Loading...
CC-0792-2018TOWN OF QUEENSBURY 742 Bay Road, Queensbury, NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: CC-0792-2018 Date Issued: Friday, April 5, 2019 This is to certify that work requested to be done as shown by Permit Number has been completed. CC-0792-2018 Tax Map Number: Location: Owner: 296.18-1-5 63 QUAKER RD 63 Quaker LLC 63 Quaker LLCApplicant: This structure may be occupied as a: Commerical Alterations 8515 s.f. Tenant: Benjamin Moore, 3048 s.f.By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Planning Board or Zoning Board of Appeals. Director of Building & Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: CC-0792-2018 Tax Map No: 296.18-1-5 Permission is hereby granted to: 63 Quaker LLC For property located at: 63 QUAKER RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: 63 Quaker LLC Retail-Mercantile-Alteration $15,000.00 Owner Address: 217A Boght RD Total Value $15,000.00 Watervliet,NY 12189 Contractor or Builder's Name/Address Electrical Inspection Agency J&P Builders Plans&Specifications Commerical Alterations 8515 s.f. Tenant:Benjamin Moore,3048 s.f. $ 0.00 PERMIT FEE PAID -THIS PERMIT EXPIRES: Monday,December 16, 2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of sbury; nd r 14,2018 SIGNE)BY: for the Town of Queensbury. Director of Building&Code Enforcement Office Use Only C- , - 'r°I2.- ?�48 ADDITION/ALTERATION PERMIT Permit#: C ` APPLICATIC . 1 1 2018 '`s Permit Fee:$ `:? C Y, 742 BayRoad,Queensbu NY 12804 I 1 rY, T{3lVN OF rlb;3EENSU invoice It: 1 P:518-761-8256 ,,srwW.queensbury.net in St Ifs DI , &COCES Project Location 4' f, ' Tax Map ID #: 7/(>, . ( I /"_ .5, Subdivision Name: /5e--I' �UN'Nn‘r '-� 00- CONTACT INFORMATION: U • Applicant: , Name(s): , ) Qt =ti .Z Mailing Address, C/S/Z: i t 1- ,l:''•, . ( : t. tC- t--111 I l ` Cell Phone: ( , ) 3 t-t 45 "°`1 Land Line: ( ) Email: vv"\ %c,v\ t-A, - e.►Av"A iv in --C `) A )1- 7e- 41 r''- 4,) • Primary Owner(s): i , Name(s): cj; a: C Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( ) Email: • Contractor(s): Business Name: 14-P 13,\V s Contact Name(s): -:)::-Al..'S ,-, •,it. .. Mailing Address, C/S/Z: Cell Phone: ( 9't v ) 71 S ) (= 4 Land Line: ( ) Email: • Architect(s)/Engineer(s): `L Business Name: 1'> Kla I 1-6\1lr-;- i% •-e Contact Name(s): 1 \ i:- Mailing Address, C/S/Z: 11-` (1 .,. - L` _, Cell Phone: (:�7 �' ) � ' L� d s '-, Ci 3 Land Line: ( ) � � Email: 'Y r-t,-: :._ L Kte(7?;:'; -._---.,:t2 ` c..' 1.1 Contact Person for Building& Code Compliance: (it ii ` 1 Cell Phone: ( ."- .. ) 3t j i' O -/ Land Line: ( ) Email: OAk(. \ i � .. .rl ,Z —1s' ? ' 424i 4444, ,7" , -ifr ) v.,_ Town of Queensbury Budding&Code Enforcement AcditaoniAkerahoc Apphcatton Revssed March 2018 PROJECT INFORMATION: TYPE: $ Commercial Residential WORK CLASS: Single-Family Two-Family _Multi-Family(#of units _Townhouse —Business Office Retail Industrial/Warehouse Garage(#of cars ) Other(describe ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 1st floor: 1 211 floor: 2nd floor: 3rd floor: 3rd floor: Basement(habitable space): Basement(habitable space): Total square feet: Total square feet: 04a ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction:$ / .aJ c? 2. If Commercial project,what is the proposed use: e.4f 3. Source of Heat (circle one): "„Gas; Oil Propane Solar Other Fireplaces need a separate Fuel Burning Appliances&Chimney Application 4. Are there any structures not shown on the plot plan? YES NO Explain: S. Are there any easements on the property? YES NO 6. SITE INFORMATION: a. What is the dimensions or acreage of the_ -parcel? b. Is this a corner lot? YES NQ c. Will the grade be changed as a result oe construction? YES d. What is the water source? PUBLIC" PRIVATE WELL e. Is the parcel on SEWER or a