthority having jurisdiction use. Home qualifies for MJ1AE Form based on Abridged Edition Checklist wrightsoft® Right-Suite®Universal 2017 17.0.16 RSU25116 t f Project Summary Job: 1373Date: Oct 25,2018 Entire House By: FOOTHILL BUILDERS Plan: 1373 QUEENSBURY,NY 12804 Pro.ect Information For: FOOTHILL BUILDERS QUEENSBURY, NY 12804 Notes: Desi• n Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db 4 °F Outside db 85 °F Inside db 68 °F Inside db 75 °F Design TD 72 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 88125 Btuh Structure 22838 Btuh Ducts 5550 Btuh Ducts 1117 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none) none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 93676 Btuh Use manufacturer's data n Rate/swing multiplier 0.90 Infiltration Equipment sensible load 21560 Btuh Method Simplified Latent Cooling Equipment Load SizingConstructionqualityAverage Fireplaces 0 Structure 5080 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling none) Area(ft2) 4613 4613 Equipment latent load 5080 Btuh Volume(ft3) 41517 41517 Air changes/hour 0.70 0.40 Equipment total load 26640 Btuh Equiv.AVF(cfm) 484 277 Req. total capacity at 0.70 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK Trade HORIZONTAL DISCHARGE Model TM9X100C16MP11 Cond TCHD36S41S3 AHRI ref 2008692 Coil FC37A3XC1+TM8X060Al2MP11+S1-1TVM4G1 AHRI ref 3743636 Efficiency 95.5 AFUE Efficiency 12.0 EER, 14.1 SEER Heating input 100000 Btuh Sensible cooling 23100 Btuh Heating output 95000 Btuh Latent cooling 9900 Btuh Temperature rise 79 °F Total cooling 33000 Btuh Actual air flow 1100 cfm Actual air flow 1100 cfm Air flow factor 0.012 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. WI'1 htsoft® 2018-Oct-2514:14:43 4-- 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1Acck ....langeworthy\Documents\York\JOHN CLENDON DR.rup Calc=MJ7 Front Door faces: N t Rig ht-J®Worksheet Job: 1373 Entire House Date: Oct 25,2018 FOOTHILL BUILDERS Plan: 1373 QUEENSBURY,NY 12804 MANUAL J:7th Ed. 1 Name of room Entire House Room2 Room3 Room4 2 Length of exposed wall 638.0 ft 134.0 ft 118.0 ft 26.0 ft 3 Room dimensions 1.0 x 975.0 ft 32.0 x 27.0 ft 1.0 x 159.0 ft 4 Ceilings Condit.Option 9.0 ft d 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 5742 **** **** 1206 **** **** 1062 **** ****234 **** **** Exposed b 0 0 111111 **** ****III!II **** ****IIIIII **** ****II III I **** **** walls and c 0 0 I I I I I I **** ****urn! **** ****min **** ****IIIIII **** **** partitions d 0 0 IIIIII **** ****III III **** ****IIIIII **** ****IIIIII **** **** e 0 0 IIIIII **** ****I I I I I I **** ****IIIIII **** ****I III II **** **** f 0 0 IIIIII **** ****IIIli! **** ****IIIIII **** ****I II,II **** **** 6 Windows and a 3A0 39.7 ** 295 11703 **** 50 1984 **** 0 0 **** 30 1190 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 110 **** 2090 15 ****285 0 **** 0 30 ****570 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 95 **** 6460 35 **** 2380 0 **** 0 0 **** 0 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 90 **** 3060 0 **** 0 0 **** 0 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0, 33.1 6.3 84 2782 526 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 5363 28960 5470 1156 6242 1179 1062 5735 1083 204 1102 208 