Loading...
SOLAR-0774-2018TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: SOLAR-0774-2018 Date Issued: Thursday, April 4, 2019 This is to certify that work requested to be done as shown by Permit Number has been completed. SOLAR-0774-2018 Tax Map Number: Location: Owner: 301.12-2-43 39 HEINRICK CIR Joan DeCaro, Mark DeCaro Applicant:Solar Liberty Energy Systems Inc This structure may be occupied as a: Residential Solar Panel Installation Roof Mounted By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board or Zoning Board of Appeals. Director of Building & Code Enforcement TOWN OF QUEENSBURY /".7 75- 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development - Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: SOLAR-0774-2018 Tax Map No: 301.12-2-43 Permission is hereby granted to: Mark DeCaro For property located at: 39 HEINRICK CIR In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Joan DeCaro Solar Panel-Residential $22,000.00 Owner Address: 39 HEINRICK CIR Total Value $22,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency Solar Liberty Energy Systems Inc 6500 Sheridan DR, Suite 120 Buffalo,NY 14221 Plans&Specifications Residential Solar Panel Installation Roof Mounted $ 75.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Tuesday,December 10, 2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To u sbury 4 M i a / -= ber 10, 2018 14 SIGNED BY: ' \ for the Town of Queensbury. Director of Building&Code Enforcement iosw Office Use Only } {. Permit#: ail-At— 9"1 • ?.Q �J 1 F Fee: $ rj 742 Bay Road,Queensbury, NY 12804 Invoice#: I 13, %a P:518-761-8256 www.queensbury.net SOLAR PANEL PERMIT APPLICATION • Property Owner(s): Name(s): Joan and Mark DeCaro Mailing Address, C/S/Z: 39 Heinrick Circle Queensbury, NY 12804 Cell Phone: _( ) 518 928 2471 Land Line: _( ) Email: jdecaro2@nycap.rr.com Project Address: 39 Heinrick Circle Queensbury, NY 12804 Section Block Lot: Existing Use: ® Single Family ❑ 2-4 Family ❑ Commercial ❑ Other: • Solar Contractor: Business Name: Solar Liberty Energy Systems, Inc. Contact Name: Kelli Wilson Mailing Address, C/S/Z: 6500 Sheridan Drive Suite 120 Buffalo. NY 14221 Cell Phone: _( ) Land Line: _( ) 716 634 3780 Email: kelli.wilson@solarliberty.com • Electrical Contractor: Business Name: U Contact Name: DFC OR 7fl18 Mailing Address, C/S/Z: - Cell Phone: _( ) Land Line: (TOWN O QUEENSBURY Email: — tiUILU!NG&CODES Contact Person for Building & Code Compliance: Cell Phone: ( ) Land Line: ( ) Email: Solar Panel Application Revised December 2017 Estimated cost of construction: $ 22,000 Total System Capacity Rating (sum of all panels): Solar PV System: 7.56 kW DC Select System Configuration: ❑ Supply side connection with micro inverters ❑ Supply side connection with DC optimizers ❑ Supply side connection with string inverter ❑ Load side connection with DC optimizers ® Load side connection with micro inverters ❑ Load side connection with string inverter Please sign below to affirm that all answers are correct and that you have met all the conditions and requirements to submit a unified solar permit. 9a bbCara- Marc betard Joan DeCaro Mark DeCaro(Nov 7,2018) Nov������ Homeowner's Signature Date Solar Co. Representative Signature Date Solar Panel Application Revised December 2017 . ► DATE: 11/19/18 Michael Prinzi Senior Project Manager, Solar Liberty 6500 Sheridan Drive Suite 120 Buffalo, NY 14221 I, G E U v E D RE: 39 Heinrick Circle, Queensbury, NY 1280, DEC 0 6 2018 Dear Michael, TOWN &CODES QUEENSBURY . . As per your request we conducted a Preliminary Structural Condition assessment that included a site inspection on 10/23/18. This inspection included an examination of the roof structure and condition as well as any structural drawings that were available. PV solar panels are proposed 3 roof areas as summarized below. The panels are mounted on rails which are attached to the roof with an anchored deck base system and installed per manufacturer's specifications and recommendations. It was found that the roof structure noted on Site Plan PV-S1 and Structural Detail PV-S3 can satisfactorily withstand the proposed additional loads and will meet the applicable standards included in the NYS 2017 Uniform Code Supplement, ASCE 7-10, and 2015 IRC. The loads considered are: Wind speed = 115 psf Snow load = 50 psf Roof dead load = 9.4 psf Solar System Dead Load = 3.2 psf The total existing load on the areas of the roof where panels are to be installed was found to be 9.4 psf. The roof was determined to have single layer of asphalt shingles atop half inch plywood sheathing. Installation is to be avoided on the north side of roof 1 as per PV-S1, S2, S3. This is due to water damage on a rafter. Overall the roof area is structurally adequate to support the additional load of the solar panels and their framework. Acknowledged by: David C. Hernandez, P.E., C.E.M. NY PE No.097026 /19,.5 Of NEW k "IT IS A VIOLATION OF SECTION 41/4VpG.HEA 040 7209 OF ARTICLE 145 OF THE • STATE EDUCATION LAW OF C $ yf` NEW YORK FOR ANY PERSON TO ALTER ANY DOCUMENT THAT BEARS THE SEAL OF A 0 pROFBest0-�, PROFESSIONAL ENGINEER, UNLESS THE PERSON IS ACTING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL FN(INFFR" r . �.. — - BPS , tztel � SunPower® X22-360-C-AC 1 Residential AC Module Series Design-Driven Advantages 022 • #1 module aesthetics and efficiency' • Unmatched module reliability2 SERIES • No electrolytic capacitors s . . . ._. • 25-year Combined Power and Product Warranty Maximize Value for Roof . • Size system for roof, not string inverter • ' r_ • Optimize performance of each module + -. .