ResCheck REScheck Software Version , , Compliance Certificate Project McNeice Project Energy Code: 2015 IECC 201$ Location: Lake George, New York (�C-0549- Construction Type: Single-family 226.19-1-20 Project Type: New Construction McNeice, Laura Conditioned Floor Area: 1,640 ft2 Glazing Area 17% 12 Chestnut Ln 1650 s.f. Climate Zone: 6 (7377 HDD) SFD wlgas FP Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: McNeice Family Frank Jelley NY NY 518-796-5611 Compliance: Passes using UA trade-off Compliance: 0.0%Better Than Code Maximum UA: 283 Your UA: 283 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Assembly Perimeter R-Value .R-f fue Ceiling 1: Flat Ceiling or Scissor Truss 912 49.0 0.0 0.026 24 Wall 1:Wood Frame, 16"o.c. 2,244 21.0 0.0 0.057 104 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 332 0.260 86 Door 1:Solid 42 0.280 12 Door 2: Glass 41 0.280 11 Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 816 30.0 0.0 0.033 27 Floor 2: Slab-On-Grade:Heated 28 10.0 0.684 19 Insulation depth: 4.0' Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the perm' ap 'c ion.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.4 and to ply7pvi ndatory requirements listed' the REScheck Inspection Checklist.. Frank aA �/ Name-Title \ Si nature Dat _ 5ECEllViEn � ` 9ft AUG 2 4 2018 Q,Jp ♦` V TOWN OF QUEENSBURY BUILDING&CODES Project Title: McNeice Project •• :a e: 08/07/18 Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 1 of 9 k SoftwareVersion Inspection Checklist rs Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section I Plans Verified `` Field Verified 4 # Pre-Inspection/Plan Review Value I Value Complies? Comments/Assumptions & Req.11i 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2 documentation demonstrate DDoes Not [PR1]' energy code compliance for the 0,, building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies Requirement will be met. 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ElComplies Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not 1(PR212 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods ❑Not Observable Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: i 1 High Impact(Tier 1) 1 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McNeice Project Report date: 08/07/18 Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 2 of 9 Section i i 1 & Re ID Foundation Inspection PlansValue Verified I FieldValuefied Complies? Comments/Assumptions q 402.1.2 Slab edge insulation R-value. R- R- ElComplies See the Envelope Assemblies [FO1]1 ❑ Unheated ❑ Unheated ❑Does Not table for values. ❑ Heated ❑ Heated ['Not Observable ❑Not Applicable 402.1.2 Slab edge insulation ft ft ❑Complies See the Envelope Assemblies [FO3]1 depth/length. El Does Not table for values. ❑Not Observable _ ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies Requirement will be met. [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a ['Not Observable minimum of 6 in. below grade. ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is [FO12)2 controls installed. ElDoes Not not applicable. ['Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 Project Title: McNeice Project Report date: 08/07/18 Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 3 of 9 1 Section ? ` Plans Verified Field Verified s f # Framing/Rough-In Inspection] Value Value , Complies? Comments/Assumptions 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. (FR1]1 ['Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ❑Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies Requirement will be met. [FR4]1 are determined in accordance ['Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable — 402.4.1.1 Air barrier and thermal barrier ❑Complies Requirement will be met. [FR23I1 installed per manufacturer's ❑Does Not instructions. ❑Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies Requirement will be met. [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies Requirement will be met. 1[FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate 5.2.0 cfm leakage at 75 Pa. ['Not Observable ❑Not Applicable r- 403.2.1 Supply and return ducts in attics ❑Complies Requirement will be met. [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where< 3 inches.Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>=3 inches and R-4.2 for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies Requirement will be met. [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ❑Not Applicable ,403.4 HVAC piping conveying fluids R- R- ❑Complies Requirement will be met. [FR17]2 above 105°F or chilled fluids ['Does Not ! below 55°F are insulated to>_R- I 3 [Not Observable E ❑Not Applicable 403.4.1 Protection of insulation on HVAC ❑Complies Requirement will be met. [FR24]1 piping. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies Requirement will be met. [FR18]2 >_R-3. ❑Does Not I ' ❑Not Observable I ❑Not Applicable /403.6 Automatic or gravity dampers are —~ ❑Complies Requirement will be met. [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. [Not Observable ElNot Applicable I 1 High Impact(Tier 1) i 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McNeice Project Report date: 08/07/18 Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 4 of 9 ( Section 1 Insulation Inspection Plans Verified ` Field Verified j p p i , Value i Value Complies? Comments(Assum tions & Req.lR z-- i --, 303.1 All installed insulation is labeled ❑Complies Requirement will be met. [IN13]2 or the installed R-values ❑Does Not provided. ['Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ['Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ❑Not Observable ❑Not Applicable 303.2, Floor insulation installed per ❑Complies Requirement will be met. 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the underside of the subfloor, or floor ['Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ['Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass Li Mass ❑Not Observable [IN3]1 exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies Requirement will be met. (IN4]1 manufacturer's instructions. ❑Does Not "Not Observable I ❑Not Applicable Additional Comments/Assumptions: • 1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McNeice Project Report date: 08/07/18 Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 6 of 9 Section I Plans Verified ; Field Verified # Final Inspection Provisions Complies? I Comments/Assumptions & Req.1Dy }- Value Value J— y 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ❑Not Observable 402.2.E ❑Not Applicable pplicable 303.1.1.1, Ceiling insulation installed per ElComplies Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable 1- — 402.2.3 Vented attics with air permeable ElComplies Requirement will be met. [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met. [FI3]1 insulation >_R-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies Requirement will be met. [FI17)1 ach in Climate Zones 1-2, and ElDoes Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 402.4.2 Wood-burning fireplaces have ElComplies Requirement will be met. [FI8]2 tight fitting flue dampers and ❑Does Not outdoor air for combustion. [Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ElComplies Requirement will be met. [FI4]1 cfm/100 ft2 across the system or ft2 ft2 El Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ElComplies Requirement will be met. [FI27]1 determine air leakage with ft2 ft2 ❑Does Not I either: Rough-in test:Total leakage measured with a ENot Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met. [FI24]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies Requirement will be met. [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ElComplies Exception: Requirement is [FI10]2 on heat pumps. ❑Does Not not applicable. [Not Observable ❑Not Applicable 11 High Impact(Tier 1) L 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McNeice Project Report date: 08/07/18 Data filename: C:\Fj\Arch Design\Trevor McNeice\McNeice Project.rck Page 7 of 9 Section Plans Verified E Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re11.I0. — - 403.5.1 Circulating service hot water ❑Complies Requirement will be met. [FI11]2 systems have automatic or ElDoes Not accessible manual controls. ❑Not Observable ❑Not Applicable 403.6.1 All mechanical ventilation system ElComplies Requirement will be met. [F125J2 fans not part of tested and listed ElDoes Not HVAC equipment meet efficacy and air flow limits. ['Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ElComplies Requirement will be met. [FI26]2 through one-or two-pipe heating ElDoes Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ElComplies Requirement will be met. f[F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies Exception: Requirement is [FI29]2 comply with IEEE 515.1 or UL ElDoes Not not applicable. 515.Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ['Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies Requirement will be met. [F130]2 have recirculation pumps that ElDoes Not pump water from a heated water supply pipe back to the heated [Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units ElComplies Requirement will be met. [F13112 tested in accordance with CSA ElDoes Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to _ three or more showers. 404.1 75%of lamps in permanent ElComplies Requirement will be met. [FI6]1 fixtures or 75%of permanent ElDoes Not fixtures have high efficacy lamps. Does not apply to low-voltage Not Observable lighting. ❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McNeice Project Report date: 08/07/18 Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 8 of 9 II Section # Final Inspection Provisions Plans Verified Field Verified Complies? Comments/Assumptions & RegJD+i — -- — -- Value Value (404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met. [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 401.3 Compliance certificate posted. OComplies Requirement will be met. [F►7]2 ElDoes Not ❑Not Observable :Not Applicable 303.3 Manufacturer manuals for ❑Complies Requirement will be met. [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McNeice Project Report date: 08/07/18 Data filename: C:\FJ\Arch Design\Trevor McNeice\McNeice Project.rck Page 9 of 9 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 0.00 Floor 30.00 Ceiling/ Roof 49.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.26 Door 0.28 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments