Loading...
RC-0783-2018 TOWN OF QUEENSBURY ;r ' ..,, i 742 Bay Road,Queensbury,NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-0783-2018 Tax Map No: 239.18-1-32 Permission is hereby granted to: Sara Kelly For property located at: 17 CLIFF HOLLOW RD In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Sara Kelly Single Family-Alteration $500,000.00 Owner Address: 30 Oakwood DR Total Value $500,000.00 Queensbury,NY 12804 Contractor or Builder's Name/Address Electrical Inspection Agency CGM Construction Inc 2 Brookwood DR Waterford,NY 12188 Plans&Specifications Residential Addition: 1st floor,729 s.f.;2nd floor,408 s.f. Residential Alterations: 1st floor&garage, 1584 s.f.;2nd floor,735 s.f. Cross Ref. Area Variance 73-2018 and Site Plan Review 67-2018 $ 1,724.90 PERMIT FEE PAID -THIS PERMIT EXPIRES: Tuesday,December 17, 2019 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before expiratio R at9 ) Dated at the To of Que ry ,o December 17,2018 SIGNED BY: for the Town of Queensbury. Director of Building&Code Enforcement . 4 , Office Use Only iler,_41-1 cf\- - i4 PONTI on 4 I 01114) t -1,z2 .4.0. APPLICATION 742 Bay Road Queensbury, NV 12804 '1 P 518-761-8256 D Ont1c2618 1 ILJ ) a 1 3 1 Project Location: 17 cLifP 1-01.1..ad egiaN OF OUEENSBURY -ttn-t3tNG&CODES Tax Map #: (231• lb -1 -19._ Subdivision Name: WA TOWN BD RESOLUTION 86-2013 $850 recreation fee for new dwelling units: single family,duplexes two-family. multiplefamily apartments condominiums townhouses,and'or manufactured & modular homes but not homes. This is in addition to the permit fee(s). CONTACT INFORMATION • Applicant: Name(s). c6 f4 cOLSIZtr4101-1- l I LiC.. _ Mailing Address, C/S/Z: 1 6aczekkkro 12 0. uhyrr;pr-07....0 1 t...h I also i Cell Ph.: ( 6Is ) ,7e.9 • 76 59- Land Line: ( 6 ) 23‘ o77 Email: C_A1AJZ4jelfi21.k7112-LZ-P-1-11--IG• • Primary Owner(s): Name(s): 9b.S.AAgelAZ. Mailing Address. C/S/Z: 50 Obicaoor2 opVe..LauteJ4Jen2o . I 2b04- Cell Ph.: ( ) Land Line: ( 618_) 116• cito7 Email: V..-01,V. 9MA:r C7f-tail .__ . • Contractor(s): Name(s): Mailing Address, C/S/Z: Cell Ph.: ( ) Land Line: ( ) Email: • Architect(s)/Enqineer(sli Name(s): L2t6___12_121(13_44 _ Mailing Address, C/S/Z: _nQat2,. and Cell Ph.: 1643 i 6a6___6__6 _t__ Land Line: ( ) 6)60 669 Email: C0-69-2,1 . .,-‘ 1!) 1,..1 !) • Ci-J-4 Contact Person for Building & Code Compliance: Aealite-{ Cell Ph,: ___( ) , Land Line: ( ) Email: Tedl Madding&Cnclg Fnftwegmant Prinrinlo Strurhirg Rsivivind March?MR PROJECT INFORMATION: TYPE: Commercial Residential ' WORK CLASS: Single-Family _Two-Family _Multi-Family(#of units Townhouse Business Office _Retail Industrial/Warehouse Garage (#of cars ) _Other (describe ADDITION SQUARE FOOTAGE: ALTERATION SQUARE FOOTAGE: 1st floor: 9 1st floor: I S3`i 57G) G cart ) 2nd floor: Lidg 2nd floor: 135 3rd floor: iJA 3rd floor: Ala'I Basement (habitable space): il1A Basement (habitable space))::�1301 Total square feet: ) 3 7 Total square feet: 4f9ke` tA ADDITIONAL PROJECT INFORMATION: 1. Estimated Cost of Construction: $ S 00)Oc 2. If Commercial project, what is the proposed use: na3tfia„�:�� 3. Source of Heat (circle one): 1. Oil Propane Solar Other Fireplaces need a separate Fue :urning Appliances&Chimney Application 4. Are there any structures not shown on the plot plan? YES NO plain: 5. Are there any easements on the property? YES NO 6. SITE INFORMATION:a. What is the dimensions or acreage of the parcel? •3 & ( � 1_ SO� �i b. Is this a corner lot? YES NO c. Will the grade be changed as a result of the construction? YES NO d. What is the water source? PUBLIC PRIVAT' e. Is the parcel on SEWER or a PRIVATE SEPTIC system? Pr - C Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 f DECLARATION: 1. I acknowledge that no construction shall be commenced prior to issuance of a valid permit and will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: Ckr;sto I-ur'' G. rl cira, SIGNATURE: �.u�_,-� DATE: laj11iis Town of Queensbury Building&Code Enforcement Addition/Alteration Application Revised March 2018 DECLARATION: I. I acknowledge that no construction shall commerh,e prior to issuance of a valid building ;..ern and work will be completed within a 12 month period 2 If the work is not completed by the lyear expiration date the permit may be renewed. subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a t rue and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: e// STC%Pfir i2. 4 SIGNATURE: � - 1 � DATE: / 2 // //z9C Too Building&Code Enforcement Prinrinla ftn,rt„rr,Ravicari Marrh 7f11 R Office Use Only fl! FUEL BURNING APPLIANCE & Permit#: —o2-8 - 2018 p CHIMNEY APPLICATION Permit Fee: $ Invoice#: 742 Bay Road. Queensbu N- 12804 P 518-761-8256 Project Location: I/ d.t(tl- 1-k% - ki IZd• Tax Map ID: 23qq • I f - 1 - 32 Room of Install: Planned Install Date: **ONE APPLICATI ON PER APPLIANCE** CONTACT INFORMATION: • Applicant: Name(s): GGV1 Ct J4IIIUG4IDt.s • Mailing Address, CIS/Z: 2 612cz e. .tiZ7r) W. 1 k1/4/bl`e-F012-17 U( (2 I Cell Ph.: (610 ) 31(.9 7( 5 2 Land Line: ( SI g ) 23" 0317 Email: C.6 -11SI2C. AtW @ CH Caic3�12-t "1dk1 I t.i • C-E-vl • Primary Owner(s): Name(s): '3. 13. IL-L-U"( Mailing Address, CIS/Z: 3O oAte., coto 17ede.,, o(>e (3Orz`(, L(1' ( 2 Cell Ph.: ( ) Land Line: ( 6(8 ) 1/8 • 2I07 Email: ( 1,'1', ShU•Y @ 6k&4 - • Installer/Builder: Name(s): c3A64 .— 13 b.(90.4chof Mailing Address, C/S/Z: Cell Ph.: ( ) Land Line: i( ) Email: Contact Person for Buildi9g &Code Compliance: Gt4'(T'3 I2. t�P5 Cell Ph : ( ) b06 AD69 I Land Line: (' 18 ) L7(JU j L Email: :17''(9.7)4 @ YA(� Town of Queensbury Butidir .&Code Enforcement • FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: /' ,\Icin c `_ /_.ePA17-4-14--6io (7 /14 Stove X Fireplace Insert _Fireplace Fuel Fired Equipment(Garage Only,13"clearance per IMC 304.3) Fireplace, factory built**** Manufacturer's Name: 1.r' )U Model#: SOURCE OF HEAT: Wood Coal Pellet Leas I CHIMNEY INFORMATION: Masonry: Iblock) brick stone Flue: i✓ �ceL/ Lz To i 11 2j LSD tie (steel 1 size,in inches Material*: double-wall triple-wa Il_insulated (*Manufacturer's r-ti ra nn Model#: ADDITIONAL INFORMATION: 1 Two inspections are required. A rough-in hspection,prar to installation and a final inspection,after installation. 2 Manufacturer's installation manual must be available at the time of inspection. 3 Masonry fireplaces & chimneys require plans to be submitted. 4 Twenty-four (24) hour notification's required for nspections. peclaration:Constructionlinstaltation must conform to NYS Fire Prevention&Building Code and/or manufacturer requirements.The applicant or owner agrees to comply with all applicable taws,ordinances,regulations and all conditions that are part ofthese requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: — SIGNATURE : - C)ATE: Fuel Burning Appliance&Chimney Application Job: Manual 1 tal S Compliance Rep .. Q . Dare: oeDo�1812fi os,2018 Unite. +' B : :Lie Riverside Energy Consulting n. uhc 1 1 2018 ' rl 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyaonsulfingiagmail.com • Project Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 17269 Btuh Entering coil DB: 75.0°F Outdoor design WB: 70.8°F Latent gain: 2367 Btuh Entering coil WB: 62.5°F Indoor design DB: 75.0°F Total gain: 19636 Btuh Indoor RH: 50% Estimated airflow: 967 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: YCD30B21+CF/CM/CU3OB Actual airflow: 967 cfm Sensible capacity: 24157 Btuh 140%of load Latent capacity: 3757 Btuh 159%of load Total capacity: 27913 Btuh 142%of load SHR: 87% Heating Equipment Design Conditions Outdoor design DB: -3.5°F Heat loss: 47600 Btuh Entering coil DB: 70.0°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TG9S060B12MP11 Actual airflow: 967 cfm Output capacity: 58000 Btuh 122%of load Temp. rise: 50 °F 239.18-1-32 RC-0783-2018 Kelly, Sara Meets all requirements of ACCA Manual S. 17 Cliff Hollow Rd Res. Additions & Alt. 5333 s.f. wrightsoft 2018 Dec 06 16:13:02 Right-Suite®Universal 2018 18.0.31 RSU23464 Page 1 /1ry ih. ...NY\CliffHollow_12.6.18\CliffHollow_12.6.18.rup Calc=MJ8 Front Door faces: N Manual S Compliance Report Job: 18126 p � Date: Dec 06,2018 Unit 2 By: A Dole Riverside Energy Consulting 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyConsulting@gmail.com Project Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Cooling Equipment Design Conditions Outdoor design DB: 85.0°F Sensible gain: 9511 Btuh Entering coil DB: 75.2°F Outdoor design WB: 70.8°F Latent gain: 2147 Btuh Entering coil WB: 62.6°F Indoor design DB: 75.0°F Total gain: 11658 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split AC Manufacturer: York Model: YCD18B21+CF24ABAA1 Actual airflow: 600 cfm Sensible capacity: 17272 Btuh 182%of load Latent capacity: 1324 Btuh 62%of load Total capacity: 18596 Btuh 160%of load SHR: 93% Heating Equipment Design Conditions Outdoor design DB: -3.5°F Heat loss: 36519 Btuh Entering coil DB: 70.4°F Indoor design DB: 72.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Gas furnace Manufacturer: York Model: TG9SO40A08MP11 Actual airflow: 600 cfm Output capacity: 39000 Btuh 107%of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. W rightsoft 2018-Dec-06 16:13:02 Right-Suite®U niversal 2018 18.0.31 RSU23464 Paget ...NY\CIiffHollow_12.6.18\Cl ftHollow_12.6.18.rup Calc=MJ8 Front Door faces: N , Project SummaryJob: 18126 Date: Dec 06,2018 Entire House By: A Dole Riverside Energy Consulting 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyConsulting@gmail.com Pro'ect Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Notes: Manual J and S calculations for 17 Cliff Hollow Rd Queensbury, NY 12804.All calculations are based on plan specifications and 2015 IECC w/NY amendments. Subject to change. Desi• n Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 °F Outside db 85 °F Inside db 71 °F Inside db 75 °F Design TD 74 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 82349 Btuh Structure 26551 Btuh Ducts 1770 Btuh Ducts 229 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 84119 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 26779 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Loose Fireplaces 0 Structure 4212 Btuh Ducts 303 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling Area(ftz) 3620 3620 Equipment latent load 4515 Btuh Volume(ft3) 29471 29471 Air changes/hour 0.75 0.39 Equipment Total Load(Sen+Lat) 31294 Btuh Equiv.AVF (cfm) 368 192 Req.total capacity at 0.70 SHR 3.2 ton Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref. n/a Coil n/a AHRI ref. n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4. wri ht ft 2018-Dec-06 16:13:03 _ � Right-Suite®Universal 2018 18.0.31 RSU23464 Page 1 ACCA. ...NY CliffHollow_12.6.181CIiffHollow_12.6.18.rup Cab =MJ8 Front Door faces: N r t Project Summary Job: 18126 , 0Unit 1 By: A Dole Riverside Energy Consulting Date: Dec 06,2018 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyConsulting@gmail.com Pro'ect Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Notes: Manual J and S calculations for 17 Cliff Hollow Rd Queensbury, NY 12804.All calculations are based on plan specifications and 2015 IECC w/NY amendments. Subject to change. Desi• n Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 °F Outside db 85 °F Inside db 70 °F Inside db 75 °F Design TD 74 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 47600 Btuh Structure 17269 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) Humidification 0 Btuh Blowerne) 0 Btuh Piping Euipment load 47600 Btuh Use manufacturer's data Y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 17269 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Loose Fireplaces 0 Structure 2367 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 2099 2099 Equipment latent load 2367 Btuh Volume (ft3) 16214 16214 Air changes/hour 0.71 0.37 Equipment Total Load (Sen+Lat) 19636 Btuh Equiv.AVF (cfm) 191 99 Req. total capacity at 0.70 SHR 2.1 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK BY JOHNSON CONTROLS Trade YORK Model TG9S060B12MP11 Cond YCD30B21 AHRI ref 2008579 Coil CF/CM/CU30B AHRI ref 201926167 Efficiency 95.5 AFUE Efficiency 11.5 EER, 13.3 SEER Heating input 60000 Btuh Sensible cooling 20300 Btuh Heating output 58000 Btuh Latent cooling 8700 Btuh Temperature rise 55 °F Total cooling 29000 Btuh Actual air flow 967 cfm Actual air flow 967 cfm Air flow factor 0.020 cfm/Btuh Air flow factor 0.056 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -+d- wrightsoft 2018-Dec-0616:13:03 �_ Right-Suite®Universal 2018 18.0.31 RSU23464 Page 2 ACCA ...NY\CliffHollow_12.6.18\CliffHollow_12.6.18.rup Caic=MJ8 Front Door faces: N T, v , C Project Summary Job: 18126 4111 •J Date: Dec 06,2018 Unit 2 By: A Dole Riverside Energy Consulting 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyConsulting@gmail.com Pro-ect Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Notes: Manual J and S calculations for 17 Cliff Hollow Rd Queensbury, NY 12804.All calculations are based on plan specifications and 2015 IECC w/NY amendments. Subject to change. Desi• n Information Weather: Glens Falls AP, NY, US Winter Design Conditions Summer Design Conditions Outside db -4 °F Outside db 85 °F Inside db 72 °F Inside db 75 °F Design TD 76 °F Design TD 10 °F Daily range M Relative humidity 50 % Moisture difference 27 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 34748 Btuh Structure 9282 Btuh Ducts 1770 Btuh Ducts 229 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 36519 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 9511 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Loose Fireplaces 0 Structure 1845 Btuh Ducts 303 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1521 1521 Equipment latent load 2147 Btuh Volume(ft3) 13257 13257 Air changes/hour 0.80 0.42 Equipment Total Load (Sen+Lat) 11658 Btuh Equiv.AVF (cfm) 178 92 Req. total capacity at 0.70 SHR 1.1 ton Heating Equipment Summary Cooling Equipment Summary Make York Make York Trade YORK BY JOHNSON CONTROLS Trade YORK Model TG9SO40A08MP11 Cond YCD18B21 AHRI ref 2008578 Coil CF24ABAA1 AHRI ref 201925857 Efficiency 95.5 AFUE Efficiency 12.3 EER, 14 SEER Heating input 40000 Btuh Sensible cooling 12110 Btuh Heating output 39000 Btuh Latent cooling 5190 Btuh