2009-164 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building& Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20090164 Application Number: A20090164
Tax Map No: 523400-226-012-0001-047-000-0000
Permission is hereby granted to: WALLACE & SUZANNA ALLERDICE
For property located at: 345 CLEVERDALE Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Type of Construction Value
Owner Address: WALLACE & SUZANNA ALLERD
150 ESCELSIOR Ave Boathouse $10,000.00
SARATOGA SPRINGS, NY 1286 Total value $10,000.00
Contractor or Builder's Name /Address Electrical Inspection Agency
Plans&Specifications
2009-164
498 SQ FT BOATHOUSE Sundeck with connector
$50.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Friday, July 09, 2010
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the Town of Queensbu , Thursday,July 09, 2009
' f
SIGNED BY I� f for the Town of Queensbury.
Director of Building&"eE rcement
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
4z Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF COMPLIANCE
Permit Number. P20090164 Date Issued: Tuesday, November 24, 2009
This is to certify that work requested to be done as shown by Permit Number P20090164
has been completed.
Tax Map Number. 523400-226-012-0001-047-000-0000
Location: 345 CLEVERDALE Rd
Owner. WALLACE & SUZANNA ALLERDICE
Applicant: WALLACE & SUZANNA ALLERDICE
This structure may be occupied as a:
Boathouse
By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Compliance DOES NOT relieve the
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
---_—,OFFICE USE ONLY ----.� �
TAX MAP NO. PERMIT N0. L5
� FEE PAID
BLDG.&CODES APPROVAL
---- ;
..........._-_...........
Y.
.1R _.�
ACCESSORY STRUCTURE BUILDING BUI�-DING & CO OES
Use this application for any structure other than thePrincipal
.I�IIIFL�UEF..IVSBk
not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure Nt
entitled Accessory Structures-Sheds/Fences. o. 3
A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE
ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS
RECEIVED A VALID BUILDING PERMIT.
OWNER:W.W. hl,grlmmp ----------
INSTALLER/BUILDER:
ADDRESS: /�
OCR,
3 ADDRESS:
PHONE NOS. 'Lrj1 ca - j7j1
PHONE NOS.
LOCATION OF PROPERTY: �if ��p
SUBDIVISION NAME:
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION:�O
ESTIMATED COST OF CONSTRUCTION$ �Q o
ANY OTHER ACCESSORY STRUCTURES ON PROPERTY?
IF YES,PLEASE LIST: 2-
C
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE:
PHONE:
------------
PROPOSED CONSTRUCTION 1'T FLOOR 2No FLOOR PROPOSED
SQ.FT. SQ.FT. TOTAL HEIGHT
SQ.FT.
OPEN PORCH FT.&IN.
DECK
3 SEASON,COVERED OR ENCLOSED PORCH'
r
BOATHOUSE
BOATHOUSE WITH SUNDECK
j2i 1p
DOCK
u
SHED
POLE BARN
DETACHED GARAGE(NO.OF CARS: )
OTHER ACCESSORY STRUCTURE:
"CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO) REQUIREMENTS IF THE
STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE.
To the best of my knowledge, the statements contained in the application, together with the plans
and specifications submitted, are a true and complete statement of all proposed work to be done
on the described premises and that all provisions of the Building Codes,
the Zoning Ordinance,
and all other laws pertaining to the proposed work shall be complied with, whether pecified or
noted, and that such work is authorized by the owner. Further, it is understood that I/we shall
submit prior to a Certificate Of Occupancy or Certificate of Compliance being issued, as requested
by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed
surveyor, drawn to scale, showing actual location of all new
construction.
I have read and agree to the above. QUESTIONS? CALL 761-8256 OR EMAIL
codesQgueensbury net
Signed f VISIT OUR WEBSITE FOR MORE INFORMATION
ated; 6 � www.aueensbury.net
Town of Queensbury- Community Development Office - 742 X' f� Bay Road, Queensbury, NY"12804
B 1-LGL 11-05
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518) 761-8256 Arrive: am/pm Depart: ` am/prn
Date Inspection request received: inspector's Initials:
NAME: �" �' ('� PERMIT#: � " l
LOCATION: DATE:
TYPE OF STR T R
Comments:
N A
4' Building Number Address visible from road
Chimney Height/V Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Co late/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs deckspatios more than 30 inches above grade,
Guard at stairwell at 34 inches or more
Guard at deckporches Winches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off exposed/regulator 18 inches above reds
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safetv alazing/Window in stairwells safety glazing-
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area:
Inter Connected: Baftery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access 1 sq.ft.-150 N.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emergency egress below grade
Gas Furnace shut-off within 30 feet or within line of site
Oil Fumace shut-off at entrance to furnace area
FumacelHot Water Heater operatin
Low water shut-off boiler
Relief Valves instal a I Water Temp 110
Enclosed Stairs Sheetrock Underside minimum W Gypsum
Basement stairs loosed rise>4 inches
Garage Floor Pitched
Garage fireproofing/%hour fire door/door closer
Duct work Sealed gMdy
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Are Fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Ins on Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10[Temporary/Permanent Ia
L16uilding&Codes Forms\Building&Codes\Inspection FormsWesidential Final Inspection Forrm_revised_100405.doc;Revised
January 7,2008;Revised 6/26/08
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received:
Queensbury Building&Code Enforcement Arrive: am/pm Depart:�am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: PERMIT#: v
LOCATION: INSPECT ON:
TYPE OF STRUC
Comments
Y N N/A
Footings
Piers *�
Monolithic Slab C�V «➢
Reinforcement in Place
The contractor is res nsible or
providing protection m fre ing
for 48 hours following the pl ment �_�i t7 A5
of the concrete. \ tl
Materials for this purpose on site. c , '
Foundation/Wallpour
f
Reinforcement in Place
Footing Dowels or Keyway in place
Foundation Dampproofmg
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Forms\Building&Codes\Inspection Farms\Foundation Inspection Report.doc