exposed b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 walls and c 0 0 111111 0 0 111111 0 0 IIIIII 0 0 111111 0 0 partitions d 0 0 111111 0 0 111111 0 0 111111 0 0 null 0 0 e 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 111111 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 10 Ceilings a 16G0 2.4 1.1 1950 4633 2188 0 0 0 864 2053 969 159 378 178 b 0 0 111111 0 0 111111 0 0 mill 0 0 111111 0 0 C 0 0 111111 0 0 111111 0 0 111111 0 0 IIIIII 0 0 d 0 0 111111 0 0 IIIIII 0 0 111111 0 0 111111 0 0 e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 11 Floors a 1910 1.7 0 975 1685 0 975 1685 0 0 0 0 0 0 0 Note:room b 0 0 nnn 0 0 111111 0 0 111111 0 0 111111 0 0 perimeter c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 is displ.d 0 0 IIIIII 0 0 111111 0 0 111111 0 0 111111 0 0 for slab e 0 0 111111 0 0 111111 0 0 111111 0 0 'III 11 0 0 floors) f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 12 Infiltration a 101 8.0 379 38362 3045 50 5061 402 0 0 0 30 3037 241 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 88125 **** **** 14972 **** **** 7788 **** **** 5706 **** Less external heating 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 5550 **** 6% 943 **** 6% 490 **** 6% 359 **** 15 Total loss=13+14 93676 **** **** 15915 **** **** 8278 **** **** 6065 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. c@D 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 22838 **** **** 4246 **** **** 2053 **** ****1197 Less external cooling 0 **** **** 0 **** **** 0 **** **** 0 Less transfer 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% ****1117 5% ****208 5% ****100 5% **** 59 19 Total RSH gain=(17+18)*PLF 1.00 **** 23955 1.00 **** 4453 1.00 **** 2153 1.00 **** 1256 20 Air required(cfm) 1100 1100 187 204 97 99 71 58 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. t wr- htsOft® 2018-Oct-2514:14:43 AA= 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 1 langeworthy\Documents\York\JOHN CLENDON DR.rup Calc=MJ7 Front Door faces: N Right-J®Worksheet Job: 1373 Entire House Date: Oct 25,2018 By: FOOTHILL BUILDERS Plan: 1373 QUEENSBURY,NY 12804 MANUAL J:7th Ed. 1 Name of room Room5 Room6 Room7 Room8 2 Length of exposed wall 10.0 ft 17.0 ft 18.0 ft 11.0 ft 3 Room dimensions 10.0 x 9.0 ft 8.0 x 9.0 ft 1.0 x 70.0 ft 1.0 x 120.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 90 **** ****153 **** ****162 **** **** 99 **** **** Exposed b 0 0 111111 **** ****111111 **** ****IIIIII **** ****IIIIII **** **** walls and c 0 0 111111 **** ****IIIIII **** ****MI **** ****IIIIII **** **** partitions d 0 0 111111 **** ****IIIIII **** ****I I I I I I **** ****IIIIII **** **** e 0 0 111111 **** ****II1ill **** ****IIIIII **** ****IIIIII **** **** f 0 0 IIIIII **** ****IIIIII **** ****IIIIII **** ****111111 **** **** 6 Windows and a 3A0 39.7 ** 10 397 **** 10 397 **** 15 595 **** 30 1190 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** d 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 10 ****190 10 ****190 0 **** 0 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 0 **** 0 0 **** 0 15 ****510 30 **** 1020 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10DO 33.1 6.3 0 0 0 0 0 0 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 80 432 82 143 772 146 