inspectionsINSPECTION WORKSHEET (BINS-001474-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0032-2019 Case Module:Permit
Inspection Date:Fri Mar 15, 2019 Inspection Status:Partial Pass
Inspector:Mark Smith Inspection Type:Building Insulation
Job Address:Parcel Number:43 COUNTRY CLUB RD
Queensbury, NY 12804
296.15-1-15
Contact Type Company Name Name
Applicant Clute Enterprises, Inc.
Granted Permission Clute Enterprises, Inc.
Primary Owner Clute Enterprises, Inc.
Contractor Clute Enterprises, Inc.
Checklist Item Passed Comments
Building Inspector Notes NO 3/6/19 house wrap approved. Missing windows need to be
inspected before siding is installed.
Insulation baffles installed
3/12/19 remaining windows installed and taped
Insulation approved for first floor only, basement not
completed.
3/15/19 insulation in doors and windows approved
Recheck basement this afternoon
R38 in the ceiling R21 in the walls
Ok to Sheetrock.
3/15/19 Basement insulation approved.
U Factors = .3 cfm for windows, .5 cfm for doors YES .30
Blower Door Test NO
Fresh air supply 3' from grade NO
Mar 15, 2019 Page (1)
INSPECTION WORKSHEET (BINS-001474-2019)
Checklist Item Passed Comments
Duct Insulation - if required in unheated spaces NO
Door / Window Sealed (No Insulation)NO
Air Barrier behind Knee Walls NO
Tub Shower R-20 with Vapor Barrier NO
Duct Blaster Test for duct work, R-8 NO
Mar 15, 2019 Page (2)
Smith, Mark (Inspector)
INSPECTION WORKSHEET (BINS-001425-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0032-2019 Case Module:Permit
Inspection Date:Fri Mar 15, 2019 Inspection Status:Partial Pass
Inspector:Mark Smith Inspection Type:Building Insulation
Job Address:Parcel Number:43 COUNTRY CLUB RD
Queensbury, NY 12804
296.15-1-15
Contact Type Company Name Name
Primary Owner Clute Enterprises, Inc.
Contractor Clute Enterprises, Inc.
Granted Permission Clute Enterprises, Inc.
Applicant Clute Enterprises, Inc.
Checklist Item Passed Comments
Building Inspector Notes NO 3/6/19 house wrap approved. Missing windows need to be
inspected before siding is installed.
Insulation baffles installed
3/12/19 remaining windows installed and taped
Insulation approved for first floor only, basement not
completed.
3/15/19 insulation in doors and windows approved
Recheck basement this afternoon
R38 in the ceiling R21 in the walls
Ok to Sheetrock.
Window Sealing NO
U Factors = .3 cfm for windows, .5 cfm for doors YES .30
Blower Door Test NO
Mar 15, 2019 Page (1)
INSPECTION WORKSHEET (BINS-001425-2019)
Checklist Item Passed Comments
Fresh air supply 3' from grade NO
Duct Insulation - if required in unheated spaces NO
Door / Window Sealed (No Insulation)NO
Tub Shower R-20 with Vapor Barrier NO
Air Barrier behind Knee Walls NO
Duct Blaster Test for duct work, R-8 NO
Mar 15, 2019 Page (2)
Smith, Mark (Inspector)
INSPECTION WORKSHEET (FIST-001293-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0032-2019 Case Module:Permit
Inspection Date:Wed Mar 6, 2019 Inspection Status:Partial Pass
Inspector:Mark Smith Inspection Type:Firestopping
Job Address:Parcel Number:43 COUNTRY CLUB RD
Queensbury, NY 12804
296.15-1-15
Contact Type Company Name Name
Granted Permission Clute Enterprises, Inc.
Contractor Clute Enterprises, Inc.
Primary Owner Clute Enterprises, Inc.
Applicant Clute Enterprises, Inc.
