Loading...
SOLAR-0679-2018TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SOLAR-0679-2018 Date Issued: Wednesday, February 13, 2019 This is to certify that work requested to be done as shown by Permit Number has been completed. SOLAR-0679-2018 Tax Map Number: Location: Owner: 308.7-1-69 58 RICHMOND HILL DR Christian Raeth Applicant:Apex Solar Power This structure may be occupied as a: Solar Panel Installation (roof) By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board or Zoning Board of Appeals. Director of Building & Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: SOLAR-0679-2018 Tax Map No: 308.7-1-69 Permission is hereby granted to: Christian Raeth For property located at: 58 RICHMOND HILL DR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Christian Raeth Solar Panel-Residential $40,200.00 Owner Address: 58 Richmond Hill DR Total Value $40,200.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Apex Solar Power 64 MAIN ST Queensbury,NY 12804 Plans&Specifications Solar Panel Installation $ 75.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Tuesday,November 5,2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration ..te Dated at the Town Quee ury; 4M ..; 'ovember 5,2018 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement r ytj'1' -p 3or. ;ow_ Office Use Only Permit#: 50L � Fee:$ 7S 742 Bay Road,Queensbury,NY 12804 Invoice#: Ogg P:518-761-8256 www.queensbury.net SOLAR PANEL PERMIT APPLICATION t 7 � 3 • Property Owner(s): a Name(s): Cl1.ra c icon k�►�,'�h _,_u__ Mailing Address, C/S/Z: Rid,rnarlJ l4ill Drives Queer bust/ Iv9 t2<ea4 Cell Phone:_( ) Land Line:_( SZR ) O2' Email: Project Address: SI RIC..hmori 14itl Dris Section Block Lot: soicii--1—(' Existing Use: ►'. Single Family ❑ 2-4 Family ❑ Commercial ❑ Other: • Solar Contractor: Business Name: erreArse LIDRA Qgex. Sonar eovi& Contact Name: SAL Rinkeiria Mailing Address, C/S/Z: (jLt ralA Si--ree. -,au burl 12,1/34 Cell Phone:_( ) Land Line:_( SAW ) 3og- Email: • Electrical Contractor: Business Name: Qfey. Solar Po'er Contact Name: are Mailing Address, C/S/Z: Cekme Cell Phone:_( ) Land Line:_( ) Email: Contact Person for Building& Code Compliance: (MI }-hMeirl[. (t ex SJic r-foupr) Cell Phone: ( ) Land Line: ( tS ) ;oct—Z' c, Email: Solar Panel Application Revised December 2017 Estimated cost of construction: $ u1© 2.44v.., Total System Capacity Rating (sum of all panels): Solar PV System: 12- kW DC Select System Configuration: 4t9lease See )AcikA4e<I Se+eta4S- ❑ Supply side connection with micro inverters ❑ Supply side connection with DC optimizers D Supply side connection with string inverter ❑ Load side connection with DC optimizers ❑ Load side connection with micro inverters ❑ Load side connection with string inverter Please sign below to affirm that all answers are correct and that you have met all the conditions and requirements to submit a unified solar permit. *Please. See &.4t4•eel rvAt riM Homeowner's Signature Date Goluttrip4j1 e_tclr1a eX Solar fa A 1vI3t)di Solar Co. Representative Signature Date Solar Panel Application Revised December 2017 DocuSign Envelope ID:BF121 F48-81 F5-412F-80F0-058664D230C0 • • • • • �•:• he• • •• •• • • ••.•O.