147 794 150 69 373 70 exposed b 0 0 111111 0 0 HIM 0 0 1111 I I 0 0 HUH 0 0 walls and c 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 partitions d 0 0 111111 0 0 IIIIII 0 0 IIIIII o 0 IIIIII 0 0 e 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 HMI 0 0 f 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 10 Ceilings a 16G0 2.4 1.1 90 214 101 72 171 81 70 166 79 120 285 135 b 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 c 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 e 0 0 111111 0 0 IIIIII 0 0 null 0 0 IIIIII 0 0 e 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 null 0 0 f 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 Note:room b 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 perimeter c 0 0 111111 0 0 IIIIII 0 0 111111 0 0 IIIIII 0 0 is displ.d 0 0 111111 0 0 nnn 0 0 nnn 0 0 111111 0 0 for slab e 0 0 111111 0 0 Inns 0 0 HMI 0 0 IIIIII 0 0 floors) f 0 0 1 1 1111 0 0 IIIIII 0 0 IIIIII 0 0 HIM 0 0 12 Infiltration a 101 8.0 10 1012 80 10 1012 80 15 1518 120 30 3037 241 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 2055 **** **** 2352 **** **** 3073 **** **** 4884 **** Less external heating 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 129 **** 6% 148 **** 6% 194 **** 6% 308 **** 15 Total loss=13+14 2184 **** **** 2500 **** **** 3267 **** **** 5192 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 453 **** ****497 **** ****859 **** **** 1466 Less external cooling 0 **** **** 0 **** **** 0 **** **** 0 Less transfer 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 22 5% **** 24 5% **** 42 5% **** 72 19 Total RSH gain=(17+18)*PLF 1.00 ****475 1.00 ****521 1.00 ****901 1.00 **** 1538 20 Air required(cfm) 26 22 29 24 38 41 61 71 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wri htsoft® 2018-Oct-25 14:14:43 6A A Right-Suite®Universal 2017 17.0.16 RSU25116 Page 2 langeworthy\Documents\York\JOHN CLENDON DR.rup Calc=MJ7 Front Door faces: N Rig ht-J®Worksheet Job: 1373 Entire House Date: Oct 25,2018 y FOOTHILL BUILDERS PBla:n: 1373 QUEENSBURY,NY 12804 MANUAL J:7th Ed. 1 Name of room Room9 Room10 Room12 Room13 2 Length of exposed wall 28.0 ft 8.0 ft 134.0 ft 75.0 ft 3 Room dimensions 1.0 x 190.0 ft 1.0 x 163.0 ft 1.0 x 975.0 ft 1.0 x 548.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 252 **** **** 72 **** **** 1206 **** ****675 **** **** Exposed b 0 0 I I I I I I **** ****I l l t 11 **** ****11 1111 **** ****will **** **** walls and c 0 0 IIIIII **** ****IIIIII **** ****111111 **** ****111111 **** **** partitions d 0 0 IIIIII **** ****IIIIII **** ****IIIIII **** ****IIIIII **** **** e 0 0 IIIIII **** ****IIIIII **** ****111111 **** ****IIIIII **** **** f 0 0 IIIIII **** ****IIIIII **** ****IIIIII **** ****IIIIII **** **** 6 Windows and a 3A0 39.7 **30 1190 **** 0 0 **** 0 0 **** 90 3570 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 45 ****855 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 15 **** 1020 0 **** 0 0 **** 0 45 **** 3060 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 15 ****510 0 **** 0 0 **** 0 0 **** 0 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 0 0 0 0 0 0 0 0 0 42 1391 263 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3 5.4 1.0 222 1199 226 72 389 73 1206 6512 1230 543 