Checklist Item Passed Comments
Building Inspector Notes NO 3/6/19 fire stopping for vertical penetrations Approved
Fire separation 1, 2, 3 hour NO
Fire wall 2, 3, 4 hour NO
Fireproofing NO
Firestopping YES
Penetration sealed YES
16 inch insulation in cavity min.NO
Mar 06, 2019 Page (1)
INSPECTION WORKSHEET (FIST-001293-2019)
Checklist Item Passed Comments
Garage Fire Separation NO
House side ½ inch or 58 inch Type X NO
Garage side 5/8 inch Type X NO
Ceilingwall NO
Mar 06, 2019 Page (2)
Smith, Mark (Inspector)
INSPECTION WORKSHEET (BINS-001291-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0032-2019 Case Module:Permit
Inspection Date:Wed Mar 6, 2019 Inspection Status:Partial Pass
Inspector:Mark Smith Inspection Type:Building Insulation
Job Address:Parcel Number:43 COUNTRY CLUB RD
Queensbury, NY 12804
296.15-1-15
Contact Type Company Name Name
Granted Permission Clute Enterprises, Inc.
Contractor Clute Enterprises, Inc.
Primary Owner Clute Enterprises, Inc.
Applicant Clute Enterprises, Inc.
Checklist Item Passed Comments
Building Inspector Notes NO 3/6/19 house wrap approved. Missing windows need to be
inspected before siding is installed.
Insulation baffles installed
Window Sealing NO
U Factors = .3 cfm for windows, .5 cfm for doors NO
Tyvek or Similar Exterior Sealant YES
Proper Vent, Attic Vent YES
Insulation Residential Check Commercial Check NO
Blower Door Test NO
Mar 06, 2019 Page (1)
INSPECTION WORKSHEET (BINS-001291-2019)
Checklist Item Passed Comments
Combustion Air Supply for Furnace NO
Fresh air supply 3' from grade NO
Duct Insulation - if required in unheated spaces NO
Door / Window Sealed (No Insulation)NO
Air Barrier behind Knee Walls NO
Tub Shower R-20 with Vapor Barrier NO
All Ductwork Sealed Return and Supply NO
Duct Blaster Test for duct work, R-8 NO
All Return Air Hard Duct Work NO
House Wrap Taped at all Seams NO
Mar 06, 2019 Page (2)
Smith, Mark (Inspector)
INSPECTION WORKSHEET (BINS-001290-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0032-2019 Case Module:Permit
Inspection Date:Wed Mar 6, 2019 Inspection Status:Partial Pass
Inspector:Mark Smith Inspection Type:Building Framing
Job Address:Parcel Number:43 COUNTRY CLUB RD
Queensbury, NY 12804
296.15-1-15
Contact Type Company Name Name
Granted Permission Clute Enterprises, Inc.
Contractor Clute Enterprises, Inc.
Applicant Clute Enterprises, Inc.
Primary Owner Clute Enterprises, Inc.