• • • • • • • apex 5o1ar AUTHORIZATION FORM "TO ACT AS AGENT FOR" Christian Raeth owner of the premises located at: 58 Richmond Hill Drive Town of Queensbury Tax Parcel# 308.7-1-69 hereby designate: Apex Solar Power as my AGENT regarding my Permit Application for: PV Installation DocuSigned 10/22/2018 C SIGS 4*-j 844ED6EB1 E5C42E... Date Signature INSPECTION WORKSHEET (BINS-000864-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:SOLAR-0679-2018 Case Module:Permit Inspection Date:Wed Feb 13, 2019 Inspection Status:Passed Inspector:Charles Dyer Inspection Type:Solar Panel System Job Address:Parcel Number:58 RICHMOND HILL DR Queensbury, NY 12804 308.7-1-69 Contact Type Company Name Name Granted Permission Raeth, Christian Contractor Apex Solar Power Primary Owner Raeth, Christian Electrical Contractor Apex Solar Power Checklist Item Passed Comments 18" From Ridge YES Final Electrical YES 3' Access from Ground (Residential)YES Wiring not touching roof under panels YES Rapid shutdown present & labeled YES 18" From Valleys YES 3' Access on Roof YES Feb 13, 2019 Page (1) INSPECTION WORKSHEET (BINS-000864-2019) Checklist Item Passed Comments Building Inspector Notes NO Okay To Issue CC YES 2/13/19 solar panel system approved Placement of Panels YES Panels on south side of second story roof All wiring from roof in conduit YES Labeling of all panels & conduits YES Feb 13, 2019 Page (2) Dyer, Charles (Inspector) 308.7-1-69 SOLAR-0679-2018 Raeth, Christian 58 Richmond Hill Rd PHOTOVOLTAIC SYSTEM Solar Panel Installation I EQUIPMENT: PV MODULES: (40)TRINA TSM300DD05.05(1I) SYSTEM SIZE: INVERTER(S): (1)SE11400H-US DC/AC kW STC: 12kW\11.4kW SCOPE OF WORK: INSTALLATION OF A SAFE AND CODE-COMPLIANT 71 GRID-TIED SOLAR PV SYSTEM. r-- m m o O z 0 *-Q 'glutI C ^YES NO s"Z tr` POST INSTALL SUNEYES REQUIRED? I I a �,i + APPUCABLE CODES: ..y 0_,_Arn 2015 IRC CODE -- s . -f a �Z 2015 NYS BUILDING CODE . • ;2. -� `- 2015 NYS RESIDENTIAL CODE c� yC 2015 NYS PLUMBING CODE c0 0)O�y Z,:1 2015 NYS MECHANICAL CODE O y u g —.t-< 2014 NATIONAL ELECTRICAL CODE p SHEET INDEX (3i-!v��Cpp y c_'D 4fic PV-01 COVER AND PLOT PLAN op,a 03 @ PV-02 SITE PLAN,STRINGS,BOM PV-03.01 MODULE LAYOUT 1 OF 2 --- PV-03.02 MODULE LAYOUT 2 OF 2 SITE PLAN PV-04 THREE-UNE DIAGRAM --- SCALE: N.T.S. REVISION NOTES: DRAWN DATE: PROJECT NAME: CLIENT: SCALE: 64 Main Street REV REV BY DATE DESCRIPTION BY: RAETH CHRISTIAN RAETH Queenabu y,NY 12804 LD 10/4/2018 ROOF MOUNT 58 RICHMOND HILL DR CHECK 12,000 WATTS QUEENSBURY,NY 12804 DRAWING salesropexsolarpower.com BY: DATE: 518-222-0288 NUMBER: (518}309.2786 DRAWING TITLE: COVER AND PLOT PLAN PV-01 DISCONNECT DISCONNECT INVERTER ism STRING 3 —--— PROPERTY LINE ®SUBPANEL UTILITY METER 14 MODULES CONDUIT RUN 8 CC DISCONNECT DRIvEwAy { INVERTER 1 ( I SOLAR MODULE 0AC DISCONNECT NEW MSP ATS i LI INPUT 3 ED AWN SERVICE PANEL JUNCTION BOX ID MONITORING ING UNIT w UTI.IT �METER PV METERCOMBINER BOX D ROOF OBSTRUCTION O CUSTOMER INITIALS: 0 STRING 2 12 MODULES INVERTER 1 INPUT 2 0 >0,' 0' ' STRING 1 14 MODULES INVERTER 1 INPUT 1 NOTES: SITE PLAN DETAIL 1. INVERTER AND DISCONNECT TO BE LOCATED IN THE BASEMENT NEAR THE MAIN SERVICE PANEL SCALE: N.T.S. N 2. DISCONNECT TO BE LOCATED EXTERNALLY 64 Main Street REVISION NOTES: ' DRAWN DATE: PROJECT NAME: 1 CLIENT: SCALE: Qaeensbuty,NY 12804 REV i REV BY 1 DATE DESCRIPTION BY. NTH CHRISTIAN RAETH I 5560 Road LD 10/4/2018 ROOF MOUNT 58 RICHMOND HILL DR Fact Syrxuse,NY 13057 CHECK 12,41pt}WATTS GIUEENSBURY,NY 12804 j DRAWING DATE: eak:Qapexrolarpower.com BY: 518-222-0288 NUMBER: tslis}3a9-278b 1 i DRAWING TITLE: SITE PLAN,BOM,NOTES PV-02 r ®S�pANEL R,t,�� �c�ONNEGt ��pU1T RUN ��aSG�EGT __ --- G ,cJAY a�GTtONBOX DK„"- ,gyp tOWN4 UNit S�MooU� !��' (fan MIN MAINSevW PANEL ©►C:o NERIta a ���MEtER Q R�pgSTRUGTION VENTIIA�TIpN ACCESS ��MEtER ACCESS (36„ MIN) EtINI� G ALS:�.� AC Gyg?ONCE .;OFN�WYU /t h it 0fi�. ~#4?�55'�.1 SI.