PRIVATE SEPTIC system? Town of Queensbury Buiading&Code Enforcement Addition/Alteration Application Revised March 2018 • DECLARATION: 1. I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: In X(i SIGNATURE: 4" DATE: ] - /t) Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 INSPECTION WORKSHEET (BINS-001689-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0792-2018 Case Module:Permit Inspection Date:Mon Apr 1, 2019 Inspection Status:Failed Inspector:John O'Brien Inspection Type:Commercial Final Inspection Job Address:Parcel Number:63 QUAKER RD Queensbury, NY 12804 296.18-1-5 Contact Type Company Name Name Primary Owner 63 Quaker LLC Fiacco, Michael Applicant 63 Quaker LLC Fiacco, Michael Granted Permission 63 Quaker LLC Fiacco, Michael Contractor J & P Builders Checklist Item Passed Comments Exits At Grade Or Platform 36 (w) x 44 (l)YES - Repair tripping hazard at front Door HVAC Vent Terminal 10' from Lot Line & Openings NO -Complete mechanicals -HVAC Balance Report Handicapped Service Counters 34 inch NO -Install Service Counter to be installed Tuesday 4/2/19 Bldg Num or Tenant Address on Bld or Drive NO -Install Suite Number Special Inspections NO - Submit HVAC Air Balancing Report for A&A Beauty & Benjamin Moore if one unit handles both spaces. OK to Issue Temporary C/O NO Apr 01, 2019 Page (1) INSPECTION WORKSHEET (BINS-001689-2019) Checklist Item Passed Comments OK to Issue C/O NO 3/15/19 Final Inspection Not Approved Remaining Items: -Repair tripping hazard at front Door -Complete mechanicals -Install Suite Number - Submit HVAC Air Balancing Report for A&A Beauty & Benjamin Moore if one unit handles both spaces. -Complete Fire Marshal's Items -Install Service Counter 4/1/19 Final Inspection Not Approved -Complete mechanicals -HVAC Balance Report -Install Service Counter to be installed Tuesday 4/2/19 -Install Suite Number Apr 01, 2019 Page (2) O'Brien, John (Inspector) C C ZZ \ David Sellers Mechanical, Inc. AIR MOVEMENT EQUIPMENT TEST SHEET 180 Jenni Jill Dr., Warrensburg, NY 12885 63 Quaker Road, Queensbury, NY 12805 518-623-9760 Mark Plaza Paint Store Beauty Store SYSTEM: RTU-1 Location Roof Service Paint Store and Beauty Supply Store Manufacturer York Model ZXG08EZC1AA1B111A1 Serial Number NIC4527538 Date Tested 4/4/2019 Indoor Fan Motor Frame 56HZ HP 3.7 RPM 1725 Voltage 208/230 3 phase AS BUILT F.L. Amps 3.7 Measured Amps 3.3 Motor Sheave 1VP50 Blower Sheave AK74 Test Data CFM Paint Store Beauty Store Test 1 Test 2 Test 3 Test 1 Test 2 Test 3 1 235 241 165 172 2 313 322 275 295 3 150 155 275 289 4 180 191 275 301 5 216 223 219 247 6 245 20 165 182 7 212 223 220 251 8 224 232 Total CFM 1775 1607 0 1594 1737 0 INSPECTION WORKSHEET (FM-001667-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0792-2018 Case Module:Permit Inspection Date:Thu Mar 28, 2019 Inspection Status:Passed Inspector:Gary Stillman Inspection Type:OCC-Inspections Job Address:Parcel Number:63 QUAKER RD Queensbury, NY 12804 296.18-1-5 Contact Type Company Name Name Primary Owner 63 Quaker LLC Fiacco, Michael Applicant Fiacco, Michael Granted Permission 63 Quaker LLC Fiacco, Michael Contractor J & P Builders Checklist Item Passed Comments Fire Marshal YES Exit Access YES Exit Enclosure YES Exit Discharge YES Locks and Latches YES 1. REPAIR LEVER HARDWARE AT FRONT DOOR 2. REMOVE REMAINING LOCK PART ON JAM REAR WAREHOUSE DOOR 3/28/19 CORRECTED Sign: Normal YES Mar 28, 2019 Page (1) INSPECTION WORKSHEET (FM-001667-2019) Checklist Item Passed Comments Sign: Backup YES Main Aisle Width YES Secondary Aisle Width YES Fire Extinguisher Hung YES Inspection of Extinguisher YES Emergency Lighting Interior YES Clearance to Electrical YES Electrical Wiring Enclosed/Labeled YES Combustibles in Equipment Rooms YES F.D. Signage YES Storage YES Interior Finishes YES CO Detectors YES Clearance to Sprinkler/Ceiling YES Occupancy Cycle YES B Mar 28, 2019 Page (2) Stillman, Gary (Inspector) tr>V<t 15. 