Checklist Item Passed Comments
Building Inspector Notes NO
3/6/19 install bolts at foundation sill plates
Install missing bridging blocks at exterior walls in basement
Garage not framed at time of inspection
Install lag bolts at columns in the basement
Framing NO
Attic Access 22 x 30 minimum YES
Jack Studs Headers YES
Continuous Header for Garage Doors with
Straping
NO Garage not framed at this time
Truss Specification Provided YES
Mar 06, 2019 Page (1)
INSPECTION WORKSHEET (BINS-001290-2019)
Checklist Item Passed Comments
Bracing Bridging NO Install missing bridging at exterior walls, will recheck at
insulation inspection
Hurricane Clips/Uplift Screws/Nail Holes Filled YES
Air Seal all Plates and Sills NO
Air Seal All Registers at Floor NO
Air Sealing all Joints Before Insulation NO
Joist hangers YES
Jack Posts Main Beams YES
Exterior sheeting nailed properly YES
12 O.C.YES
Headroom 6 ft. 8 in.YES
Notches Holes Bearing Walls YES
Metal Strapping for Notches Top Plate NO
Draft stopping 1,000 sq. ft. floor trusses NO
Anchor Bolts 6 ft. or less on center NO Install missing bolts at foundation sill plates
Ice and water shield 24 inches from wall YES 2/26/19 ice and water approved
Mar 06, 2019 Page (2)
INSPECTION WORKSHEET (BINS-001290-2019)
Checklist Item Passed Comments
Soffits-Insulation Baffel YES
Windows Habitable Space Bedrooms NO
24 in. (H)NO
20 in. (W)NO
5.7 sf above below grade NO
5.0 sf grade NO
Design Professional Sign-off, if required NO
Mar 06, 2019 Page (3)
Smith, Mark (Inspector)
INSPECTION WORKSHEET (BINS-001393-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0032-2019 Case Module:Permit
Inspection Date:Tue Mar 12, 2019 Inspection Status:Partial Pass
Inspector:Mark Smith Inspection Type:Building Insulation
Job Address:Parcel Number:43 COUNTRY CLUB RD
Queensbury, NY 12804
296.15-1-15
Contact Type Company Name Name
Applicant Clute Enterprises, Inc.
Granted Permission Clute Enterprises, Inc.
Primary Owner Clute Enterprises, Inc.
Contractor Clute Enterprises, Inc.
Checklist Item Passed Comments
Building Inspector Notes NO 3/6/19 house wrap approved. Missing windows need to be
inspected before siding is installed.
Insulation baffles installed
3/12/19 remaining windows installed and taped
Insulation approved for first floor only, basement not
completed.
R38 in the ceiling R21 in the walls
Window Sealing NO
U Factors = .3 cfm for windows, .5 cfm for doors NO
Blower Door Test NO
Combustion Air Supply for Furnace NO
Mar 12, 2019 Page (1)
INSPECTION WORKSHEET (BINS-001393-2019)
Checklist Item Passed Comments
Fresh air supply 3' from grade NO
Duct Insulation - if required in unheated spaces NO
Door / Window Sealed (No Insulation)NO
Air Barrier behind Knee Walls NO
Tub Shower R-20 with Vapor Barrier NO
All Ductwork Sealed Return and Supply NO
Duct Blaster Test for duct work, R-8 NO
All Return Air Hard Duct Work NO
House Wrap Taped at all Seams NO
Mar 12, 2019 Page (2)
Smith, Mark (Inspector)
INSPECTION WORKSHEET (RPLUM-001166-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0032-2019 Case Module:Permit
Inspection Date:Wed Feb 27, 2019 Inspection Status:Failed
Inspector:Mark Smith Inspection Type:Rough Plumbing
Job Address:Parcel Number:43 COUNTRY CLUB RD
Queensbury, NY 12804
296.15-1-15
Contact Type Company Name Name
Granted Permission Clute Enterprises, Inc.
Applicant Clute Enterprises, Inc.
Primary Owner Clute Enterprises, Inc.
Contractor Clute Enterprises, Inc.
Checklist Item Passed Comments
Building Inspector Notes NO 2/13/19 plumbing under slab approved
2/27/19 vent pipe must be capped on the exterior of the
building for air test.
Sanitary line must be capped on the exterior side of the
foundation for air test.