Temperature rise 60 °F Total cooling 17300 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.016 cfm/Btuh Air flow factor 0.063 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.82 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -f - wrniglvtsoft 2018-Dec-06 16:13:03 Right-Suite4 Universal 2018 18.0.31 RSU23464 Page 3 /'---N ...NY\CliffHollow_12.6.18\CliffHollow_12.6.18.iup Calc=MJ8 Front Door faces: N r Load Short Form Job: 18128 , .0 Date: Dec 06,2018 Entire House By: A Dole Riverside Energy Consulting 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyConsulting@gmail.com Project Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Design Information Htg CIg Infiltration Outside db (°F) -4 85 Method Simplified Inside db(°F) 71 75 Construction quality Loose Design TD(°F) 74 10 Fireplaces 0 Daily range - M Inside humidity(%) 40 50 Moisture difference(gr./lb) 43 27 HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a AHRI ref n/a Coil n/a AHRI ref n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 0 cfm Actual air flow 0 cfm Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load CIg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Unit 1 d 2099 47600 17269 967 967 Unit2 d 1521 36519 9511 600 600 Entire House d 3620 84119 26779 1567 1567 Other equip loads 0 0 Equip. @ 1.00 RSM 26779 Latent cooling 4515 TOTALS I 3620 I 84119 I 31294 I 1567 I 1567 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wr�gt�tspft 2018-Dec-06 16:13:03 Right-Suite®Universal 2018 18.0.31 RSU23464 Page 1 - ...NY\CliffHollow_12.6.18\CliffHollow_12.6.18.rup Calc=MJ8 Front Door faces: N T , Load Short Form Job: 18126 ' Cill) Date: Dec 06,2018 Unit 1 By: A Dole Riverside Energy Consulting 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyConsulting@gmail.com Project Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Design Information Htg Clg Infiltration Outside db (°F) -4 85 Method Simplified Inside db(°F) 70 75 Construction quality Loose Design TD (°F) 74 10 Fireplaces 0 Daily range - M Inside humidity(%) 50 50 Moisture difference (gr/Ib) 52 27 HEATING EQUIPMENT COOLING EQUIPMENT Make York Make York Trade YORK BY JOHNSON CONTROLS Trade YORK Model TG9S060B12MP11 Cand YCD30B21 AHRI ref 2008579 Coil CF/CM/CU3OB AHRI ref 201926167 Efficiency 95.5 AFUE Efficiency 11.5 EER, 13.3 SEER Heating input 60000 Btuh Sensible cooling 20300 Btuh Heating output 58000 Btuh Latent cooling 8700 Btuh Temperature rise 55 °F Total cooling 29000 Btuh Actual air flow 967 cfm Actual air flow 967 cfm Air flow factor 0.020 cfm/Btuh Air flow factor 0.056 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Audio 132 4383 902 89 51 Great Room 380 23672 11260 481 631 Entry 88 1605 384 33 21 Bed 2 200 3696 890 75 50 Bed 1 Bath 81 1897 441 39 25 Bed 3 240 3658 514 74 29 Bed 3 Bath 63 372 8 8 0 Recreation 915 8319 2870 169 161 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wr�9htsuft 2018-Dec-0616:13:03 ��'`�' � Right-Su iteeUniversal 2018 18.0.31 RSU23464 Page 2 /ivU". ...NY\CliffHollow_12.6.18\CliffHollow_12.6.18.rup Calc=MJ8 Front Door faces: N Unit 1 d 2099 47600 17269 967 967 Other equip loads 0 0 Equip. @ 1.00 RSM 17269 Latent cooling 2367 TOTALS I 2099 I 47600 I 19636 I 967 I 967 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 41- w r ightsoft 2018-Dec-06 16:13:03 Right-Suite®U niversal 2018 18.0.31 RSU23464 Page 3 ..NY\CliffHollow_12.6.18\CliffHollow_12.6.18.rup Calc=MJ8 Front Door faces: N r - Load Short Form0 Job: 18126 Date: Dec 06,2018 Unit 2 By: A Dole Riverside Energy Consulting 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyConsultingtgmail.com Project Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Design Information Htg Clg Infiltration Outside db (°F) -4 85 Method Simplified Inside db(°F) 72 75 Construction quality Loose Design TD (°F) 76 10 Fireplaces 0 Daily range - M Inside humidity(%) 30 50 Moisture difference(gr/lb) 32 27 HEATING EQUIPMENT COOLING EQUIPMENT Make York Make York Trade YORK BY JOHNSON CONTROLS Trade YORK Model TG9SO40A08MP11 Cond YCD18B21 AHRI ref 2008578 Coil CF24ABAA1 AHRI ref 201925857 Efficiency 95.5 AFUE Efficiency 12.3 EER, 14 SEER Heating input 40000 Btuh Sensible cooling 12110 Btuh Heating output 39000 Btuh Latent cooling 5190 Btuh Temperature rise 60 °F Total cooling 17300 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.016 cfm/Btuh Air flow factor 0.063 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.82 1 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) Kitchen 560 6107 3522 100 222 Hall 87 540 110 9 7 Laundry 60 4790 514 79 32 1/2 Bath 42 1961 189 32 12 Mud 98 1640 266 27 17 Gallery 90 5746 1213 94 77 Master Bed 288 7068 1920 116 121 Master Bath 130 3749 854 62 54 Master WIC 166 4917 921 81 58 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2018-Dec-06 16:13:03 -+ wrightsoft Right-Suite®Universal201818.0.31 RSU23464 Page4 ...NY\CIiffHollow_12.6.18\CliffHollow_12.6.18.rup Calc=MJ8 Front Door faces: N Unit2 d 1521 36519 9511 600 600 Other equip loads 0 0 Equip. @ 1.00 RSM 9511 Latent cooling 2147 TOTALS I 1521 I 36519 I 11658 I 600 I 600 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrightsoft- 2018-Dec-06 16:13:03 Right-Suite®Universal 2018 18.0.31 RSU23464 Pages ,; ...NY1CIiffHollow_12.6.18\CliffHollow 12.6.18.rup Calc=MJB Front Door faces: N , ♦ BuildingAnalysis Job: 18126 ' 0 Y Date: Dec 06,2018 Entire House By: A Dole Riverside Energy Consulting 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyConsulting©gmail.com Pro'ect Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Desi•n Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 71 75 Elevation: 335 ft Design TD(°F) 74 10 Latitude: 43°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 42.7 26.5 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified V et bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btu h/ft2 Btuh %of load Walls 5.1 18313 21.8 Cods 29.2 18770 22.3 WiIs Doors 10.3 216 0.3 Ceilings 3.8 7355 8.7 Infilt►aation Floors 3.4 7882 9.4 Infiltration 8.1 29811 35.4 Ducts 1770 2.1 Piping 0 0 . Humidification 0 0 Gang Ventilation 0 0 Adjustments 0 0(. & Floors Total 84119 100.0 nags Coolin• Component Btu h/ft2 Btuh %of load Walls 0.7 2649 9.9 Glazing 20.5 13192 49.3 Wes Irt8rn3l Cans Doors 2.9 61 0.2 Ceilings 2.3 4383 16.4 Irfiltraticn Floors 0.1 264 1.0 Infiltration 0.6 2082 7.8 7Ducts 229 0.9 Ventilation 0 0 Ceilirgs Internal gains 3920 14.6 Gazirg Blower 0 0 Caw Adjustments 0 Total 26779 100.0 Latent Cooling Load =4515 Btuh Overall U-value=0.085 Btuh/ft2-°F Data entries checked. w r ightsoit 2018-Dec-06 16:13:03 :� Right-Suite®Universal 2018 18.0.31 RSU23464 Page 1 ACC' ...NY\CIiffHollow_12.6.181Cli fHoliow_12.6.18.rup Calc=MJ8 Front Door faces: N BuildingAnalysis Job: 18126 y Date: Dec 06,2018 , ,0 Unit 1 By: A Dole Riverside Energy Consulting 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyConsulting©gmail.com Pro'ect Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Desi• n Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 75 Elevation: 335 ft Design TD (°F) 74 10 Latitude: 43°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btu h/ft2 Btuh_ %of load Walls 5.6 11322 23.8 Glazing 31.6 12940 27.2 V�IIs Doors 10.3 216 0.5 / Infiltration Ceilings 5.7 5455 11.5 Floors 1.9 2426 5.1 Infiltration 8.0 15242 32.0 Ducts 0 0 Piping 0 0 Humidification 0 0 'Roas Ventilation 0 0 Glaang Adjustments 0 Ceilings Total 47600 100.0 Cther Coolin• Component Btu hilt' Btuh- %of load_ Walls 0.9 1892 11.0 Glazing 20.5 8413 48.7 / Is hard Gins Doors 2.9 61 0.4 Ceilings 3.4 3273 19.0 Irlfiltraticn Floors 0.0 62 0.4 Infiltration 0.6 1078 6.2 Ducts 0 0 Ventilation 0 0 f CHlir� Internal gains 2490 14.4 erg Blower 0 0 aher Adjustments 0 Total 17269 100.0 Latent Cooling Load =2367 Btuh Overall U-value=0.096 Btuh/ft2-°F Data entries checked. - , wrightsoft 2018-Dec-06 16:13:03 ,t Right-Suitee Universal 2018 18.0.31 RSU23464 Page 2 ACC ...NY1CliffHollow_12.6.181CIiffHollow_12.6.18.rup Calc=MJ8 Front Door faces: N Building• Analysis Job: 1e fps Date: Dec 06,2018 Unit 2 By: A Dole Riverside Energy Consulting 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax 747-517-6129 Email:RiversideEnergyConsulting©gmail.com Pro'ect Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Desi• n Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 72 75 Elevation: 335 ft Design TD(°F) 76 10 Latitude: 43°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 31.7 26.5 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 0 Heatin• Component Btu h/ft2 Btuh %of load Walls 4.5 6991 19.1 Ducts Glazing 25.1 5830 16.0 Wills Doors 0 0 0 Ceilings 2.0 1901 5.2 Floors 5.4 5457 14.9 Infiltration 8.2 14570 39.9 ____Infiltration Ducts 1770 4.8 Gaang___ Piping 0 0 Humidification 0 0 Ventilation 0 0 03ilings Adjustments 0 Room Total 36519 100.0 Coolin• Component Btuh/ft2 Btuh %of load Walls 0.5 757 8.0 Glazing 20.5 4779 50.2 vllls Irten d Gans Doors 0 0 0 Duds Ceilings 1.1 1110 11.7 Floors 0.2 202 2.1 _irfittlaticn Infiltration 0.6 1003 10.6 Ducts 229 2.4 Ventilation 0 0 Ficas Internal gains 1430 15.0 Gaing Blower 0 0 c itr>g; Adjustments 0 Total 9511 100.0 Latent Cooling Load =2147 Btuh Overall U-value=0.072 Btuh/ft2-°F Data entries checked. ,,,,..1_ 9 wrightsoit 2018-Dec-0616:13:03 Right-Suite®Universal 2018 18.0.31 RSU23464 Page 3 A ...NY\Clif Hollow_12.6.18\CliftHollow_12.6.18.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 18126 Date: Dec 06,2018 Entire House By: A Dole ..., Riverside Energy Consulting 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyConsulting@gmail.com Pro'ect Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 71 75 Elevation: 335 ft Design TD(°F) 74 10 Latitude: 43°N Relative humidity(%) 40 50 Outdoor: Heating Cooling Moisture difference(grub) 42.7 26.5 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified V1kt bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Cig HTM Gain fP Btuhm'-°F fl'-°FlBtuh Btuh/R' Btuh Btuhflt' Btuh Walls 12B-Osw:Frm wall,vnl ext,r-11 cav ins, 1/2"gypsum board int fnsh, n 376 0.097 11.0 7.17 2693 1.15 433 2"x4"wood frm, 16"o.c.stud e 223 0.097 11.0 7.13 1590 1.15 257 s 102 0.097 11.0 7.13 724 1.15 117 w 200 0.097 11.0 7.29 1459 1.15 231 all 900 0.097 11.0 7.18 6466 1.15 1038 12C-Osw:Frm wall,vnl ext,3/8"wood shth,r-13 cav ins,1/2"gypsum n 2 0.091 13.0 6.69 13 0.90 2 board int fnsh,2"x4"wood frm,16"o.c.stud e 171 0.091 13.0 6.69 1140 0.90 153 s 50 0.091 13.0 6.69 334 0.90 45 w 1 0.091 13.0 6.69 5 0.90 1 all 223 0.091 13.0 6.69 1493 0.90 200 12E-5sw:Frm wall,vnl ext,3/8"wood shth,r-19 cav ins,1/2"gypsum n 253 0.052 24.0 3.93 993 0.35 89 board int fnsh,r-5 ext bd ins,2"x6"wood frm, 16"o.c.stud e 263 0.052 24.0 3.93 1033 0.35 93 s 413 0.052 24.0 3.93 1621 0.35 146 w 228 0.052 24.0 3.93 894 0.35 81 nw 123 0.052 24.0 3.93 484 0.35 44 all 1280 0.052 24.0 3.93 5025 0.35 453 15B11-8wc-6:Bg wall,heavy damp soil,2"x4"wood int frm,concrete n 240 0.043 19.0 3.33 798 0.05 12 wall,r-15 ins,8"thk,1/2"gypsum board int fnsh e 242 0.043 19.0 3.26 787 0.03 7 w 152 0.043 19.0 3.33 506 0.05 7 all 634 0.043 19.0 3.30 2091 0.04 26 16B-13ad:Knee wall,asphalt shingles roof mat,r-13 kw ins, 1/2" n 120 0.070 13.0 5.14 617 3.09 370 gypsum board int fnsh w 24 0.070 13.0 5.14 123 3.09 74 all 144 0.070 13.0 5.14 741 3.09 445 12C-0sw:Frm wall,vnl ext,r-13 cav ins, 1/2"gypsum board int fnsh, e 27 0.091 13.0 6.87 188 0.90 24 2"x4"wood frm, 16"o.c.stud 12F-5sm:Frm wall,vnl ext,3/8"wood shth,r-21 cav ins, 1/2"gypsum e 32 0.070 26.0 5.14 165 0.43 14 board int fnsh,r-5 ext bd ins,2"x6"metal frm,16"o.c.stud s 64 0.070 26.0 5.14 329 0.43 27 w 32 0.070 26.0 5.14 165 0.43 14 all 128 0.070 26.0 5.14 659 0.43 55 12B-0sw:Frm wall,vnl ext,3/8"wood shth,r-11 cav ins,1/2"gypsum s 232 0.097 11.0 7.13 1651 1.77 409 board int fnsh,2"x4"wood frm, 16"o.c.stud Partitions (none) "�' ' wrightsoft 2018 Dec-06 16:13:03 Right-Suite®Universal 2018 18.0.31 RSU23464 Page 1 ACCta ...NY\CliffHollow_12.6.181CIiffHollow 12.6.18.rup Caic=MJ8 Front Door faces: N ' Windows Dbl Nonmetal Default 2012:2 glazing,clr outr,air gas,vnl frm mat,clr n 5 0.550 0 40.4 189 13.8 64 innr,1/4"gap,1/8"thk;50% blinds 45°,medium; 50% indoor insect n 72 0.550 0 40.6 2924 13.8 994 screen e 50 0.550 0 40.4 2021 53.8 2688 s 80 0.550 0 40.4 3250 27.3 2194 all 207 0.550 0 40.5 8384 28.7 5941 U32 S32:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, n 40 0.320 0 23.5 941 8.82 353 1/8"thk;50%indoor insect screen s 48 0.320 0 23.5 1129 16.7 799 nw 15 0.320 0 24.2 350 21.5 312 all 103 0.320 0 23.6 2420 14.3 1464 U32 S32:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, e 23 0.320 0 23.5 529 27.8 627 1/8"thk;50% blinds 45°,medium;50% indoor insect screen s 156 0.320 0 24.2 3769 14.3 2233 s 40 0.320 0 24.2 971 14.3 576 w 10 0.320 0 24.2 242 27.8 278 all 229 0.320 0 24.1 5511 16.2 3714 U32 S32:2 glazing,cir low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, s 24 0.320 0 23.5 564 7.43 178 1/8"thk;50% blinds 45°,medium;50% indoor insect screen;4 ft overhang(4 ft window ht,1.5 ft sep.) U32 S32:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, s 80 0.320 0 23.5 1891 7.43 597 1/8"thk;50% blinds 45°,medium;50% indoor insect screen;4 ft overhang(6.7 ft window ht,0.5 ft sep.) Doors ThermaTru Basic n 21 0.140 7.0 10.3 216 2.88 61 Ceilings 16B-21 ad:Attic ceiling,asphalt shingles roof mat,r-21 ceil ins,1/2" 714 0.044 21.0 3.26 2330 1.94 1385 gypsum board int fnsh 16B-50ad:Attic ceiling,asphalt shingles roof mat,r-50 cell ins,1/2" 733 0.020 50.0 1.51 1107 0.88 647 gypsum board int fnsh 16B-7ad:Attic ceiling,asphalt shingles roof mat,r-7 cell ins, 1/2" 476 0.112 7.0 8.23 3918 4.94 2351 gypsum board int fnsh Floors 19A-Obvhp:Fir floor,frm flr,8"thkns,hrd wd fir fnsh,leaky bsmt ovr 56 0.295 0 8.15 456 1.11 62 19A-30bswp:Fir floor,frm flr,10"thkns,hrd wd fir fnsh,r-30 cav ins, 664 0.034 30.0 2.15 1430 0.29 189 tight bsmt ovr 20P-30w:Fir floor,frm fir,10"thkns,hrd wd flr fnsh,r-30 cav ins,amb 88 0.035 30.0 2.64 233 0.14 13 ovr 21A-28w:Bg floor,heavy damp soil,6.5'depth,hrd wd flr fnsh 1218 0.022 0 1.62 1970 0 0 22A-wph:Bg floor,heavy damp soil,on grade depth,hrd wd flr fnsh 37 1.358 0 103 3794 0 0 wrightsoft 2018 Dec-06 16:13:03 Right-Suite® RSU23464 Page2 9 ACCA ..NY1CIiffHollow_12.6.181CIiffHollow_12.6.18.rup Calc=MJ8 Front Door faces: N , Component Constructions Job: 18128 . .0 Date: Dec 08,2078 Unit 2 By: A Dole Riverside Energy Consulting 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyConsulting@gmail.com Pro'ect Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature (°F) 72 75 Elevation: 335 ft Design TD(°F) 76 10 Latitude: 43°N Relative humidity(%) 30 50 Outdoor: Heating Cooling Moisture difference(gr/Ib) 31.7 26.5 Drybulb(°F) -4 85 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain tN Btuh/P-T fF-°FBtuh Btuh/ft' Btuh Btuh/IF Btuh Walls 12B-0sw:Frm wall,vnl ext,r-11 cav ins, 1/2"gypsum board int fnsh, n 79 0.097 11.0 7.32 579 1.15 91 2"x4"wood frm, 16"o.c.stud w 164 0.097 11.0 7.32 1200 1.15 189 all 243 0.097 11.0 7.32 1778 1.15 280 12E-5sw:Frm wall,vnl ext,3/8"wood shth,r-19 cav ins,1/2"gypsum n 253 0.052 24.0 3.93 993 0.35 89 board int fnsh,r-5 ext bd ins,2"x6"wood frm, 16"o.c.stud e 263 0.052 24.0 3.93 1033 0.35 93 s 413 0.052 24.0 3.93 1621 0.35 146 w 228 0.052 24.0 3.93 894 0.35 81 nw 123 0.052 24.0 3.93 484 0.35 44 all 1280 0.052 24.0 3.93 5025 0.35 453 12C-0sw:Frm wall,vnl ext,r-13 cav ins, 1/2"gypsum board int fnsh, e 27 0.091 13.0 6.87 188 0.90 24 2"x4"wood frm, 16"o.c.stud Partitions (none) Windows Dbl Nonmetal Default 2012:2 glazing,clr outr,air gas,vnl frm mat,clr n 12 0.550 0 41.5 498 13.8 166 innr,1/4"gap,1/8"thk; 50%blinds 45°,medium; 50% indoor insect screen U32 S32:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, nw 15 0.320 0 24.2 350 21.5 312 1/8"thk;50%indoor insect screen U32 S32:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, s 156 0.320 0 24.2 3769 14.3 2233 1/8"thk;50% blinds 45°,medium;50% indoor insect screen s 40 0.320 0 24.2 971 14.3 576 w 10 0.320 0 24.2 242 27.8 278 all 206 0.320 0 24.2 4982 15.0 3087 Doors (none) Ceilings 16B-21 ad:Attic ceiling,asphalt shingles roof mat,r-21 cell ins,1/2" 239 0.044 21.0 3.32 794 1.94 464 gypsum board int fnsh 16B-50ad:Attic ceiling,asphalt shingles roof mat,r-50 ceil ins,1/2" 733 0.020 50.0 1.51 1107 0.88 647 gypsum board int fnsh wrightsoft 2018-Dec 08 16:13:03 ;+ Right-Su Re®U niv ersal 2018 18.0.31 RSU23464 Page 3 ACCt1 ...NY1CIiffHollow_12.6.18\CliffHollow_12.6.18.rup Calc=MJ8 Front Door faces: N Component Constructions Job: 18126 ��� p Date: Dec 06,2018 Unit 1 By: A Dole ' Riverside Energy Consulting 1144 Main St,Brockton,MA 02301 Phone:508-400-4186 Fax:747-517-6129 Email:RiversideEnergyConsultingcgmail.com Pro-ect Information For: FW Webb Company 1 Mccrea Hill Blvd, Ballston Spa, NY 12020 Phone: 518-490-7500 Fax: 518-490-7555 Design Conditions Location: Indoor: Heating Cooling Glens Falls AP, NY, US Indoor temperature(°F) 70 75 Elevation: 335 ft Design TD(°F) 74 10 Latitude: 43°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 51.7 26.5 Dry bulb(°F) -4 85 Infiltration: Daily range(°F) - 22 ( M ) Method Simplified Wet bulb(°F) - 71 Construction quality Loose Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss Clg HTM Gain ft' Btuh/R'--°F fF-°F/BWh Btuhtft' Btuh Btuh/ft' Btuh Walls 12B-Osw:Frm wall,vnl ext,r-11 cav ins, 1/2"gypsum board int fnsh, n 297 0.097 11.0 7.13 2114 1.15 342 2"x4"wood frm, 16"o.c.stud e 223 0.097 11.0 7.13 1590 1.15 257 s 102 0.097 11.0 7.13 724 1.15 117 w 36 0.097 11.0 7.13 260 1.15 42 all 658 0.097 11.0 7.13 4688 1.15 758 12C-0sw:Frm wall,vnl ext,3/8"wood shth,r-13 cav ins, 1/2"gypsum n 2 0.091 13.0 6.69 13 0.90 2 board int fnsh,2"x4"wood frm,16"o.c.stud e 171 0.091 13.0 6.69 1140 0.90 153 s 50 0.091 13.0 6.69 334 0.90 45 w 1 0.091 13.0 6.69 5 0.90 1 all 223 0.091 13.0 6.69 1493 0.90 200 15B11-8wc-6:Bg wall,heavy damp soil,2"x4"wood int frm,concrete n 240 0.043 19.0 3.33 798 0.05 12 wall,r-15 ins,8"thk, 1/2"gypsum board int fnsh e 242 0.043 19.0 3.26 787 0.03 7 w 152 0.043 19.0 3.33 506 0.05 7 all 634 0.043 19.0 3.30 2091 0.04 26 16B-13ad:Knee wall,asphalt shingles roof mat,r-13 kw ins,1/2" n 120 0.070 13.0 5.14 617 3.09 370 gypsum board int fnsh w 24 0.070 13.0 5.14 123 3.09 74 all 144 0.070 13.0 5.14 741 3.09 445 12F-5sm:Frm wall,vnl ext,3/8"wood shth,r-21 cav ins, 1/2"gypsum e 32 0.070 26.0 5.14 165 0.43 14 board int fnsh,r-5 ext bd ins,2"x6"metal frm,16"o.c.stud s 64 0.070 26.0 5.14 329 0.43 27 w 32 0.070 26.0 5.14 165 0.43 14 all 128 0.070 26.0 5.14 659 0.43 55 12B-0sw:Frm wall,vnl ext,318"wood shth,r-11 cav ins,1/2"gypsum s 232 0.097 11.0 7.13 1651 1.77 409 board int fnsh,2"x4"wood frm, 16"o.c.stud Partitions (none) Windows Dbl Nonmetal Default 2012:2 glazing,clr outr,air gas,vnl frm mat,clr n 5 0.550 0 40.4 189 13.8 64 innr, 1/4"gap,1/8"thk; 50% blinds 45°,medium; 50% indoor insect n 60 0.550 0 40.4 2426 13.8 828 screen e 50 0.550 0 40.4 2021 53.8 2688 s 80 0.550 0 40.4 3250 27.3 2194 all 195 0.550 0 40.4 7886 29.6 5775 w rightsoft 2018-Dec o6 16:13:03 Right-Suite®Universal 2018 18.0.31 RSU23464 Page 5 AOCt O ...NY\CliffHollow_12.6.18\CliffHollow_12.6.18.rup Calc=MJ8 Front Door faces: N .- U32 S32:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, n 40 0.320 0 23.5 941 8.82 353 • l/8"flak;50%indoor insect screen s 48 0.320 0 23.5 1129 16.7 799 all 88 0.320 0 23.5 2070 13.1 1152 U32 S32:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, e 23 0.320 0 23.5 529 27.8 627 1/8"thk;50% blinds 45°,medium;50% indoor insect screen U32 S32:2 glazing,clr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, s 24 0.320 0 23.5 564 7.43 178 1/8"thk;50% blinds 45°,medium;50% indoor insect screen;4 ft overhang(4 ft window ht, 1.5 ft sep.) U32 S32:2 glazing,dr low-e outr,air gas,vnl frm mat,clr innr, 1/4"gap, s 80 0.320 0 23.5 1891 7.43 597 1/8"thk;50%blinds 45°,medium;50% indoor insect screen;4 ft overhang(6.7 ft window ht,0.5 ft sep.) Doors ThermaTru Basic n 21 0.140 7.0 10.3 216 2.88 61 Ceilings 16B-21 ad:Attic ceiling,asphalt shingles roof mat,r-21 cell ins, 1/2" 475 0.044 21.0 3.23 1536 1.94 922 gypsum board int fnsh 16B-7ad:Attic ceiling,asphalt shingles roof mat,r-7 ceil ins,1/2" 476 0.112 7.0 8.23 3918 4.94 2351 gypsum board int fnsh Floors 19A-0bvhp:Fir floor,frm fir,8"thkns,hrd wd fir fnsh,leaky bsmt ovr 56 0.295 0 8.15 456 1.11 62 21A-28w:Bg floor,heavy damp soil,6.5'depth,hrd wd fir fnsh 1218 0.022 0 1.62 1970 0 0 wrightsoft 2018-Dec-06 16:13:03 Right-Suite®Universal 2018 18.0.31 RSU23464 Page 6 ACC. ...NY\CliffHollow_12.6.18\CliffHollow_12.6.18.rup Calc=MJ8 Front Door faces: N Basement Bed3 Bed 3 Bath Recreann.: Mechanical Jab#: 18126 Riverside Energy Consulting Scale: 1 : 150 Performed by A Dole for: Page 1 FW Webb Company 1144 Main St Right-Suite®Universal 2018 t Mccrea Hill Blvd Brockton,MA 02301 18.0.31 RSU23464 Ballston Spa,NY 12020 Phone:508-400-4186 Fax:747-517-6129 2018-Dec-06 16:14:12 Phone:518-490-7500 Fax:516-490-7555 RiversideEnergyConsulting@gmail.com ..._12.6.18\CliffHollow_12.6.18.rup 1st Floor Master Bath II Master Bed Ueliery -. Master WIC Kitchen Great Room Mud Hail 1!2 th Bed 2 Laundry Audio Entry 71 Bed 1 Bath Job#: 18126 Riverside Energy Consulting Scale: 1 : 150 Performed by A Dole for: Page 2 FW Webb Company 1144 Main St Right-Suite®Universal 2018 1 Mccrea Hill Blvd Brockton,MA 02301 18.0.31 RSU23464 Ballston Spa,NY 12020 Phone:508-400-4186 Fax:747-517-6129 2018-Dec-06 16:14:12 Phone.518-490-7500 Fax:518-490-7555 RiversideEnergyConsulting@gmail.com _12.6.18\CliffHollow_12.6.18.rup cjREScheck Software Version 4.6.5 Compliance Certificate lECEOWERI Project Kelly Residence :Di! FIC 112018Energy Code: 2015 IECC _ �--- Location: Lake George, New York I OWN O OUEENSBURY COCFS Construction Type: Single-family BUIL �` .. Project Type: Alteration Climate Zone: 6 (7377 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 17 Cliff Hollow Road Sara Kelly Curtis Dybas Queensbury, NY 12804 30 Oakwood Drive 19 Deer Run Queensbury, NY 12804 Lake George, NY 12845 518 789 2107 518 668 5591 kelly.sara@gmail.com cdybas@yahoo.com Compliance: Passes using prescriptive requirements for alteration projects Envelope Assemblies AssemblyGross Area Cavity Cont. or R-Value R-Value U-Factor UA Perimeter Ceiling 1: Flat Ceiling or Scissor Truss --- --- --- --- Exemption: Framing cavity filled with insulation Ceiling 2: Cathedral Ceiling --- --- --- --- --- Exemption: Framing cavity not exposed. Wall 1: Wood Frame, 16" o.c. --- _- --- --- --- Exemption: Framing cavity filled with insulation Window 1: Wood Frame:Double Pane with Low-E 220 0.290 64 Window 2:Wood Frame:Double Pane with Low-E 160 0.320 51 Door 1: Solid 40 0.077 3 Basement Wall 1: Solid Concrete or Masonry --- --- --- --- Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Exemption: Framing cavity filled with insulation Basement Wall 2: Solid Concrete or Masonry --- --- --- --- Wall height: 4.0' Depth below grade: 3.5' Insulation depth: 4.0' Exemption: Framing cavity not exposed. 239.18-1-32 RC-0783-2018 Kelly, Sara 17 Cliff Hollow Rd Res. Additions &Alt. 5333 s.f. Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Alteration.rck Page 1 of10 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirn.,,,zal ments listeditthe Scheck Inspection Checklist./ / Gvt2fK 0. tT , r� .[J. 12 if 8 Name-Title Signature Date OD ARC ark', •.015O. O 'Si • J B FrJ m • .' ` o d o,'NE ST Alt c) Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Alteration.rck Page 2 of10 rREScheck Software Version 4.6.5 , Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Pre-Inspection/Plan Review Plans Value fied Field luefied Complies? Comments/Assumptions Ed Req.ID ( 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate DDoes Not [PR1]i energy code compliance for the building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction d ocuments, 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]' lighting and mechanical systems. :Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. '302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods ❑Not Observable approved by the code official. Btu/hr Btu/hr ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 !Low Impact(Tier 3) Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Alteration.rck Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection value Value Complies? Comments/Assumptions &Req.ID _ j 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R_ R- ❑Does Not table for values. Vo insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO5]i insulation installed per ❑Does Not manufacturer's instructions. :Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [FO6]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. }„ [Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. :Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not co :Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 21Medium Impact(Tier 2) 1 3 Low Impact(Tier 3) I Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Alteration.rck Page 4 of10 Section Plans Verified Field Verified # Framing /Rough-In Inspection Value Value Complies? Comments/Assumptions &Re..ID _ ! �__— -- 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies — 402.3.4 ❑Does Not table for values. [FR1]1 :Not Observable ONot Applicable 402.1.1,— Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 ONot Observable [FR2]1 ONot Applicable 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ONot Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not lie instructions. :Not Observable ONot Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR20J1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 or has infiltration rates per NFRC ONot Observable 400 that do not exceed code ONot Applicable limits. 402.4.5 IC-rated recessed lighting fixtures OComplies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate 52.0 cfm ❑Not Observable leakage at 75 Pa. ONot Applicable 403.3.1 Supply and return ducts in attics ❑Complies [FR141 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and ONot Observable return ducts in other portions of DNot Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.5 Building cavities are not used as ❑Com lies [FR15]3 ducts or plenums. ❑Does Not :Not Observable [Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Com lies [FR17]2 above 105 QF or chilled fluids ❑Does Not below 55 QF are insulated to zR- ONot Observable 3. ONot Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ONot Observable ONot Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ONot Observable [Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19J2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable [Not Applicable i j 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Alteration.rck Page 5 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? i Comments/Assumptions & Req.ID 1 303.1 All installed insulation is labeled ❑Complies I[IN13)2 or the installed R-values ❑Does Not provided. [Not Observable __ _ ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- EComplies See the Envelope Assemblies 402.2.5, mass wall with at least'/z of the 0 Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ONot Observable (IN3]i exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 ;High Impact(Tier 1) 12 !Medium Impact(Tier 2) 3 )Low Impact(Tier 3) j Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Alteration.rck Page 7 of10 • Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- EComplies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, 402.2.E ❑ Steel ❑ Steel :Not Observable [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [FI22]2 insulation include baffle adjacent ODoes Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- P: ❑Complies (F13]1 insulation >_R-value of the ❑Does Not adjacent assembly. :Not Observable _--_ _--- ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = EComplies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Nat Observable ❑Not Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 _cfm/100 ❑Complies [Fl4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa. For rough-in tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch [Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI24]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ElComplies [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. Not Applicable 403.1.2 Heat pump thermostat installed EComplies [FI10]2 on heat pumps. ❑Does Not :Not Observable ❑Not Applicable 403.5.1 Circulating service hot water EComplies [FI11)2 systems have automatic or ❑Does Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 I High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Alteration.rck Page 8 of10 • Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy [Not Observable and air flow limits. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water :Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the ❑Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1044F. 403.5.4 Drain water heat recovery units ❑Complies [F131]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ['Not Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies (F16]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 TMedium Impact(Tier 2) 13 Low Impact(Tier 3) Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Alteration.rck Page 9 of10 Section Plans Verified 1 Field Verified # Final Inspection Provisions value Value Complies? Comments/Assumptions & Req.ID 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not ONot Observable __-_____-.-------- . ❑Not Applicable �._ 303.3 Manufacturer manuals for �EComplies r_�___ [F118]3 mechanical and water heating ❑Does Not systems have been provided. :Not Observable __..._._._._.___�.____. Not Applicable Additional Comments/Assumptions: (1 High Impact(Tier 1) 12 'Medium Impact(Tier 2) 3 ;Low Impact(Tier 3) 1 Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Alteration.rck Page 10 of10 . s i cl 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 0.00 Below-Grade Wall 0.00 Floor 0.00 Ceiling / Roof 0.00 Ductwork (unconditioned spaces): Glass& Door Rating U-Factor SHGC Window 0.29 Door 0.08 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments REScheck Software Version 4.6.5 N/Th Compliance Certificate- : . - — __ t\'‘ ,}.c. 1 1 2018 d Project Kelly Residence �'�- Energy Code: 2015 IECC 1O\NI'~ rp''' r ^.3 Location: Lake George, New York BUI; - ''- _,--- --- Construction Construction Type: Single-family Project Type: Addition Climate Zone: 6 (7377 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 17 Cliff Hollow Road Sara Kelly Curtis Dybas Queensbury, NY 12804 30 Oakwood Drive 19 Deer Run Queensbury, NY 12804 Lake George, NY 12845 518 789 2107 518 668 5591 kelly.sara@gmail.com cdybas@yahoo.com Compliance: Passes using UA trade-off Compliance: 6.7%Better Than Code Maximum UA: 194 Your UA: 181 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Perimeter R-Value R-Value Ceiling 1: Flat Ceiling or Scissor Truss 445 38.0 0.0 0.030 13 Ceiling 2: Cathedral Ceiling 315 38.0 0.0 0.027 9 Wall 1: Wood Frame, 16" o.c. 1,482 21.0 5.0 0.043 52 Window 1: Wood Frame:Double Pane with Low-E 88 0.270 24 Window 2: Wood Frame:Double Pane with Low-E 99 0.290 29 Window 3:Wood Frame:Double Pane with Low-E 53 0.320 17 Door 1: Solid 42 0.077 3 Basement Wall 1: Solid Concrete or Masonry 408 21.0 0.0 0.046 19 Wall height: 8.0' Depth below grade: 6.0' Insulation depth: 8.0' Basement Wall 2: Solid Concrete or Masonry 208 0.0 10.0 0.070 15 Wall height: 4.0' Depth below grade: 3.5' Insulation depth: 4.0' 239.18-1-32 RC-0783-2018 Kelly, Sara 17 Cliff Hollow Rd Res. Additions &Alt. 5333 s.f. Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Residence.rck Page 1 of10 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. e.vrre., 0. art5i.i.s 1 ael Clita,S0 c4COCA.6 r�/o3Its Name-Title Signature Date RED A S C, IU • 0) • j Y T 7 sc �r*/. IOC t% C. ,F �E'kE STASE Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Residence.rck Page 2 of10 c- i REScheck Software Version 4.6.5 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified 7 # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the building envelope.Thermal :Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods Btu/hr Btu/hr ❑Not Observable approved by the code official. ❑Not Applicable ._____ Additional Comments/Assumptions: _ a i 'High Impact(Tier 1) 1 2 Medium Impact(Tier 2) 3 iLow Impact(Tier 3) 1 Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Residence.rck Page 3 of10 • Section f Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID __ _ 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R. R- ❑Does Not table for values. insulation is used, verification ❑Not Observable may need to occur during Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO5)1 insulation installed per ❑Does Not manufacturer's instructions. ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies - - [FO6]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed ❑Complies [FOil]z to protect exposed exterior ❑Does Not insulation and extends a ❑Not Observable minimum of 6 in. below grade. ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [FO122 controls installed. ❑Does Not :Not Observable ONot Applicable J Additional Comments/Assumptions: High Impact(Tier 1) 2 ?Medium Impact(Tier 2) 1 3 TLLow Impact(Tier 3) 1 Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Residence.rck Page 4 of10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID _ i 402.1.1, Door U-factor. U- - U- OComplies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable __._.______-��_____________ _.__._ _. ONot Applicable 402.1.1, Glazing U-factor(area-weighted U- U- _ OComplies See the Envelope.Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 ONot Observable [FR2]1 ONot Applicable 303.1.3 U-factors of fenestration products OComplies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or :Not Observable taken from the default table. ONot Applicable 402.4.1.1 Air barrier and thermal barrier OComplies [FR23]1 installed per manufacturer's ❑Does Not instructions. ENot Observable :Not Applicable 402.4.3 Fenestration that is not site built OComplies [FR2O]1 is listed and labeled as meeting ❑Does Not 44 AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ONot Applicable limits. 402.4.5 IC-rated recessed lighting fixtures OComplies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate 52.0 cfm leakage at 75 Pa. ❑Not Observable ONot Applicable 403.3.1 Supply and return ducts in attics OComplies [FR12J1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where< 3 inches. Supply and ONot Observable return ducts in other portions of ONot Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.5 Building cavities are not used as OComplies [FR1533 ducts or plenums. ❑Does Not ' ONot Observable ONot Applicable 403.4 HVAC piping conveying fluids R- R- OComplies [FR17]2 above 105 QF or chilled fluids ❑Does Not below 55 QF are insulated to>_R- 3 ONot Observable ONot Applicable 403.4.1 Protection of insulation on HVAC OComplies [FR24]1 piping. ❑Does Not ONot Observable ONot Applicable 403.5.3 Hot water pipes are insulated to R- R- _ OComplies [FR18]2 >_R-3. ❑Does Not ❑Not Observable ONot Applicable 403.6 Automatic or gravity dampers are OComplies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ONot Observable ONot Applicable 1;High Impact(Tier 1) 12 1 Medium Impact(Tier 2) I 3 j Low Impact(Tier 3) i Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Residence.rck Page 5 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not A, provided. :Not Observable — --- -- — ❑Not Applicable 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least%of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]i exterior,the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4P manufacturer's instructions. ❑Does Not 1 L ..._ :Not Observable ❑Not Applicable Additional Comments/Assumptions: -1 LHigh Impact(Tier 1) _1 2 'i Medium Impact(Tier 2) T3 Low Impact(Tier 3) Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Residence.rck Page 7 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.lD 402.1.1, Ceiling insulation R-value. R- R- DComplies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values, 402.2.2, 402.2.E 0 Steel ❑ Steel [Not Observable [FI1]1 ONot Applicable 303.1.1.1, Ceiling insulation installed per OComplies 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every 300 ft2. ONot Observable -- ONot Applicable 402.2.3 Vented attics with air permeable OComplies [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ONot Observable ONot Applicable 402.2.4 Attic access hatch and door R- R- OComplies [FI3]1 insulation >_R-value of the ❑Does Not adjacent assembly. :Not Observable :Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = OComplies [FI17]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable i ONot Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 OComplies [FI4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air I handler @ 25 Pa. For rough-in :Not Observable tests,verification may need to :Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 _cfm/100 ❑Complies [F127]1 determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ONot Observable pressure differential of 0.1 inch ONot Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test.Postconstruction test:Total 1 leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI24]1 by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ONot Applicable 403.1.1 Programmable thermostats OComplies [FI9)2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to :Not Observable code specifications. ONot Applicable 403.1.2 Heat pump thermostat installed OComplies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ONot Applicable 403.5.1 Circulating service hot water OComplies [FI11]2 systems have automatic or ❑Does Not accessible manual controls. [Not Observable ONot Applicable 1 High Impact(Tier 1) 1 2 IMedium Impact(Tier 2) L 3 ;Low Impact(Tier 3) Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Residence.rck Page 8 of10 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies [FI25]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy :Not Observable and air flow limits. ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply Not Observable pipe. Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the [Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130)2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104QF. 403.5.4 Drain water heat recovery units ❑Complies [F131)2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat Not Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI6]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have DComplies [FI23]3 no continuous pilot light. ❑Does Not ENot Observable [Not Applicable 1 High Impact(Tier 1) 12 'Medium Impact(Tier 2) 3 (Low Impact(Tier 3) Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Residence.rck Page 9 of10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID, _ 401.3 Compliance certificate posted. ❑Complies [FI7]2 ❑Does Not :Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 1 High Impact(Tier 1) FiTMedium Impact(Tier 2) 13_Low Impact(Tier 3) Project Title: Kelly Residence Report date: 12/02/18 Data filename: C:\Users\Curtis\Documents\REScheck\Kelly Residence.rck Page 10 of10 • r i CI 20 IE Efficie15ncyCC Energy Certificate Insulation Rating R-Value Above-Grade Wall 26.00 Below-Grade Wall 21.00 Floor 0.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.29 Door 0.08 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments NATURAL LIGHT,VENTILATION&EMERGENCY EGRESS CALCULATION SHEET Project Location: t j cl.rfr 1-Lou-a sZiso Primary Owner (s): 5AgiN a. 461.4)( (CALCAA4tor lg 13--. G. 1.21' ) Habitable Sq. Ft. Required Actual Required Actual Sq. ft. Rooms of Light Light Ventilation Ventilation opening Room (8% of rm.) (sq. ft.) (4% of room) (sq. ft.) for Egress t2 .lz 1 &((3 53 l3 2- 27 35 21.3 6torzlf-1 16,0 15.4 I7.67 6 .7 1g.& 7..5x2= ( '9t -793 �ln 21 ��A 1 ( 3-)..8 - -177 (92 !o& 31 57.i 3'7, S lob 84 1'7. (9 4,2 10.C9 7.4 x 2= I� ti 15(# 12• 17.( & .3 (S .& 7.cx2: Ic /42 M.+ 45 .1 1 .7 r1 .7 ;.")x3= i7. t P, `v1 201 1(9 . 1 21.0 6.0 I6',0 6)(2: 12 2 FL r ' Priil pie StgURIre k0Sz Mac Ai kl; ,p e s rutture Revised March 2018 169 Haviland Road Queensbury, NY 12804 Hutchins Engineering Phone:(518)745-0307 Fax: (518)745-0308 December 11, 2018 '1 Mr. Craig Brown Town of Queensbury Planning and Zoning DEC 1 1 2018 742 Bay Road Queensbury, NY 12804 TOWN OF QUEENSBURY PLANNING OFFICE Reference: 17 Cliff Hollow, Septic System Certification Parcel ID No. 239.18-1-32 Kelly Residence Zait Dear Mr. Brown: I have reviewed available documentation describing the installation of the septic system at the referenced property. This documentation includes the following: • A plan drawing entitled Map of the Lands of William E. and Kathleen Doetzer prepared by Coulter and McCormack Land Surveyors dated February 1, 1983. This was obtained from the Town Property Records for Building Permit 1983-7768. • Septic Disposal Permit Application from Building Permit file 1983-7768. • A Town of Queensbury inspection certificate, dated 8/2/1983 signed by building inspector Mack A. Dean indicating the absorption field was inspected and can be covered. This was also obtained from the building permit file. Based upon the documentation referenced, the existing system consists of a 1,000-gallon septic tank, a 1,000-gallon pump station and an absorption field consisting of a 10'x60' absorption bed in mound configuration, with pressure distribution. Original system design capacity was 600 GPD. The proposed project will replace the existing septic tank and pump station with a 1,250 gallon septic tank and 1,000 gallon pump station. Based upon our field inspection, it appears minimum setbacks to water supply wells and water bodies are maintained, and there is no evidence of failure of the absorption area. Based upon our review of the above documentation and field inspection, it is my opinion that the absorption field as designed and installed, coupled with the proposed 1,250 gallon septic tank and pump tank are compliant with the current Town standard for septic systems (Chapter 136). I trust this information is sufficient for your immediate needs, however, please contact me if you wish to discuss. Best Regards, G. Thomas Hutchins, P.E. Cc: Curtis Dybas, R.A. G.Thomas Hutchins,P.E. thutchins@hutchinsengineering.com intertek . . lia Code Comp nce Research Report • Total Quality.Assured: . -Issue Date:02 14 2017. Revision Date: 02-28-2019 - - J3tis Renewal Pate: 01 01 2020 DIVISION:07.00 00—THERMAL AND MOISTURE 2:0 STATEMENT OF.COMPLIANCE PROTECTION Section:07 2100—Thermal Insulation JM COrband®oc SP•F complies with the Codes listed in Section :: Section:07 2119—Foamed In-Place Insulation 1.1,for:the properties stated in Section 1.2 and uses stated in Section 1.3, when installed as described in .this report, REPORT HOLDER: .. including#he::Conditionsof Use stated in Section 6. . Johns:Manville : - 717-17th Street 3:0 DESCRIPTION Denver,Colorado 80202 (800)654-3103 3:1 Materials: http://www:im:com/ . n o „ - 3:1.1 Insulation:JM Corbond®oc SPF is a:two-component;open'. SU -cell, spray-applied polyurethane. foam plastic REPORTBJECT: _ . � . .. insulation; The;:insulation :is produced in the::field. by JM Corbond®oc SPF Open-Cell Spray-Applied Polyurethane' : professional contractors : combining an isocyanate : Foam-Insulation "A" wcomponent " component With:a proprietary resin B , 1.0 SCOPE OF EVALUATION resulting-in.a product having a nominal density of 0 5.pcf The "A" co 1.1.This Research -Report addresses compliance with the „B„ co Months mponent has a shelf life of 12 mo hs and the followingCodes: - ths, both when • 2018,2015;2012,and 20091nternational Building Code® stored in factory-sealed containers at :temperatures .. between 50°F and 85°F. • 2018,2015,2012;and 2009 international Residential 3.1.2.. Intumescent Coatings: [description] • 2018,2015;2012,.and 2009International Energy :3.1:2:1 TPRZ FIRESHELL® ..JM-IC/JM-TC Coating: TPR2 Conservation Code®(IECC) FIRESHELL® JM-IC and JM-TC intumescent coatings are a propriet ary, water-based, one=part, coating manufactured NOTE: This report references: 2018 Code. Sections for.. by TPR2 Corporation. The coatings are supplied in 5=gallon earlier Code editions may differ: : pails and 557gallon drums; and have a shelf life of 12 • months when stored .in factory sealed containers at 1.2 JM Corbond® oc SPF has been evaluated for the temperatures above 45°F. Fireshell JM_TC complies with following properties(see Table 1): ICC-ES AC456 as'recognized:in ICC-ES ESR-3997. a Physical Properties . •Surface Burning Characteristics i 3.1:2.2 TPR2 FIRESHELL® IB4/F10E/TB. Coating . TPR2 • Thermal Resistance FIRESHELL® IB4/F10E/TB intumescent :coatings are f. Air Permeability : proprietary, water-based, one-part; coatings manufactured by TPR2 Corporation: FIRESHELL® IB4 is identical to 1.3JM Corbond® oc SPF.has been evaluated for the: FIRESHELL® JM-IC, and FIRESHELL® FlOE/TB is identical to : following uses(see Table 1): FIRESHELL® JM-TC. The coatings are supplied in 57gallon • Alternatives to thermal barriers pails and. 55-gallon drums, and have a shelf life of 12 • Alternatives to ignition barriers. -- months .when. stored, in factory=sealed containers:at • Use in Types I, II, Ill,and IV construction temperatures above 45"F. Fireshell F10E complies with ICC- • Use in Type V construction ES AC456 as recognized in ICC-ES ESR-3997. 545 E.Algonquin Road •Arlington Heights• Illinois • 60005 intertek.com buildin xccamaEo / g Intertek PCA 101 Version:21 December 2017'. - SFT-CCRR-OP-40b ti. •Code Compliance Research Report CCRR-1079 Page 2 of 8 3.1.2.3 DC315 Intumescent Coating: DC315 intumescent 5.1 General: The insulation must be.. installed in coating, manufactured by . International Fireproof accordance with the manufacturer's published installation Technology Inc., is a single-component, water-based, instructions,the applicable Code,and thisResearch Report. liquid-applied intumescent coating."The coating is supplied The manufacturer's published installation instructions and. in 5-gallon pails and 557gallon drums,and has a shelf life of this Research_ Report must be strictly adhered to, and a 12 months when stored in factory-sealed" containers at copy of;the.instructions must be available on the jobsite temperatures between 50°F and 80°F. . DC315 complies during installation. . with.. ICC ES AC456 . as -recognized in IAPMO Uniform Evaluation Service Report ER-0499. 5.2 Application: The insulation is spray-applied on the jobsite using plural-component metering and processing 3.1.2.4 No=Burn® Plus ThB: No-Burn® Plus ThB is a one-. equipment as recommended in the manufacturer's part water=based intumescent coating manufactured by published installation.instructions. The insulation must not No-Burn Inc. The coating is supplied in 5-gallon pails and be used in areas that have a maximum continuous service 55-gallon drums, and has a shelf life of 18 months when temperature greater than 180°F or in contact with heat stored in unopened containers between 40°F and 90°F. producing appliances.:.The.foam plastic insulation must not No=Burn® Plus ThB complies with .ICC-ES AC456 as be used in electrical outlet or junction boxes. The recognized in IAPMO Uniform Evaluation Service Report substrate mutt be free of moisture; .frost or ice, loose : ER-0305. scales, rust, oil, and grease or other surface contaminants. The insulation must be protected from the weather during 4.0 PERFORMANCE CHARACTERISTICS and after application. "The. insulation can be installed in multiple passes, up to 12 in. per pass, to the maximum 4.1 Surface Burning Characteristics: JM Corbond® oc SPF specified thickness. Multiple :passes can be applied to has a flame-spread index. of 25. .or less and a smoke- obtain the desired thickness. Refer to the-manufacturer's developed index of 450 or less, when tested in accordance installation instructions for appropriate expansion and cure • with "ASTM: E84 at a nominal thickness of 4 in. JM times between passes. Corbond® oc SPF may be installed at greater thicknesses as. described-in Sections 5.3 and 5.4 of this report. When the. 5.3 Thermal Barrier: insulation is separated from the interior living space of the building with minimum 1/2 in. thick gypsum board, the. 5.3.1 Application with a Prescriptive Thermal Barrier:" JM maximum insulation thickness is not limited. Under the Corbond® oc SPF must be separated from the interior of 2018. and 2015 IRC, a prescriptive thermal barrier of the building by an approved thermal barrier, such as minimum 23/32.in. thick wood structural panel is also minimum' 1/2 in. gypsum wallboard,' installed . using .permitted, and the maximum insulation thickness is not mechanical fasteners in accordance with applicable Code, limited. or an equivalent 15-minute:thermal barrier complying with IBC Section 2603.4 or IRC Section R316.4, as applicable, 4.2.Thermal Resistance: JM Corbond® oc SPF has thermal with exceptions as described in Sections 4.3.2 and 4.4, or resistance (R-values) at a mean temperature of 75°F as when applied to a sill plate or header in dwellings under shown in Table 2.. the IRC at a maximum insulation thickness of 3-1/4:in, as permitted.by IRC Section R316.5.11. When the insulation is . 3.2.3 Air Permeability: JM Corbond® oc SPF, at a separated from the interior living space of the building with minimum thickness of 3-3/4 in., is considered air- prescriptive thermal barrier of minimum 1/2 in. thick impermeable insulation in accordance with IBC Section gypsurri board, the maximum insulation thickness is not 202[not applicable under the .2012 and 2009 IBC] or IRC limited. Under the 2018 and 2015.IRC; a thermal barrier of Section R202, based on testing in accordance with ASTM minimum 23/32 in. thick wood structural panels is also E2178. permitted, and -the maximum insulation thickness is not limited. 5.0 INSTALLATION 545 E.Algonquin Road •Arlington Heights• Illinois • 60005 MIS intertek.com/ g buildin ACG4ED ED Intertek PCA-101 Version:21 December 2017 SFT-CCRR-OP-40b 0 Code Compliance Research Report CCRR-1079 Page 3 of 8 5.3.2 Application without a Prescriptive Thermal Barrier: b. There are no interconnected attic or crawl space areas. JM Corbond® oc SPF may be spray-applied to the interior c. Air in the attic or crawl space is not circulated to other surface of walls, the underside of roof sheathing, and in parts of the building. crawl spaces without the 15-minute thermal barrier d. Attic ventilation .is provided when required by IBC prescribed in the IBC Section 2603.4 and IRC Section Section 1202.2 or IRC Section R806, except air R316.4,-when all surfaces of the JM Corbond®.oc SPF impermeable insulation is permitted in unvented attics insulation are covered with intumescent .coating as in accordance with IBC Section 1.202.3 [not applicable described in Table 3. under the 2012 or 2009 IBC] or IRC Section R806.5. e. Under-floor(crawl space) ventilation is provided when The insulation and coating may be left exposed as an required by IBC Section 1202.4 or IRC Section R408.1, as interior finish without the prescriptive thermal or ignition applicable: barrier. f. Combustion air .is- provided in accordance with IMC (International Mechanical Code®)Section 701 The coating must be applied when ambient and substrate temperatures are above 50'F. and less than 70% relative 5.4.2:1 'Attics and Crawl Spaces: In attics, the insulation humidity, unless otherwise permitted by the coating may be spray-:applied to the underside of roof sheathing or manufacturer's installation instructions. Surfaces to be roof rafters, and/or vertical surfaces, provided the coated must be clean, dry, and free of loose dirt, loose assembly conforms to one of the assemblies described in debris, and any other substances that could interfere with Table 4. 'In crawl spaces, the insulation may be spray- the adhesion of the coating. applied to the underside of floors and/or vertical surfaces provided the assembly conforms to One of the assemblies 5.4 Attics and Crawl Spaces: described in Table 4: When an intumescent coating is used, surfaces to be coated must be dry,clean, and free of 5.4:1 Application with a Prescriptive Ignition Barrier: dirt; loose debris; and any other substances that could When JM Corbond® oc SPF insulation is installed within interfere with adhesion of the coating. The intumescent attics or crawl spaces,where entry is made only for service coating must be applied to all surfaces in accordance with • of utilities, an ignition barrier must be installed in the respective coating manufacturer's installation accordance _with IBC Section 2603.4.1.6 or- IRC Section instructions. The coating must be applied .when ambient. R316.5.3 or R316.5.4, as applicable. The ignition barrier and substrate temperatures are above of 50°F and less must be consistent with the requirements for the type of than 70% relative humidity, unless otherwise permitted by construction required by the applicable Code and must be the intumescent coating manufacturer's installation installed in a manner so that the foam plastic insulation is instructions. The insulation may be installed in unvented not exposed.The insulation,as specified in this section may attics as described in this section and in accordance with be installed in unvented attics and unvented enclosed 2015 IBC Section 1202.3 or IRC Section R806.5 [2009 - rafter assemblies in accordance with 2015 IBC Section R806.4]at a minimum thickness of 3-3/4 in. 1202.3 or IRC Section R806.5: 5.4.2.2 Use on Attic Floors: When installed on the attic 5.4.2 Application without a Prescriptive Ignition Barrier: floor only, JM Corbond® oc SPF insulation is approved for JM Corbond® oc SPF insulation may be installed in an attic exposed (without a protective covering) installation in attic or crawl space without the prescriptive ignition barrier floors up to a maximum thickness of 16 in. The ignition described in IBC Section 2603.4.1:6 and IRC Sections barrier described'in IBC Section 2603.4.1.6 or IRC Section R316.5.3 and R316.5.4, as described in Section 5.4.2.1 or R316.5:3 is not required. 5.4.2.2,when all of the following conditions are met and as described in Section 5.4.2.3 when conditions a. through c. 5.4.2.3 Unvented Attics: Johns Manville has conducted and condition f.are met: end-use configuration testing (per IBC Section 2603.9 • [2603.10] and IRC Section R316.6); and analysis to qualify a. Entry to the attic or crawl space is only for the service of the use of JM Corbond® oc SPF insulation without a utilities and no storage is permitted. prescriptive ignition barrier or intumescent coating in ®, 545 E.Algonquin Road • Arlington Heights • Illinois • 60005 intertek.com/building `�`RCD1E0 !i lntertek PCA-poi Version:21 December 2017 SFT-CCRR-OP-40b • .111 . Code.Compliance Research Report CCRR-1079 Page 4 of 8 unvented attics conforming with 2015 IBC Section 1202.3 6.2 The insulation must be separated from the interior of or IRC Section R806.. (Note that unvented attics were not the building by an approved 15-minute thermal barrier as addressed in the 2012 and earlier versions of the IBC).The described in Section 5.3.1, except as described in Sections testing and analysis is described in Priest &Associates EEV 5.3.2 and 5.4. . . 10409 Revision 1, dated December 20,. 2016. The conclusions of that evaluation are as follows: When JM 6.3 The installed thickness must not exceed that noted in • Corbond® oc SPF is applied in unvented attics.conforming Sections 4.2,5.3,5.4,and 5.5. to IBC Section 1202.3 or IRC Section R806.5 [2009•— R806.4];the insulation may be applied to the underside of 6.4 The insulation must be protected from the weather roof sheathing and/or rafters, and.to vertical surfaces to a during and after application. minimum thickness of-3-3/4 in.:Rafters may be left without foam coverage or may be covered -with foam up to the 6.5 A vapor retarder must be installed in-accordance.with maximum thickness allowed. Maximum thickness on the the applicable Code. underside of roof sheathing or on vertical wall surfaces is 16 in. The insulation may be left exposed to the attic 6.6-The insulation must be applied by professional spray without a prescriptive ignition barrier or an intumescent polyurethane foam installers approved by Johns Manville coating. The attic must have attic access;complying with or by the Spray Polyurethane Foam Alliance.(SPFA) for the IRC:Section.R807, horizontally placed in the attic floor, and installation of spray polyurethane foam insulation. opening outward toward the living space. For items penetrating the roof deck or walls,such as skylight wells or 6.7 When JM Corbond®oc SPF insulation is installed under vents, all surfaces of the penetrating item exposed in the the conditions. of Section 4.4.2.1 of this report, the attic must be covered with a minimum of 3-3/4 in. of JM following conditions apply: Corbond®oc SPF insulation. 