2019C11 33AM= 1 M0IA•-::.� �; .•, .f- .�• ,y-;a.- yT,.,N0. 7652 P, 4/4 �b � ,-i\Ja..r- .r:�✓�S%f>✓:✓a,.••.�✓`��;:'',�.i�.:.'~�:2+C�,frf.v'ti 4>^.e. s;^h`C�o;,. ',�rf"'�j':.`} • ,.. MIDDLE DEPARTMENT INSPECTI N AGENCY, INC.-(tAA, / 15j • (eenl ies that the electrical wiring to the electrical equipment listed b low has been examined and is approved as Y �j being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date , C�'� dry noted below and is issued subject to the following conditions. (6 Y' Owner: Date: 6,, t‘. Benjamin Moore 03/12/2019 rr,' 0 Occupant: Locatio • t•••> 1St Floor �63 uaker Rd. . � O �i) ccupancy�on-Residential Queensbury, Warren Co- NY _0 Applicant: CC_ t 9 2--- 2,0ti`v Mike Fiasco • :...;.._....: • - _ Y le 63 Quaker Rd. ,• -�. E W E. i'l Queensbury, NY 1280E _ ,,,,,, - ,,e, . . D S Via «.. y MAR 15 [ell �;') No. Joseph A.Holrnes.: ` •• :5 „~• -'-TOW•N OF( UEENSBURY �F; _- ':1475621086.57EL. •--' - :;...''' '_ .'.. . ..... - (t'•.'�1 • DES ,, Equi• pment: r,F�� 1 - 100 Amp. Sub Panel; 4-Switches;•31 -Receptacles, 41 Ptxtures, 1 30Amp Receptacle;,'1 -Vent Fan, 6 - a �)'9:;ExIt/Emergency Combos • N �(�.}}, 01 rii,) ,,,; rr,l >t- r: ' :'F �j `Yo k.c� This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and «[(�" %., above and the installation inspected as of the above noted date based on a visual ownership as indicateb herein. Upon a change the use,occupancy or ownership ti% Oinspection. No warranty is expressed or implied as to the mechanical safety,effi- of ma property indicated above,this certificate shall be immediately null and void. v ) `ca Cienry or fitness of the equipment for arty particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, be valid lot a period of one year froth the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department g ) system to which this certificate applies be altered in any way,including but not limit- Inspection Agency.In':. Art application for inspection must be submitted to Middle ) ed to.the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc. to Initiate the Inspection and revalidation `(.? any of the components installed as of the above noted date,this certificate shall be process. A lee will belcherged for this service. �r. :ti.% �.� r�.�v:�• -�-r .;r'r� ••r?.•r;:�:i;•�:ti � • �. g \^�•".`•' . ,•'�`_�.,..�. -,. ;� � �, ♦ ti�7� ♦•;Gam/•.• fi. r �S '/,=•.F- r� � ,c. ysti% v'—� •� �i,y i r .c. -.�G�..;C; �iui�i.}�� so:kti zeis:J"`•,;'��`r;cCa�cFJ"t>Sr:! rr a .;,,a 4 d4• •1.,.,C'4 �.: I �♦i.i,,k {:,; <?.<.:.t. ,C, G: t•�..' � -r�•�ti.v`i�v ,L � +vw:T•v'na.=�, .,. r'�,.}�'��>?.�^;.%..��'Y:✓� ✓. �u �. :J"✓r ♦:1 f+ Y� r INSPECTION WORKSHEET (BINS-001389-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0792-2018 Case Module:Permit Inspection Date:Fri Mar 15, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Commercial Final Inspection Job Address:Parcel Number:63 QUAKER RD Queensbury, NY 12804 296.18-1-5 Contact Type Company Name Name Primary Owner 63 Quaker LLC Fiacco, Michael Granted Permission 63 Quaker LLC Fiacco, Michael Contractor J & P Builders Applicant Fiacco, Michael Checklist Item Passed Comments Exits At Grade Or Platform 36 (w) x 44 (l)NO - Repair tripping hazard at front Door HVAC Vent Terminal 10' from Lot Line & Openings NO -Complete mechanicals Handicapped Service Counters 34 inch NO -Install Service Counter Bldg Num or Tenant Address on Bld or Drive NO -Install Suite Number Special Inspections NO - Submit HVAC Air Balancing Report for A&A Beauty & Benjamin Moore if one unit handles both spaces. OK to Issue Temporary C/O NO Mar 15, 2019 Page (1) INSPECTION WORKSHEET (BINS-001389-2019) Checklist Item Passed Comments OK to Issue C/O NO 3/15/19 Final Inspection Not Approved Remaining Items: -Repair tripping hazard at front Door -Complete mechanicals -Install Suite Number - Submit HVAC Air Balancing Report for A&A Beauty & Benjamin Moore if one unit handles both spaces. -Complete Fire Marshal's Items -Install Service Counter Mar 15, 2019 Page (2) O'Brien, John (Inspector) INSPECTION WORKSHEET (FM-001388-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0792-2018 Case Module:Permit Inspection Date:Fri Mar 15, 2019 Inspection Status:Failed Inspector:Gary Stillman Inspection Type:OCC-Inspections Job Address:Parcel Number:63 QUAKER RD Queensbury, NY 12804 296.18-1-5 Contact Type Company Name Name Granted Permission 63 Quaker LLC Fiacco, Michael Contractor J & P Builders Applicant Fiacco, Michael Primary Owner 63 Quaker LLC Fiacco, Michael Checklist Item Passed Comments Fire Marshal YES Exit Access YES Exit Enclosure YES Exit Discharge YES Locks and Latches NO 1. REPAIR LEVER HARDWARE AT FRONT DOOR 2. REMOVE REMAINING LOCK PART ON JAM REAR WAREHOUSE DOOR Sign: Normal YES Sign: Backup YES Mar 15, 2019 Page (1) INSPECTION WORKSHEET (FM-001388-2019) Checklist Item Passed Comments Main Aisle Width YES Secondary Aisle Width YES Fire Extinguisher Hung YES Inspection of Extinguisher YES Emergency Lighting Interior YES Clearance to Electrical YES Electrical Wiring Enclosed/Labeled YES Combustibles in Equipment Rooms YES F.D. Signage YES Storage YES Interior Finishes YES CO Detectors YES Clearance to Sprinkler/Ceiling YES Occupancy Cycle YES B Mar 15, 2019 Page (2) Stillman, Gary (Inspector) INSPECTION WORKSHEET (FIST-001282-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0792-2018 Case Module:Permit Inspection Date:Tue Mar 5, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Firestopping Job Address:Parcel Number:63 QUAKER RD Queensbury, NY 12804 296.18-1-5 Contact Type Company Name Name Applicant Fiacco, Michael Primary Owner 63 Quaker LLC Fiacco, Michael Granted Permission 63 Quaker LLC Fiacco, Michael Contractor J & P Builders Checklist Item Passed Comments Building Inspector Notes NO 2/20/19 Fire Separation Partial Approval - Bar joists at back wall need to be stuffed with rock wool and fire caulked 3/1/19 Fire Separation Not Approved - Went over with John the contractor what needs to be completed on the Bennington Furniture side of the Benjamin Moore Tenant Demise Wall. Seal holes in wall with fire caulk, patch bigs holes in sheetrock and fire caulk and fire spray tops of demise wall. 3/4/19 Fire Separation Not Approved - Apply more Fire Spray over rock wool insulation at top of demise wall. Rock wool exposed in areas. Call for recheck. Mar 05, 2019 Page (1) INSPECTION WORKSHEET (FIST-001282-2019) Checklist Item Passed Comments Fire separation 1, 2, 3 hour YES 2/20/19 Fire Separation Partial Approval - Fire coating at top of demise walls. - Bar joists at back wall need to be stuffed with rock wool and fire caulked 3/1/19 Fire Separation Not Approved - Went over with John the contractor what needs to be completed on the Bennington Furniture side of the Benjamin Moore Tenant Demise Wall. Seal holes in wall with fire caulk, patch bigs holes in sheetrock and fire caulk and fire spray tops of demise wall. 3/4/19 Fire Separation Not Approved - Apply more Fire Spray over rock wool insulation at top of demise wall. Rock wool exposed in areas. Call for recheck. 