2932 554 exposed b 0 0 IIIIII 0 0 IIIIII 0 0 I11111 0 0 HIM 0 0 walls and c 0 0 IIIIII 0 0 IIIIII 0 0 111111 0 0 IIIIII 0 0 partitions d 0 0 11111 0 0 IIIIII 0 0 Inns 0 0 111111 0 0 e 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 f 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 111111 0 0 10 Ceilings a 16G0 2.4 1.1 190 451 213 163 387 183 111 264 125 96 228 108 b 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 C 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 d 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 1nn1 0 0 e 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 f 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 111111 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 Note:room b 0 0 111111 0 0 111111 0 0 IIIIII 0 0 111111 0 0 perimeter c 0 0 111111 0 0 IIIIII 0 0 IIIIII 0 0 IIIIII 0 0 is displ.d 0 0 111 111 0 0 IIIIII 0 0 111111 0 0 IIIIII 0 0 for slab e 0 0 111111 0 0 HMI 0 0 Inlii 0 0 11111 0 0 floors) f 0 0 111111 0 0 IIn11 0 0 IIIIII 0 0 11111 0 0 12 Infiltration a 101 8.0 30 3037 241 0 0 0 0 0 0 132 13361 1060 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 5877 **** ****776 **** **** 6776 **** **** 21483 **** Less external heating 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 370 **** 6% 49 **** 6% 427 **** 6% 1353 **** 15 Total loss=13+14 6247 **** ****825 **** **** 7203 **** **** 22836 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. ©1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 2211 **** ****256 **** **** 1355 **** **** 5900 Less external cooling 0 **** **** 0 **** **** 0 **** **** 0 Less transfer 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% ****108 5% **** 13 5% **** 66 5% ****289 19 Total RSH gain=(17+18)*PLF 1.00 **** 2319 1.00 ****269 1.00 **** 1421 1.00 **** 6188 20 Air required(cfm) 73 106 10 12 85 65 268 284 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. t wri F tsoft® 2018-Oct-25 14:14:43 A A Right-Suite®Universal 2017 17.0.16 RSU25116 Page 3 langeworthy\Documents\York\JOHN CLENDON DR.rup Calc=MJ7 Front Door faces: N Rig ht-J®Worksheet Job: 1373 Entire House Date: Oct 25,2018 y FOOTHILL BUILDERS PBla:n: 1373 QUEENSBURY,NY 12804 MANUAL J:7th Ed. 1 Name of room Room 14 Room 15 Room 16 Room 17 2 Length of exposed wall 22.0 ft 17.0 ft 2.0 ft 6.0 ft 3 Room dimensions 11.0 x 11.0 ft 1.0 x 182.0 ft 2.0 x 6.0 ft 6.0 x 6.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) Area Load(Btuh) EXPOSURE NO. Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg (ft2) Htg Clg 5 Gross a 12E3 5.4 1.0 198 **** ****153 **** **** 18 **** **** 54 **** **** Exposed b 0 0 111111 **** ****IIIIII **** ****IIIIII **** ****HIM **** **** walls and c 0 0 111111 **** ****III!! **** ****IIIIII **** ****mill **** **** partitions d 0 0 111111 **** ****II" **** ****111111 **** ****will **** **** e 0 0 111111 **** ****mill **** ****IIIIII **** ****will **** **** f 0 0 111111 **** ****mill **** ****mu, **** ****will **** **** 6 Windows and a 3A0 39.7 ** 15 595 **** 0 0 **** 0 0 **** 15 595 **** glass doors b 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** Heating c 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** e 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** f 0 ** 0 0 **** 0 0 **** 0 0 **** 0 0 **** 7 Windows and North 19.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 glass doors NE/NW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Cooling E/W 68.0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 SE/SW 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 South 34.0 15 ****510 0 **** 0 0 **** 0 15 ****510 Horz 0 0 **** 0 0 **** 0 0 **** 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 0 0 0 42 1391 263 0 0 0 0 0 0 b 0 0 0 0 0 0 0 0 0 0 0 0 0 0 c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 9 Net a 12E3. 5.4 1.0 183 988 187 111 599 113 18 97 18 39 211 40 exposed b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 walls and c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 partitions d 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 f 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 10 Ceilings a 16G0 2.4 1.1 0 0 0 9 21 10 0 0 0 0 0 0 b 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 d 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 e 0 0 11 11 11 0 0 1 11 11 1 0 0 111111 0 0 111111 0 0 f 0 0 111111 0 0 will 0 0 111111 0 0 111111 0 0 11 Floors a 1910 1.7 0 0 0 0 0 0 0 0 0 0 0 0 0 Note:room b 0 0 111111 0 0 will 0 0 111111 0 0 111111 0 0 perimeter c 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 is displ.d 0 0 111111 0 0 mill 0 0 111111 0 0 111111 0 0 for slab e 0 0 111111 0 0 111111 0 0 111111 0 0 111111 0 0 floors) f 0 0 111111 0 0 IIIIII 0 0 111111 0 0 111111 0 0 12 Infiltration a 101 8.0 15 1518 120 42 4251 337 0 0 0 15 1518 120 Ventilation 0 0 0 0 0 0 0 0 13 Subtotal loss=6+8..+11+12 3102 **** **** 6263 **** **** 97 **** **** 2324 **** Less external heating 0 **** **** 0 **** **** 0 **** **** 0 **** Less transfer 0 **** **** 0 **** **** 0 **** **** 0 **** Heating redistribution 0 **** **** 0 **** **** 0 **** **** 0 **** 14 Duct loss 6% 195 **** 6% 394 **** 6% 6 **** 6% 146 **** 15 Total loss=13+14 3297 **** **** 6657 **** ****103 **** **** 2470 **** 16 Int.gains: People @ 300 0 **** 0 0 **** 0 0 **** 0 0 **** 0 Appl. @ 1200 0 **** 0 0 **** 0 0 **** 0 0 **** 0 17 Subtot RSH gain=7+8..+12+16 817 **** ****723 **** **** 18 **** ****670 Less external cooling 0 **** **** 0 **** **** 0 **** **** 0 Less transfer 0 **** **** 0 **** **** 0 **** **** 0 Cooling redistribution 0 **** **** 0 **** **** 0 **** **** 0 18 Duct gain 5% **** 40 5% **** 35 5% **** 1 5% **** 33 19 Total RSH gain=(17+18)*PLF 1.00 ****857 1.00 ****759 1.00 **** 19 1.00 ****703 20 Air required(cfm) 39 39 78 35 1 1 29 32 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 4C P. wrightsoft® 2018-Oct-25 14:14:43 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 4 langeworthy\Documents\York\JOHN CLENDON DR.rup Calc=MJ7 Front Door faces: N v Right-J®Worksheet Job: 1373 Entire House Date: Oct 25,2018 By: FOOTHILL BUILDERS Plan: 1373 QUEENSBURY,NY 12804 MANUAL J:7th Ed. 1 Name of room Room18 2 Length of exposed wall 12.0 ft 3 Room dimensions 6.0 x 6.0 ft 4 Ceilings Condit.Option 9.0 ft heat/cool TYPE OF CST HTM Area Load(Btuh) Area Area Area EXPOSURE NO. Htg Clg (ft2) Htg Clg Htg Clg Htg Clg Htg Clg 5 Gross a 12E3 5.4 1.0 108 **** **** Exposed b; 0 0 11111 I **** **** walls and c 0 0 win **** **** partitions d 0 0 Him **** **** e 0 0 win **** **** f 0 0 111111 **** **** 6 Windows and a 3A0 39.7 ** 0 0 **** glass doors b 0 ** 0 0 **** Heating c 0 ** 0 0 **** d 0 ** 0 0 **** e 0 ** 0 0 **** f 0 ** 0 0 **** 7 Windows and North 19.0 0 **** 0 glass doors NE/NW 0 0 **** 0 Cooling E/W 68.0 0 **** 0 SE/SW 0 0 **** 0 South 34.0 0 **** 0 Horz 0 0 **** 0 8 Other doors a 10D0 33.1 6.3 0 0 0 b 0 0 0 0 0 c 0 0 0 0 0 9 Net a 12E3 5.4 1.0 108 583 110 exposed b 0 0 111111 0 0 walls and c 0 0 win 0 0 partitions d 0 0 i l l i i i 0 0 e 0 0 will 0 0 f 0 0 111111 0 0 10 Ceilings a 16G0 2.4 1.1 6 14 7 b 0 0 111111 0 0 c 0 0 111111 0 0 d 0 0 111111 0 0 e 0 0 Iliill 0 0 f 0 0 will 0 0 11 Floors a 1910 1.7 0 0 0 0 Note:room b 0 0 will 0 0 perimeter c 0 0 illiii 0 0 is displ.d 0 0 IIIIII 0 0 for slab e 0 0 111 i 11 0 0 floors) f 0 0 111 i 11 0 0 12 Infiltration a 101 8.0 0 0 0 Ventilation 0 0 13 Subtotal loss=6+8..+11+12 597 **** **** Less external heating 0 **** **** Less transfer 0 **** **** Heating redistribution 0 **** **** 14 Duct loss 6%38 **** 15 Total loss=13+14 635 **** **** 16 Int.gains: People @ 300 0 **** 0 Appl. @ 1200 0 **** 0 17 Subtot RSH gain=7+8..+12+16 117 **** **** Less external cooling 0 **** **** Less transfer 0 **** **** Coding redistribution 0 **** **** 18 Duct gain 5% **** 6 19 Total RSH gain=(17+18)*PLF 1.00 ****123 20 Air required(cfm) 7 6 Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. wri htsoft® 2018-Oct-2514:14:43 9 Right-Suite®Universal 2017 17.0.16 RSU25116 Page 5 AC ....langeworthy\Documents\York\JOHN CLENDON DR.rup Calc=MJ7 Front Door faces: N I i II I I II III I AP'M REFERENCE: ,MAGNET IC PER REF.. 9A .ERMAP LEUCI 0J HN CLENDO N ROAD SUBDIVISION" BY: VAN TE EDUSEN & S V S LAND SURVEYORS AND ACEr"ENGINNERINN G P.C. I DATE: MARCH 15 1:20 fi LAST REVISED: JUNE 12 2O17 FILED: JULY 1 9-2017 PLAT D-1 3 INSTRUMENT O. 2 17- 0N03000 63 LANDS 0F SCOTT OR RSGE LANDS. OF JOY CE SHOVAH a. N 04001 '40" Pi 2.10 r o 40:0 5 dTN0 t Gd 1-r 7 CV T OF wk co 3:jo,zt T p ter 5hut0 Of vVae L 1LOT V,...1 q80255.9ery}Feete./,yam Acres -. m Cable TV Pedestal coo. Elect Box z 78 0 0 W r LOT 2 so RRVEYAL aa. ,:,-Y :...: it •..Y •. : gy I b tAke 2- Date, October .% 20118 rD u a UNAUTHORIZED ALTERATION OR ADDITION TO A.SURVEY I ScaE e _1 40 Map c XX. Sur`c llldd forMAPBEARINGALICENSED.LAND SURVEYORS SEAL IS A d Y C y VIOLATION OF SECTION 7209, rSUB-DIVISION 2 OF THE VG+ NEW QRKY STATE EDUCATION LAW.i ICE F IONLY.COPIES FROM THE ORIGINAL 0 THIS SURVEY Stev MARKEDE WITH AN ORIGINAL OF THE LAND SURVEYORS CONSIDERED, TO DE VALID TRUE COPIES."SEAL SHALL BES.'E 1 'CERTIFICATIONS INDICATED HEREON SIGNIFY THAT ACCORDANCE WITH,THETHISSURVEYWASPREPAREDINA 11 . 1 Foothills Builder S EYJSTING CODE OF PRACTICE FOR LAND SURVEYORS ADOPTED ORK STATEBYTHENEWYATE ASSOCIATION OF PROFESSIONALLaIldS -urve o r s LAND SURVEYORS.SAID CERTI FICATIONS SHALL RUN ONLYyESURVEYISPREPAREANDTOTHEPERSONFORWHOMTHE DI SHEET 1 OF 1 S BEHALF TO THE TITLE COMPANY GOVERNMENTALONN i oN usT€o ti€ a 7 r rINTiTUTIHEREON,ANDAGENCYANDLENDINGSGEN c. Y o Iaa 1 Cunt N l .CJZ111 C3 LtC,L115 J1.11 l 1Y71 1,8 0 LENDING I t CA 7 1}lV169` H r'l d Il Cl Road Ll e 11 li l Newi Y o fo THE ASSIGNEES>E LEND INSTITUTION.' 1 2 8 BUILDING FO{2THILLS r- r DWG, NO. 09094 1N0. DATE DESCRIPTIONa181918-`7 New 'Yol h. Lie. No. t(l l R3 I