° II WO 111 1111i1.611°S I I Irl 6�� MINI AY (3 1L fil S PAS DET SI III IS p` 0AGES LPNN T.S I 1101111,4 F itk iREP SGALE ��pN ACCESS (I 8�� y4IN) CLIENT: ETH cV+RIsTv�'�'�nLL 1111:2°. ANTI eROIECT NAME59 R�CH�OND128� RDRp,WN DATE' RAHENSBURY Q2 t BY: R�MpUN 516-222�285 101412018 12.oWA'TS ID FIRE pLAN `"' Vil WillWiglA lDN sa DATE: DEgCR1PT D��yGTf[I,E� VISION NOTES: 0111001 Doe 64 M Ny 12130 �nsburY• yw 6bb0�R�13057 ,�. Ewa "°'' R.IIIIIW �,daa.m°•"°"` plea@ 5'�r309-278b SHINGLE ROOF 1 SPECS 1 sr-r /- RAFTEX SIZES 2x8 1--- mit r 1,11t r- 521• RAFTER SPACING(In): la 13'-Ot .0' i/ 3'-101" / , 35.-1i" 4- ROOF MATERIAL: ASPHALT eq 1-... . ARRAY 1 SPECS ‘ t 4 , - • 1 , ' \ • • • • • II • • '''. 1 ' • • TILT r): 32' AZIMUTH r): 245" SQUARE FEET(ft2) 604 I • 41 , • • • 0 • • • • I • 0 • * • • •I • • 0 0 I I* — 41) * * * t 1 : , .. g e o e * e 4 * /\\ • I ' • • • tt * e e I - * */ I • , I I • . • - • 4 .- * * 0 , * * • • / . / , \ 1 13%.0t A ()MOUNTING DETAIL ,1 I 16.-21" A SCALE: NTS 1 1 co A RRAY LAYOUT - ROOF 1 0 AZIMUTH:265' SCALE: NTS Soler PAodul 00000111 W...00,,.. IronRidge XR-100• I....Foot noshing-Low Prol Composite S: • 5/1tr LAG 1111111111 (Minimum 2.5'thread penetreBon) 64 wt. t REVISION NOTES: DATE 1 DRAWN i 1 I PROJECT NAME: CLIENT: SCALE: I , 1 Queensbury,NY 12864 REV t REV BY DATE DESCRIPTION BY: RAETH CHRISTIAN RAETH LD 10/4/2018 ROOF MOUNT 58 RICHMOND HILL DR 6660 Joy Road osseenieteseseeremessismeeereiesnesieagepp But Syncuse,NY 13057 , ' DA CHECK 12,000 WATTS QUEENSBURY,NY 12084 DRAWING TE: 1 , I I BY: , sala@spexEdarpower.com 518-222-0288 NUMBER: (518)-309-2786 DRAWING TITLE: MODULE LAYOUT 1 OF 2 • INVERTER LABELS-ONE FOR EACH INPUT PHOTOVOLTAIC AC DISCONNECT MODULE ELECTRICAL SPECIFICATIONS INVERTER SPECIFICATIONS DESIGN COMMONS ELECTRICAL KEY: AU.SOLAREDGE INPUTS MAXIMUM AC OPERATING CURRENT 47.5A (40)TRINA TSM300OOOSA.05(II) SOLAREDGE SE11400H-US HIGHEST 2%OB DESIGN TEMP('C): 31 .r_ BREAKER Vopp=360V NOMINAL OPERATING AC VOLTAGE 240V SNORT CIRCUIT CURRENT(Isc): 9.64 RATED WATTS(EACH): 11400 MIN.MEAN EXTREME ANNUAL DB('C): -29 -/`— SWITCH wise.50W OPEN CIRCUIT VOLTAGE(Voc): 39,9 AC OPERATING VOLTAGE(V): 240 0 SCREW TERMINAL WIT H TH NO STRING COMBINATIONS OPERATING CURRENT(IMP): 9.16 AC OPERATING CURRENT(A): - 47.5 co FUSE Iopp•6.27A OPERATING VOLTAGE(VMP): 32.7 NUMBER OF M PPT CHANNELS 2 Ir. EARTHSPUCE GROUND Ise=10.96A INVERTER EFFICIENCY: .99 r77 CHASSIS GROUND INPUTS WITH(2)STRING COMBINATIONS INTEGRATED DC DISCONNECT ———GEC Iopp=16.54A EGC Ise=21.96A LINE-SIDE TAP (6)#10 PV-Wire {6}#10 THHN LI&L2 FROM AC DISCONNECT (6)#6 BARE GRD (3)#4 THHN TO USE 3 PORT#POLARIS BLOCKS FREE AIR (3)#6 THHN GRD (1)#6 THHN GRD (3)#4 THHN {3}#4 THHN GENERAC AUTOMATIC 3/4"EMT 1"EMT (1)#6 THHN GRD (1)#6 THHN GRD TRANSFER SWITCH 1"EMT 1"EMT 200A j AC DISCONNECT rJ --- ALL PANELS EQUIPPED WITH (1)SOLAREDGE SE11400H-US AC DISCONNECT 60AMP SERVICE -- / METER SOLAREDGE P320 POWER NEMA 3R 60AMP SERVICE RATED FUSABLE OPTIMIZERS SOLADECK INVERTER W/INTEGRATED DC DISCONNECTS RATED NON-FUSIBLE (2)-60A FUSES �,,(.INPUT 1 LI STRING 1 + L.- _ ___`_ ____ __ ----) NEUTRAL FROM AC DISCO 14 MODULES DC OUTPUT LOAD LINE LOAD LINE TO BE LANDED IN NEUTRAL -- -- 1 BUS BAR r aINPUT 2 STRING2 + L....._-.—__--.--- 12 MODULES T_ _ __ DC= FULL LOAD BACK-UP m ao +m FEEDS TO MSP -- GENERATOR 200A-MAIN BREAKER MAKE:GENERAC 200A-BUS RANTING �INPUT3 40 STRING2 9 f--_ ---__ ...,—________ _____ ... + 14 MODULES �,,�.►' INVERTER GEC IRREVERSIBLY SPLICED TO EXISTING DEC OR BONDED CELLULAR CE DIRECTLY TO EXISTING KITGROUNDING ELECTRODE l4,V KEVIN J. °II' I C.' WOOL 7, FOR ILLUSTRATIVE PURPOSES ONLY 1A ° ' ELECTRICAL INSTALLATION SHALL CONFROM TO APPLICABLE PROVISIONS OF THE NEC AND BCNYS 4• A'1 ALL ELECTRICAL WORK SHALL BE INSPECTED BY A CERTIFIED ELECTRICAL INSPECTOR,AND r 1. 11; , VERIFICATION OF INSPECTION PROVIDED TO LOCAL BUILDING DEPARTMENT,PRIOR TO USE [,. I' CONDUIT ELEVATION:1/2 TO 3-1/2"=22°C Z,�+� '' '`' % HIGH AMBIENT TEMPERATURE:31°C 200 x 1.2=240 O 4078552.1 / EXTREME LOW:-29°C 240-200(MCB)=40A SOLAREDGE SE11400H-US MAX CURRENT=47.5A '.'