Loading...
2009-188 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090188 Application Number. A20090188 Tax Map No: 523400-308-008-0001-057-000-0000 Permission is hereby granted to: BRIAN BILEY For property located at: 30 BURNT HILLS Dr in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: BRIAN BILEY STEPHANIE UNICK Deck $3,000.00 30 BURNT HILLS Dr Total Value $3,000.00 QUEENSBURY, NY 12804-0000 Contractor or Builders Name/Address Electrical Inspection Agency Plans &Specifications 2009-188 615 SQ FT DECK& 210 SQ FT GAZEBO $82.50 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday, May 15,2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before:the expiration te.) rrr Dated at the T wn o ee ,f 0 tay, ay 15, 2009 SIGNED BY f� for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20090188 Date Issued: Tuesday, October 30, 2012 This is to certify that work requested to be done as shown by Permit Number P20090188 has been completed. Location: 30 BURNT HILLS Dr Tax Map Number: 523400-308-008-0001-057-000-0000 Owner: BRIAN BILEY Applicant: BRIAN BILEY This structure may be occupied as a: Deck By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan,Variance, or other issues and conditions as a result of approvals by the Planning Board Director of Building&Co n ement or Zoning Board of Appeals. FICE�USE ONLY TAX MAP-NO. PERMIT MTNO. FEE PAID Sj _ BLDG. &CODES APPROVAL ; ACCESSORY STRUCTURE BUILDING PERMIT Use this application for any structure other than the Principal Structure(house)to include, but no garage,shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Str s- ShedslFences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT.NO INSPECTIONS WILL BBE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. OWNER: 13R/ J I . L�'C>� INSTALLER/BUILDER: (22iC Af ©L2.,A��R� ADDRESS: 30 B o i'� - ,N l tts 01miC ADDRESS: (cis -138 PHONE NOS. PHONE NOS. 57 .3-Z5.3/ 6x ?-5d-1 LOCATION OF PRO RTY: SUBDIVISION NAME: &Lirf'A3i"' /7'/14tS LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: A TTA,ct/E1)%A k.-AR CIF NoL��<� %'/�` � �r ESTIMATED COST OF CONSTRUCTION: $3X 000 ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? 6 IF YES,PLEASE LIST: CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: PHONE: PROPOSED CONSTRUCTION 1�FLOOR R TOTAL PROPOSED HEIGHT SQ.FT. SQ.FT FT.&IN. OPEN PORCH ( v DECK t 3 SEASON,COVERED OR ENCLOSED PORCH- BOATHOUSE BOATHOUSE WITH SUN DECK DOCK SHED POLE BARN DETACHED GARAGE(NO.OF CARS: OTHER ACCESSORY STRUCTURE: *CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO)REQUIREMENT IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge,the statements contained in the application,together with the plans and specifications submitted,are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes,the Zoning Ordinance,and all other laws pertaining to the proposed work shall be complied with,whether specified or noted,and that such work is authorized by the owner. Further, it is understood that Itwe shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued,as requested by the Zoning Administrator or Director of Building and Codes,an As-Built Survey by a licensed surveyor,drawn to scale, =CALL1-6256 OR EMAILshowing actual location of all new construction. burV.netI have read and agree to the above. ORE INFORMATIONury.net Signed Dated: Name/Title(Printed) Town of Queensbury■ Community Development Office • 742 Bay Road, Queens bury, NY 12804 I w---> ca. 4a- / - —15 Queensbury Building & Code Enforcement - Residential Final innspection Office No. (518)761-8256 Arrive: am/pm art am/pm Date Inspection request received: Inspector's Initials: NAME: r l I e PERMIT* 9— LOCATION: o DATE: p - oc;, / TYPE OF STRUCTURE: a � Comments: 4" Building Number Address visible from road Y No NIA Chimney Height/'B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 18 inches Roof Complete/Exterior Finish Complete Platform at ell exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 Inches above grade Guard at stairwell at 34 inches or more Guard at dedc,porches 36 inches or more �\ Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Brad /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen waterfight Safety glazing/Window in stairwells safety lain Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery baccu Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 s .it:150 sq.ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation to floor/Sticker on Panel Duct work sealed propedy4 Blower Door Test Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within One of site Oil Fumaoe sNA-aff at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrodc Underside minimum'r4"G m Basement stairs dosed rise>4 inches ,"5 Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Gas Logs in Sealed or Glass Enclosure Final Electrical;Energy Saving Light Bulbs 50% Final Survey Plot Plan Arc Fault Breaker Habitable Spaces/Tamper Proof Receptacles Flex Gas Pipe Bonding As Built Sepfic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification if required .Okay to issue C/C or C/O 1 Temporary/Permanent L:1Budding&Codes FormslBuilding&Codesllnspection FormsWesidential r w1w Inspection Form_revised_100405.doc;Revised January 7,2008;Revised 6/26/08; Revised 12/22/10,Revised 04/13/11 C l L co") /VI- l z- dot Queensbury Building & Code Enforcement - Residential Fi I Inspection Office No. (518)761-8256 Arrive: am/p rt: am/pm Date Inspection request received: Inspector's Initials: NAME: R PERMIT#: C97 LOCATION: --7,Kl DATE: - TYPE OF STRUCTURE JJr- N f Comments: a NIA 4' Building Number Address visible from road Chimney,Height/'B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs decks patios more than 30 inches above grade I Guard at stairwell at 34 inches or more �- Guard at deck porches 36 inches or more n� Handrail Termination at Newell Post or Wall interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapp2d Ramp Compliant Grade away from foundation 6 inches with 10 feet C� 6 inch dearance to sill plate Gas Valve shut-off e /regulator 18 inches above grade Interior privacy I trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety lain /Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 .ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stoppiEg finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area - Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(sl Installed 1 Heat Trap/Water Temp 110 Enclosed Stairs Sheetrodk underside minimum IN Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garaae fireproofing/%hour fire door/door closer Duct work Sealed Properly Gas Logo in Sealed or Glass Enclosure _ Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bondin As Built Septic System 1 Sewer Dept. ins ction Sticker Site Plan /Variance required Flood Plain Certification,if required Oka to issue C/C or C 10 Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Forrn_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 Framing / Firestopping Inspection Report /-� " ( , � Office No. (518)761-8256 Date Inspection request received: Q .Z Ui Queensbury Building &Code Enforcement Arrive: am/pm part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:,r � NAME: S + �� PERMIT LOCATION: - ; i I5 v-( INSPECT ON: o J TYPE OF STRUCTURE: G- Y N I NIA COMMENTS: naming Attic Access 22'x 30' minimum Jack Studs/HeadersC Bracing/Bridging Joist hangers Jadc Posts/Main Beams Exterior sheeting nailed properly 12'O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Coilinghyall Windows Habitats Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Forms-OLDrB MhV&CodesUnspec ion FOMSTra rr ing FndoppkV Inapection Rspott.doc Revised January 7,2006 Foundation Inspection Report ( 2- Z Office No.(518)761-8256 Date Ins do i : & 1 Queensbury Building&Code Enforcement Arrive: - p art: pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's In als: NAME: RMIT� #: — � � LOCATION: INSPECT ON: 0 TYPE OF STRUCTURE: —c Comments Y NA Piers.. i onolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofing Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Buliding&Codes Forms\Building&Codes\lnspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM PLOT PLAN SIDE PROPERTY LINE /p `,/IrE IJO DISTUR ANCE BUF7 ZI]NE: / . . , , , . / . , . 100 / Sca `50' } rz)C. 9' Do MILt / \ '-r r i PRLu+E]SfD PRC7PDSE:D ` -� COVERED DECK LEVEL NL 1 r H GAZEBO �� IMPOSED �y DECK. LEVEL. N2 % XISTING <SEPTIC TANK Z�4 AMIALTT�DRIVEVAY�\ SWATER QPPLY 505 LAJ e �o c y -OWN OF QUEE BUILDING DEPARTMENT Bas our limited examination, �6ompliance with our comments shall not be construed as indicating the plans and specifications are in full compliance with the Building codes of I SQUARE = 5 F T, �'�� New York State. STRUCTURAL PLAN A FOUNDATION FOR074' SPA 4-5 PERSON, APPROX. 270 GAL 6' DEEP SOLID CONCRETE SLAB 96'x96' SO, REBAR REINFORCED e'-z 36' DP FOOTERS AT 4 CORNERS -15'-10 DECK SUB-STRUCTURE PRESSURE TREATED WOOD THROUGHOUT LEVEL 1 (285 SO FT) AND GAZEBO (210 SO FT) 495 SO FT TOTAL, 2x6 DECKING 2x6 J❑ISTS, 24' D.C. (6' MAX JOIST SPAN) 4x6 BEAMS (6'-2` MAX BEAM SPAN) 4x4 POSTS (37 sq-ft LOAD AREA) LEVEL 21 330 SO FT, 2x6 DECKING 2x6 JOISTS, 24' D.C. (6'-6' MAX JOIST SPAN) 4x6 BEAMS (6'-6' MAX BEAM SPAN) 4x4 POSTS (43 sq-ft LOAD AREA) 34'- 1/2' 17'-6 1/4' 7'-10 1/r EXISTING HOUSE (BACK SIDE) SCALE: 1/8" = 1'-0" STRUCTURAL PLAN (ELEVATION) to fly 2x8 RAFTERS TO SUPPORT SHINGLED ROOF 12 Q 8 2x10 FASCI 4x4 POST ro i 0 rn «. x 30' HIGH RAI ro to --I H Z rn rri 00 a c� I I 2�_8• I r-- v LI -JI LI J IiI III GROUND SLOPE1- IL_JI L-J L_J L-J L-J L_J �-JL I I L_J 08, 36' DEEP CONCRETE FOOTINGS 6' DEEP CONCRETE SLAB W/ 4 36' DEEP FOOTNGS SCALE: 3/16" 1'-0"