6.7.1 Since the performance of JM Corbond® oc SPF, 5.5 Exterior Walls in Types.I; _II, III, and IV Construction: when installed in unvented attics without a Code JM Corbond® oc SPF insulation may be installed in or on prescribed ignition barrier or an intumescent coating, is the interior side of exterior walls of buildings of.Types I, II, based on fire performance of an unvented attic, the Ill, and IV construction complying with IBC Section 2603.5 . installation must be approved by the Code official. The and as described in this section. The potential heat of JM installation must conform with the provisions of Section Corbond® oc SPF is 557 Btu/ft2 per in: of thickness. The 5.4.2:3, and conditions a: through c., and condition f. of tested wall assembly was extended through a third-party Section 5:4.2. A copy of the Priest & Associates engineering analysis to include additional wall Engineering Evaluation (referenced in Section 5.4) must be constructions described in Table 5. provided to the Code official upon request. 6.0 CONDITIONS OF USE 6.7:2 Signage shall be permanently affixed in the attic and shall be visible from all points within the attic. The sign The JM Corbond® oc.SPF spray-applied polyurethane foam shall state "Caution, this is an unvented attic by design:No insulation described in this Research Report complies with,or modification may be made to this unvented condition..The is a suitable alternative to, what is specified in those Codes attic shall not be vented Holes into the unvented attic shall listed in Section 1.0 of this report, subject to the following be immediately repaired and sealed. Penetrations of the conditions: - ceiling or wall membrane between the unvented attic and living space, other than the horizontal access hatch, must 6.1 Installation must comply with this Research Report, be protected in an approved manner: This unvented attic the:manufacturer's published installation instructions, and shall not be used for storage. See lntertek Code Compliance the applicable Code. In the event of a conflict between the Research Report CCRR=1079.on the lntertek Website." manufacturer's instructions and this report, this report governs. - 6.8 Use of the insulation in fire-resistance-rated construction in outside the scope of this report. (11,14 545 E.Algonquin Road •Arlington Heights • Illinois • 60005 intertek.com/buildinglas- - `RC°"ED Intertek Pcl1.10 I Version:21 December 2017 SFT-CCRR-OP-40b • Code Compliance Research Report CCRR-1079 Page 5 of 8 6.9Use of the insulation in areas where the probability of 7.6 Intertek Listing Report "JM Corbond® oc SPF", on the termite infestation is "very heavy" must be in accordance Intertek Directory of Building Products. with IBC Section 2603.8 or IRC Section R318.4, as applicable. 8.0 IDENTIFICATION • • 6.10 Jobsite certification and labeling of the insulation . Each container of components A and B.of the insulation bears . . must comply with IRC Section N1101.10 and N1101.14,and a label With the Johns Manville name.and address; the IECC Sections C303.1 or R303.1 and R401.3,as applicable. product name;: the flame-spread and 'smoke-developed indices; the .expiration date, the Intertek.Mark as shown 6.11 The insulation components are manufactured under below; and. the Research .Report number -(CCR R-1079). a quality control program with inspection- by Intertek Intumescent coatings are identified with the manufacturer's -. - Testing Services NA,Inc. name and address, the product trade name and use instructions. 7.0 SUPPORTING EVIDENCE • .CODE' COMPLIANCE. 7.1 Reports of tests in accordance with ASTM C518, ASTM D1622, ASTM :D1623, ASTM D2126, ASTM D6226, ASTM E84, ASTM E2178, NFPA 259, NFPA 285, NFPA 286, and UL • - 1715. Intertek: . 7.2 Data in accordance with the ICC-ES Acceptance Criteria CCRR-##i#t for Spray-Applied Foam Plastic Insulation (AC377), dated April 2016, including reports. of.tests in accordance with : . 8.0 OTHER CODES Appendix X. • . This section is not applicable. 7.3 Jensen Hughes letter,,'dated June 26, 2015, Re: Project. • 1AJP00150.000. 9.0 CODE COMPLIANCE RESEARCH REPORT USE 7.4-Research Reports for evaluation of data in accordance 9.1 Approval of building products and/or materials can with ICC-ES Acceptance Criteria for Fire-protective Coatings • only be granted'by a building official having legal authority Applied to Spray-applied Foam Plastic Insulation Installed in the.specific jurisdiction where approval is sought. without.a Code-prescribed Thermal Barrier (AC456), dated October 2015. 9.2 Code Compliance Research Reports shall not:be used • in any mariner that implies an endorsement of the product 7.5- Priest & Associates Engineering Evaluation 10409 by Intertek. Revision 1, dated December. 20, 2016, entitled "For Inclusion of Johns Manville's -JM Corbond® oc SPF 9:3 'Reference to the https://bpdirectory.intertek.com is Insulation in Unvented Attics without an Ignition Barrier in recommended to ascertain the current version and status Intertek CCRR." of this report. This Code Compliance Research Report("Report")is for the exclusive use of lntertek's Client and is provided pursuant to the agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the-terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss;expense or damage occasioned by the use of this Report.Only the Client is authorized to permit copying or distribution of this Report and then only in its'entirety,and the Client shall not use the Report in a misleading manner. Client further agrees and understands that reliance upon the Report is limited to the representations made therein. The Report is not an endorsement or recommendation for use of the subject and/or product described herein. This Report is:not the Intertek Listing Report covering the subject product and utilized for Intertek Certification and this Report does not represent authorization for the use of any Intertek certification marks.Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in writing by Intertek. . • . 545 E.Algonquin Road •Arlington Heights • Illinois • 60005. intertek.com buildin uc muro - Intertek PCA-101 Version:21 December 2017 • SFT-CCRR-OP-40b .. Code Compliance Research Report CCRR-1079 Page 6 of 8 TABLE 1-PROPERTIES EVALUATED 2018 IBC 2018 IRC '2018 IECC PROPERTY SECTION' SECTION' , , SECTION' Physical properties Not required Not required Not required . . Surface burning 2603.3 R316.3 Not applicable characteristics - . Alternative to thermal 2603.4 . R316.4 Not applicable barrier/ignition barrier Air permeability 202, 1202.3 R202, R806.5 C402.4, R402.4 Exterior walls in Types I=1V 2603..5 . Not applicable Not applicable construction C303.1.1, .. N11.01.10, C303.1.4, Thermal resistance 1301 N1102 R303:1.1; R303.1.4 . . 1 Section numbers may be different for earlier versions of the International Codes. TABLE 2—THERMAL RESISTANCEI'2 THICKNESS _ lue(°F.ft2.hr/ t (in.) R va B u) . 1 3.8 2 7.4 3 11 3.5 13 5.5 20 7 25 9 33 9.25 . 33 10 36 11.25 41 12 43 16 58 1 R-values are calculated based on the test K values at 1 and 3.5 in.thicknesses. 2 R-values greater than 10 are rounded to the nearest whole number. 11), 545 E.Algonquin Road •Arlington Heights Illinois • 60005Ntkatof this intertek.com/building 4ccaron[n Intertek - PCA-,o, Version:21 December 2017 SET-CCRR-OP-40b Code Compliance Research Report CCRR-1079 Page 7 of 8 TABLE 3—USE OF INSULATION WITHOUT A PRESCRIPTIVE THERMAL BARRIER MAXIMUM MINIMUM MAXIMUM INTUMESCENT COATING, INSULATION THICKNESS(in.) THICKNESS(in.) MINIMUM THICKNESS& APPLICATION TEST TYPE (Wall Cavities and (Underside of Roof TYPE(Applied to all RATE OF SUBMITTED Attic Floor) Sheathing/Rafters Exposed Foam Surfaces) INTUMESCENT (AC377) and Floors) COATING FIRESHELL®JM-IC 7-1/2 9-1/2 18 mil wet film thickness 1.2 gal./100 ft2 NFPA 286 (12 mil dry film) FIRESHELL® 1B4 JM 7-1/2 9-1/2 18 mil wet film thickness 1.2 gal/100 ft2 NFPA 286 Corbond®oc (12 mil dry film) SPF DC315 7-1/2 11=1/2 18 mil wet film thickness. 1.1 gal/100 ft2 NFPA 286 (12 mil dry film) No-Burn Plus ThB 6 14 14 mil wet film thickness •0.9 gal-/100 ft2 UL 1715 (9 mil dry film) TABLE 4—USE OF INSULATION IN ATTICS AND CRAWL SPACES WITHOUT A PRESCRIPTIVE IGNITION.BARRIER MAXIMUM MINIMUM MAXIMUM INTUMESCENT COATING, INSULATION THICKNESS(in.) THICKNESS(in.) MINIMUM THICKNESS& APPLICATION TEST TYPE (Wall Cavities and (Underside of Roof TYPE(Applied to all RATE OF SUBMITTED Attic Floor) Sheathing/Rafters Exposed Foam Surfaces) INTUMESCENT (AC377) and Floors) COATING FIRESHELL®JM-IC 7-1/2 9-1/2 4 mil wet film thickness 0.27 gal/100 ft2 Appendix X (3 mil dry film) JM FIRESHELL® IB4 Corbond®oc. 7-1/2 9-1/2 4 Mil wet film thickness 0.27 gal/100 ft2 Appendix X SPF (3 mil dry film) DC315. 9-1/2 11-1/2 4 mil wet film thickness 0.25 gal/100 ft2 Appendix.X (3 mil dry film) 545 E.Algonquin Road •Arlington Heights • Illinois • 60005 intertek.com/building "`aEO;`fD Intertek PCA-101 Version:21 December 2017 SFT-CCRR-OP-40b lfl ,0 Code Compliance Research Report CCRR-1079 Page 8 of 8 TABLE 5—NFPA 285 COMPLYING WALLS—JM Corbond®oc SPF IN INTERIOR WALL CAVITY Wall Component Materials 1- Concrete wall 2= Concrete Masonry wall 3-One layer of 5/8 in.thick Type X gypsum wallboard installed on the interior side of Base wall system minimum 3=5/8 in.deep,minimum 20 GA thick steel studs spaced a maximum of 24 in.on Use either 1,2 or 3 center. Lateral bracing installed minimum every 4 ft:vertically or as required. Wall stud cavities shall be filled at each floor line with minimum 4 pcf mineral wool(e.g. Thermafiber)friction fit between steel wall studs. Perimeter fire barrier system complying with IBC Section 715.4 shall be installed,as Perimeter Fire Barrier applicable,to fillthe void between the edge of the concrete floor slab and the interior System surface of the exterior wall assembly . Full wall stud cavity depth or less of JM Corbond®ocSPF applied using exterior gypsum Wall Cavity Insulation sheathing as the substrate and covering the width of the cavity and the inside of the steel wall stud.framing flange Exterior sheathing . . 5/8 in.thick Type X exterior type gypsum sheathing complying with ASTM C1177. . 1-Any non-combustible exterior wall covering material using any standard installation Exterior Wall Covering— technique Use either 1,2,or 3(See 2-Any non-combustible exterior wall covering system with a combustible WRB that has Note 3) successfully been tested in accordance with NFPA 285 3=Any combustible exterior wall covering system with or without a combustible WRB that has been_successfully been tested in accordance with NFPA 285 . Flashing of window, . door,and other As an option,flash around window,door,and other exterior penetrations with limited exterior wall amounts of maximum 12 in.wide flashing tape:(acrylic,asphalt,or butyl-based)or liquid penetrations. applied membrane material with or without fiber mesh reinforcement Note 1: Fireblocking per IBC Section 718 and thermal barrier material requirements must be met for Base Wall Systems 1 and 2,as required by specific wall construction details when combustible concealed space is created on interior side of exterior wall assembly. Note 2: Combustible exterior wall coverings shall be installed in accordance with manufacturer s requirements. 545 E.Algonquin Road •Arlington Heights • Illinois • 60005 intertek.com buildin �E°kia ita "`° R . Intertek CA-1 O1 Version:21 December 2017 SFT-CCRR-OP-40b . ' . kiZti EVALUATION REPORT Number 146 • • .TM Originally Issued: 07/31/2015 • Revised: 12/11/2018 Valid Through: 07/31/2019 . JOHNS MANVILLE 2.4 JM Corbond III® insulation shall be installed by- 71717th Street contractors certified by SPFA or Johns.Manville. • Denver,'Colorado 80202 2.5 When JM Corbond•III®insulation is used in areas where • 800-654-3103 the likelihood of termite infestation is "very heavy," it shall . www.specjm.com be installed in accordance with IBC Section 2603.9 (2009 • IBC Section 2603.8)or IRC'Section R318.4,'as applicable. • JM CORBOND Ill®PERFORMANCE INSULATION SYSTEM® 2.5.1 When JM Corbond III® is used in conjunction .with wood construction, in jurisdictions that have adopted NFPA . CSI Section: . . 5000,and where termite infestation is known to be heavy,the 07 21 00 Thermal Insulation foam plastic shall be installed in accordance with NFPA 5000 Section 45.6.9.5. 1.0 RECOGNITION 2.6 When used in exterior walls of buildings of Type I,II,III Johns Manville JM Corbond 111® Performance Insulation or"IV construction, application shall be as described in System®described in this report was evaluated for use as Section 3.5•of this•report. • foam plastic insulation. .The,surface burning characteristics, thermal performance, .physical; air infiltration, vapor 3.0 PRODUCT USE permeance, fungal resistance, and thermal barrier properties of the Johns Manville JM Corbond III®were evaluated for JM Corbond III® is a non-structural, closed cell, spray compliance with the following.codes: • applied,polyurethane foam plastic insulation for use in wall - cavities, floor assemblies, ceiling assemblies, and attics and 2015, 2012 and 2009 International Building Code® crawl spaces: The foam:plastic insulation -complies with (IBC) Section 2603 of the•IBC, Section R316 of the IRC, and • • 2015, 2012 and 2009 International Residential Sections C402 and R402 of the IECC (2009 IECC Sections Code®(IRC)" • Code® and 402)and Section 4804 of NFPA 5000 for the specific . uses described in this report. The insulation may.be used in • 2015,. .:2012 and 2009 International Energy buildings of Types l; II,III, IV, and V Constriction per the Conservation Code®(IECC) IBC,residential structures constructed inaccordance with the : • 2015, 2012 and 2009 NFPA 5000 Building IRC, and buildings of Type I, II, III, IV, and V construction . • . Construction and.Safety Code per NFPA 5000. - 2.0 LIMITATIONS • - 3.1 General Use of the JM Corbond III® •spray-applied foam plastic 3,2 Application insulation described in this report.is subject to the following limitations: 3.2.1 JM Corbond III®shall be installed by spray application using a dual component, volumetric, positive displacement - 2.1 The product shall be installed in•accordance with the proportioner to combine A- and B-components in a one to manufacturer's published .installation" instructions, this one volumetric ratio, as specified in the Manufacturer's • evaluation report and the applicable code. In the event of a installation instructions. ct confli the more restrictive shall govern. 