Loading...
RC-0803-2018 TOWN O QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518) 761-8201 Community Development - Building & Codes (518) 761-8256 C RTIFICAT OF OCCUPANCY Permit Number: RC-0803-2018 Date Issued: Wednesday, June 19, 2019 This is to certify that work requested to be done as shown by Permit Number RC-0803-2018 has been completed. Tax Map Number: 308.12-1-41 Location: 6 Wooden LN Owner: Michaels Group Homes, LLC Applicant: Michaels Group Homes, LLC This structure may be occupied as a: Single-Family Dwelling w/gas FP 1,939 sq Garage 493 sq. ft. By Order of Town Board Laric Development Lot 16 TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5904 (518)761-8201 Community Development- Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: RC-0803-2018 Tax Map No: 308.12-1-41 Permission is hereby granted to: Michaels Group Homes,LLC For property located at: 6 Wooden LN In the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance Type of Construction Owner Name: Michaels Group Homes,LLC Single Family-New $215,000.00 Owner Address: 1 Marions Way Total Value $215,000.00 Mechanicville,NY 12118 Contractor or Builder's Name/Address Electrical Inspection Agency Michaels Group Homes,LLC 1 Marions Way Mechanicville,NY 12118 Plans&Specifications Single-Family Dwelling w/gas FP 1,939 sq.ft. Garage 493 sq.ft. Laric Development Lot 16 $ 1,731.70 PERMIT FEE PAID -THIS PERMIT EXPIRES: Wednesday,January 8, 2020 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Queensbury; Tuesday,January 8,2019 SIGNED BY: �V , ? for the Town of Queensbury. Director of Building&Code Enforcement l/I IILC vac LJI Permit#:- C 503- ca I PRINCIPLE STRUCTURE PERMIT s 70 �i S • APPLICATION Permit Fee:$ pk.ts .1- 5 Town of CZeensbury * c"G l� 742 Bay Road,Queensbury,NY 12804 Rec Fee: $ P:518-761-8256 www.eiueensbury.net Invoice#:r'/tid Project Location: (a Tax Map ID #: •30`' I -t// Subdivision Name: *TOWN BD, RESOLUTION 86-2013: $850 recreation fee for new dwelling units: single family,duplexes/twe-facer; multiple family, apartments, condominiums,townhouses, and/or manufactured & modular homes, but notkmolaile homes. This Is In addition to the permit fee(s). , _a iL) CONTACT INFORMATION: \LI D[ Ec2s2;6 Lj • Applicant: T^'PIN OF 011t L SBURY Name(s): N�1C 1 -S Q s_ L.ILL 1 Y E,-=`'ELor MENT Mailing Address, C/S/Z: I MIGziziot,I.s W�'f M -> «Vt , N`r I2-1 ke) Cell Phone: ( 5» ) 89q • ka31 I Land Line: ( ) ti3h`t• (c t I Email: --1 R L t'it- -e Ml c-tA)=-1.s • Primary Owner(s): Name(s): • -4 /Nos 1 4= Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( Email: • Contractor(s): Business Name: SP+MX. AS 4f��C�I2 Contact Name(s): Mailing Address, C/S/Z: Cell Phone: ( ) Land Line: ( ) Email: • Architect(s)/Engineer(s): Business Name: K- . r-i , • Contact Name(s): Mailing Address, C/S/Z: Cell Phone: ( ) 'ern. Z402. Land Line: ( Email: k-f vac z4 cx. % e tJYCAtP.. R-2 Contact Person for Building & Code Compliance: To t.s-'cP4scao Cell Phone: ( s\c, ) 851•3144 Land Line: ( ) Email: T e M cc - Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 DECLARATION: 1. l acknowledge that no construction shall commence prior to issuance of a valid building permit and work will be completed within a 12 month period. 2. If the work is not completed by the 1 year expiration date the permit may be renewed, subject to fees and department approval. 3. I certify that the application, plans and supporting materials are a true and complete statement and/or description of the work proposed, that all work will be performed in accordance with the NYS Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. 4. I acknowledge that prior to occupying the facilities proposed I, or my agents, will obtain a certificate of occupancy. 5. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above: PRINT NAME: // 1-L " / 745c j u SIGNATURE: / DATE: / Z- -Z - • Town of Queensbury Building&Code Enforcement Principle Structure Application Revised February 2017 • Town ©f Queensbury Thomas R. Van Ness Highway Superintendent Highway Home (518) 745-0929 Department 742 Bay Road-Queensbury, NY 12801 David Duell Phone: (518) 761-8211 Deputy Highway Superintendent Fax: (518) 745-4466 Home (518) 743-0938 DRIVEWAY PERMIT DATE: 1z17cD I I ?) APPLICANT NAME: MICA-1ik ,S C{r k1::› LA-C. TELEPHONE NO.: 5t27..b=tc+.b311 ADDRESS TO BE INSPECTED: b �- =- RETURN ADDRESS: 1 Ntt kotivs 1.41p -r 1‘dl p.NtOitt.a.