BINS-000934-2019 02142019INSPECTION WORKSHEET (BINS-000934-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:CC-0801-2018 Case Module:Permit
Inspection Date:Thu Feb 14, 2019 Inspection Status:Partial Pass
Inspector:John O'Brien Inspection Type:Building Insulation
Job Address:Parcel Number:643 GLEN ST
Queensbury, NY 12804
302.11-1-2
Contact Type Company Name Name
Contractor All Pro Restoration
Primary Owner Jacobs, John
Applicant All Pro Restoration
Tenant Inside Edge
Granted Permission Inside Edge
Architect Yasenchak, George
Checklist Item Passed Comments
Building Inspector Notes NO 2/14/19 Insulation Partial Approval
Ceiling R30
Walls R15
Remaining Item:
- Kraft papered Insulation above proposed suspended ceiling
needs to be covered with FSK25 foil paper. Slit the kraft
paper so a double vapor barrier is not created.
Window Sealing NO
U Factors = .3 cfm for windows, .5 cfm for doors NO
Proper Vent, Attic Vent NO
Feb 14, 2019 Page (1)
INSPECTION WORKSHEET (BINS-000934-2019)
Checklist Item Passed Comments
Insulation Residential Check Commercial Check NO 2/14/19 Insulation Partial Approval
Ceiling R30
Walls R15
Remaining Item:
- Kraft papered Insulation above proposed suspended ceiling
needs to be covered with FSK25 foil paper. Slit the kraft
paper so a double vapor barrier is not created.
Feb 14, 2019 Page (2)
O'Brien, John (Inspector)