Loading...
2009-321 TOWN OF QUEENSBURY 'ow742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20090321 Date Issued: Tuesday, November 24, 2009 This is to certify that work requested to be done as shown by Permit Number P200Q0321 has been completed. Location: 10 BENMOST BUR Ln Tax Map Number. 523400-289-013-0001-054-000-0000 Owner. ROBERT & ANNA CLARK - LE Applicant ROBERT & ANNA CLARK - LE This structure may be occupied as a: Residential Alteration By Order of Town Board TO\ N OF QUEENSBURY 1 Issuance of this Certificate of Occupancy DOES NOT relieve the 4 -"t property owner of the responsibility for compliance with Site Plan, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY f742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090321 Application Number. A20090321 Tax Map No: 523400-289-013-0001-054-000-0000 Permission is hereby granted to: ROBERT & ANNA CLARK- LE For property located at: 10 BENMOST BUR Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queens bury Zoning Ordinance. Type of Construction Value Owner Address: ROBERT &ANNA CLARK- LE Residential Alteration $15,000.00 LINDA CLARK& CAROL SNYDER Total Value 3 BENMOST BUR Ln $15,000.00 QUEENSBURY, NY 12804-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2009-321 400 SQ FT RESIDENTIAL ALTERATION $40.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday,July 16, 2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town of Quee>psbury; , Thursday,July 16, 2009 ' SIGNED BY(' for the Town of Queensbury. Director of Buildinn&Code Enforcement 257. 3 ../_`C OFFICE USE ONLY E CI) ; ; L v TAX MAP NO. ''/ PERMIT NO. 0 ?-32.1 •¢ JUL. u92009 FEES: PERMIT t1 RECREATION ENGINEERING (If applicable) %TOWC.Ol:S UEULSBURY BU• ' SIG & CODES PRINCIPAL ,STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. L / APPLICANT/BUILDER: T(>4_6n Cf 7WNER: WLS6er'T 1Q Mk ADDRESS: ADDRESS: /2 (R:17)70'57' el/7 bile PHONE NOS. Z -L_j 1 kc PHONE NOS. 5/8 93 ?" v� CONTACT PERSON FOR BUILDING &CODES COMPLIANCE: Mita TATIZZ PHONE: 3 LA --L-litct LOCATION OF PROPERTY: / dr'2?Me/574 O&Y". 4nef, ,,P ";fff Ai 1' HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? 0 YES 0 NO Y/9- IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT APPLY TO YOUR O CC O w PROJECT 0 O -.. _, w .Ju- u- u_ w aOv L1Jz < ¢ � o ° d � � of- � wz cn cv cn O u_ H u< a 2 0o SINGLE FAMILY V h 1 LIDO N� TWO-FAMILY MULTI-FAMILY (NO. of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER IF COMMERCIAL OR INDUSTRIAL-NA E OF BUSINESS: ESTIMATED CONSTRUCTION COST: { po FUEL TYPE: G t HEAT TYPE: ph S "HOW MANY FIREPLACE(S): AJi AND/ OR WOODSTOVES(S): A/ / " ZONING CATEGORY: gees ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? (Vc PROPOSED USE OF BUILDING OR ADDITION: tVir *Please complete a separate Application for"Fuel Burning Appliances& Chimneys"available in our office Town of Queensbury • Community Development Office • 742 Baby Road, Queensbury, NY 12804 B 3-LGL 11-05 e • ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? A L ARE THERE EASEMENTS ON PROPERTY? ! \f I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. Signed 7//: Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) r ' Permission is hereby granted to the above This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: • BUIL I , & CODES APP OVAL ZONING APPROVAL DATE DATE QUESTIONS? CALL 761-8256 OR EMAIL codes0aueensbury.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION www.queensbury.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: Special Conditions: Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 err,- �,. 5 -V /0' �_3d `' Queensbury Building & Code Enforcemen - esl en is j - • Inspection Office No. (518) 761-8256 Arrive: - h � 'e• am Date Inspection request received: Inspector's !nit = , NAME: ( Ia r,k-P �----�- PE IT#: LOCATION: /c> /�'v�w.-e: To ^[ .., . D`' E: /f-/`l•-t'? J TYPE OF STRUCTURE: . _ Comments: Ygs No N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake VIE3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete = Platform at all exterior doors NM Handrail 4 or more risers Guards at stairs,decks atio§more than 30 inches above grade mil Guard at stairwell at 34 inches or more .1. Guard at deck,porches 36 inches or more �� Handrail Termination at Newell Post or Wall_ Interior/Exterior Railings 34 inches to 38 inches ��� Deck Bracing/Handicapped Ramp Compliant _11111111.1 Grade awe from foundation 6 inches with 10 feet =1111111 6 inch clearance to sill plate Gas Valve shut-off exposed/reculator 18 inches above •rade IIIIIIIII Interior rivac 1 trim/doors I main entrance 36 inches MINIM Bathroom/Kitchen watertight 11111Z11.11 Safe Iazin /Window in stairwells safe lzin Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom are:: Inter Connected: _ Battery backup: __ Attic access 30 inches x 22 inches x 30 inches(height)in accessible area !PIE= Cr S•aces 18 inch x 24 inch access, 1 sq ft.