Loading...
2009-261 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 Community Development-Building& Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090261 Application Number: A20090261 Tax Map No: 523400-296-013-0001-048-000-0000 Permission is hereby granted to: PETE & SUE ROMAN For property located at: 110 MONTRAY Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: ANGEL TORRES C/O SUSAN ROMAN Garage Detached $9,500.00 110 MONTRAY Rd Total value $9,500.00 QUEENSBURY, NY 12804-0000 Contractor or Builder's Name /Address Electrical Inspection Agency WILLIAM MINER 151 BROAD St GLENS FALLS, NY 12801-0000 Plans&Specifications 2009-261 400 SQ FT GARAGE $40.00 PERMIT FEE PAID-THIS PERMIT EXPIRES: Saturday, June 26, 2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Town otQueei' bury;i� rid J e 26, 2009 C �. @ SIGNED BY �'�� '� for the Town of Queensbury. Director of Building& Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 4z Community Development- Building &Codes (518) 761-8256 CERTIFICATE ('1"FE7 OCCUPANCY Permit Number. P20090261 Date Issued: Monday, June 07, 2010 This is to certify that work requested to be done as shown by Permit Number P20090261 has been completed. Location: 110 MONTRAY Rd Tax Map Number. 523400-296-013-0001-048-000-0000 Owner. ANGEL TORRES Applicant: PETE & SUE ROMAN This structure may be occupied as a: Garage Detached By Oder of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, VV Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. %_._� ---lV FFICE USE ONLY ..------ ; p ram Ir�;-- '� _�_ v�n _ d - , Is S TAX MAP NO. PERMIT NO. ; FEE PAID "BLDG.&CODES APPROVAL ; ; JUN z 2 200911 , , I ,........................ ;�. �. i BUILDING & CODES ACCESSORY STRUCTURE BUILDING PERM Use this application for any structure other than the Principal Structure (house) to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures- Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PEWIT. OWNER: tom- ` ,SIv%e iwl INSTALLER/BUILDER: (V I ((t%dW"- ADDRESS: 116 r&• _ ADDRESS: I ''j�1_ 13 fa PHONE NOS. a- 3'{� -3ifQ5- 5 l2 - 10o _IBC PHONE NOS__j � ! YS—66,-/f LOCATION OF PROPERTY:'<4-"'C SUBDIVISION NAME: X&no- _­� LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: IiQ �pri-�"A:tipQ_a nS� Qy HAS THERE BEEN A SITE PLAN REVIEW;VARIANCE OR SUBDIVISION APPR AL? ❑YES ANO IF SO,INDICATE APPLICATION NO.AND DATE OF APPROVAL: M ESTIMATED COST OF CONSTRUCTION: $ o ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? /Vp IF YES,PLEASE LIST: CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: i kl\man ^per PHONE: 1ST ND PROPOSED PROPOSED CONSTRUCTION 1 FLU OR 2 FLOOR TOTAL HEIGHT SQ. %T. SQ.FT. SQ.FT. FT.&IN. OPEN PORCH DECK 3 SEASON,COVERED OR ENCLOSED PORCH' BOATHOUSE BOATHOUSE WITH SUNDECK DOCK SHED POLE BARN DETACHED GARAGE(NO.OF CARS: ) ,OTHER ACCESSORY STRUCTURE: *CONSIDERED FLOOR AREA & MUST COMPLY WITH FAR [FLOOR AREA RATIO] REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge, the statements contained in the application, together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes, the Zoning Ordinance, and all other laws pertaining to the proposed work shall be complied with, whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed surveyor, drawn to scale, showing actual location of all new construction. QUESTIONS? CALL 761-8256 OR EMAIL Queensbury Building & Code Enforcement - sidential Final Inspection Office No. (518)761-8256 Arrive: � am/p part: am/pm Date Inspection request received: Inspect 's itiais: NAME: PERMIT#: �OU KI/ LOCATION: �. DATE: TYPE OF STRUCTURE: Commen,�• N A 4' Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 ches Roof Cghylete/Exterior Finish Com ete Platfbrki at all exterior doors ......._...,,- Guards at stairs deckspatios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Brads /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to silt plate Gas Valve shut-off sed I regulator 18 inches above grade Interior rtv /trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 N.ft.