. i ROOFTOP AMBIENT TEMP:53°C=0.76 MAX ALLOWABLE AC PV BREAKER=40A MAX DESIGN CURRENT=47.5A X 1.25=59.375A=BOA BREAKER/FUSES S s1C3S',~' CONDUIT FILL:1 64 Main Street I REVISION NOTES: DRAWN DATE: I PROJECT NAME: 1 CLIENT: SCALE: e,. x«v".«°„aa.w arrrs.a°u I., '�my'NY 12804 REV REV BY DATE ` DESCRIPTION B — RAETH "CHHRI STIAN RAETH ,n«,t�da a� «e 6660 Joy Road I IID 0I4 1$ — ROOF MOUNT RICHMOND HILL DR C: oey°OrMettAutaCAD4Apet So*v°.°r Nam.bwaoi Eat Syracuse,NY 13057 CHECK DRAWING DATE: f r.. 12,{300 W QUEENSBURXr NY i i sales@opexsoiatpower.com BY: .. I NUMBER: (518)-309-2786 — —. --.. I DRAWING TITLE:THREE-LINE DIAGRAM P-04 I Mono Multi Solutions ._ ♦ *THE • Ax pLusf , A /10 FRAMED 60-CELL MODULE • 60 CELL MONOCRYSTALLINE MODULE • POWER OUTPUT RANGE 192°A. MAXIMUM EFFICIENCY - Maximize limited space with top-end efficiency •Up to 192W/m2 power density •Low thermal coefficients for greater energy production at high operating temperatures o N win s , POSITIVE POWER TOLERANCE z. Highly reliable due to stringent quality control vA0 Founded in 1997,Trina Solar is the world's leading L§ •Over 30 in-house tests(UV,TC,HF,and many more) comprehensive solutions providerfor solar energy. •In-house testing goes well beyond certification requirements we believe close cooperation with our partners is •PID resistant critical to success.Trina Solar now distributes its •100%EL double inspection PV products to over 60 countries all over the world.Trina is able to provide exceptional service • Selective emitter,advanced surface texturing to each customer in each market and supplement our innovative,reliable products with the backing of Trina as a strong,bankable partner.We are committed to building strategic,mutually Certified to withstand the most challenging beneficial collaboration with installers,developers. environmental conditions distributors and other partners. •2400 Pa wind load •5400 Pa snow load Comprehensive Products •35 mm hail stones at 97 km/h And System Certificates I EC 6121 S/I E C61730/U L1703/I E C61701/I EC62716 ISO 9001:Quality Management System ISO 14001:Environmental Management System IS014064:Greenhouse gases Emissions Verification OHSAS 18001:OccupManagement alth and Safety LINEAR PERFORMANCE WARRANTY Management System j .�.�. i "``°� 10 Year Product Warranty•25 Year Linear Power Warranty e� I f . a .00.�•..� I i i A• —0--w—---i c 90°r° Additional value frprR Trina Solars lin Il s I va PV`�L[ -� ear Warran ty c T 80%, S • 1 1 I rina solar Years 5 r0 15 25 �Trina Linear Warranty Standard Step Warranty I ALLMAX'pLUs4 FRAMED 60-CELL MODULE PRODUCTS POWER RANGE ELECTRICAL DATA(STC) TSM-DD05A.08(11) 280-315W TSM-DDO5A.05(11) 275-310W Peak Power Watts-Pm.(Wp)* 275 280 285 290 295 300 305 310 315 Power Output Tolerance-Pm.(W) 0-+5 Maximum Power Voltage-Vwp(V) 31.4 31,7 31.8 32.2 32.5 32.6 32.9 33.1 33.3 DIMENSIONS OF PV MODULE(mm/inches) Maximum Power Current-hire(A) 8.76 8.84 8.97 9.01 9.08 9.19 9.28 9.37 9.46 947/373 -�-- Open Circuit Voltage-Voc(V) 38.4 38.4 38.5 38.9 39.6 39.8 40.0 40.2 40.5 - Short Circuit Current-lsc(A) 924 9.42 9.51 9.66 9.68 9.77 ' 9.85 , 9.94 10.0 Junction eoa f n :^Q Module Efficiency ryn(%) 16.8 17.1 17.4 17.7 18.0 18.3 18.6 18.9 19.2 12 l�l J STC:Irradiance 1000W/ma,Cell Temperature 25°C,Air Mass AM1,5. xamepaee *Measuring tolerance:±3%. 1 I[ W ELECTRICAL DATA(NOCT) 0 AL JA I Maximum Power-Pm.(Wp) 205 209 212 216 220 223 227 231 235 b Maximum Power Voltage-Veep(V) 29.1 29.4 29.5 i 29.9 ; 30.1 i 30.2 30.5 30.7 ' 30.9 e• Maximum Power Current-Irapr(A) 7.04 7.10 7,21 7.24 , 7.30 7.38 7.46 7.53 7.60 4-09a4 Installing twee Open Circuit Voltage-Voc(V) j 35,7 35.7 35.8 ; 36.2 i 36.8 l 37.0 '. 