>✓d tiLY tZ%tQ, Applicant must show exact location and width of driveway(s) to be connected to the highway by placing stakes at the specified location. The Superintendent of Highways of the Town of Queensbury has reviewed this application. The following action has been taken: STEP 1: ( ) Preliminary Approval NEED: ( ) Slight swale ( ) Deep swale ( ) Level with the road ( ) Level with the top of the paved wing Size culvert pipe to be used (if necessary) ( ) 12" ( ) 15" ( ) 18" ( ) 24" ( ) 36" Preliminary inspection completed by: Date: Approval by Highway Supt: (or) Deputy Supt: Upon completion, please resubmit this approved permit for a final approval. STEP 2: ( ) Final Approval ( ) Rejected Date: Thomas R. Van Ness, Highway Superintendent David Duell, Deputy Highway Superintendent FUEL BURNING APPLIANCE & Office Use only CHIMNEY APPLICATION Permit#: F " C Permit Fee:$ t'o'"of Osicembury Invoice:#: 742 Bay Road,Queensbury, NY 12804 P: 518-761-8256 www.queensburv.net Project Location: ( 1�.�c�r�--� �-�'�-4=— Tax Map ID #: Room of Install: CA AT . Planned Install Date: T SO **ONE APPLICATION PER APPLIANCE** CONTACT INFORMATION: • Applicant: Name(s): M►act-f .S cozo, �-�-�- Mailing Address, C/S/Z: I r c 1,460e, T.,1,3a-Le.4,1.t<viu N./ an cis Cell Phone: ( ) Land Line: ( ) Email: J - %' •e. ctso4 • Primary Owner(s): Name(s): ��.1► - i� 1.� = Mailing Address, C/S/Z: Cell Phone:_( ) Land Line: _( ) Email: • Installer/Builder: Business Name: TT �� * PAn%O r'aN au-'�) Contact Name(s): c_crreci. 44,M4o 'K Mailing Address, C/S/Z: 176© Cell Phone: _( 5l45 ) 8149.14 Land Line: _( ) Email: Contact Person for Building & Code Compliance: 1t$. c" Lcx�sC4 Cell Phone: ( 5orb ) ci551 .3144 Land Line: ( Email: 'T t-ocbsc.ao ui.akG-1-sc,szeLP,GC154-3, Fuel Burning Appliance &Chimney Application Revised March 2017 • FUEL BURNING APPLIANCE INFORMATION: TYPE OF DEVICE: _Stove Fireplace Insert V .Fireplace _ Fuel Fired Equipment (Garage Only, 18" clearance per IMC 304.3) X Fireplace, factory built** **Manufacturer's name: 1-k - -I- C.rtc Model #: (uL--Sole;) SOURCE OF HEAT: Wood Coal Pellet >4 Gas CHIMNEY INFORMATION: Masonry: block brick stone Flue: _tie _steel size, in inches Material*: _double-wall _triple-wall insulated (*Manufacturer's name: Model#: ADDITIONAL INFORMATION: 1. Two inspections are required. A rough-in inspection, prior to installation and a final inspection, after installation. 2. Manufacturer's installation manual must be available at the time of inspection. 3. Masonry fireplaces & chimneys require plans to be submitted. 4. Twenty-four(24) hour notification is required for inspections. Declaration:Construction/installation must conform to NYS Fire Prevention & Building Code and/or manufacturer requirements. The applicant or owner agrees to comply with all applicable laws,ordinances, regulations and all conditions that are part of these requirements and also will allow the inspector to enter the premises to perform the required inspections. I have read and agree to the above: PRINT NAME: /1-L, SIGNATURE: X7'47 /LL DATE: j 2/4.-6/f Fuel Burning Appliance &Chim ey Application Revised March 2017 \</I'111411k\',4--c'-59 SEPTIC DISPOSAL PERMIT APPLICATION Office Use Only 742 Bay Road,Queensbury,NY 12804 Town of(Zy«f.hLir% P:518-761-8256 www.queensbury.net Permit#: F--C Tax Map ID#: Permit Fee: $ ; Invoice#: Project Location: (.=, Septic Variance? Yes No Primary Owner(s) MtcktD s c CozoiJ? ,U—c- Mailing Address 1 p,Ap c*s.S I f1b>`( t,,ls 1 tL•iuu3-, N—, IZl1it) Phone & Email 514?) C.c.-7=11 e, Mi 4-i SC15ies , c ut Installer/Builder GA-4 k‘reA cc Ni 'tuft Mailing Address 11 ;, , N.Y 222:ick Phone & Email "'"lte, ,"74 ,`13-i i Engineer �h-c� �lyG 1UCr Mailing Address 1ccPc l �p��u � G N N,Y i 4- Phone & Email 51g . Contact Person for Building&Code Compliance: 1 -`" \-C=C4tWA0 Phone: 51,e8 .87-51 RESIDENCE INFORMATION: Year Built #of bedrooms X gallons per bedroom =total daily flow Garbage Grinder Yes i 1980 or older Installed? (circle one) 1981-1991 Spa or Hot Tub Yes GO Installed? (circle one) 1992-Present . / 3 30 PARCEL INFORMATION: Topography }C Flat Rolling Steep Slope %Slope Soil Nature k Sand Loam Clay Other Groundwater At what depth? /V/,2 Bedrock/Impervious material At what depth? Domestic Water Supply Municipal _Well (if well,water supply from any septic system absorption is_ft.) Percolation Test Rate: per minute per inch (test to be completed by licensed engineer/architect) PROPOSED SYSTEM FOR NEW CONSTRUCTION: Tank size foe, gallons(min. size 1,000 gallons, add 250 gallons for each garbage cylinder or spa/hot tub System Absorption field with#2 stone Total length I To ft.; Each Trench ft. Seepage Pit with#3 stone How many: ;Size: Alternative System Bed or other type: Holding Tank System Total required capacity? ;tank size ;#of tanks NOTES: 1.Alarm system&associated electrical work must be inspected by a Town approved electrical inspection agency; 2.We will no longer allow systems to be covered until such time as an as-built plan is received and approved. The installed system must match the septic layout on file—no exceptions. Declaration:Any permit or approval granted which is based upon or is granted in reliance upon any material representation or failure to make a material fact or circumstance known by or on behalf