3.2.2 JM Corbond III®shall not be applied to areas where the 2.2 JM Corbond III® insulation shall be protected by a 15- maximum service temperature is.greater than 180°F(82°C) minute thermal barrier in accordance.with Section 4.3 of this JM Corbond®III shall be applied to substrates that are clean, report except when installation complies with one or more of ". dry,and free from frost,ice,loose debris or contaminants that the following: • " will interfere with the adhesion of the spray foam insulation. JM Corbond III® shall not be applied in electrical outlets, (1)Exceptions specifically provided in the applicable code; junction boxes, to substrates over 120°F (49°C), or in direct (2)Section 3.3.3.(Application without'a Prescriptive Thermal contact with water and shall be protected from the weather Barrier)of this report; during application. (3)Section 3.4(Attics and Crawl Spaces)of this report. 3.2.3 JM Corbond III®may be applied in passes of uniform 2.3 Theinsulation components are produced by Johns thickness from a minimum of%inch(13 mm)to a maximum Manville under a.quality control program with inspections of 31/2 inches.(89 mm)per pass. The total thickness shall be .under the supervision of UES. as specified in Sections 3.3,3.4,and 3.5 of this report. ,,,.,,UNIt) • The product described in this Unifoim Evaluation Service(UES)Report has been evaluated as an alternative material,design or method of construction in order to satisfy and comply with the intent of the provision of the code,as noted in this report,and for at least equivalence to that prescribed in the code in quality,strength,effectiveness,fire resistance,durability and safely, as applicable,in accordance with IBC Section 104.11.This document shall only be reproduced in its entirety. . Copyright©.2018 by International Association of Plumbing and Mechanical Officials.All rights reserved.Printed in the United States. Ph:1-877-41ESRPT•Fax:909.472.4171 ANSI web:www.uniform-es.org•4755 East Philadelphia Street,Ontario,California 91761-2816—USA a.ecenmm 150,1EC 17065 111104° - EVALUATION REPORT Number.• �y 146 TM Originally Issued: 07/31/2015 Revised: 12/11/2018 Valid Through: 07/31/2019 "Flash"passes or a thin pass of less than 1 inch(25 mm) on 3.4.3 Application without a Prescriptive Ignition Barrier: cold surfaces is to be avoided_and may result in loss of The spray-applied foam plastic insulation may be installed adhesion of subsequent passes. Thicknesses over 31/2 inches without a prescriptive ignition barrier in accordance with (89, mm) require multiple passes, in accordance with Section 3.4.2.1, 3.4.2.2.or 3.4.2.3 of this report, when all of manufacturers installation instructions. the following conditions apply,as applicable: 3.3-Thermal Barrier a) Entry to the attic or crawl space is only to service utilities,and no storage is permitted. 3.3.1 General: :JM Corbond III® shall be covered with a b) Attic ventilation is provided when required by IBC thermal barrier except as specifically excluded by the Section 1203.2 or IRC Section R806, except when.. applicable code. . an 'air-impermeable insulation is permitted in unvented attics in accordance with Section R806.4 3.3.2 Application with a Prescriptive Thermal Barrier: of the IRC:Under-floor(crawl space)ventilation is JM Corbond®III may be applied at any thickness in ceiling provided when required by 2015 IBC Section cavities and in wall cavities when separated from the interior 1203.4(2012 and 2009 IBC Section 1203.3)or IRC of the building by a prescriptive thermal barrier (minimum Section R408:1,as applicable. 1/2-inch[12.7 mm] thick gypsum board).The gypsum board shall be installed in accordance with the applicable provisions c) 'The foam. .plastic insulation is limited to the in Section 2508.of the IBC, Section R702.3 of the IRC or maximum thickness and density stated in this report. Section 47.2 of NFPA 5000 in such a manner that the foam d) .Combustion air.is provided in accordance with . . plastic is not exposed. Sections 701 and 703 (2006 IMC) and Section 701 (2009 IMC). 3.3.3 Application. without . a- Prescriptive Thermal e) The installed coverage rate or thickness of coatings, Barrier: JM .Corbond III® may be installed without a if part of the insulation system, shall be equal to or prescriptive' thermal barrier when it has been installed in greater than that which was tested. accordance with one of the assemblies in.Table 2 of this f) . Attic and crawl spaces do not have interconnected report. areas. g) Air in the attic or crawl space is not circulated to 3.4 Attics.and Crawl Spaces other parts of the.building. 3.4.1 General: When installing JM Corbond III® in attics 3.4.3.1 Attic and Crawl Space Overhead and Vertical and/or crawl spaces and a thermal•barrier is omitted in Surfaces Covered with an Alternative Ignition Barrier:. accordance with IBC Section 2603.4.1.6, IRC Sections JM Corbond III®spray foam insulation may be spray-applied R316.5.3 or R316.5.4 or Section 48.3.3.4 of NFPA 5000, without a.prescriptive ignition barrier to overhead surfaces installation shall comply with either Sections 3.4.1 or 3.4.2 and/or vertical surfaces when covered with an alternative of this report. ignition barrier as described in Sections 3.4.2.1.1,or 3.4.2.1.2 (and as summarized in Table 5) of this report. JM Corbond® III spray-foam insulation qualifies as an air- impermeable insulation and, when installed in accordance 3.4.3.1.1 JM IC Ignition Barrier: Surfaces to be' coated with Sections 3.4:2 or 3.4.3 of this report, may be used to shall be dry, clean, and free of dirt, loose particles and any insulate unvented attics and/or unvented cathedral ceilings in other substances that could interfere with adhesion of the accordance with 2015 IRC Section R806.5 (2012 and 2009 coating. Back-rolling of sprayed material may be necessary IRC SectionR806.4). to fill pinholes in substrates.The JM IC Ignition Barrier shall be applied with a medium-size nap roller, soft brush or 3.4.2 Application with-a Prescriptive Ignition Barrier: , conventional airless spray equipment to a minimum dry,film When JM Corbond III® insulation is installed within attics thickness of 3 mils (0.08 mm) (requiring an application rate and crawl spaces.where entry is made only service of utilities, of approximately 4 wet mils[0.10 mm]or 345 ft2/gal[8.3 m2 the insulation.shall be protected by an ignition barrier in /L]). The coating shall be applied in accordance with the JM accordance with IBC Section 2603.4.1.6, IRC Sections IB Product Data Sheet and this report. The maximum R316.5.3 andR316.5.4 or Section48.3.3.4 of NFPA 5000,as thickness of JM Corbond® III is limited to 5'/2 inches (140 applicable.The ignition barrier shall be consistent with the mm)on overhead surfaces and 3'/2 inches(89 mm)on vertical construction type of the building:The ignition barrier shall be surfaces. installed in accordance with the provisions applicable to the material referenced in the IBC,IRC or NFPA 5000 in such a 3.4.3.1.2 JM Spider® with adhesive: JM Spider® with manner that the foam'plastic is not exposed. The maximum adhesive shall be installed by insulation contractors who have thickness of JM,,Cdrbond® III is limited to 11'/2 inches (292 been trained and certified by Johns Manville. Installers shall mm) on overhead surfaces and floors and 91/4 inches (235 use only the JM Spider® Insulation Delivery System mm)on vertical surfaces. equipment engineered and specified by Johns Manville. JM Spider®with adhesive shall be applied in accordance with Page 2 of 9 . kttip .Tam i-,i Y.' EVALUATION REPORT Number• ;N , 146 TM Originally Issued: 07/31/2015 Revised: 12/11/2018 Valid Through: 07/31/2019. Johns Manville installation specifications. If the installation 4.0 PRODUCT DESCRIPTION temperatures are below 50°F (10°C) the adhesive shall be heated and applied per Johns Manville specifications. JM 4.1 General Spider® with adhesive spray-on i insulation shall be installed at a minimum 2Y2 inches (63.5 mm)thickness and a nominal 4.1.1 JM.Corbond III® is a two-component, spray-applied, density of 1.8 pcf(28.8 kg/m3). The maximum thickness of medium-density, closed-cell polyurethane foam plastic JM Corbond® III is limited to 10 inches.(254 mm) on insulation system having a nominal core density of 2.0 pcf overhead surfaces and 8 inches (203 mm) on vertical (32 kg/m3).The foam plastic is generated by combining the surfaces. isocyanate (A-component) and a polymeric resin (B- component)through a dual component proportioner,on site, 3.4.3.2 Attic Floors: JM Corbond III® insulation may be by SPFA certified or Johns Manville certified applicators. installed exposed(no coating),without an ignition barrier up All materials shall be stored in their original containers, to a maximum thickness of 11'/2'inches (292 mm) between which shall be kept out of direct sunlight and away from heat. and over the joist in attic floors. The insulation shall be and moisture. When stored unopened. and indoors at a separated from the interior of the building by a minimum'/2- temperature between 50°F(10°C)and 80°F(27°C),the shelf inch (12.7 mm) thick gypsum board or an approved life for. A-component isocyanate is. 12 months, and B- equivalent thermal barrier, which shall be installed in component polymeric resin is 6 months. Prior to use, both accordance with the provisions set forth in the IBC, IRC, or components(A and B)shall be conditioned in a manner that evaluation.. report. The ignition barrier required by IBC results in drum temperatures between 60°F(16°C)and 75°F Section2603.4 and IRC Section R316.5.3 may be omitted in (24°C): this case. 4.1.2,A-component isocyanate and B-component polymeric 3.4.3.3 Attic and Crawl Space Overhead and Vertical resin properly mixed and applied yields a Lavender®finished Surfaces Without an Ignition Barrier: The JM Corbond foam.insulation product. The Lavender® color is a Federal III®can be installed exposed(no coating),without an ignition Registered Trademark color of Johns Manville. barrier when installed as required in this section.JM Corbond. III®insulation may be spray-applied in attics to the underside 4.2 Surface Burning Characteristics.. of roof sheathing, roof rafters and vertical surfaces, and in crawl spaces to the underside of floors and vertical surfaces. 4.2.1 JM Corbond III®, when tested..in accordance with When applied to the underside of the top of the space, the ASTM E84, at'a maximum thickness of 4 inches (102 mm), thickness of the JM Corbond III®insulation shall not exceed and;a nominal core density of 2.0 pcf(32 kg/m3),has"a flame 71/2 inches (191 mm) and when applied to vertical surfaces, spread index of less.than 25 and a smoke developed index of the maximum thickness'shall not exceed 51/2 inches (140 .not more than 450: mm). 4.2.2 Thicknesses are not limited for ceiling cavities and wall 3.5 Exterior Walls of Types I,II,III and IV Construction cavities when covered by a prescriptive thermal barrier (IBC) (minimum '/2-inch ' [12.7 mm] thick gypsum board) in accordance with Section 3.3.1 of this report. Thicknesses of 3.5.1 When used on exterior walls of Type I, II, III and IV up to 11'/2 inches (292 mm) for ceiling or floor cavities and construction,JM Corbond III®spray-applied foam insulation 7''A inches (191 mm) for wall cavities are recognized based shall comply with Section 2603.5 of the IBC or Section . on testing in accordance with NFPA 286, when installed in.. 48.4.1 of NFPA 500, as applicable and Section 3.5.2 of this accordance with Section 3.3.2 of this report. report, and shall be installed at a maximum thickness of 31/2 inches(88.9 mm).The potential heat of the JM Corbond III® 4.3 Thermal Resistance:The R-value of JM Corbond III®is is 1991 BTU/ft2 (22.4 MJ/m2) per inch of thickness when 7.0 per inch regardless of thickness. Table 1 of this report tested in accordance with NFPA 259. provides additional information on the values of thermal resistance(R-Value)for specific thicknesses. 3.5.2 Specific Wall Assemblies: Wall assemblies shall be constructed as described in Tables 3 and 4 of this report. 4.4 Water Vapor Resistance:JM Corbond III®,when tested in accordance with Procedure A of ASTM E96,has a vapor 3.6 Installation permeance of less than 1 perm(57 ng/Pa-s-m2)at a minimum thickness of 1.5 inches (38 mm), and qualifies as a Class II 3.6.1 Installation General: JM Corbond III® shall be vapor retarder as defined in IBC Section 202, IRC Section R202 and 2015 NFPA 5000 Section 3.3.662.1 (2012 and installed in accordance with the manufacturer's installation 2009 NFPA 5000 Section 3.3.644.1). instructions, the applicable code and this report. Where conflicts occur the more restrictive shall govern. The 4.5 Air Permeability: JM Corbond III®, when tested in installation instructions and this report shall be made accordance with ASTM E283 at a minimum thickness of 1.0 available upon request. inches (25.4 mm) exhibits a maximum total air leakage rate of 0.02 L/s-m2(0.004 ft3/min-ft2)when tested at a 75 Pa Page 3 of 9 s %It* EVALUATION REPORT Number ` 146 TM Originally Issued: 07/31/2015 Revised: 12/11/2018 Valid Through: 07/31/2019 pressure differential and qualifies as an air-impermeable 5.0 IDENTIFICATION insulation for use in attics in accordance with the applicable code. Jobsite labeling and certification of the insulation shall comply with IRC Sections N1101.10 and 1101.10.1 (2012 4.6.Fungal Resistance: JM Corbond III®, when tested in IRC Sections 1101.12 and 1101.12.1 and 2009 IRC Sections accordance with ASTM C1338.exhibits no fungal growth. N1101.4 and N1101.4.1) and IECC Sections C303.1.1 and C303.1.2, R303.1.1 and R303.1.2 as. applicable. Each 4.7 Fire Protective Coatings component for the JM Corbond III® is identified with the following: 4.7.1 JM IC (aka TPR2 Fireshell® IB4): JM IC ignition barrier coating is manufactured by Thermal Products • Manufacturer's name (Johns Manville), address and Research (TPR2). The coating is water-based and available telephone number, in both 5-gallon (18.9 L) and 55 gallon (208 L) containers • Product trade name(JM Corbond and has a shelf life of 12 months when stored in factory- • Product density, sealed containers above 45°C(7°C). • Flame-spread and smoke-development indices and the name of the inspection agency (IAPMO R & T 4.7.2 JM TC (aka Fireshell® F10/E/TB): JM TC thermal Laboratory), barrier coating is manufactured by Thermal .Products • Evaluation report number(ER146), and the name of the Research (TPR2). The coating is water-based and available inspection agency(IAPMO ES). in both 5-gallon (18.9 L) and 55 gallon (208 L) containers and has a shelf life of 12 months when stored in factory- Either Mark of Conformity may be used as shown below: sealed containers above 45°C(7°C) - 4.7.3 DC315 Fireproof. Paint: DC315 Fireproof Paint, recognized in ER-499, is a water-based latex intumescent 711311R MU E coating manufactured by International.Fireproof Technology, 1411i,Inc. and is supplied.in 5-gallon (19 L) pails and 55-gallon (208 L) drums.