37,2 ; 37,4 37,6 / 6@ 43 Grounding Hole \ Short Circuit Current-Isc(A) 7.46 7.61 7.68 7.80 7.82 7.89 7.95 8.03 8.10 12-Drain tore_ \M NOCT:Irradiance at 800W/m2,Ambient Temperature 20°C,Wind Speed 1m/s. � is - // - -`' MECHANICAL DATA 35/1.38 992/39.1 Back View Solar Cells Monocrystalline 156.75 x 156.75 mm(6 inches) Cell Orientation 60 cells(6 x 10) r11/0.43 _ Silicon sealant Module Dimensions 1650 x 992 a 35 mm(65.0 a 39.1 x 1.38 inches) Laminate PAIIIMII Weight 18.6 kg(41,0Ib) M Glass 3.2 mm(0.13 inches),High Transmission,AR Coated Tempered Glass n, Backsheet White[DDO5A.08(il)]; Frame • ' Black[DDOSA.05(11)] I- - --I 35/1.38 Frame Black Anodized Aluminium Alloy[DDO5A.08(II),DDOSA.05(II)] (A-A) )-Box : IP 67 or IP 68 rated Cables Photovoltaic Technology Cable 4.0mm2(0.006 inches2), I-V CURVES OF PV MODULE(305W) 1000 mm(39.4 inches) 10A Connector ' MC4 so Fire Type Type l or Type 2 zo t s.o a 4.0 .., --.-- --. - -- . TEMPERATURE RATINGS MAXIMUM RATINGS 3.0 1.0 NOCT(Nominal Operating Cell Temperature) 44°C(±2°C) Operational Temperature -40-+85°C 0 10 m VonagOM 40 50 Temperature Coefficient of Promo -0.39%/°C Maximum System Voltage 1000V DC(IEC) Temperature Coefficient of Voc -0.29%/°C 1000V DC(UL) P-V CURVES OF PV MODULE(305W) Temperature Coefficient of Isc ' 0.05%/°C Max Series Fuse Rating 15A(Power 1285W) 350 1000W/m' 20A(Power 2290W) 8 300 0 rii\-_ - (DO NOT connect Fuse in Combiner Box with two or more strings in zoo parallel connection) g 1s o100 -- WARRANTY PACKAGING CONFIGURATION i 10 year Product Workmanship Warranty Modules per box:30 pieces 25year Linear Power WarrantyModulesper 40'container:840 pieces voltageM (Please refer to product warranty for details) CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Ti na SO l a 1r ©2017 Trina Solar Limited.All rights reserved.Specifications included in this datasheet are subject to change without notice. Version number:TSM_EN_2018_C www.trinasolar.com v) soIarT [ jCC W Single Phase Inverter with HD-Wave Technology CC for North America I I I SE3000H-US/SE3300H-US/SE5000H-US/ SE6000H-US/SE7600H-US/SE10000H-US/SE11400H-US Z t „-.,nx _ r -." :.,t x " : s -sue .x . . r aa " � ' ,.:.1,-- e: ,,' ,F?o,,_a� ,.- .,'-'' ' solar 1D wove 0, ': �r° r e . o soIari' ,HD„,,_ v ram'-iS%sc`" 3 .r' ' j-' " •H.N •••• ... a _.'_i fi:. '-,1:- :''' 0 • '0 AL: ,;,,. ,..,;: „:,.„,,,,:i.„.,,,„ 1 ,4,,,a R y 0 :., , ,,,,:„.,,,, ' � ,,,,,,,, :.,,,,... ,_,.„..,_;,,,,.._,,,,,t.,,,,,z.,„,,c0,,,..m., :?_.;...,,,„,,s,:,,_,,,_s;____., ,,,,,,:, ,,;_.,t..,":„Ak,w,_ :_,,:,,_,_,..„.„,,1„, $--.4,-,T-07.-,--:' -,-..*04,-,--;-:*--,-,- ,-,..4,:--2:: :-;-,-1„:,-,:2,--:= -,...,4,;---"zi.,—,,r,7,--,,,- � " �� -�`z t �s ,�� - fir' - . ' -:§ Y.:. 4- . _t,4: ,. %,v- - . ., :,F..a. -«*� r sue - 1,, .„, - Optimzed installation with H -Wave technology _ - Specifically designed to work with power optimizers - Record-breaking efficiency' ▪ Fixed voltage inverter for longer strings - Integrated arc fault protection and rapid shutdown for NEC 2014 and 2017,per article 690,11 and 690.12 UL1741 SA certified,for CPUC Rule 21 grid compliance a Extremely small — High reliability without any electrolytic capacitors von - Built-in module-level monitoring Illifiiiiiiillim. — Outdoor and indoor installation wave — Optional: Revenue grade data,ANSI C12.20 Class 0.5(0.5%accuracy) www.solaredge.us f SO _' ! r. r-ar .. , . MI Single Phase Inverter with HD-Wave Technology for North America SE3000H-US/SE3800H-US/SE5000H-US/ SE6000H-US/ SE7600H-US/SE10000H-US/ SE11400H-US I SE3000H-US j SE3800H-US i SE5000H-US [ SE6000H-US 1 SE7600H-US 1 SE10000H-UST SE11400H-US T OUTPUT Rated AC Power Out 3800 @ 240V 6000 @ 240V Output 3000 5000 � 7600 10000 11400 � VA 3300 @ 208V 5000 @ 208V 3800 @ 240V ' 6000 @ 240V Max.AC Power Output 3000 5000 7600 10000 11400 VA 3300 @ 208V 5000 @ 208V AC Output Voltage Min.