of an applicant,shall be void. I have read the regulations and agree to abide by these and all requirements of the Town of Queensbury Sanitary Sewage Disposal Ordinance. PRINT NAME: 114- 1'ot J ' b Z4-- 4-16 DATE: l Ze. 7 a SIGNATURE: DATE: Town of Queensbury Building&Code Enforcement Revised February 2017 INSPECTION WORKSHEET (BINS-001676-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0803-2018 Case Module:Permit Inspection Date:Thu Mar 28, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Building Foundation Job Address:Parcel Number:6 Wooden LN Queensbury, NY 12804 308.12-1-41 Contact Type Company Name Name Architect Rupert, Keith Applicant Michaels Group Homes, LLC Primary Owner Michaels Group Homes, LLC Granted Permission Michaels Group Homes, LLC Contractor Michaels Group Homes, LLC Checklist Item Passed Comments Building Inspector Notes NO 3/28/19 damp-proofing approved Footings YES 3/21/19 footings approved Two rows of # 4 continues rebar Piers NO Monolithic Slab NO Reinforcement in Place NO Foundation / Wallpour YES Approved 3/26/19 Mar 28, 2019 Page (1) INSPECTION WORKSHEET (BINS-001676-2019) Checklist Item Passed Comments Reinforcement in Place YES 3/26/19 one row Tow Foundation Dampproofing YES 3/28/19 damp-proofing approved Foundation Waterproofing NO Footing Drain Daylight or Sump NO Footing Drain Stone - 12 inch width NO Footing Drain Stone - 6 inches above footing NO Footing Drain stone - 6 mil poly NO Backfill Approval NO Plumbing Under Slab NO PVC / Cast / Copper NO Foundation Insulation Interior / Exterior NO Rough Grade 6 inch drop within 10 ft.NO Poly Under Slab NO Mar 28, 2019 Page (2) Smith, Mark (Inspector) • ----:---1.. REScheck Software Version 4..6.5 �; g, c: E l Compliance Certificate . [LDEC262Q18 O'v_'•1 OF C"1,-. ETfNSB Project The Kimball ��OF Mo ,y'UhIi\ ° ' •\N 0 R U,c O Energy Code: 2015 IECC i ��> Location: Glens Falls, New YorkCi) ( I ;/ Co , Construction Type: Single-family * i � r U) Project Type: New Construction G !'lei A N co Orientation: Bldg. faces 0 deg. from North n�� : II 0) Conditioned Floor Area: 1,939 ft2 `FIj 06,6f fz O V Glazing Area 14% it_FE.,S\G�k\` O J CZ 0 Climate Zone: 6 (7635 HDD) i Permit Date: 18 December, 2018 ry. W A- Permit Number: %in. E •O J CO 01 Construction Site: Owner/Agent: Designer/Contractor: I 1....- a) 6 Wooden Lane Michaels Group Homes, LLC ?0 N— Queensbury, NY 12804 1 Marions Way N Mechanicville, NY 12118 _ U_ ' 0 = (I) N N r C CA Compliance: Passes using UA trade-off Cy CO CO Z Compliance: 1.0%Better Than Code Maximum UA: 299 Your UA: 296 '17 L m The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. 03 V a It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. M C r II- 6 r cn Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Foundation Wall: Solid Concrete or Masonry 1,247 0.0 19.0 0.039 48 Orientation: Left side Wall height: 7.6' Depth below grade: 6.6' Insulation depth: 7.6' lx 5030 Sliding Window: Vinyl Frame:Double Pane with Low-E 15 0.300 5 Orientation: Left side 2x Std. Basement Windows:Vinyl Frame:Double Pane with Low-E 4 0.300 1 Orientation: Left side 1st Floor Walls: Wood Frame, 24" o .c. 1,305 21.0 0.0 0.056 60 Orientation: Front Foyer#1: Solid 21 0.170 4 Orientation: Front 2x Home Office (0): Vinyl Frame:Double Pane with Low-E 36 0.300 11 Orientation: Front lx Stair(AC):Vinyl Frame:Double Pane with Low-E 4 0.300 1 Orientation: Front 2x Great Room (E): Vinyl Frame:Double Pane with Low-E 29 0.300 9 Orientation: Front lx Great Room (R): Vinyl Frame:Double Pane with Low-E 27 0.300 8 Orientation: Front 2x Dining (C): Vinyl Frame:Double Pane with Low-E 21 0.300 6 Orientation: Front lx Dining (H):Vinyl Frame:Double Pane with Low-E 33 0.300 10 Orientation: Front Project Title: The Kimball Report date: 12/18/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\6 Wooden Lane.rck Page 1 of10 A Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter #7 Dining: Glass 40 0.300 12 Orientation: Front lx Mud (AC): Vinyl Frame:Double Pane with Low-E 4 0.300 1 Orientation: Front Mud #20: Solid 19 0.170 3 Orientation: Front 2nd Floor Walls: Wood Frame, 24" o .c. 1,016 21.0 0.0 0.056 51 Orientation: Front 2x Bed #3 (AT): Vinyl Frame:Double Pane with Low-E 32 0.300 10 Orientation: Front lx Master Bed (G): Vinyl Frame:Double Pane with Low-E 32 0.300 10 Orientation: Front lx Master Bath (Q): Vinyl Frame:Double Pane with Low-E 12 0.300 4 Orientation: Front lx Master Bath (AC): Vinyl Frame:Double Pane with Low-E 4 0.300 1 Orientation: Front lx Main Bath (AC): Vinyl Frame:Double Pane with Low-E 4 0.300 1 Orientation: Front lx Bed #2 (AT): Vinyl Frame:Double Pane with Low-E 16 0.300 5 Orientation: Front lx Laundry (AS):Vinyl Frame:Double Pane with Low-E 10 0.300 3 Orientation: Front Ceiling: Raised or Energy Truss 1,111 38.0 0.0 0.025 28 Floor Above Garage: All-Wood Joist/Truss:Over Unconditioned