2009-273 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090273 Application Number. A20090273 Tax Map No: 523400-289-011-0002-007-000-0000 Permission is hereby granted to: EDWARD & ELIZABETH ALLEN For property located at: 853 BAY Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: EDWARD & ELIZABETH ALLEN BESSIE CONSTANTINE Certificate of Occupancy(RES) $20,000.00 853 BAY Rd Total value $20,000.00 QUEENSBURY,NY 12804 Contractor or Builders Name/Address Electrical Inspection Agency KELLY ELECTRIC 793-3022 11 WILLOW Rd QUEENSBURY,NY 12804-0000 Plans &Specifications 2009-273 RESIDENTIAL REHAB - HUD $25.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday,June 19, 2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the Townji� Que bu / Fri , 9,2009 SIGNED BY for the Town of Queens bury. ury. Director of Building&Code Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 (zt Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUP-A-NCY Permit Number. P20090273 Date Issued: Tuesday, September 01, 2009 This is to certify that work requested to be done as shown by Permit Number P20090273 has been completed. Location: 853 BAY Rd Tax Map Number. 523400-289-011-0002-007-000-0000 Owner. EDWARD & ELIZABETH ALLEN Applicant: EDWARD & ELIZABETH ALLEN This structure may be occupied as a: Certificate of Occupancy(RES) By Order of Town Boatel TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, ` r Variance,or other issues and conditions as a result of approvals by the Director of Building& e E ement Planning Board or Zoning Board of Appeals. � ..... ..................... ............ Z ................ _._W_ �j_ OFFICE USE ONLY TAX MAP NO. PERMIT NO. i v FEES: PERMIT` RECREATION JUN 18 Z1109 —__ENGINEERING -----------------------______ (If applicable) .. ----TQVVU F__QU.FFjNSBURY BUILDING & CC�DE� .. PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID/PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: /GC �lC OWNER: ADDRESS: C' uhJ�.�� ADDRESS: PHONE NOS._ :�d 7� 2 U PHONE NOS. CONTACT PERSON FOR BUILDING & CODES COMPLIANCE: PHONE: 1_7 5 j LOCATION OF PROPERTY: S3 GQ HAS THERE BEEN A SITE PLAN REVIEW; VARIANCE OR SUBDIVISION APPROVAL? ❑ YES ❑ NO IF SO, INDICATE APPLICATION NO. AND DATE OF APPROVAL: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT OZ r APPLY TO YOUR z C1 d o PROJECT 1 0 Q O 0 UJ w o � 0LL w —� 0 = = a Z 0 � CJ z C1 F- � OH � wZ Q Q (n N to 0 u- F- LL 4. 2 o2S SINGLE FAMILY ___ q ' / C>'�7' FWO-FAMILY MULTI-FAMILY (NO. of UNITS ) TOWNHOUSE ! BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER —� IF COMMERCIAL OR INDUSTRIAL— NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: 46 ) 00,�' FUEL TYPE: HEAT TYPE: *HOW MANY FIREPLACE(S): AND/ OR WOODSTOVES(S): B 3-LGL 11-05 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete state me nt/d escri ptio n of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read ydagr e to the above. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is herebyranted to the above g ; This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: ; o 0 , o o BUILDING & CODES APPROVAL 0, ZONING APPROVAL o o o DATE o DATEo , (--QUESTIONS? CALL 761-8256 OR EMAIL codes(a)-gueensbury.net Office Use OnIY VISIT OUR WEBSITE FOR MORE INFORMATION /- 3 Mo Queensbury Building & Code Enforcement - Res' ential Final Inspection Office No. (518) 761-8256 Arrive:1,: _,", . -2;, -,I ra ff ep Date Inspection request received: Inspector's Initia : NAME: E IT LOCATION: E TYPE OF STRUCTURE: Comments: Yn N WA ,V Building Number Address visible from road Chimney Height/"B°Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Co lete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/HandicaoDed Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Vann shut-off a sed/re ulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety lzin /Window-in stairwells safety glazing Interior Smoke Det ors 1 Carbon Monoxide,Detectors Every level: 7Battery 'Bedrop m: Outside every bedroo : JJ 1 Inter Connected: badcu : -/ Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, .ft:150 s .ft.vents Bathroom Fans if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valves instal e 1 Heat TraI Water Temp 110 Enclosed Stairs Sheetrock Underside minimum"A*Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Sealed rt Gas Loge in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Are Fault Breaker in Bedrooms Flex Gas Pipe Sondin As Built Septic System 1 Sewer De . Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required Okay to issue C/C or C 10 1 Temporary 1 Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residenbal Final Inspection Forrm_revised_100405.doc;Revised January 7,2008;Revised 6/26/08 / - Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection requ?#: 'V/ / Q Queensbury Building & Code Enforcement Arrive: V-ZD art: a 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: A/_L� PER O LOCATION: INSPECT ON: G TYPE OF STRUCTURE: YZ__ Y IN NIA lit Plates v� PI;uMbing Vent/Vents in Place 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cieanout every 100 feet!change of direction Pressure Test Drain /Vent Air/Head 5 ft. above highest connection for 15 minutes X.,/ IV Pi in Head for 15 minutes ' ential Check!Commercial Check T e tN imilar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace t—+czc,,-v-- Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspe ion epo C 2 Office No. (518)761-8256 Date Inspection IERMIT / G Queensbury Building &Code Enforcement Arrive: 2 - 2t7 part: ar t6 742 Bay Road, Queensbury, NY 12804 Inspector's Initia NAME: L L-ey' f #: —.2 7 LOCATION: V3 tq INSPECT ON: TYPE OF STRUCTURE: Y N NIA COMMENTS: ming � �R— 4e " Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed property 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Dedc Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wail Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in qp min. Garage Fire Separation House side%inch or SM inch Type X Garage side 5/8 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuildit&Codes Forms-OLMSuilft&CodesUnspection FoffmTrery ft FiresbppkV Inspacdoa ROPOrtd0c Revised January 7,2000