3/5/19 Fire Separation Partial Approval -Bennington Furniture Side Penetration sealed NO 2/20/19 Fire Separation Partial Approval - Fire coating at top of demise walls. - Bar joists at back wall need to be stuffed with rock wool and fire caulked Mar 05, 2019 Page (2) O'Brien, John (Inspector) INSPECTION WORKSHEET (FIST-001267-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0792-2018 Case Module:Permit Inspection Date:Mon Mar 4, 2019 Inspection Status:Failed Inspector:John O'Brien Inspection Type:Firestopping Job Address:Parcel Number:63 QUAKER RD Queensbury, NY 12804 296.18-1-5 Contact Type Company Name Name Granted Permission 63 Quaker LLC Fiacco, Michael Contractor J & P Builders Primary Owner 63 Quaker LLC Fiacco, Michael Applicant Fiacco, Michael Checklist Item Passed Comments Building Inspector Notes NO 2/20/19 Fire Separation Partial Approval - Bar joists at back wall need to be stuffed with rock wool and fire caulked 3/1/19 Fire Separation Not Approved - Went over with John the contractor what needs to be completed on the Bennington Furniture side of the Benjamin Moore Tenant Demise Wall. Seal holes in wall with fire caulk, patch bigs holes in sheetrock and fire caulk and fire spray tops of demise wall. 3/4/19 Fire Separation Not Approved - Apply more Fire Spray over rock wool insulation at top of demise wall. Rock wool exposed in areas. Call for recheck. Mar 04, 2019 Page (1) INSPECTION WORKSHEET (FIST-001267-2019) Checklist Item Passed Comments Fire separation 1, 2, 3 hour NO 2/20/19 Fire Separation Partial Approval - Fire coating at top of demise walls. - Bar joists at back wall need to be stuffed with rock wool and fire caulked 3/1/19 Fire Separation Not Approved - Went over with John the contractor what needs to be completed on the Bennington Furniture side of the Benjamin Moore Tenant Demise Wall. Seal holes in wall with fire caulk, patch bigs holes in sheetrock and fire caulk and fire spray tops of demise wall. 3/4/19 Fire Separation Not Approved - Apply more Fire Spray over rock wool insulation at top of demise wall. Rock wool exposed in areas. Call for recheck. Penetration sealed NO 2/20/19 Fire Separation Partial Approval - Fire coating at top of demise walls. - Bar joists at back wall need to be stuffed with rock wool and fire caulked Mar 04, 2019 Page (2) O'Brien, John (Inspector) INSPECTION WORKSHEET (FIST-001308-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0792-2018 Case Module:Permit Inspection Date:Wed Mar 6, 2019 Inspection Status:Passed Inspector:John O'Brien Inspection Type:Firestopping Job Address:Parcel Number:63 QUAKER RD Queensbury, NY 12804 296.18-1-5 Contact Type Company Name Name Primary Owner 63 Quaker LLC Fiacco, Michael Contractor J & P Builders Granted Permission 63 Quaker LLC Fiacco, Michael Applicant Fiacco, Michael Checklist Item Passed Comments Building Inspector Notes YES 2/20/19 Fire Separation Partial Approval - Bar joists at back wall need to be stuffed with rock wool and fire caulked 3/1/19 Fire Separation Not Approved - Went over with John the contractor what needs to be completed on the Bennington Furniture side of the Benjamin Moore Tenant Demise Wall. Seal holes in wall with fire caulk, patch bigs holes in sheetrock and fire caulk and fire spray tops of demise wall. 3/4/19 Fire Separation Not Approved - Apply more Fire Spray over rock wool insulation at top of demise wall. Rock wool exposed in areas. Call for recheck. 3/6/19 Fire Separation Approved Mar 06, 2019 Page (1) INSPECTION WORKSHEET (FIST-001308-2019) Checklist Item Passed Comments Fire separation 1, 2, 3 hour YES 2/20/19 Fire Separation Partial Approval - Fire coating at top of demise walls. - Bar joists at back wall need to be stuffed with rock wool and fire caulked 3/1/19 Fire Separation Not Approved - Went over with John the contractor what needs to be completed on the Bennington Furniture side of the Benjamin Moore Tenant Demise Wall. Seal holes in wall with fire caulk, patch bigs holes in sheetrock and fire caulk and fire spray tops of demise wall. 3/4/19 Fire Separation Not Approved - Apply more Fire Spray over rock wool insulation at top of demise wall. Rock wool exposed in areas. Call for recheck. 