Loading...
BINS-000934-2019 02142019INSPECTION WORKSHEET (BINS-000934-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:CC-0801-2018 Case Module:Permit Inspection Date:Thu Feb 14, 2019 Inspection Status:Partial Pass Inspector:John O'Brien Inspection Type:Building Insulation Job Address:Parcel Number:643 GLEN ST Queensbury, NY 12804 302.11-1-2 Contact Type Company Name Name Contractor All Pro Restoration Primary Owner Jacobs, John Applicant All Pro Restoration Tenant Inside Edge Granted Permission Inside Edge Architect Yasenchak, George Checklist Item Passed Comments Building Inspector Notes NO 2/14/19 Insulation Partial Approval Ceiling R30 Walls R15 Remaining Item: - Kraft papered Insulation above proposed suspended ceiling needs to be covered with FSK25 foil paper. Slit the kraft paper so a double vapor barrier is not created. Window Sealing NO U Factors = .3 cfm for windows, .5 cfm for doors NO Proper Vent, Attic Vent NO Feb 14, 2019 Page (1) INSPECTION WORKSHEET (BINS-000934-2019) Checklist Item Passed Comments Insulation Residential Check Commercial Check NO 2/14/19 Insulation Partial Approval Ceiling R30 Walls R15 Remaining Item: - Kraft papered Insulation above proposed suspended ceiling needs to be covered with FSK25 foil paper. Slit the kraft paper so a double vapor barrier is not created. Feb 14, 2019 Page (2) O'Brien, John (Inspector)