Space 115 30.0 0.0 0.033 4 Laundry Floor Above Porch: All-Wood Joist/Truss:Over Outside Air 14 30.0 0.0 0.033 0 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building has b en design to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed n he RE eck Inspection Checklist. i' Name-Title / Signature Date Project Title: The Kimball Report date: 12/18/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\6 Wooden Lane.rck Page 2 of10 REScheck Software Version 4.6.5 Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.lD 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate ❑Does Not [PR1]1 energy code compliance for the ❑Not Observable building envelope.Thermal envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable t, Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods ❑Not Observable it,_, Manual Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 !Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/18/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\6 Wooden Lane.rck Page 3 of10 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [FO4]1 insulation R-value.Where interior R_ R- ❑Does Not table for values. insulation is used, verification may need to occur during ❑Not Observable Insulation Inspection. Not ENot Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [FO511 insulation installed per ❑Does Not manufacturer's instructions. • ['Not Observable ENot Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [FO6]1 insulation depth of burial or ❑Does Not table for values, •�. distance from top of wall. Not Observable :Not Applicable 303.2.1 A protective covering is installed ❑Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. ❑Not Observable ENot Applicable 403.9 Snow-and ice-melting system ❑Complies [FO12]2 controls installed. ❑Does Not ENot Observable ENot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/18/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\6 Wooden Lane.rck Page 4 of10 Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. (FR111 ❑Not Observable ❑Not Applicable i 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 ❑Not Observable [FR2)1 ENot Applicable 303.1.3 U-factors of fenestration products EComplies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable ❑Not Applicable 402.4.1.1 Air barrier and thermal barrier EComplies [FR23]1 installed per manufacturer's ❑Does Not instructions. ENot Observable ENot Applicable 402.4.3 Fenestration that is not site built EComplies [FR20]1 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/1.5.2/A440 or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ENot Applicable limits. 402.4.5 IC-rated recessed lighting fixtures EComplies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate <_2.0 cfm leakage at 75 Pa. :Not Observable :Not Applicable 403.3.1 Supply and return ducts in attics EComplies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter>= 3 inches and R-4.2 for< 3 inches in diameter. 403.3.5 Building cavities are not used as EComplies [FR15]3 ducts or plenums. ❑Does Not ❑Not Observable ENot Applicable 403.4 HVAC piping conveying fluids R- R- EComplies [FR1712 above 105°F or chilled fluids ❑Does Not below 55 °F are insulated to 3 ENot Observable ❑Not Applicable 403.4.1 Protection of insulation on HVAC EComplies [FR24]1 piping. ❑Does Not ENot Observable ENot Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >R-3. ❑Does Not 14.20- ❑Not Observable ENot Applicable 403.6 Automatic or gravity dampers are EComplies [FR1912 installed on all outdoor air ❑Does Not intakes and exhausts. ENot Observable ENot Applicable 1 High Impact(Tier 1) 12 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/18/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\6 Wooden Lane.rck Page 5 of10 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled Complies i[IN13]2 or the installed R-values EDoes Not provided. ENot Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood EDoes Not table for values. [IN1]1 ❑ Steel ❑ Steel ENot Observable t :Not Applicable 303.2, Floor insulation installed per EComplies 402.2.7 manufacturer's instructions and EDoes Not [IN2]1 in substantial contact with the underside of the subfloor, or floor ENot Observable framing cavity insulation is in :Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood EDoes Not table for values. 1402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ENot Observable i[IN3]1 exterior, the exterior insulation requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable i 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. EDoes Not 1 ENot Observable j ENot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 1 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/18/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\6 Wooden Lane.rck Page 7 of10 • Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, Wood ❑ Wood EDoes Not table for values. 