Plumbing Under Slab YES 2/13/19 Plumbing under slab approved. Holding 10 PSI for
15 minutes
Rough Plumbing / Nail Plates NO
Plumbing Vent Vents in Place NO
3" Vent Through Roof NO
1 ½ inch minimum Drain Size NO
Feb 27, 2019 Page (1)
INSPECTION WORKSHEET (RPLUM-001166-2019)
Checklist Item Passed Comments
Shower liner test (2" of water)NO
Washing Machine Drain 2 inch minimum NO
Washing Machine Trap: 18"-24" discharge NO
Cleanout every 100 feet change of direction NO
Pressure Test NO
Drain Vent NO
Air Head NO
5 psi or 10 ft. above highest conn. for 15 minutes NO
Pressure Test NO
Water Supply Piping NO
Air Head NO
50 P.S.I for 15 minutes NO
Air Test Gas Piping 10 psi for 10 Minutes NO
All Return Air Hard Duct Work NO
Duct Insulation - if required in unheated spaces NO
Duct Testing Outside Conditioned Space NO
Feb 27, 2019 Page (2)
INSPECTION WORKSHEET (RPLUM-001166-2019)
Checklist Item Passed Comments
Duct work sealed properly NO
Feb 27, 2019 Page (3)
Smith, Mark (Inspector)
INSPECTION WORKSHEET (RPLUM-001166-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0032-2019 Case Module:Permit
Inspection Date:Wed Feb 27, 2019 Inspection Status:Failed
Inspector:Mark Smith Inspection Type:Rough Plumbing
Job Address:Parcel Number:43 COUNTRY CLUB RD
Queensbury, NY 12804
296.15-1-15
Contact Type Company Name Name
Granted Permission Clute Enterprises, Inc.
Applicant Clute Enterprises, Inc.
Primary Owner Clute Enterprises, Inc.
Contractor Clute Enterprises, Inc.
Checklist Item Passed Comments
Building Inspector Notes NO 2/13/19 plumbing under slab approved
2/27/19 vent pipe must be capped on the exterior of the
building for air test.
Sanitary line must be capped on the exterior side of the
foundation for air test.
Plumbing Under Slab YES 2/13/19 Plumbing under slab approved. Holding 10 PSI for
15 minutes
Rough Plumbing / Nail Plates NO
Plumbing Vent Vents in Place NO
3" Vent Through Roof NO
1 ½ inch minimum Drain Size NO
Feb 27, 2019 Page (1)
INSPECTION WORKSHEET (RPLUM-001166-2019)
Checklist Item Passed Comments
Shower liner test (2" of water)NO
Washing Machine Drain 2 inch minimum NO
Washing Machine Trap: 18"-24" discharge NO
Cleanout every 100 feet change of direction NO
Pressure Test NO
Drain Vent NO
Air Head NO
5 psi or 10 ft. above highest conn. for 15 minutes NO
Pressure Test NO
Water Supply Piping NO
Air Head NO
50 P.S.I for 15 minutes NO
Air Test Gas Piping 10 psi for 10 Minutes NO
All Return Air Hard Duct Work NO
Duct Insulation - if required in unheated spaces NO
Duct Testing Outside Conditioned Space NO
Feb 27, 2019 Page (2)
INSPECTION WORKSHEET (RPLUM-001166-2019)
Checklist Item Passed Comments
Duct work sealed properly NO
Feb 27, 2019 Page (3)
Smith, Mark (Inspector)
INSPECTION WORKSHEET (BINS-000842-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0032-2019 Case Module:Permit
Inspection Date:Fri Feb 8, 2019 Inspection Status:Partial Pass
Inspector:Charles Dyer Inspection Type:Building Foundation
Job Address:Parcel Number:43 COUNTRY CLUB RD
Queensbury, NY 12804
296.15-1-15
Contact Type Company Name Name
Granted Permission Clute Enterprises, Inc.
Primary Owner Clute Enterprises, Inc.
Contractor Clute Enterprises, Inc.
Applicant Clute Enterprises, Inc.
Checklist Item Passed Comments
Building Inspector Notes NO Not ready 2/7/18, will reschedule for 0830 2/8/19
2/8/19 footings Approved
Footings YES
Piers NO
Monolithic Slab NO
Reinforcement in Place YES 2 rows of #4 continuous.