3/5/19 Fire Separation Partial Approval -Bennington Furniture Side 3/6/19 Fire Separation Approved Penetration sealed YES 2/20/19 Fire Separation Partial Approval - Fire coating at top of demise walls. - Bar joists at back wall need to be stuffed with rock wool and fire caulked 3/6/19 Fire Separation Approved Mar 06, 2019 Page (2) O'Brien, John (Inspector) INSPECTION WORKSHEET (FIST-001228-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0792-2018 Case Module:Permit Inspection Date:Fri Mar 1, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Firestopping Job Address:Parcel Number:63 QUAKER RD Queensbury, NY 12804 296.18-1-5 Contact Type Company Name Name Contractor J & P Builders Granted Permission 63 Quaker LLC Fiacco, Michael Primary Owner 63 Quaker LLC Fiacco, Michael Applicant Fiacco, Michael Checklist Item Passed Comments Building Inspector Notes NO 2/20/19 Fire Separation Partial Approval - Bar joists at back wall need to be stuffed with rock wool and fire caulked 3/1/19 Fire Separation Not Approved - Went over with John the contractor what needs to be completed on the Bennington Furniture side of the Benjamin Moore Tenant Demise Wall. Seal holes in wall with fire caulk, patch bigs holes in sheetrock and fire caulk and fire spray tops of demise wall. Fire separation 1, 2, 3 hour NO 2/20/19 Fire Separation Partial Approval - Fire coating at top of demise walls. - Bar joists at back wall need to be stuffed with rock wool and fire caulked 3/1/19 Fire Separation Not Approved - Went over with John the contractor what needs to be completed on the Bennington Furniture side of the Benjamin Moore Tenant Demise Wall. Seal holes in wall with fire caulk, patch bigs holes in sheetrock and fire caulk and fire spray tops of demise wall. Mar 01, 2019 Page (1) INSPECTION WORKSHEET (FIST-001228-2019) Checklist Item Passed Comments Penetration sealed NO 2/20/19 Fire Separation Partial Approval - Fire coating at top of demise walls. - Bar joists at back wall need to be stuffed with rock wool and fire caulked Mar 01, 2019 Page (2) O'Brien, John (Inspector) INSPECTION WORKSHEET (BINS-000806-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0792-2018 Case Module:Permit Inspection Date:Thu Feb 7, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Building Framing Job Address:Parcel Number:63 QUAKER RD Queensbury, NY 12804 296.18-1-5 Contact Type Company Name Name Contractor J & P Builders Primary Owner 63 Quaker LLC Fiacco, Michael Granted Permission 63 Quaker LLC Fiacco, Michael Applicant Fiacco, Michael Checklist Item Passed Comments Building Inspector Notes NO 1/24/19 Framing Partial Approval- Interior non-bearing partitions and tenant separation wall. Verified rockwool insulation and framing along steel roof beam at tenant separation wall. 2/7/19 Framing Partial Approval - Non bearing interior partitions for bathroom, office and wall between mercantile area and backroom. Framing YES 1/24/19 Framing Partial Approval- Interior non-bearing partitions and tenant separation wall. Verified rockwool insulation and framing along steel roof beam at tenant separation wall. 2/7/19 Framing Partial Approval - Non bearing interior partitions for bathroom, office and wall between mercantile area and backroom. Feb 07, 2019 Page (1) INSPECTION WORKSHEET (BINS-000806-2019) Checklist Item Passed Comments Design Professional Sign-off, if required NO Feb 07, 2019 Page (2) O'Brien, John (Inspector) INSPECTION WORKSHEET (FIST-001039-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0792-2018 Case Module:Permit Inspection Date:Wed Feb 20, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Firestopping Job Address:Parcel Number:63 QUAKER RD