SOLAR-0697-2018
TOWN OF QUEENSBURY
742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201
Community Development - Building & Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number: SOLAR-0697-2018Date Issued: Wednesday, December 5, 2018
This is to certify that work requested to be done as shown by Permit Number
SOLAR-0697-2018
has been completed.
316.9-1-27.1
Tax Map Number:
271 BIG BAY RD
Location:
Beth Portuese, THOMAS PORTUESE
Owner:
Solar Liberty Energy Systems Inc
Applicant:
This structure may be occupied as a: Residential Solar Panel Installation
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the
Director of Building & Code Enforcement
Planning Board or Zoning Board of Appeals.
illiiihk TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201
Community Development - Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: SOLAR-0697-2018
Tax Map No: 316.9-1-27.1
Permission is hereby granted to: THOMAS PORTUESE
For property located at: 271 BIG BAY RD
In the Town of Queensbury,to construct or place at the above location in accordance with application together
with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform
Building Codes and the Queensbury Zoning Ordinance
Type of Construction
Owner Name: Beth Portuese Solar Panel-Residential $13,000.00
Owner Address: 271 BIG BAY RD Total Value $13,000.00
Queensbury,NY 12804
Contractor or Builder's Name/Address Electrical Inspection Agency
Solar Liberty Energy Systems Inc
6500 Sheridan DR,Suite 120
Buffalo,NY 14221
Plans&Specifications
Residential Solar Panel Installation
$ 75.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Thursday,November 7,2019
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before e expiratio i at;)
Dated at the To of Que bury4
1 ‘,:ay,November 7,2018
1
SIGNED BY: for the Town of Queensbury.
Director of Building&Code Enforcement
•y Office Use Only
Permit#: r40C4-•'2.-oteb
Fee: $ (1-"J
742 Bay Road,Queensbury, NY 12804 Invoice#: 1 E)11—
P:518-761-8256 www.queensbury.net
SOLAR PANEL PERMIT APPLICATION
• Property Owner(s):
Name(s): Tom Portuese
Mailing Address, C/S/Z: 271 Big Bay Road Queensbury, NY 12804
Cell Phone:_( ) 516 680 0674 Land Line: _(
Email: tom.portuese@yahoo.com
Project Address: 271 Big Bay Road Queensbury, NY 12804 TECEOVEF
Section Block Lot:
Nov 0 5 2018
Existing Use: ® Single Family ❑ 2-4 Family ❑ Commercial 0 Other:il_
TOWN OF QUEENSBURY
• Solar Contractor: BUILDING&CODES
Business Name: Solar Liberty Energy Systems, Inc.
Contact Name: Kelli Wilson
Mailing Address, C/S/Z: 6500 Sheridan Drive Suite 120. Buffalo, NY 14221
Cell Phone:_( ) Land Line: _( ) 716 634 3780
Email: kelli.wilson@solarliberty.com
• Electrical Contractor:
Business Name:
Contact Name:
Mailing Address, C/S/Z:
Cell Phone:_( ) Land Line:_(
Email:
Contact Person for Building & Code Compliance: &At \AI A,S
Cell Phone: ( ) Land Line: ( )
Email:
Solar Panel Application Revised December 2017
Estimated cost of construction: $ 13,000
Total System Capacity Rating (sum of all panels):
Solar PV System: 4.02 kW DC
Select System Configuration:
l Supply side connection with micro inverters
❑ Supply side connection with DC optimizers
❑ Supply side connection with string inverter
❑ Load side connection with DC optimizers
❑ Load side connection with micro inverters
❑ Load side connection with string inverter
Please sign below to affirm that all answers are correct and that you have met all the
conditions and requirements to submit a unified solar permit.
rito fl4 ;-Parn eie-
Thomas Portuese(Oct 22,2018) Oct 22,2018
Homeowner's Signature Date
L1 1012�1g
Solar Co. epresentative Signature Date
Solar Panel Application Revised December 2017
Jan. 4. 2U19g 1 :45PMU MU'Ay"� L cg`<. `"mot '� ..-•No. bN4 r. 11� n-
iw ' .-, ._ •? �..? . a:. "" art;,• �•r-
go
. ``ti`✓� �aa..i�s✓�.ti _.` �i u ='�r�e�3Cc�'v` , �$:•. r
-
A- MIDDLE DEPARTMENT INSPECTION AGENCY, INC. >>
rna that the electrical wiring to the electrical equipment listed below has been examined and is approved as '
•
' being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date G-'
kfa noted below and is issued subject to the following conditions.
