Loading...
2009-198 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090198 Application Number. A20090198 Tax Map No: 523400-278-000-0002-003-000-0000 Permission is hereby granted to: MARK SCHACHNER For property located at: 1324 BAY Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: MARK SCHACHNER 1324 BAY Rd Porch $15,000.00 LAKE GEORGE, NY 12845 Total value $15,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2009-198 352 SQ FT PORCH $40.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday,June 04,2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at ther7ee ury� rs y,June 04, 2009 SIGNED BY � �� for the Town of Queensbury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF COMPLIANCE Permit Number: P20090198 Date Issued: Friday, June 17, 2011 This is to certify that work requested to be done as shown by Permit Number P20090198 has been completed. Tax Map Number: 523400-278-000-0002-003-000-0000 Location: 1324 BAY Rd Owner: MARK SCHACHNER Applicant: MARK SCHACHNER This structure may be occupied as a: Porch By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Compliance DOES NOT relieve the Caw f� property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. F_x:72�3.............................. ..... . ....... FFICE USE ONLY — D lS C IS 9 V E *MAP�N . PERMIT NO. ; MAY 18 2009 FEE PAID BLDG.&CODES APPROVA p1�11h1_OF.CUEEN,SBllEZY: BUILDING& CODES ACCESSORY STRUCTURE B ILDING PERMI PPLICATI N Use this application for any structure other than the Principal Structure (house) to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures- Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. /� ,I 1 n p n OWNER: M ARk "�C-KMGp.�t'�1y�1� INSTALLER/BUILDER: MA f� /�� V/y' ADDRESS: L ag Y (51 RC)A-j� ADDRESS: 4fftM'ERW Kyt � jexfj PHONE NOS. '7 q �; /I' q 3 PHONE NOS. rI91 g�2?!7'I LOCATION OF PROPERTY: `' Ati E SUBDIVISION NAME: LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: ©F f STI A-)6 HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPROVAL? ❑YES I'NO IF SO,INDICATE APPLICATION NO.AND DATE OF APPROVAL: ESTIMATED COST OF CONSTRUCTION: �!� ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? E 5 IF YES,PLEASE LIST: 3 CAR c—"P RA6-f— 'jig IQ tj CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: V` PHONE: . d :&?7 sr ND PROPOSED PROPOSED CONSTRUCTION 1 FLOOR 2 FLOOR TOTAL HEIGHT SQ.FT. SQ.FT. SQ.FT. FT.&IN. OPEN PORCH DECK 3 SEASON,COVERED OR ENCLOSED PORCH' 3�a a /l BOATHOUSE BOATHOUSE WITH SUNDECK DOCK SHED POLE BARN DETACHED GARAGE(NO.OF CARS: ) OTHER ACCESSORY STRUCTURE: "CONSIDERED FLOOR AREA & MUST COMPLY WITH FAR [FLOOR AREA RATIO] REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction. QUESTIONS? CALL 761-8256 OR EMAIL I have read and to the above. codes(cDgueensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION Signed _Dated: www.gueensbury.net - r Town of Queensbury- Community Development Office - 742 Bay Road, Queensbury, NY 12804 Queensbury Building & Code Enforcement -Refdential F* I Inspection nn Office No. (518)761-8256 Arrive: a pa a M Date Inspection request received: Inspector's Ink! 'IV NAME: I 1 PE IT LOCATION: I I 777- E: V, TYPE OF STRUCTURE: :n371�30 Comments: I in NO 4' Buildina Number Address visible from mad Chimney Height I*B*Vent/Direct Vent Location Fresh Air Intake 3 Inch Plumbing Vent through roof minimum 6 Inches Roof CoMoete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,pathqmk more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 38 Inches or more Handrail Termination at Nowell Post or Wall Interior/Exterior Railings 34 Inches to 38 Inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 Inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed regulator 18 inches above grade Interior pLhM/trim/doom main entrance 36 Inches Bathroom/Kitchen watertight ghgLng/Window In stairwells safety giazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: — Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces IS Inch x24 inch access, IN.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing Mures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency 2gMg below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fw,nace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed I Heat Tra Water Temp110 Enclosed Stairs Sheetrock Underside minimum W GMMM Basement stairs dosed rise>4 inches Go"Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed propoy Gas Loge in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker In Bedrooms Flex Gas Pi Rq Bonding As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,If required Okay to issue C I C or C 10[Teen ors Permanent I LABuilding&Codes Form"uilding&CodeeMnspectlon FormsWeeklential Final Inspection Forrnjevised_100405.doc;Revised January 7,2006;Revised MAW Queensbury Building & Code Enforcement - Re ' Mimi F' al Inspection O ice No. (518)761-8256 Arrive: a a Date Inspection request received: Inspector's initia : NAME: MIT#: LOCATION: DATE: TYPE OF STRUCTURE: ors Comments: Y N A 4' BuildingNumber Address visible from road ChimneyHeight/"B'Vent/Direct Vent Location Fresh Air intake 3 Inch Plumbina Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete I -15*t LA- Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks Wigs more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall tnterior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off a used/re ulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safe glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Batte badku Attic access 30 inches x 22 inches x 30 inches (height) in accessible area Crawl Spaces 18 inch x 24 inch access 1 sq.ft.