Queensbury, NY 12804 296.18-1-5 Contact Type Company Name Name Applicant Fiacco, Michael Primary Owner 63 Quaker LLC Fiacco, Michael Granted Permission 63 Quaker LLC Fiacco, Michael Contractor J & P Builders Checklist Item Passed Comments Building Inspector Notes NO 2/20/19 Fire Separation Partial Approval - Bar joists at back wall need to be stuffed with rock wool and fire caulked Fire separation 1, 2, 3 hour YES 2/20/19 Fire Separation Partial Approval - Fire coating at top of demise walls. - Bar joists at back wall need to be stuffed with rock wool and fire caulked Penetration sealed NO 2/20/19 Fire Separation Partial Approval - Fire coating at top of demise walls. - Bar joists at back wall need to be stuffed with rock wool and fire caulked Feb 20, 2019 Page (1) O'Brien, John (Inspector) INSPECTION WORKSHEET (BINS-000535-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-0792-2018Permit Case Number:Case Module: Thu Jan 24, 2019Partial Pass Inspection Date:Inspection Status: John O'BrienBuilding Framing Inspector:Inspection Type: 63 QUAKER RD296.18-1-5 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName Primary Owner63 Quaker LLCFiacco, Michael Granted Permission63 Quaker LLCFiacco, Michael ApplicantFiacco, Michael ContractorJ & P Builders Checklist ItemPassedComments Building Inspector NotesNO1/24/19 Framing Partial Approval- Interior non-bearing partitions and tenant separation wall. Verified rockwool insulation and framing along steel roof beam at tenant separation wall. FramingYES1/24/19 Framing Partial Approval- Interior non-bearing partitions and tenant separation wall. Verified rockwool insulation and framing along steel roof beam at tenant separation wall. Jack Posts Main BeamsNO Design Professional Sign-off, if requiredNO O'Brien, John (Inspector) Jan 24, 2019Page (1) INSPECTION WORKSHEET (BINS-000099-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal CC-0792-2018Permit Case Number:Case Module: Fri Jan 4, 2019Partial Pass Inspection Date:Inspection Status: John O'BrienBuilding Framing Inspector:Inspection Type: 63 QUAKER RD296.18-1-5 Job Address:Parcel Number: Queensbury, NY 12804 Contact TypeCompany NameName Primary Owner63 Quaker LLC ContractorJ & P Builders Granted Permission63 Quaker LLC ApplicantFiacco, Michael Checklist ItemPassedComments Building Inspector NotesNO1/4/19 Framing Partial Approval - Steel lintel installed in masonry wall for new storefront doors. FramingNO1/4/19 Framing Partial Approval - Steel lintel installed in masonry wall for new storefront doors. Jack Posts Main BeamsYES1/4/19 Framing Partial Approval - Steel lintel installed in masonry wall for new storefront doors. Design Professional Sign-off, if requiredNO1/4/19 Framing Partial Approval - Steel lintel installed in masonry wall for new storefront doors. Note: Provide design professional sign off. O'Brien, John (Inspector) Jan 04, 2019Page (1) iIICOMcheck Software Version 4.1.0.0 i Interior Lightiog1 pla nce CertificatOR e q ,,,,,--%;4.ENERGY CODE L Project Information .^ ,-->?;/<\ - ' <se-: . Energy Code: 2015 IECC jG + r '� 1 l Project Title: RETAIL'B'(BENJAMIN MOORE) °! Project Type: Alteration \,i r ..{,:" '~,: -p f Construction Site: Owner/Agent: Designer/Contractor. _9 F OZI L4� 63 Quaker Ave Michael Fiacco Keith Buff �. Queensbury, NY 12804 63 Quaker Rd kpb Architecture Queensbury, NY 12804 PO Box 697 Clifton Park, NY 12065 Allowed Interior Lighting Power FILE COPY A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Retail 1746 1.26 2200 2-Office 1302 0.82 1068 3-Warehouse 1669 0.66 1102 Total Allowed Watts= 4369 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Retail(1746 sq.ft.) LED 1: EPANL2440L35K:2X4 LITHOINIA LED:LED Panel 38W: 1 12 39 466 Office(1302 sq.ft.) LED 2:LED Panel 38W: 1 11 39 427 Warehouse(1669 sq.ft.) LED 3:LED Panel 38W: 1 8 39 310 Total Proposed Watts= 1203 nterior Lighting PASSE Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspectio hecklist ,(Ci 'Yh t,'l- t f Ai'thc.c. t .