-Nom:Max. (183-208-229) - ✓ ./• .... ... . .. Vac AC Output Voltage Min.-Nom.-Max. ✓ ✓ j ✓ ✓ / �/ ,/ Vac (211 240 264) .1................. ................1_................ AC Frequency(Nominal) 59.3-60-60.5() Hz Maximum Continuous Output Current - 16 24 A 208V Maximum Continuous Output Current 12.5 16 21 25 32 42 47.5 A @240V GFDI Threshold 1 A Utility Monitoring,Islanding Protection, Yes Country Configurable Thresholds INPUT Maximum DC Power @240V 4650 5900 I 7750 I 9300 11800 15500 17650 W Maximum DC Power @208V - 5100 1 - I 7750 - - - Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V - 9 - 13.5 - - - Maximum Input Current @240V 8.5 10.5 13.5 i 16.5 20 27 30.5 Adc Max.Input Short Circuit Current 45 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 600kn Sensitivity Maximum Inverter Efficiency 99 99.2 ry CEC Weighted Efficiency 99 % Ni httime Power Consum lion <2.5 W ADDITIONAL FEATURES --- ---.------__�____. Supported Communication Interfaces RS485,Ethernet,ZigBee(optional),Cellular(optional) Revenue Grade Data,ANSI C12.20 Optional(2) Rapid Shutdown NEC 2014 and 2017 Automatic Rapid Shutdown upon AC Grid Disconnect 690.12 STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Canadian AFC'according to T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 3/4"minimum/14-6 AWG 3/4"minimum/14-4 AWG DC Input Conduit Size/#of Strings/ 3/4"minimum/1-3 strings/ AWG Range 3/4 minimum/1-2 strings/14-6 AWG 14-6 AWG Dimensions with Safety Switch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 21.3 x 14.6 x 7.3/540 x 370 in/mm x 185 Weight with Safety Switch 22/10 I 25.1/11.4 26.2/11.9 38.8/17.6 lb/kg Noise <25 <50 dBA Cooling Natural Convection I Natural convection Operating Temperature Range -13 to+140/-25 to+60(3)(-40°F/-40°C option)(4) °F/°C Protection Rating NEMA 3R(Inverter with Safety Switch) (1)For other regional settings please contact SolarEdge support (2)Revenue grade inverter P/N:SExxxxH-US000NNC2 0)For power de-rating information refer to:https://www.solaredge.com/sites/default/files/se-temperature-Berating-note-na.pdf (4)-40 version P/N:SExxxxH-US000NNU4 Erg RoHS ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE.the SolarEdge logo,OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:07i201.8/V01,ENG NAM.Subject to change without notice. . ,. s+C' Q a r _ I # :. LU NJ SolarEdge Power Optimizer 2' ., Module Add-On For North America P300 / P320 / P400 / P405 Eby 'rr m 4„,,,_ ;, ,p r^ €� r s ii-A t4ty,yrr-y', `« ,ax v i yy�'� 9.r�f�j ,',�°1 .4,1: .,.. "c.• ;'t,. `'^' . .,,, �• ?, k g 4... .9 x t?.ri3 41 ,b4.1 •€ r F '• '5 .',..A .. x 3 .- {. "s aNN . ' ,- rt3 f '7 4 ,;- - " ,. .;, s , h •''' ' ."` ct ,- 1:- ,,ice 3 -- : 76C ,.-!".- 11.;i:,,,yvi'7.k:::,I -; z . T stf .-�i;.`r 9 "k ',�: Ong- F . =4, .�„ `4 yam.;: v?.y" ;i-.1 . y t"\ ' `,' S. �t #- `+�).i j ' A F'Sm.- '# "fi f1 T' Y -, ' 3Yc i"� 5 f f ]� -/� . .'hmy ; ` -0-744 !." x "4e1�}�'t ", . f ,J , X 4 u x' r' f / x ,, Y , , ,. „,• , .,, ,,,„„t,_ ‘,.,,,, ,I.,7,,,,...„...,-,, 4,,, ,.. „„, 4••••., 3..• �1F. !�� L t-�Art, t} y"�Ac �C' -"2.` /`��3. �` �' 1 ( 7 i. � �ri .fig»'g ,**,s ' ., `"' 4 "'` s: .:_ -.k, ,, fit,.,z - ta•• k k r d i. 