- . a Expand Deployment Options ` • Complex roofs and partial shading • Small systems • System expandability Simplify & Speed Installation Optimize System and Installation Efficiency • Factory-integrated microinverter Robust,double locking AC connectors SunPower''AC Modules,which include a factory-integrated •• Design flexibility offsite and onsite SunPower microinverter, provide a revolutionary combination of high • No DC string sizing process efficiency, high reliability,and module-level DC-to-AC power conversion. • Fewer installation steps than competing systems Designed specifically for use with SunPower InvisiMountlM and the • Intuitive commissioning SunPower Monitoring System,SunPower AC Modules enable rapid installation,best-in-class system aesthetics,and intuitive visibility into Component of Complete System Built for use with SunPower' ',nvisiMount" system performance.All this comes with the best Combined Power • and the SunPower Monitoring System an. P •• . • i. . : industry. • Superior system reliability and aestheticsPI n LI DEC 062018 NSB iRY V N OF C. `tS a0 L r, G& OE r i �� sunpower.com Darasi[e S U N P W E R` _ 1 s .. r e,.13a i ✓ w mow-. <..,:_.r ._ a„ "w...,+ .+ SunPower° X22-360-C-AC I Residential AC Module Series Power Data Tested Operating Conditions SPR-X22-360-C-AC Operating Temp. -40°F to-185°F(-40°C to-85°C) Nominal Power1(Pnom) 360 W Max.Ambient 122° F(50°C) Power Tolerance +5/-0% Temp Avg. Panel Efficiency° 22.2% Max Load Wind:62 psf,3000 Pa,305 kg/m2 front&back Temp.Coef.(Power) 0.29%/°C Snow: 125 psf, 0 Pa,611 g/m2 front •Three bypass diodes Impact Resistance 1 inch(25 mm)diameter hail at 52 mph(23 m/s) Shade Tolerance • Integrated module-level maximum power — point tracking Warranties and Certifications • AC Electrical Data Warranties 25 year limited power warranty • 25-year limited product warranty Output @ 240 V(min./nom./max.) 21 1/240264 V UL listed to UL 1741,including: Output @ 208 V(min./nom.lmax.) 183/208/229 V l • IEEE1547/1547a and IEEE1547.1/1547.1 a Utility Operating Frequency(min./nom./max.) 59.3/60.0/60.5 Hz { Interactive Output Power Factor(min.) 0.99 • PV Rapid Shutdown Equipment AC Max.Continuous Output Current @ 240 V 1.33 A • Equipment Grounding AC Max.Continuous Output Current @ 208 V 1.54 A • UL 6703,UL 9703 Connectors and cables(load AC Max.Cont.Output Power 320 W break disconnection) • UL 1703 PV Modules(Type 2 fire rating) DC/AC CEC Conversion Efficiency 96.0% Max.Units Per 20 A Branch Circuit @ 240 V 12(single phase) Certifications Enables installation in accordance with. Max.Units Per 20 A Branch Circuit @ 208 V 10(two pole) • NEC 690.6 No active phase balancing for 3 phase • NEC 690.12 Rapid Shutdown(inside and outside installations the array) • NEC 690.15 AC Connectors,690.33(A)-(E)(1) FCC and ICES-003 Class B Mechanical Data Solar Cells 96 MonocrystatI tie Maxeon Gen III When used with InvisiMount racking(UL 2703) • High-transmission tempered glass with Integrated grounding and bonding Front Glass • Class A fire rated anti-reflective coating Environmental Rating Outdoor rated PID Test Potential-induced degradation free Frame Class 1 black anodized(highest AAMA rating) Weight 45 5 lbs(20.6 kg) A 280 m Recommended Max. 1.3 in.(33 mm) ���� Module Spacing III ���� Ir[43.60/minm1 si) ,.■ 7 V��,� Ew 1046 min 30 mm � Ind In i1.2 in1 'Highest of over 3,200 silicon solar panels,Pnoton Module Survey,Feb.2014 1. #1 rank in"PV Module Durability Initiative Public Report,'Fraunnofer CSE,Feb 2013 Five out of ... :he top erghr largest manufacturers were tested Campeau,Z et al"SunPower Module 1558„,,, f [61.3❑,i Degradation Rate, SunPower wage paper:Feb 2013.See NAMw sunpower.corni acts'oi details. -Sta idard Test Conditions(1000 W/m°irradiate e.AM I S,25°q NREL calibration standsr i SO ds cw rent LACCS FF and voltage.All DC voltage is fully contained within'tie module Based on a era e o measured power values during production Please read the safety and installation instructions for details See imam,sunpowet con/facts fc,r more re'erence infer wation For more details,see extended datasheet www cu tpower comidatasneets Document#516046 Rev D/LTR-US ©December 2016 SunPower Corporation.All ogres reserved.SUNPOWER,the SUNPOWER logo,MAXEON and InvisiMount �+ r n are trademarks or registered trademarks of SunPower Corporation in the US-an her cni ties as Sp•>n5 tines J C K included in this datasheet are subject to change witnout notice. To: Page 1 of 1 2019-03-29 20:08:37(GMT) 15183146044 From: Joseph Holmes - ,1 : J _.i — ..... .. n...a...:.:.._ _ - , ::.'i:,.':'':'-::`: is — ..• .— ... .,. .—..:...-.� i::�.�::.:..:. !,C;fQ_..,•/L_.Al:•...:_,��':��=�C.FS,_.:..:.--��;��'�4:h<1'r►'�f',� ,,��Ar..�;c.�:,�.�r..... .. . f i i - .. _ -