-150 s .ft.vents Bathroom Fans if no window Plumbing fixtures, Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrodk Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct worts Sealed properly Gas Logo in Sealed or Glass Enclosure Final Electrical FttJ�iL I � Final Survey Plot Plan Arc Fault Breaker in Bedrooms E Flex Gas Pipe Bonding As Built Septic System/Sewer Dept. ins cation Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to Issue C/C or C 10 Temporary/Permanent L(Building&Codes FormsWuilding&Codes\Inspedion FormsWesidential Final Inspection Form revised 100405.doc;Revised January 7,2006;Revised 6/26/08 /0 - / r�r�` -� . Rough Plumbing / Insulation 1 pection Report Office No. (518) 761-8256 Date Inspection r st a ived: Queensbury Building &Code Enforcement Arrive: ` - am art: T iT-�rn�m 742 Bay Road, Queensbury, NY 12&M Inspector's I NAME: S� A cl Ae r PE IT #: 7 7?. LOCATION: / INSPECT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing/ Nail Plates Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washing Machine Drain 2 inch minimum Cieanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping �815 minutes Insulation/Re idential Check/Commercial Check 30 c )uU T ek or SiMLAr Exterior Sealant P--1 y w;�"\o r ent, Attic Vent Door/Window Sealed No insulation) w Duct/Hot Water Piping insulation ®y L If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm rt: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: >C-el I,I -/.I ,� PERMIT#: LOCATION: __ I Z j,7-)-/-/� INSPECT ON: TYPE OF STRUCTURE: Y N A COMMENTS: raming Attic Access 22" x 30" minimum Jadc Stud/Headers 00, l- Bracing/Bridging Joist hangers Jadc Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D naAs each side Draft stopping 1,000 sq. fG floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation Hasse side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade L:\BWkkg&Cods Forms-OL01Buildi q&CodesUispedion Fo msTrerning Fnedoppinp Inspection Repat.doc Revised January 7,2N6 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection 7 Queensbury Building&Code Enforcement Arrive: rt: I / 742 Bay Road, Queensbury, NY 12804 Inspecto t NAME: C, - — PERMIT* —� LOCATION: J INSPECT ON: — TYPE OF STRUCTURE: Y N WA COMMENTS:, NT Attic Access 22" x 30" minimum Jadc Studs/Headers _ Bracing/Bridging l tJ 5 L%L— Joist hangers Jack Posts/Main Beams 0 p �� Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairweits 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses And or Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Pei eba5on sealed 16 Inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 518 inch Type X Ceilin ll Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LASuilding&Codes Forms-0U)ftikfing&CodesUspedion FornisWr ruing Firsdoppft Inspsctlos Report.doc Revised January 7,2008 Framing / Firestopping Inspection Report Office No. (518)761-8256 Date I i Queensbury Building $Code Enforcement Arrive: a part: 742 Bay Road, Queensbury, NY 12804 Inspector's I NAME: ERMIT#: —19_ 1 ?,7-1-4 A R INSPECT ON: — TYPE OF STRUCTURE: Y Framing A COMMENTS: .� Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jadc Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft floor trusses Anchor Botts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Fortes-OWSuNding&Codes4nspedion FonnsTfur irg Fwsstopping Inspection Raport.doc Revised January 7,2W8 Framing / Firestopping InspecfRMIT Office No. (518)761-8256 Date lnspection : Queensbury Building&Code Enforcement Arrive: 1' i :��j am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's In ' NAME: S b YVe LOCATION: TYPE OF STRUCTURE: Y N NIA COMMENTS Framing Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Y--Lk ` 7 Q Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Fomts-QLD\BuildN&CodesYnspection FwmsTwing Fwastopping Irapection Report doc Revised January 7,2006 Foundation Inspection Report ` Office No.(518)761-8256 Date In tion ?e ,��' Queensbury Building&Code Enforcement Arrive: epart: m 742 Bay Rd.,Queensbury,NY 12804 Inspector's IniriNAME: � h P L / LOCATION: / INSPECT ON: TYPE OF STRUCTURE: Comments Y N N/A Footings p L Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 f. L:\Bullding&Codes Forms\Building&Codes\InspeCtion Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM ocl - 17Y SOWN OF QUEENSBURY BUILDING DEPARTMENT Based on our limited examination, ! compliance with our comments shall 5 .� not be construed as indicating the plans and specifications are in full compliance with the Building Codes of New York State. f � i. 0Py ,. NOTICE N a KRAFT PAPER INSULATION MUST a COHERED BY NON-COMBUSTIBLE O:Aibo r�G-i N©T jG J�CAC� I D i is I ! � I I ! I NOTICE I FOA INSULATION MUST BE C V!-r" r BY 15 MINUTE THERMAL B� i . . � , � A �' �: �'�'x'" n ,1 r., � `� ��� ���' �.� �„