'Y. PV �T p0 �C optimization atthe modul e-level .Up to 2s5g.r o re£i' ar Superior efficiency(99.5%) Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading • Flexible system design for maximum space utilization — Fast installation with a single bolt .. Next generation maintenance with module-level monitoring a Module-level voltage shutdown for installer andWiirefighter safety USA-CANADA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-UK-ISRAEL WWW.solaredge.us . , : solar - I • Imp: SolarEdge Power Optimizer Module Add-On for North America _ P300 / P320 / P400 / P405 P300 Oar 60-tell modules) P320 (for high-power 60-cell modul_Lits. P400 P405 (for 72&96-cell (for tlTinfil m- ——-- —— modules) modules) INPUT Rated Input DC Powerm 300 320 400 405 W Absolute Maximum Input Voltage 48 80 125 Vdc (Voc at lowest temperature) MPPT Operating Ran0e 8-48 8-80 12.5-105 Vdc Maximum Short Circuit Current(Isc) 10 11 10.1 Adc Maximum DC Input Current 12.5 13.75 12.63 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvottage Category II OUTPUT DURING.OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 I 85 L Vdc __ OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power 1 Vdc Optimizer - STANDARD COMPLIANCE EMC FCC Part15 Class il.,IEC61660-6-2,1k61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes __L itistALLATiOrOptancATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters 128 x 152 x27.5/ 128 x 152 x 35/ 128 x 152 x 48/ Dimensions(W x L x H) mm/in 5 x 5.97 x 1.08 5 x 5.97 x 1.37 5 x 5.97 x 1.89 Weight(including cables) 760/1.7 830/1.8 1064/2.3 .0r tib Input Connector MC4 Compatible Output Wire Type j Connector Double Insulated. Output Wire Length 0.95/3.0 1 MC4 Compatible 1.2/3.9 m/ft Operating Temperature Range -40-+85/-40-+185 'C/'F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % ill Rated SIC power of the module.Module of up to+5%power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER12) Minimum String Length -" 8 10 18 (Power Optimizers) Maximum String Length 25 25 50 (Power Optimizers) Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths Yes or Orientations It is not allowed to mix P405 with P300/P400/P600/P700 in one string. %-• CE a all . . , , KEVIN J. WOOD, P.E. CIVIL&ENVIRONMENTAL ENGINEERING October 16,2018 Mr.Rob Reynolds Apex Solar Power 64 Main Street nu Queensbury,NY 12804 SA Re: Solar Panel Project—Raeth Residence IS .� 3 0 20 B 58 Richmond Hill Dr,Queensbury,NY OC ENSBUR`>f Dear Mr.Reynolds: .TOWN OF G&coos BU1LDIN I've completed my review of the proposed solar panel installation on the ..• - at the subject location. Per your request,I determined whether the existing rafter configurations would adequately support the additional solar panel weight. I also calculated expected rooftop wind loads for this building at this location. Photovoltaic solar panels are proposed to be installed on one main house roof plane. According to the house plans dated May 2017(titled Country Manor 1 Proposed Residence at 58 Richmond Hill Dr, Queensbury,NY by Hodorowski Homes),the roof is framed with prefab engineered trusses spaced 24" on center. The trusses are overlain with 7/16"OSB sheathing and a single layer of 235#asphalt roofing shingles. Additional roof details are provided on the enclosed calculation sheets. According to information provided by Apex: The solar panels will be Trina TSM300 mounted to aluminum racking. The racking will be Ironridge XR-100 rail mounted to the roof with Ironridge L-Feet, which use integral flashing and a 5/16"diameter lag screw to secure the array to the rafters below. A summary of my evaluation follows: First the existing roof dead loads(rafters,sheathing,roofmg,etc..)were determined. According to the solar panel manufacturer's information,each panel is approx 3.25'x 5.4' and weighs 41 lbs. The panels will be grouped into arrays positioned on the roof in a southerly facing orientation. Since there will be several,relatively small point loads distributed over the surface of the roof,this was treated as a distributed load. The dead load due to the solar panels was determined to be 2.8 psf,including the racking. The live loads(snow loads)were then determined using the procedures in ASCE 7-10. Since the panels will lie close to,and parallel with,the roofline,there isn't expected to be an increase in snow load as a result of the placement of the panels. A ground snow load of 50 psf was used. Site specific exposure conditions were determined using GIS aerial imagery. 