�i t I2- v� I Na fie-Title Sign,ture Date IT::‘1 liE C E 11 %7' Lel Lil '! 2018 296.18-1-5 CC-078 DECQ�C 63 Quaker LLC .821 '2018 f► ! t ors-1(F7 9pucv ( 63 Quaker ti_:. _. ,_ Rd : s: Commercial Alterations 8515 s.f. Project--Tide----RETAIL'B' (BENJAMIN MOORE) date: 12n0/18 Data filename: A:\2018\2018.23-63 QUAKER EJ\01,Project Management\Ben Moore.cck .age 1 of 5 COMcheck Software Version 4.1.0.0 ritt interior Lighting Compliance Certificate, , ram t -,, - ti'z, r �rr <:>s R I C+f ' \ ' Project Information s ` ' -:`„t 1 Energy Code: 2015 IECC a s Project Title: RETAIL'A'(A&A BEAUTY SUPPLY) • e' Project Type: Alteration ,,1 : ., fir 1 -�y �; �' Construction Site: Owner/Agent: Designer/Contractor: �,:-'', l -`` 63 Quaker Ave Michael Fiacco Keith Buff Queensbury, NY 12804 63 Quaker Rd kpb Architecture Queensbury, NY 12804 PO Box 697 Clifton Park, NY 12065 Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Retail 2415 1.26 3043 2-Office 535 0.82 439 3-Warehouse 713 0.66 471 Total Allowed Watts= 3952 Proposed Interior Lighting Power A B C D E Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Retail(2415 sq.ft.) LED 1: EPANL2440L35K:2X4 LITHOINIA LED:LED Panel 38W: 1 22 39 854 Office(535 sq.ft.) LED 2: LED Panel 38W: 1 7 39 272 Warehouse(713 sq.ft.) LED 3:LED Panel 38W: 1 5 39 194 Total Proposed Watts= 1319 Interior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.0.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Name-Title Si a u e Date Project Title: RETAIL'A' (A&A BEAUTY SUPPLY) Report date: 12/10/18 Data filename: A:\2018\2018.23-63 QUAKER EJ\01.Project Management\AnA.cck Page 1 of 5 kpb -ciitectire ) P.O. Box 697 DEC 12 2018 ; Lb" Clifton Park, NY 12065 1 518.429.8093 TOWN OF OUEENSBU Y I BUILDING&CODES kbuff@kpbarchitecture.com Date: December 12, 2018 Re: 63 Quaker Ave—A&A Beauty and Benjamin Moore Fit-Out ADDENDUM NUMBER 1 This Addendum forms a part of the Contract Documents and modifies/clarifies the original Drawings dated December 10, 2018. Comment from John O'Brien per voicemail on December 12, 2018 1. Submit 2015 COMcheck for Mechanical Response: 2015 COMcheck for Mechanical cannot be completed because the existing roof top unit (Carrier Model#48TME007-501) does not meet the required minimum of 11.00 EER for the proposed system.The RTU was installed 8-10 years ago and the product data on the equipment shows an EER of 10.1.The unit does have a motorized economizer with a minimum adjustable setpoint to allow for fresh air intake and exhaust. END OF ADDENDUM NUMBER 1 RcO 'AR Please contact me should you have any questions. \oj� QpSRiC 49 Keith P. Buff,AIA 1 518.429.8093 - OF nL COPY jillekFIRE MARSHAL'S OFFICE 1#__ Town of Queensbury IF,4T iy 742 Bay Road, Queensbury, NY 12804 "Home of Natural Beauty ... A Good Place to Live " PLAN REVIEW FILE COPY 63 Quaker Road LLC 63 Quaker Road (2 spaces) CC-0782-2018 12/11/2018 The following comments are based on review of the submitted plans: (Benjamin Moore, A & A Beauty) 1) Fire Extinguisher locations per plan to be verified. (A001) 2) Locks / latches shall comply with the 2015 International Fire Code. 3) Carbon monoxide detection will be required Per NYS part 1228- 4) Exit/Emergency lights appear adequate; all breakers shall be properly labeled noting emergency light circuits. A function test will be required rior to CO. ( ______, puty Vire Marshal Gary K. Stillman 742 Bay Road Queensbury NY 12804 518 761 8205 garys@queensbury.net Fi re Marshal 's Office • Phone: 518-761-8206 • F a x: 518-745-4437 firetuarsital@queensbury.net • www.queensbury.net