402.2.2, Steel 402.2.E ❑ El Steel ['Not Observable [FI1]1 ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. EDoes Not (F12]1 Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [FI22]2 insulation include baffle adjacent EDoes Not to soffit and eave vents that extends over insulation. ❑Not Observable ENot Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]1 insulation >_R-value of the EDoes Not adjacent assembly. [Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = EComplies [F117]1 ach in Climate Zones 1-2, and EDoes Not <=3 ach in Climate Zones 3-8. ['Not Observable ❑Not Applicable 403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]1 cfm/100 ft2 across the system or ft2 ft2 EDoes Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests, verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI2711 determine air leakage with ft2 ft2 EDoes Not either: Rough-in test:Total leakage measured with a ['Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI24]1 by manufacturer at<=2%of EDoes Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI912 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI1012 on heat pumps. EDoes Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI1112 systems have automatic or EDoes Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 :Medium Impact(Tier 2) 3 I Low Impact(Tier 3) Project Title: The Kimball Report date: 12/18/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\6 Wooden Lane.rck Page 8 of10 Section ' Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID j j 403.6.1 All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. [Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat EComplies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water :Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems EComplies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ENot Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems EComplies [FI29]2 comply with IEEE 515.1 or UL ❑Does Not 515. Controls automatically adjust the energy input to the ['Not Observable heat tracing to maintain the ENot Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ['Not Observable water source through a cold ENot Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104°F. 403.5.4 Drain water heat recovery units EComplies [FI31]2 tested in accordance with CSA ❑Does Not B55.1. Potable water-side pressure loss of drain water heat ❑Not Observable recovery units< 3 psi for ❑Not Applicable individual units connected to one y�- ���' � or two showers.Potable water- side pressure loss of drain water heat recovery units< 2 psi for . individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI6]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ENot Applicable 404.1.1 Fuel gas lighting systems have EComplies [FI23]3 no continuous pilot light. ❑Does Not ❑Not Observable ENot Applicable 11 !High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/18/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\6 Wooden Lane.rck Page 9 of10 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 401.3 Compliance certificate posted. ❑Complies [F17]2 ❑Does Not ['Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [FI18]3 mechanical and water heating Does Not systems have been provided. []Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) —2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: The Kimball Report date: 12/18/18 Data filename: F:\Share\Design\Res-Check\Burnt Ridge\6 Wooden Lane.rck Page 10 of10 I i 0 20 IE Efficie15ncyCC Energy Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 19.00 Floor 30.00 Ceiling / Roof 38.00 Ductwork (unconditioned spaces): Glass &Door Rating U-Factor SHGC Window 0.30 0.28 Door 0.30 0.28 Heating&Cooling Equipment Efficiency Heating System:_ Cooling System: Water Heater: Name: Date: Comments 'n) r - II DEC 262018 11)) TGl%i(3C`± r ?i EN33URY 6 Wooden Ln Gc�3r�1�E��� � , I_�� ov��rsr HVAC Load Calculations for The Michaels Group mktpit _ _ RHVACRESIDENTIAL HVAC LOADS 308.12-1-41 RC-0803-2018 9 H MichaelsBurnt Group rs6LLC Hills Dr, SFD wigas FP 1939 sf., Gar 493 s.f. Prepared By: Wednesday, December 19,2018 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. .Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 6 Wooden Ln Schenectady,NY 12306 Page 2 Project Report General Project Information Project Title: 6 Wooden Ln Designed By: The Michaels Group Project Date: Wednesday, December 19, 2018 Client Name: The Michaels Group j Design Data Reference City: Schenectady, New York Building Orientation: Front door faces North Daily Temperature Range: Medium Latitude: 42 Degrees Elevation: 378 ft. Altitude Factor: 0.986 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 1 0.31 n/a n/a 70 n/a Summer: 87 72 49% 50% 75 30 tCheck Figures Total Building Supply CFM: 1,168 CFM Per Square ft.: 0.400 Square ft. of Room Area: 2,920 Square ft. Per Ton: '1,229 Volume(ft3)of Cond. Space: 24,856 -:Buildin Loads Total Heating Required Including Ventilation Air: 54,217 Btuh 54.217 MBH Total Sensible Gain: 25,352 Btuh 89 % Total Latent Gain: 3,149 Btuh 11 % Total Cooling Required Including Ventilation Air: 28,501 Btuh 2.38 Tons(Based On Sensible + Latent) Notes Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\6 Wooden Ln.rh9 Wednesday, December 19, 2018, 11:04 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc: j 6 Wooden Ln Schenectady,NY 12306 3r Page 3 [Miscellaneous Report System 1 Outdoor Outdoor Outdoor ,- a 'tc Input Data Dry Bulb Wet Bulb Rel.Hum Rit _,„ 0 _ i ®h ;i ere Winter: 1 0.31 80% n/a 70 n/a Summer: 87 72 49% 50% 75 29.96 Duct Sizing Inputs Main Trunk Runouts Calculate: Yes Yes Use Schedule: Yes Yes Roughness Factor: 0.00300 0.01000 Pressure Drop: 0.1000 in.wg./100 ft. 0.1000 in.wg./100 ft. Minimum Velocity: 650 ft./min 450 ft./min Maximum Velocity: 900 ft./min 750 ft./min Minimum Height: 0 in. 0 in. Maximum Height: 0 in. 0 in. { utstdAir Data A Winter Summer Infiltration Specified: 0.410 AC/hr 0.210 AC/hr 170 CFM 87 CFM Infiltration Actual: 0.410 AC/hr 0.210 AC/hr Above Grade Volume: X 24,856 Cu.ft. X 24,856 Cu.ft. 10,191 Cu.ft./hr 5,220 Cu.'ft./hr X 0.0167 X 0.0167 Total Building Infiltration: 170 CFM 87 CFM Total Building Ventilation: 0 CFM 0 CFM ---System 1--- Infiltration &Ventilation Sensible Gain Multiplier: 13.02 = (1.10 X 0.986 X 12.00 Summer Temp. Difference) Infiltration &Ventilation Latent Gain Multiplier: 20.09 = (0.68 X 0.986 X 29.96 Grains Difference) Infiltration &Ventilation Sensible Loss Multiplier: 74.87 = (1.10 X 0.986 X 69.00 Winter Temp. Difference) Winter Infiltration Specified: 0.410 AC/hr(170 CFM), Construction: Average Summer Infiltration Specified: 0.210 AC/hr(87 CFM), Construction: Average C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\6 Wooden Ln.rh9 Wednesday, December 19, 2018, 11:04 AM 'Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 6 Wooden Ln Schenectady,NY 12306 Page 4 Load Preview Report Net ft. Sen Latl Net Sen' Sys Cls ASo Duct Scope Ton /To Area Gain Gair Gair Loss Size CFM CFM CFM Building 2.38 1,229 2,920 25,352 3,149 28,501 54,217 714 1,168 1,168 System 1 2.38 1,229 2,920 25,352 3,149 28,501 54,217 714 1,168 1,168 12x17 Zone 1 2,920 25,352 3,149 28,501 54,217 714 1,168 1,168 12x1i 1-Basement 1,005 2,040 506 2,546 12,293 162 94 94 1--6 2-Dining 132 2,151 160 2,311 5230 69 99 99 1--6 3-Kitchen 160 909 80 989 2,491 33 42 42 1-4 4-Mud Room 49 1,073 66 1,139 1,623 21 49 49 1--4 5-Powder Room 30 457 0 457 248 3 21 21 1--4 6-Great Room 316 2.602 193 2,795 6,479 85 120 120 2-4 7-Foyer 96 1,103 94 1,197 2,412 32 51 51 1--4 8-Office 160 2,091 119 2,210 3,754 49 96 96 1-6 9-Master Bath 103 1.379 85 1,464 2,677 35 64 64 1-5 10-WIC 55 660 0 660 522 7 30 30 1-4 11-Master Bedroom 272 3,454 863 4,317 5,716 75 159 159 2-5 12-Bath 1 58 846 25 871 1,050 14 39 39 1--4 13-Bedroom 2 142 2,153 450 2,603 3,197 42 99 99 1-6 14-Laundry 64 1,147 54 1,201 1,687 22 53 53 1--4 15-Bedroom 3 153 2,446 454 2,900 3,654 48 113 113 2-4 16-LoftlHali 125 840 0 840 1,184 16 39 39 1-4 ii C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\6 Wooden Ln.rh9 Wednesday, December 19, 2018, 11:04 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. Ilit 6 Wooden Ln Schenectady,NY 12306 Page 5 Duct Size Preview Room or Minimum Maximum Rough Desig SP1 Duci Duc Htg Gig Act. Duct Duct Name Source Veloci VelocityFacto L/10q Loss) Velocit Len tF� 9 Flow Flow Flow Size System 1 Supply Runouts Zone 1 1-Basement Built-In 450 750 0 0.1 478.7 162 94 1-6 2-Dining Built-In 450 750 0 0.1 504.8 69 = 99 1-6 3-Kitchen Built-In 450 750 0 0.1 480 33 , 42 1-4 4-Mud Room Built-In 450 750 0 0.1 566.7 21 _! 49 1-4 5-Powder Room Built-In 450 750 0 0.1 241.3 3 !I 21 1-4 6-Great Room Built-In 450 750 0 0.1 686.9 85 F2 120 2-4 7-Foyer Built-In 450 750 0 0.1 582.7 32 ,i 51 1-4 8-Office Built-In 450 750 0 0.1 490.7 49. 4 ; 96 1-6 9-Master Bath Built-In 450 750 0 0.1 466.1 35 f 64 1-5 10-WIC Built-In 450 750 0 0.1 348.7 7 r 30 1-4 11-Master Bedroom Built-In 450 750 0 0.1 583.7 75 Fa;' 159 2-5 12-Bath 1 Built-In 450 750 0 0.1 446.9 14 39 1-4 13-Bedroom 2 Built-In 450 750 0 0.1 505.3 42 J 99 1-6 14-Laundry Built-In 450 750 0 0.1 605.6 22 4 53 1-4 15-Bedroom 3 Built-In 450 750 0 0.1 645.8 48 113 2-4 16-Loft/Hall Built-In 450 750 0 0.1 443.7 16 ` 39 1-4 Other Ducts in System 1 Supply Main Trunk Built-In 650 900 0 0.1 824.6 714 L 1,168 12x17 Summary System 1 Heating Flow: 714 Cooling Flow: 1168 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\6 Wooden Ln.rh9 Wednesday, December 19, 2018, 11:04 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc. 6 Wooden Ln Schenectady,NY 12306 Page Total Building Summary Loads Component Area Ser Let aDescription Quan -LOSS, ,Gain jug Pella