inspectionsINSPECTION WORKSHEET (BINS-001583-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0124-2019 Case Module:Permit
Inspection Date:Mon Mar 25, 2019 Inspection Status:Passed
Inspector:Mark Smith Inspection Type:Building Framing
Job Address:Parcel Number:15 ELK RIDGE DR
Queensbury, NY 12804
301.15-1-64
Contact Type Company Name Name
Granted Permission Northern Enterprises General
Contracting LLC
Primary Owner Bierly, Jason
Applicant Northern Enterprises General
Contracting LLC
Contractor Ludwig, George
Checklist Item Passed Comments
Building Inspector Notes NO Framing for basement alterations approved.
Notches Holes Bearing Walls NO
Metal Strapping for Notches Top Plate NO
Anchor Bolts 6 ft. or less on center NO
5.7 sf above below grade NO
Design Professional Sign-off, if required NO
Mar 25, 2019 Page (1)
Smith, Mark (Inspector)
INSPECTION WORKSHEET (BINS-001584-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0124-2019 Case Module:Permit
Inspection Date:Mon Mar 25, 2019 Inspection Status:Passed
Inspector:Mark Smith Inspection Type:Building Insulation
Job Address:Parcel Number:15 ELK RIDGE DR
Queensbury, NY 12804
301.15-1-64
Contact Type Company Name Name
Granted Permission Northern Enterprises General
Contracting LLC
Primary Owner Bierly, Jason
Applicant Northern Enterprises General
Contracting LLC
Contractor Ludwig, George
Checklist Item Passed Comments
Building Inspector Notes NO Insulation approved for basement alterations
U Factors = .3 cfm for windows, .5 cfm for doors NO
Insulation Residential Check Commercial Check YES Existing insulation in basement frame up
Mar 25, 2019 Page (1)
Smith, Mark (Inspector)
INSPECTION WORKSHEET (001585-2019)
Town of Queensbury - Building and Codes - Fire Marshal
742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal
Case Number:RC-0124-2019 Case Module:Permit
Inspection Date:Mon Mar 25, 2019 Inspection Status:Failed
Inspector:Mark Smith Inspection Type:Residential Final Inspection
Job Address:Parcel Number:15 ELK RIDGE DR
Queensbury, NY 12804
301.15-1-64
Contact Type Company Name Name
Contractor Ludwig, George
Granted Permission Northern Enterprises General
Contracting LLC
Primary Owner Bierly, Jason
Applicant Northern Enterprises General
Contracting LLC
Checklist Item Passed Comments
General Comments NO 3/25/19 All work not completed at this time. Call for recheck
when switch plates smoke and c/o detectors light fixtures and
handrail on stairs are completed.
4 inch Building Number Address visible from road NO
Platform at all exterior doors NO
Handrail 4 or more risers NO
Guards at stairs,decks,patios 30" + above grade NO
Guard at stairwell at 34" or more NO
Mar 25, 2019 Page (1)
INSPECTION WORKSHEET (001585-2019)
Checklist Item Passed Comments
Window guards req:<2' above floor/6' above
grade - quick release installed
NO
Handrail Termination at Newell Post or Wall NO
Interior/Exterior Railings 34 to 38 NO
Grade away from foundation: 6" down, 10' out NO
6" clearance to sill plate NO
Gas Shut-off Exposed & Regulator (18) Above
Grade
NO
HVAC Vent Terminal 10' from Lot Line &
Openings
NO
Dryer Duct Max Length 35', Labeled Over 35'NO
Interior privacy/trim/doors/main entrance 36 NO
Bathroom / Kitchen Watertight NO
Low flow toilet 1.3 gal/flushing cycle -
showerhead/faucet
NO
Safety glazing: w/in 5' of tub/shower - stairwell
win/adj to drs
NO
Smoke Detectors: Carbon Monoxide NO
CO in Bedrooms w/Gas NO
Mar 25, 2019 Page (2)
INSPECTION WORKSHEET (001585-2019)
Checklist Item Passed Comments
Smoke Detectors 3' from Kitchens & Baths R314 NO
Every level, Every bedroom NO
Outside every bedroom area NO
Inter Connected NO
Battery backup: _____NO
Crawl Space Access 18 x 24 NO
Bathroom Fans, if no window NO
Plumbing fixtures NO
Foundation insulation to floor NO
Energy Sticker on Elec. Panel:R-Val. & Heating
Sys
NO
Duct work sealed properly NO
Intake Openings NO
HRV or ERV Installed per Bedroom Requirements NO
Emergency egress below grade NO
Furnace shut-off w/in 30 ft. or w/in line of site NO
Mar 25, 2019 Page (3)
INSPECTION WORKSHEET (001585-2019)
Checklist Item Passed Comments
Oil Furnace Shut-Off at Entrance to Furnace Area NO
1/2" Gypsum or House Wall and Gable NO
Basement stairs closed rise greater than 4 inches NO
Basement Egress: 5s.f. window w/sill or Bilco
door
NO
Basement ceiling covered 2x8 fl joist or less NO
Jack posts in basement lagged at top and bottom NO
Fin Elect; Energy Saving Light Bulbs 50 Percent NO
Arc Fault Breaker Habitable Spaces NO
Truss ID Signage Installed at Electrical Meter NO
OK to Issue Temporary C/O NO
OK to Issue C/O NO
Mar 25, 2019 Page (4)
Smith, Mark (Inspector)