-When stored in factory-sealed containers at temperatures between 50°F (10°C) and 80°F (27°C), the "'', or coating has a shelf life of 12 months: IAPMO UES ER-146 4.7.4 No-Burn® Plus -ThB Coating: .No-Bum Plus ThB coating, recognized in ER-305, is a water-based latex liquid 6.0 SUBSTANTIATING DATA manufactured by No-Bum, Inc:, which exhibits intumescent properties when exposed to elevated temperatures arid flame. 6.1 Data in accordance with ICC-ES Acceptance Criteria for The 'product is packaged. in 5-gallon pails and 55-gallon :Spray-Applied Foam Plastic Insulation (AC377) Approved drums and has a shelf life of eighteen months when stored in April 2016. unopened containers between 40°F and 90°F. 6.2 Reports on air leakage tests in accordance with ASTM 4.8 JM Spider®Ignition Barrier E283. 4.8.1 JM Spider® ignition barrier is supplied by Johns 6.3 Reports on water vapor transmission tests in accordance Manville Corporation:The JM Spider® loose-fill glass fiber with ASTM E96. material is mixed with an adhesive.during the spraying process and adheres to the foam plastic. The JM Spider®is 6.4 Reports on Fungal Resistance tests in accordance with available in 30 lb(13.6 kg)bags.The ignition barrier shall be ASTM C1338. kept clean and dry at all times'. The spray-applied fiberglass product may be installed at variable thickness levels,and may 6.5 Reports on flame spread and heat release in accordance be used for both wall and ceiling applications. with NFPA 286. 4.8.2 The JM Spider®adhesive comes in totes and 55-gallon 6.6 Reports on Exterior Fire Propagation tests in accordance (208 L) drums: The adhesive shall be stored in a cool, dry with NFPA 285. area in original packaging and at temperatures above 40°F (4.4°C). 6.7 Reports on Potential Heat tests in accordance with NFPA 259. 6.8 Reports on Heat Release and Flame Propagation in accordance with AC377 Appendix X. Page 4 of 9 y , 111.1t, EVALUATION REPORT Number: ;3146 TM Originally Issued:. 07/31/2015 Revised: 12/11/2018 • Valid Through: 07/31/2019 7.0 STATEMENT.OF RECOGNITION This evaluation report describes the results of research carried out by IAPMO Uniform Evaluation Service on Johns Manville .JM .Corbond III® to assess .their conformance to..the codes shown in Section .I.0..of this report and serves as documentation of the product's certification. Products are manufactured under a quality control program with periodic inspections under the supervision of IAPMO UES. Brian Gerber,P:E.,S.E. Vice President,Technical Operation s Uniform Evaluation Service. Richard Beck,PE,CBO,MCP Vice President,Uniform Evaluation Service GP Russ Chan Y CEO,The:IAPMO Group For additional information about this evaluation report please visit www.uniform-es.org or email us at info@uniform-es.org Page 5 of f fti EVALUATION REPORT Number ' 146 "TM Originally Issued: 07/31/2015 Revised: 12/11/2018 Valid Through:.07/31/2019 TABLE 1—THERMAL RESISTANCE (R-Value)1 Thickness(Inch) .. R-Value(°F.ft2.h/Btu)_ 1.0 7.0 2.0 14. 3.0- 21 3.5 24.5. 4.0 . 28 5.0 35 5:5 38.5 6:0 42 7.0 49 8.0 56 9.0 63 10.0 70 11.0 77 12.0 84 For SI: 1 inch=25.4 mm;1 °F•ft2•hr/Btu=0:176110 °K•m2.hr/W. 1R-values are calculated based on tested k-factors at 1-and.4-inch thicknesses TABLE 2: ALTERNATE ASSEMBLIES WITHOUT A PRESCRIPTIVE THERMAL BARRIER1,2 Coating Max.Insulation . Max.Insulation Dry Film . Wet Film Application Rate1 Thickness Thickness Thickness . . .. . Thickness (theoretical) Overhead Vertical Surfaces (nominal) Surfaces JM TC(aka 11.5-in. 7.5 in. 12 mils 18 mils` 86 ft2/gal FIRESHELL® 292 mm. 191 mm 0.30 mm 0.46 mm 2.11 m2/L DC315 •11.5 inches . 7.5 inches 9 mils 14 mils : 115 ft2/gal 292 mm 191 mm 0.23 mm . 0.36 mm . . 2.82 m2/L Plus ThB 8 inches 6 inches 9 mils • 14 mils 115 ft2/gal 203 mm 152 mm 0.23 mm 0.36 mm 2.82 m2/gal ?Theoretical coating application rates are based strictly on minimum wet film thickness requirements:and shall be increased for site-specific conditions such as foam plastic surface texture,overspray loss, container and other residues, application technique and environmental conditions. 2 The coatings shall be applied in accordance with the Product Data Sheet and this report in such a manner that the foam plastic is not exposed. Page 6 of 9 4144 EVALUATION REPORT Number x. 146 TM Originally Issued:. 07/31/2015 Revised: 12/11/2018 Valid Through: 07/31/2019 TABLE 3: NFPA 285 COMPLYING WALL ASSEMBLIES WITH JM CORBOND III IN WALL CAVITY WALL COMPONENTS MATERIALS': Base Wall System1 1. Concrete wall (Use either 1,2 or 3) 2. Concrete masonry wall 3. 1 layer of 5/8-inch thick Type X gypsum wallboard installed on the interior side of minimum 35/s-inch deep,minimum 25-gauge equivalent.thick steel studs spaced a maximum of 24 inches on center. Lateral bracing installed minimum every 4 feet vertically or as required. Wall stud cavities shall be filled at each floor line with minimum 4 lb/ft3 mineral wool (e.g. JM MinWool®Safing)friction fit between steel wall studs. Perimeter Fire Barrier System Perimeter fire barrier system complying with Section 7.15.4 of the.2015 IBC shall be installed, as applicable,to fill the void between the edge of the concrete floor slab and the interior surface of the exterior wall assembly(see note 1). ' Interior Insulation ' 1. None (Use either 1,2,3,4,5 or 6 2: Maximum 35/8 inch thickness of Corbond Ill CC SPF applied to interior surface of Base Wall System 1 and 2(See Note 1). 3. Full wall stud cavity•depth or less of Corbond III CC SPF applied using exterior gypsum sheathing of.Base Wall System 3 as the substrate and covering the width of the cavity and the inside of the steel wall stud framing flange. 4. Fiberglass batt insulation (faced or unfaced) 5. Mineral wool insulation (faced or unfaced) 6. Hybrid Systems:spray foam and/or fiberglass insulation or mineral wool insulation (flash and bat insulation systems) Exterior•sheathing . ' . 5/s-inch thick Type X exterior gypsum sheathing.(for Base Wall System 3 above) . Exterior Wall Covering2 ' Any non-combustible exterior wall covering material using any standard installation technique. . Window Closure• Minimum 0.08-inch thick aluminum;or equivalent Flashing of window,door and other As an option, flash around window, door and other exterior penetrations with limited exterior wall penetrations amounts of.maximum 12-inch wide flashing tape (acrylic, asphalt or butyl-based)or liquid applied membrane material with or without fiber mesh reinforcement. For SI:1 inch=25.4 mm;1.0 pcf=16 kg/m3 Notes: 1 Fireblocking per IBC Section 718(2009.IBC Section 717)and thermal barrier material requirements must be met for Base Wall Systems land 2,as required by specific wall construction details when combustible concealed space is created on interior side of exterior wall assembly. 2 Non-combustible exterior wall coverings shall be installed in accordance with manufacturer's installation requirements. Page 7 of 9 • 11111k/H EVALUATION REPORT Number F}'-4 - 146 'TM Originally Issued: 07/31/2015 Revised: 12/11/2018 Valid Through: 07/31/2019 TABLE E 4: NFPA 285 COMPLYING WALL ASSEMBLIES WITH CORBOND III INSTALLED ON THE EXTERIOR WALL COMPONENTS MATERIALS Base Wall System' 1. Concrete wall (Use either 1, 2 or 3) 2. Concrete masonry wall 3. 1 layer of 5/8-inch thick Type X gypsum wallboard installed on the interior side of minimum 35/8-inch deep, minimum 25-gauge equivalent thick steel studs spaced a maximum of 24.inches on center. Lateral bracing installed minimum every.4 feet vertically or as required.. Wall stud cavities shall be filled at each floor line with minimum 4 lb/ft3 mineral wool (e.g. JM MinWool®Safing)friction fit between steel wall studs. Perimeter Fire Barrier System Perimeter fire barrier system complying with Section 715.4 of the 2015 IBC shall'be installed,as applicable;to fill the void between the edge of the concrete floor slab and the interior surface of the exterior wall assembly(see note 1). Interior Insulation 1. 'None ' (Use either 1,2,3,4,5 or 6 2. Maximum 35/8-inch thickness of Corbond III CC SPF applied to interior surface of Base Wall System 1 and 2(See Note 2). 3. Full wall stud cavity depth or less of Corbond III CC SPF applied using exterior gypsum sheathing of Base Wall System 3 as the substrate and covering the width of the cavity ad the inside of the steel wall stud framing flange. 4. 'Fiberglass batt insulation (faced or unfaced) 5. Mineral wool insulation(faced or unfaced) 6. Hybrid Systems:spray foam and/or fiberglass insulation or mineral wool insulation (flash and bat insulation systems) Exterior Sheathing 1. None(for Base Wall Systems 1 or above) . (Use either1, 2 or3) 2. 1/2-inch thick glass mat exterior gypsum sheathing complying with ASTM C1177 • (for Base Wall System 3 above) 3.. 5/8-inch thick Type X exterior gypsum sheathing(for Base Wall System 3 above) Exterior Insulation' .. Maximum 3%-inch thickness of Corbond III CC SPF ' Exterior Wall Covering 1. Brick—Standard type brick veneer anchors,installed a maximum of 24 inches on (Use either 1, 2, 3,4 or 5) center, vertically on each stud with maximum 1-inch air gap between exterior insulation and brick. Brick to be standard nominal 4-inch thck clay brick installed in:a running bond pattern using Type.S mortar: . 2. Stucco- Minimum 3/4-inch thick, exterior cement plaster and lath. A secondary water-resistive barrier(WRB)can be installed between the exterior insulation and the lath. The secondary WRB shall not be full-coverage asphalt or butyl-based self-adhered membranes. 3. Minimum 2-inch thick natural stone(granite, limestone, marble,sandstone). Any standard non-open jointed installation technique can be used. 4. Minimum 1%-inch thick concrete masonry unit (CMU), precast concrete, or artificial cast stone. Any standard non-open jointed,installation technique can be used. 5. Minimum 11/4-inch thick Terra Cotta non-opened jointed. Any standard non-open jointed installation technique can be used. Window Closure Minimum 1-gauge steel flashing, or equivalent . ' Flashing of window, door and other As an .option, flash around window,' door and other exterior penetrations with limited exterior wall penetrations amounts of maximum 12-inch wide flashing tape,(acrylic, asphalt or butyl-based)or liquid applied membrane material with or without fiber mesh reinforcement. For SI: 1 inch=25.4 mm; 1.0 pcf=16 kg/m3 Notes: 1 Fireblocking per IBC Section 718 (2009.IBC Section 717)and thermal barrier material requirements must be met for Base Wall Systems 1 and 2,as required by specific wall construction details when combustible concealed space is created on interior side of exterior wall assembly. Page 8 of 9 ilktt EVALUATION REPORT Number w 146 TM Originally Issued:. 07/31/2015 Revised: 12/11/2018 Valid Through: 07/31/2019 TABLE 5: ALTERNATE IGNITION:BARRIERS Coating/Cover Max:Insulation . Max.Insulation Dry Film Wet Film Application Rate. Thickness Thickness .. Thickness Thickness (nominal) Overhead Vertical Surfaces. (nominal) . . Surfaces . JM IC Ignition 51/2inches 3%.inches 3 mils, . . 4 mils .345 ft?/gal Barrier Coating 140 mm 89 mm • . 0.08 mm 0.1 mm_ 8.3 m2 LL (aka Fireshell®1B4) JM Spider® 10 inches 8 inches 2.5 inches NA NA_ 254 mm 203 mm . • . 64 mm . Notes: NA=Not Applicable Page 9 of 9 Johns Manville JM C O R D O N D® A Berkshire Hathaway Company INSULATION CERTIFICATE -723--��t This form MUST BE filled out and posted to comply with building code requirements. Meets IRC Sections rerequirements: 2009 IRC: N1101.2, N1101.4, N1101.8 2012 IRC: N1101.3, N1101.5, N1101.7, N1101.12 2015 IRC: N1 101.3., N1 101.4, N1 101.7, N1 101.10 The following spray applied polyurethane foam product(s) have been installed: n JM Corbond oc SPF 0.5 Ib/ft3 ICC ES ESR-3776 I CCRR-1079 JM Corbond ocx SPF 0.5 lb/ft3 UES ER-372 0 JM Corbond III 2.0 lb/ft3 UES ER-0146 In accordance with the 2015:International Building Code, Chapter 26, and the 2015. International Residential Code, R316, requirements for the foam plastics the insulation system(s) referenced above have been installed according to manufacturers' recommendations and to local building code requirements. For additional recommendations refer to ICC ES ESR-3776 or CCRR-1079for JM Corbond oc SPF, IAPMO UES. ER-372 for JM Corbond ocx SPF, and IAPM0 UES ER-0146 for JM Corbond III. The following thermal resistance values have been.installed: AREA INSULATED R-Value. Thickness (inches) Attic Area 38/Above Garage 5.5"CC Sloped Ceilings 38 2.occ/6.5"oc Walls 21 5.5"OC Floors 30 8.0"OC Basement Walls 20 5.25"Other Garage Walls 21 3.0"CC Other Rim Joists. 23 3.25"CC * Nominal thicknesses are representative of field spray-applied foam material Job-site Address: 17 Cliff Hollow Rd.Lake George,NY /Kelly Residence Building Contractor: CGM Construction Inc. Insulation Contractor: Advanced sprayfoarn Inc. Insulation Contractor Phone: 518.309.5141 Installed By: Date of Installation: 06/2019 DO NOT REMOVE THIS CERTIFICATE PLEASE POST NEAR ELECTRICAL PANEL For additional information: Q ww M.com fl 800.654.3103 BID-328 12/18 ©2018 Johns Manville.All Rights Reserved,717 17th Street,Denver,CO 80202