Vinyl: Glazing-Pella Vinyl, u-value 0.31, SHGC 0.28 277 5,928 0 3,438 3,438 Pella Slider: Door-Pella Slider 40.8 845 0 282 282 Therma Tru 90 Min: Door-Therma Tru 90 Min 20.4 197 0 66 66 Front Door: Door-Front Door Generic 21.8 285 0 95 95 12E-0bm: Wall-Frame, R-19 insulation in 2 x 6 stud 968 6,880 0 838 838 cavity, no board insulation, brick finish, metal studs 12F-0sw: Wall-Frame, R-21 insulation in 2 x 6 stud 2016.9 9,047 0 1,612 1,612 cavity, no board insulation, siding finish, wood studs 16B-38: Roof/Ceiling-Under Attic with Insulation on Attic 973.3 1,745 0 1,188 1,188 Floor(also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Asphalt Shingles or Dark Metal, Tar and Gravel or Membrane, R-38 insulation 21A-24: Floor-Basement, Concrete slab, any thickness, 2 1004.9 1,733 0 0 0 or more feet below grade, no insulation below floor, any floor cover, shortest side of floor slab is 24'wide 19A-0cp: Floor-Over enclosed unconditioned crawl 1611.7 12,325 0 2,145 2,145 space, No insulation on exposed walls, sealed or vented space, passive, no floor insulation, carpet or 1 hardwood i', 19A-0tp: Floor-Over enclosed unconditioned crawl space, 304,6 2,517 0 437 437 No insulation on exposed walls, sealed or vented space, passive, no floor insulation, tile or vinyl Subtotals for structure: 41,502 0 10,101 10,101 j People: 4 1,400 1,800 3,200 Equipment: 0 0 0 - Lighting: 3535 12,054 12,054 Ductwork: 0 0 0 0 _ Infiltration: Winter CFM: 170, Summer CFM: 87 12,715 1,749 1,133 2,882 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: 0 0 263 263 I, Total Building Load Totals: 54,217 3,149 25,352 28,501 r t roheckFidures _ Total Building Supply CFM: 1,168 CFM Per Square ft.: 0.400 44 Square ft. of Room Area: 2,920 Square ft. Per Ton: 1,229 Volume(ft')of Cond. Space: 24,856 B Ilding Loads _ Total Heating Required Including Ventilation Air: 54,217 Btuh 54.217 MBH Total Sensible Gain: 25,352 Btuh 89 % Total Latent Gain: 3,149 Btuh 11 % Total Cooling Required Including Ventilation Air: 28,501 Btuh 2.38 Tons (Based On Sensible+ Latent) Notes _ ' Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. x t i ,- 11 C:\Users\nicka\Documents\Elite Software\Rhvac 9 Projects\6 Wooden Ln.rh9 Wednesday, December 19, 2018, 11:04 AM Rhvac-Residential&Light Commercial HVAC Loads Elite Software Development,Inc. Appolo Heating Inc, 6 Wooden Ln Schenectady,NY 12306 Page 24, System 1 Room Load Summary Htg " Min Run Run Clg Clg Min Act Room Area Sens Htg Duct Duct Sens Lat Gig Sys No Name SF Btuh CFM Size Vel Btuh Btuh. CFM;. CFM ---Zone 1--- 1 Basement 1,005 12,293 162 1-6 479 2,040 506 94 94 2 Dining 132 5,230 69 1-6 505 2,151 160 99 99 3 Kitchen 160 2,491 33 1-4 480 909 80 42 42 4 Mud Room 49 1,623 21 1-4 567 1,073 66 49 49 5 Powder Room 30 248 3 1-4 241 457 0 21 21 6 Great Room 316 6,479 85 2-4 687 2,602 193 120 120 7 Foyer 96 2,412 32 1-4 583 1,103 94 51 51 8 Office 160 3,754 49 1-6 491 2,091 119 96 96 9 Master Bath 103 2,677 35 1-5 466 1,379 85 64 64 10 WIC 55 522 7 1-4 349 660 0 30 30 11 Master Bedroom 272 5,716 75 2-5 584 3,454 863 159 159 12 Bath 1 58 1,050 14 1-4 447 846 25 39 39 13 Bedroom 2 142 3,197 42 1-6 505 2,153 450 99 99 14 Laundry 64 1,687 22 1-4 606 1,147 54 53 53 15 Bedroom 3 153 3,654 48 2-4 646 2,446 454 113 113 16 Loft/Hall 125 1,184 16 1-4 444 840 0 39 39 System 1 total 2,920 54,217 714 25,352 3,149 1,168 1,168 System 1 Main Trunk Size: 12x17 in. Velocity: 825 ft./min Loss per 100 ft.: 0.097 in.wg Cooling System Summary - ^ Cooling Sensible/Latent Sensible Latent Total Tons Split Btuh Btuh Btuh Net Required: 2.38 89%/ 11% 25,352 3,149 28,501 Actual: 2.92 75%/25% 26,250 8,750 35,000 • [Equipment Data Heating System Cooling System Type: Natural Gas Furnace Standard Air Conditioner Model: ML195UH070XP36B-* 13ACXN036-230** Indoor Model: C35-36B+TDR+TXV Brand: MERIT 90 MERIT 13ACX SERIES Description: Natural Gas or Propane Furnace Efficiency: 95 AFUE 13 SEER Sound: 0 0 Capacity: 64,000 Btuh 35,000 Btuh Sensible Capacity: n/a 26,250 Btuh Latent Capacity: n/a 8,750 Btuh AHRI Reference No.: n/a 8269490 9 Projects\6 Wooden Ln.rh9 Wednesday, December 19, 2018, 11:04 AM C:\Users\nicka\Documents\Elite Software\Rhvacof INSPECTION WORKSHEET (BINS-002349-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:RC-0803-2018 Case Module:Permit Inspection Date:Wed May 1, 2019 Inspection Status:Partial Pass Inspector:Mark Smith Inspection Type:Building Framing Job Address:Parcel Number:6 Wooden LN Queensbury, NY 12804 308.12-1-41 Contact Type Company Name Name Architect Rupert, Keith Contractor Michaels Group Homes, LLC Granted Permission Michaels Group Homes, LLC Applicant Michaels Group Homes, LLC Primary Owner Michaels Group Homes, LLC Checklist Item Passed Comments Building Inspector Notes NO 5/1/19 ice and water shield approved Framing NO Attic Access 22 x 30 minimum NO Jack Studs Headers NO