Foundation / Wallpour NO
Reinforcement in Place NO
Feb 08, 2019 Page (1)
INSPECTION WORKSHEET (BINS-000842-2019)
Checklist Item Passed Comments
Footing Dowels or Keyway in place NO
Foundation Dampproofing NO
Foundation Waterproofing NO
Footing Drain Daylight or Sump NO
Footing Drain Stone - 12 inch width NO
Footing Drain Stone - 6 inches above footing NO
Footing Drain stone - 6 mil poly NO
Backfill Approval NO
Plumbing Under Slab NO
PVC / Cast / Copper NO
Foundation Insulation Interior / Exterior NO
Rough Grade 6 inch drop within 10 ft.NO
Poly Under Slab NO
Feb 08, 2019 Page (2)
Dyer, Charles (Inspector)
INSPECTION WORKSHEET (RPLUM-000925-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0032-2019 Case Module:Permit
Inspection Date:Wed Feb 13, 2019 Inspection Status:Partial Pass
Inspector:Charles Dyer Inspection Type:Rough Plumbing
Job Address:Parcel Number:43 COUNTRY CLUB RD
Queensbury, NY 12804
296.15-1-15
Contact Type Company Name Name
Contractor Clute Enterprises, Inc.
Applicant Clute Enterprises, Inc.
Granted Permission Clute Enterprises, Inc.
Primary Owner Clute Enterprises, Inc.
Checklist Item Passed Comments
Building Inspector Notes NO 2/13/19 plumbing under slab approved
Plumbing Under Slab YES 2/13/19 Plumbing under slab approved. Holding 10 PSI for
15 minutes
Rough Plumbing / Nail Plates NO
Plumbing Vent Vents in Place NO
3" Vent Through Roof NO
1 ½ inch minimum Drain Size NO
Shower liner test (2" of water)NO
Feb 13, 2019 Page (1)
INSPECTION WORKSHEET (RPLUM-000925-2019)
Checklist Item Passed Comments
Washing Machine Drain 2 inch minimum NO
Washing Machine Trap: 18"-24" discharge NO
Cleanout every 100 feet change of direction NO
Pressure Test NO
Drain Vent NO
Air Head NO
5 psi or 10 ft. above highest conn. for 15 minutes NO
Pressure Test NO
Water Supply Piping NO
Air Head NO
50 P.S.I for 15 minutes NO
Air Test Gas Piping 10 psi for 10 Minutes NO
All Return Air Hard Duct Work NO
Duct Insulation - if required in unheated spaces NO
Duct Testing Outside Conditioned Space NO
Duct work sealed properly NO
Feb 13, 2019 Page (2)
Dyer, Charles (Inspector)
INSPECTION WORKSHEET (BINS-000929-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0032-2019 Case Module:Permit
Inspection Date:Wed Feb 13, 2019 Inspection Status:Partial Pass
Inspector:Charles Dyer Inspection Type:Building Foundation
Job Address:Parcel Number:43 COUNTRY CLUB RD
Queensbury, NY 12804
296.15-1-15
Contact Type Company Name Name
Primary Owner Clute Enterprises, Inc.
Applicant Clute Enterprises, Inc.
Contractor Clute Enterprises, Inc.
Granted Permission Clute Enterprises, Inc.
Checklist Item Passed Comments
Building Inspector Notes NO Not ready 2/7/18, will reschedule for 0830 2/8/19
2/8/19 footings Approved
2/13/19 foundation damp proofing approved
Poly under slab approved.
Footings YES
Piers NO
Monolithic Slab NO
Reinforcement in Place YES 2 rows of #4 continuous.