A;'
.Cs� Owner: Tom Portuese Date: (G
•y,� 12/12/2018 -1
Occupant:
q
C Solar PV System Location;z71 Big Bay Road `.ti
L�l
5 Y Occupancy' . Queensbury, Warren Co_ NY gi
Single Family Owg.
kg Applicant: 5
Solar Liberty Energy System • i�5
tt; 6500 Sheridan Drive �,
Suite 12000
"�) L Buffalo, NY 14221 • • J S
ktivJ
, Joseph A.Holmes CS
No.
`*t 141542107574EL
Equipment: 0
�c, 12 - Solar Modules; 1 - Production Meter; 1 -'Back Fed Breaker; 12 - Micro Inverters; 1 -AC Disconnect ;t
. '.
tia) C�'��
. C
Via)4. ;�.
This certificate applies to the electrical wiring to the electrical equipment listed Immediately null and void. This certificate applies only to the use,occupancy and ((((.
above and the installation inspected as of she above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy or ownership )
:ti inspection. No warranty is expressed or implied as to the mechanical safety,eft- of the property indicated above,this certificate snall be immediately null and void. 0
1 cienCy or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes Invalid based upon the above conditions.
be valid for a period Of one year from the above noted date. Should the electrical this certificate may be revalidated upon remspection by Middle Department
y� system to which this certificate applies be altered in any way,including but not limit- Inspection Agency,Inc. An application for inspection must be submitted to Middle t4uZ
4. ed to,the Introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc. to initiate the inspection and revalidation Fg.5
any of the components installed as of the above noted date,this certificate Shall be process. A fee Will be charged for this service. f
t:c; r: • ' v c1- .. ;:�'.4. -camV. �.s ,ca ••�• R ^:r3: +SF• .: S J>-`,: s :yA.,_,.,...............,.._....,,_y .•+ 4,°'{
,.�. ,fi vet s .+G.,v �:/'- ., n.'\.,�,- ,iG�r 4 , a G ,�. .�, y,�y v. a
:,'/t`.tit r1 e,:`- .,.; ,:�'�`�a�,.vr�sv :v.%:�{�{+1'r�r3.G�{V Lr-`n.=��/.v�ti�.:+.4� `���..�-.VCt..t�. �V ,`: 'rr+�' ,
SQ)1/4---vk a-- ' l ko
r_.
r 1,:t.„, .6„, 1..L; it ,,,,,,,„1 ,.., .0 \
i JAN ®42019
1-,� N �jt�E�:NS t� B�'Y
13U1��►���1N0 Qt �E.S
DATE: 11/01/18
Michael Prinzi
Senior Project Manager, Solar Liberty D C E I W IE
6500 Sheridan Drive Suite 120
Buffalo, NY 14221 NOV 0 5 2018
RE: 271 Big Bay Road, Queensbury, NY 12804 TOWN OF QUEENSBURY
BUILDING&CODES
Dear Michael,
As per your request we conducted a Preliminary Structural Condition assessment that included
a site inspection on 10/02/18. This inspection included an examination of the roof structure and
condition as well as any structural drawings that were available.
PV solar panels are proposed for the larger, south facing roof areas as summarized below. The
panels are mounted on rails which are attached to the roof with an anchored deck base system
and installed per manufacturer's specifications and recommendations.
It was found that the roof structure noted on Site Plan PV-S1 and Structural Detail PV-S3 can
satisfactorily withstand the proposed additional loads and will meet the applicable standards
included in the NYS 2017 Uniform Code Supplement, ASCE 7-10, and 2015 IRC.
The loads considered are:
Wind load = 115 mph
Snow load = 50 psf
Roof dead load = 9.4 psf
Solar System Dead Load = 3.13 psf
The total existing load on the areas of the roof where panels are to be installed was found to be
9.4 psf.
The roof was determined to have a single layer of asphalt shingles atop half inch plywood
sheathing.
Overall the roof area is structurally adequate to support the additional load of the solar panels
and their framework.
Acknowledged by:
David C.Hemandez,P.E.,C.E.M.
NY PE No.097026
11/01/18
��,bF NEW yp "IT IS A VIOLATION OF SECTION
!_�c'' 'ej" 7209 OF ARTICLE 145 OF THE
3 STATE EDUCATION LAW OF
T•.;��, NEW YORK FOR ANY PERSON TO
;rig, ALTER ANY DOCUMENT THAT
BEARS THE SEAL OF A
870 PROFESSIONAL ENGINEER,
/ UNLESS THE PERSON IS
ACTING UNDER THE DIRECTION
OF A LICENSED PROFESSIONAL
ENGINEER."