Continuous Header for Garage Doors with Straping NO Truss Specification Provided NO May 01, 2019 Page (1) INSPECTION WORKSHEET (BINS-002349-2019) Checklist Item Passed Comments Bracing Bridging NO Hurricane Clips/Uplift Screws/Nail Holes Filled NO Air Seal all Plates and Sills NO Air Seal All Registers at Floor NO Air Sealing all Joints Before Insulation NO Joist hangers NO Jack Posts Main Beams NO Exterior sheeting nailed properly NO 12 O.C.NO Headroom 6 ft. 8 in.NO Notches Holes Bearing Walls NO Metal Strapping for Notches Top Plate NO Anchor Bolts 6 ft. or less on center NO Ice and water shield 24 inches from wall YES 5/1/19 ice and water shield approved Soffits-Insulation Baffel NO Windows Habitable Space Bedrooms NO May 01, 2019 Page (2) INSPECTION WORKSHEET (BINS-002349-2019) Checklist Item Passed Comments 24 in. (H)NO 20 in. (W)NO 5.7 sf above below grade NO 5.0 sf grade NO Design Professional Sign-off, if required NO May 01, 2019 Page (3) Smith, Mark (Inspector) MAP REFERENCE: LOT 28 MAP OF PROPOSED SUBDIVISION MADE FOR LARIC DEVELOPMENT, LLC �e DATED:APRIL 10, 2003 LAST REVISED:JANUARY 4, 2014 LOT 29 W BY: VAN DUSEN& STEVES FILED:MARCH 3, 2014, PLAT C-349 LOT 30 NOTES: 1. SURVEYED PARCEL IS SUBJECT TO EASEMENTS AND COVENANTS OF RECORD. W ,v wv �v 2. OFFSETS BETWEEN STRUCTURES A ,� cable Peclesta� AND PROPERTY LINES ARE TO DISPLAY v Electric Box THE RELATIONSHIP BETWEEN ,h IMPROVEMENTS AND ARE FOR THE V' SOLE PURPOSE OF INTERPRETING AS BUILT THEIR CONFORMANCE WITH ZONING AND NOT INTENDED TO AID IN THE ° ESTABLISHMENT OR RETRACEMENT OF ® OP 66 - '1 PROPERTY LINES. O \ \ ' � 1 23.5'± LOT 17E C G� 40.0 �, GF,I'I \ -- \� N 3.d - rS cb UN 13 201 n`'4 0 1250 GAL. � t�T wv `° SEPTIC TANK "OWN OF QUEEN BURY as O1 er '± � BUILDING&CODES c3�, e Electric Meter � AFca� 54.0'± _ LOT 11 L44,17' �` ��"°J�e O \ -- R25.00' BN 13°3#V 22'° E 18.51± Chord Length 38.64' 30.0'± DISTRIBUTION BOX '?►� 12 '± LOT 16 ABSORPTION TRENCHES Area 4 @ 50 EA, 57723. 7± Sq. Feet 1.33± Acres 6 LEGEND: 50�_ W °®g 2 8262 0®4`34 41.14 S 15 = WATER SHUT-OFF N 2®rd Length �wv = WATER VALVE 12 Ch 1 H = HYDRANT i LOT 15 I SEPTIC SYSTEM - AS BUILT BY NACE ENGINEERING ( V�00&'Y-) 'l ) Q ?r- ®ate: May 24, 2019 DbNA1J1HOR1ZCD ALI_[RATiON OR ADDITION TO A 5URVLY 1"—4 MAP BEARING A UCEN5ED LAND 5URV"CYOR_ Scale:5CAL 15A Map of a Survey made for 0 VIOLATION OF 51C7ION 7200,5Ub-DIV151ON 2,OF THE NEW YORK 5TATC EDUCATION LAW." Ste -veS ,.ONLYONLY COPIES FROM L O OFTHIS SURVEY MARKED WITH AN ORIGINAL AL OFf THE THE LAND SURVEYORS SEAL 511ALL BE CON5I0CRED TO DE VALID TRUE COPIES." rS- 1 Hi5 5 JKVFYON5 INDICATED IN SIGNIFY THAT Amy Leigh Liles HIS SURVf_Y WAS PREPARED IN ACCORDAhSCL'WI"fry THE Larid EXISTING CODE OF PRACTICC FOR LAND SURVEYORS IONAI D BY TI1C NEW YORK STATE A550c.(ATION Of PROFE5510NAL LAND 50RVCYOR5.SAID CCRTIFICATION5 SHALL RUN ONLY TO THE PCR50N FOR WHOM THC 51JRVI_Y 15 PREPARED,AND ON H75 BCIIALF TO THE TITLE COMPANY,GOVCRNMENI"AI- SHEET 1 OF 1 AGENCY AND LENDINGINSTITUTIONU5'I"CDHCRCON,AND Town of Queensbury, Warren County, New York - 169 Haviland Road Queensbury, New York 12804 1-0 THE A551GNLL5Of THE[ENDING IN5TITUTION." Mlchael5 Group homes (518) 792-8474 New York Lie. No. 50135 NO. DATE DESCRIPTION DWG. NO. 99-24 P Lot i IS 308.12-1-41 Testing Company: Name:LoCascio Energy Solutions Address:20 Ogden Rd. Queensbury , NEW YORK 12804 Phone: 5188573144 Technician: Name:Anthony LoCascio Credentials:HERS Rater#4242961 Email:tony@energysolutions.com Building Information: Project ID:6 Wooden Address:6 Wooden Lane Queensbury, NY 12804 Geo-Tag Data:Latitude: 43.303249 Longitude: -73.696267 Timestamp: 2019-06-14 14:14:47 Customer Information: Name:Michaels Group Homes Address:1 Marions Way Mechanicville, NY 12118 Measured Leakage:1,073.3 CFM50 Test ID:6 wooden Purpose of Test:RESNET Multi-Pt Env. Leakage Measured ACH50:2.68 (+/- 8.4%)Effective Leakage Area: 46.7 in² Building Volume:24,072.0 ft³Enclosure Surface Area: 0.0 ft² Flow Coefficient (C):58.8 (+/- 42.9%)Exponent (n): 0.743 (+/- 0.122) Correlation Coefficient:0.99602 Test Standard:RESNET 380 Multi-Point Test Mode: Depressurize Test Characteristics:Indoor Temp: 68 °F Altitude: 381.0 ft Outdoor Temp: 65 °F Time Average Period: 10 seconds Test Date and Time:2019-06-14 14:15:01 Envelope Leakage Test Test Readings: Target (Pa)Bldg (Pa)Adj Bldg (Pa)Fan (Pa)Flow (cfm)Config Baseline 0.6 -60.0 -60.0 -60.6 -45.7 1,225.8 Ring A -48.0 -46.4 -47.0 -35.3 1,080.7 Ring A -35.0 -39.1 -39.7 -22.2 861.9 Ring A -23.0 -21.2 -21.8 -101.3 598.0 Ring B -10.0 -13.7 -14.3 -49.3 418.6 Ring B Test Equipment: Flow Device:Model 3 110V Fan Serial #: 3172 Pressure Gauge:DG1000 Serial #: 3172 Calibration Date: 2019-02-18 Deviations from Standard: None Comments: Envelope Leakage Test (Page 2) Report generated by TEC Auto Test version 1.5.1 (31), © 2019 by The Energy Conservatory, Inc.