Foundation / Wallpour NO
Feb 13, 2019 Page (1)
INSPECTION WORKSHEET (BINS-000929-2019)
Checklist Item Passed Comments
Reinforcement in Place NO
Footing Dowels or Keyway in place NO
Foundation Dampproofing YES 2/13/19 damp proofing approved
Foundation Waterproofing NO
Footing Drain Daylight or Sump NO
Footing Drain Stone - 12 inch width NO
Footing Drain Stone - 6 inches above footing NO
Footing Drain stone - 6 mil poly NO
Backfill Approval NO
Plumbing Under Slab NO
PVC / Cast / Copper NO
Foundation Insulation Interior / Exterior NO
Rough Grade 6 inch drop within 10 ft.NO
Poly Under Slab YES Poly under slab approved
Feb 13, 2019 Page (2)
Dyer, Charles (Inspector)
7-i-—"1 Ell T191 ,1. E i-In
TOWN OF QUEENSBUR L—
till MAY 01 2019 pliii
BUILDING& CODE(' Y
____—_1
w,<:::,; • . ,
COMMONWEALIII ELECTRICAL INSPECTION SERVICE.,INC. ' •:.
Main Office 176 Doe Run Road-Msnheim,PA 17545 • .
MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL
V. . Permit No Cert.Nt2 424 1 8 Cut-in Card No .
;;;,. • : ..
. . 1 Owner Cw i-, ic- k+',
. ,Location 13.....c.c::-.,.n.r.y.....cY i2....1 .0 Q,LaZi;e1.0.k ii"'14.- :•
41:.. • . .
Installation C2onsisting of•,,.. Arr2.c?(2(4 X,c-faiii(-Cef 39 Acc-i "-o,5-.
, ...;:. . 02_,F,.4„2:sh...4.,,...?,4?.0:-,,_. ,,,?,. j..,p,i4a,m_x.../---4,;.54.,/kAeA.1.7../ 3,—...•41-C4 . ...,.,,.: .
/??..4/7Ffi•aRee9 /9/2/C17m/2 'Ve e Ala iz.cd.O.r A r Ai., (I .4,cmu'ic.0.Eir 2 c-Q
Installed/3y.......,....4.A.m4...d- Lic No :
••,.
il:::!.: •• The conditions following governed the issuance of this certificate,arid any certificate previously issued is : •'
.•15:':','. cancelled:-
;t This certificate only covers the electrical equipment and installation conditions as of date, Upon the
:J3.. . I introduction of additional equipment or alterations,application shall be promptly made for inspection. .
.•
Inspectors of this Company shall have the privilege of making inspections at any time, and if its
rules arc violated,the Company shall have the right.to revoke this certificate. .
),::, , •
:•
:',.1:: • : Date 1.--4 G-1 7
Member N.F.RA,I.A.E.I. . . ..
ZEi 39Vd oiawnw NOd P8S186L E :II HOZ/TO/SO
INSPECTION WORKSHEET (002418-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0032-2019 Case Module:Permit
Inspection Date:Thu May 2, 2019 Inspection Status:Passed
Inspector:Mark Smith Inspection Type:Residential Final Inspection
Job Address:Parcel Number:43 COUNTRY CLUB RD
Queensbury, NY 12804
296.15-1-15
Contact Type Company Name Name
Granted Permission Clute Enterprises, Inc.
Applicant Clute Enterprises, Inc.
Primary Owner Clute Enterprises, Inc.
Contractor Clute Enterprises, Inc.
Checklist Item Passed Comments
General Comments YES 5/2/19 the following items must be addressed before a C/O
can be issued Provide window control device at living room
windows
Install gasket at attic access
Install bonding for black iron gas piping in basement
Plumbing was observed in basement for possible future
bathroom, any work of this nature will require a building
permit.
5/2/19 above items have been completed, ok to issue C/O
Window guards req:<2' above floor/6' above
grade - quick release installed
YES Provide guards at living room windows
Safety guards installed
Attic Access Gasketed YES Provide gasket at attic access
Gasket installed
May 02, 2019 Page (1)
INSPECTION WORKSHEET (002418-2019)
Checklist Item Passed Comments
Final Survey Plot Plan NO
OK to Issue C/O YES 5/2/19 ok to issue C/O
May 02, 2019 Page (2)
Smith, Mark (Inspector)