-150 s..ft.vents — Bathroom Fans,if no window MN Plumbin• fixtures — Foundation insulation/Insulation Certification MI Floor truss,draft stopping finished basement 1,000 sq.ft. Emere en :e ress below •rade IIIII Gas Furnace shut-off within 30 feet or within line of site mil Oil Furnace shut-off at entrance to furnace area — Furnace/Hot Water Heater operatin• Low water shut-off boiler ill Relief Valve s installed/Heat Tra•/Water Tem• 110 Enclosed Stairs Sheetrock Underside minimum'/2"Gypsum Basement stairs closed rise>4 inches II—+T �� Garage Floor Pitched Gara•e fire•roofin• /%hour fire door/door closer I_ � Duct work Sealed properly P' Gas Logs in Sealed or Glass Enclosure ,' 1111111 Final Electrical - MINI Final Surve Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pi•e Bonding As Built Se•tic S stem/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification, if remised r1.2— Oka to issue C/C or C/0 Tern•ore 4 - •:i V IIIIIII orapre-,..0% L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc; Revised January 7,2008; Revised 6/26/08 _ 0 —/1..' • 7t/r � Queensbury Building & Code Enforcement - Resir�nti r ' spection 1- r.-.art: o ='D a ixi' Office Na. (518) 761-8256 Arrive: � ,��' Date Inspection request received: — Inspector's Initi ,�W NAME: ____C ia J MIT#: _ LOCATION: /� `-... (-7 5���� , ATE: f/o TYPE OF STRUCTURE: Comments: as_ Ng. N/A 4° Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location o Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete _ Platform at all exterior doors _ I Handrail 4 or more risers_ -__I Guards at stairs,decks, patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck, porches 36 inches or more _— Handrail Termination at Newell Post or Wall Interior/Exterior Railings:34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant f Grade away from foundation 6 inches with '10 feet ._ a// 6 inch clearance to sill plate f — Gas Valve shut-off exposed/regulator 18 inches above grade / Interior rivacy/trim/dooms/main entrance 36 inches Bathroom/Kitchen watertight ^� Safe lazin /Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 soft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures v/ Foundation insulation/Insulation Certification J _ Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade — RE i-- W, c t4 \f t3 It, Gas Furnace shut-off within 30 feet or within line of site *o C v b tis, b t<= 'S“VIR.S Oil Furnace shut-off at entrance to furnace area — C_- ,.)ER__ tLPr A. t�3��1 L Furnace/Hot Water Heater operating Low water shut-off boiler _._ t t EtrAVA Te � ' t iEti Relief Valve(k)installed I Heat Trap/Water Temp 110 __ �_ -- tdk,,Vic Sit Enclosed Stairs Sheetrock Underside minimum'/"Gypsum / — • % �__ Basement stairs closed rise>4 inches _ ,./ �-c - � v�}� Garage Floor Pitched _ �� 5 1 _S'C f,tom. Garage fireproofing/%hour fire door/door closer E}' ai �H�-�3�- % Duct work Sealed properly _ _Gas Logs in Sealed or Glass Enclosure � ��`� Final Electrical — __ f- SE -9 F t d2"-E'1L_. ELIL�W r Final Survey Plot Plan Arc Fault Breaker in Bedrooms '_ `i`SO��-` .i QS 41 r�Qs Flex Gas Pipe Bonding �� As Built Septic System/Sewer Dept, Inspection Sticker ?;by.- , Site Plan /Variance required Flood Plain Certification, if required Okay to issue C 1 C or C I 0[Temporary/Permanent[ - L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form_revised_100405.doc; Revised January 7, 2008; Revised 6/26/08 Rough Plumbing / Insulation Ins '1: ction Report Office No. (518) 761-8256 Date Inspec do equest received: Queensbury De Building & Code Enforcement Arrive: ! • m/ ) part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials_ NAME: PERMIT #: O3z/ LOCATION: 0li\ f5V /3v r^L., , INSPECT ON: 7 TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Ai d 0 P.S.I 15 minutes Insulation / esidential Check I Commercial Check Tyvek imilar Exterior Sealant r Vent, Attic Vent ��O Pe V � G Door/Window SealedSNo Insulation) Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/ No duct tape "rt irze1/4f COMMENTS: Rough Plumbing Insulation Repoitrevised Nov 17 2003, revised February 15,2005, revised January 7, 2008 Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement am/pr, pepart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: *. PERMIT #: ` 772- LOCATION: 11 0(2, INSPECT ON: 0 TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping (A I /Air / Head 50 P.S.I for 15 minutes Cal I ;aQ vc Insulation / Residential Check / Commercial Check l\ Proper Vent, Attic Vent Duct / Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape I - COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 Framing / Firestopping Inspection Repo Office No. (518)761-8256 Date Inspeotio,request received: Queensbury Building &Code Enforcement Arrive: 1,, ( am/ 1 ' e rt: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT#: LOCATION: / /kaitF' 00err , INSPECT ON: TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing /3'\iC x 30" minimum /Z- Ce4V( Jack Studs/Headers /` Bracing/Bodging `h ci *rc �' 3 2/ -4 00 f Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly PR b\ L�6 U cx 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Jot 7- Exterior Deck Bracing Headroom 6 ft. 8 in. 2- , (l�l „i-c Notches/ Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side p Draft stopping 1,000 sq. ft. floor trusses f 1 o\ R V" A D tj r')l(31-'.4(- Anchor Bolts 6 ft. or less on center 0 P ro A-16 ) F'cg Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour ✓*irestopping �` /p 490' Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Fortes-OLIMuiiding&Codes\Inspection FomnsTrammg Firestopping Inspection Repoitdoc Revised January 7,2008