-150 ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,dreftstopping finished basement 1,000 sq.ft. Emergency ress below grade Gas Fumace shut-off within 30 feet or within line of site Oil Fumace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs SheeVock Underside minimum'A"Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed properly Gas Logs in Sealed or Glass E osu Final Electrical 7 � Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bond in As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C I C or C 10 1 Temporary/Permanent L:1Building&Codes FormslBuilding&Codesunspection FormsWesidenbal Final Inspection Fonn_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 Queensbury Building & Code Enforcement _ sidential Final inspection %ce No. (518)761-8256 Arrive: S am/p De am/pm Date Inspection request received: Inspecto's Initials: NAME: PERMIT#: LOCATION: YK v DATE: TYPE OF STRUCTURE: Comments: N/A 4" Building Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risen; Guards at stairs decks atios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Extedor Railings 34 inches to 38 inches Deck Bract /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off a sed i regulator 18 inches above grade Interior privacy I trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells 9fety glazing Interior Smoke Detectors/Carbon Monoxide Detector Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 sq.ft.-150 ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 ft. Emergency ress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off bailer Relief Valves installed/Heat Trap,/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum Basement stairs dosed rise>4 inches l Game Floor Pitched a 0 0 /= S f1 K K Garage fireproofing/%hour fire door/door closer �1 Duct work Seated DroDerly Gas Logs in Sealed or Gloss Ejnc19sure__ Final Eledri Final Survey Plot Plan Are Fault Breaker in Bedrooms rr ICA Flex Gas Pi Bonding .�L t'�/� �CC' As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 1 Temporary/Permanent L:\Building&Codes Forms\Building&Codes\Inspection FonnsWesidential Final Inspection Form_revise0_100405.doc;Revised January 7,2008;Revised 6/26/08 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit No. ....I..........Cert. N D 112 0 9 Cut-in Card No..................................... Owner........,.../ ............................................................................................................. .......... Location..../..lO....../.'�U. ✓L �. 7. Installation Consisting of.�..?l!!�..�..."T:J�..... � /'1, . ��- .................................................................................................................................................................................... .................................................................................................................................................................................... Installed B m�/U4�- y................... ..................................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of ma inspections at any time, and if its rules are violated,the Company shall have the righat k,6 9Date.`..*.�.V.l...................... INSPECTOR.. . ..............................:.......................................... Member N.F.P.A.,I.A.E.1. Framing / Firestopping Inspection Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building &Code Enforcement Arrive: am/pm Depart: pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: - NAME: PERMIT� ,�J PERMIT#: LOCATION: 1a Av en �yq INSPECT ON: -�- TYPE OF STRUCTURE: C7A- L Y N WA COMMENTS• naming Attic Access 27 x 30" minimum Jadc Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed property 12'O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each etas Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling1wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:1f3uild'rng&Codes Forms-01-MuNdft&CodesUrispedion Fort aTra nirp Fkedoppft Inspection Report.doc Revised January 7,2006 Framing / Firestopping Inspectio Report Office No. (518)761-8256 Date Inspection request received: Queensbury Building Code Enforcement Arrive: „�00 am/ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials:�y NAME: PO rKa. PERMIT#: LOCATION: INSPECT ON: Y TYPE OF STRUCTURE: Framing Y N NIA COMMENTS: Attic Access 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nags each side Draft stopping 1,000 sq. ft. floor trusses or less on center Ice and water Id 24 inches from wall Ire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 518 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade LABuiiding&codes Forms-OLDrBuilding&CodesNnspection FomaT aming Fi edoppkV Inspection Repatdoc Revised January 7,2008