3 HORICON AVE,GLENS FALLS,NY 12801 (518)796-1859 KJWD 11 @;GMAIL.COM RAETH 10/16/18 - PG 2 R_ Next,the calculated roof dead load and live load were compared to the design loads stated on the building plans. The wind load was then calculated using the procedures in ASCE 7-10. There are several factors which effect wind load,and these are stated on the enclosed calculations. A 115-mph wind speed(3-sec gust) was used for the analysis. Conclusions&Recommendations: The calculated roof dead and live loads were found to be less than the design loads,therefore the existing trusses should be capable of carrying the additional solar panel weight. The calculated rooftop wind load for this building in this location was determined to be 21.0 psf. The resulting shear and uplift forces are shown on the enclosed calculation sheets. It is imperative that the contractor provide appropriate flashing or other watertight seal around all roof penetrations. Further,the panels must be installed in a manner which does not restrict the normal roof drainage patterns. All system components must be installed in accordance with manufacturer's instructions. While consideration was given to snow drifting,it is highly recommended that the owner not allow excessive snow or ice buildup on the roof,as with any roof. Please contact me at(518)796-1859 if you wish to discuss this project further or if site conditions are not as described in this report. Sincerely, Kevin J.Wood,P.E. of}' WOOD Stet ` Co .fir, Enc. cc: C.Raeth RAETH RESIDENCE ENGINEERING REPORT PREPARED BY: 58 RICHMOND HILL DR SOLAR PANEL PROJECT KEVIN J.WOOD, P.E. QUEENSBURY, NY OCTOBER 2018 PAGE: 1 OF 2 ROOF 1- 7:12 MAIN HOUSE ROOF- ENGINEERED TRUSSES 24"OC - ASPHALT SHINGLE ROOFING PER BUILDING PLANS TITLED COUNTRY MANOR 1 PROPOSED RESIDENCE AT 58 RICHMOND HILL DR BY HODOROWSKI HOMES DATED MAY 2017: DESIGN ROOF DEAD LOAD= 10 PSF DESIGN ROOF LIVE LOAD= 50 PSF CALCULATED DEAD LOADS(DL)= ASPHALT SHINGLES(SINGLE LAYER)= 2.5 PSF 7/16"OSB SHEATHING= 2.4 PSF RAFTERS= 0.6 PSF EXISTING DL= 5.5 PSF PROPOSED SOLAR ARRAY: 3.25'X 5.4'PANELS @ 41 LBS EA= 2.3 PSF ALUMINUM FRAME = 0.5 PSF ARRAY DL= 2.8 PSF TOTAL DL= 8.3 PSF 8.3 PSF < 10 PSF SO OK FOR DL CALCULATED LIVE LOAD SNOW LOAD(LL)= GROUND SNOW,Pg =50 PSF (PER ASCE 7-10) TERRAIN CAT=B PARTIALLY EXPOSED RISK CATEGORY=II Ce= 1.0 Ct=1.1 Is=1.0 FLAT ROOF SNOW LOAD: Pf=0.7(1.0)(1.1)(1.0)(50 PSF)= 38.5 PSF Cs= 1.0 FOR ASPHALT SURFACE @ 7:12 PITCH FOR Ct=1.1 SLOPE ROOF SNOW LOAD,Ps=Pf TOTAL LL= 38.5 PSF 38.5 PSF < 50 PSF SO OK FOR LL RAETH RESIDENCE ENGINEERING REPORT PREPARED BY: 58 RICHMOND HILL DR SOLAR PANEL PROJECT KEVIN J.WOOD, P.E. " 04 QUEENSBURY, NY OCTOBER 2018 PAGE: 2 OF 2 WIND LOAD = RISK CATEGORY= I (PER ASCE-7-10) BASIC WIND SPEED,V= 115 MPH,3 SEC GUST DIRECTIONALITY FACTOR,Kd= 1.0 EXPOSURE CATEGORY= B SURFACE ROUGHNESS= B TOPOGRAPHIC FACTOR,Kzt= 1.0 GUST EFFECT FACTOR,G= 0.85 VELOCITY PRESSURE EXPOSURE COEFFICIENT,Kz= 0.62 VELOCITY PRESSURE,Qz= 0.00256 X Kz X Kzt X Kd X VA2= 21.0 PSF VERT PROJECTED AREA,Av= (3.25')(SIN 32)(5.4') = 9.3 SF SHEAR FORCE= 196 LBS HORIZ PROJECTED AREA,Ah=(3.25')(COS 32)(5.4') = 14.9 SF UPLIFT FORCE= 313 LBS