Loading...
2009-279 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090279 Application Number. A20090279 Tax Map No: 523400-309-005-0001-003-011-0000 Permission is hereby granted to: M & C VENTURES, LLC For property located at: 326 SHERMAN Ave in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the QueensburyZoning Ordinance. Tyne of Construction Value Owner Address: M &C VENTURES, LLC ATTN: DOUGLAS MILLER Garage Detached $15,000. 0 4 STONE PINE Ln Total value $15,00000 QUEENSBURY,NY 12804-0000 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2009-279 841 sq ft 1 st floor& 348 sq ft 2nd floor(1189 sq ft total) garage $118.90 PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday,July 24, 2010 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the f Quee ury; Friday,July 24,2009 SIGNED BY ✓' I/�. for the Town of Queensbury. Director of Buildin&Co Enforcement TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201 4E Community Development - Building & Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20090279 Date Issued: Friday, May 30, 2014 This is to certify that work requested to be done as shown by Permit Number P20090279 has been completed. Location: 326 SHERMAN Ave Tax Map Number: 523400-309-005-0001-003-011-0000 Owner: M & C VENTURES, LLC Applicant: M & C VENTURES, LLC This structure may be occupied as a: Garage Detached By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan,Variance, or 'Dj W other issues and conditions as a result of approvals by the Planning Board Director of Building&Code Enforcement or Zoning Board of Appeals. --------------------�---- - _--_----- - ,� - ---- 0OFFICEUSEONLY�� �T P PERMIT NO. ; ; JUN 19 2009 ; FEE PAID� BLDG. &CODES APPROVA SOWN OF QUEENSBURY __: �_8t11%Qlia;6-cGCaDE&---- ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION Use this application for any structure other than the Principal Structure (house)to include, but not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3 entitled Accessory Structures- Sheds/Fences. A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT.NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS RECEIVED A VALID BUILDING PERMIT. OWNER: M&C Ventures, LLC INSTALLER/BUILDER: M &C Ventures, LLC ADDRESS: 4 Stone Pine Lane ADDRESS: 4 Stone Pine Lane PHONE NOS. (518)793-1493/ 232-4199 PHONE NOS. (518)793-1493/ 232-4199 LOCATION OF PROPERTY: ADKSC 326 Sherman Ave. SUBDIVISION NAME: N/A LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: ADKSC, 326 Sherman Ave, Queensbury, NY ESTIMATED COST OF CONSTRUCTION: $ 15,000 ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? NO IF YES,PLEASE LIST: CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: Douq Miller PHONE: 743-1086/232-4199 1ST FLOOR 2ND FLOOR TOTAL PROPOSED PROPOSED CONSTRUCTION SQ.FT. SQ.FT. SQ.FT. HEIGHT FT.&IN. OPEN PORCH DECK 3 SEASON,COVERED OR ENCLOSED PORCH' BOATHOUSE BOATHOUSE WITH SUNDECK DOCK SHED POLE BARN DETACHED GARAGE(NO.OF CARS: ) 841 348 22' 1 OTHER ACCESSORY STRUCTURE: `CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO]REQUIREMENTS IF THE STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE. To the best of my knowledge,the statements contained in the application,together with the plans and specifications submitted, are a true and complete statement of all proposed work to be done on the described premises and that all provisions of the Building Codes,the Zoning Ordinance,and all other laws pertaining to the proposed work shall be complied with,whether specified or noted, and that such work is authorized by the owner. Further, it is understood that I/we shall submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested by the Zoning Administrator or Director of Building and Codes,an As-Built Survey by a licensed surveyor,drawn to scale, QUESTIONS? CALL 761-8256 OR EMAIL showing actual location of all new construction. codes(a�queensburV.net I have read an ree to the at�ov. VISIT OUR WEBSITE FOR MORE INFORMATION Signed �, Dated: 7�r7 e www.gueensbury.net Name/Title(Printed) / v Town of Queensbury • Communihj Development Office • 742 Bay Road, Queensbury, NY 12804 Town of Queensbury Building&Code Enforcement Office No. (518)761-8256 Commercial Final Inspection Report Inspection request receiv Name: e_ Inspected on: -3 3 /y' Location: er A-C e,ti Arrive: 3 j a.m./p.m. Permit No.: O5— Z Inspector's Initials: W� COMMENTS Y N NA Chimney/"B"Vent I Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10'or Equivalent Interior/Exterior Guardrails 42 inch Platform/Decks Interior/Exterior Balusters 4 inch Spacing Platform/Decks Stair Handrail 34 inch—38 inch/Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft. All Doors 36 inch w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36"(w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator(18")Above Grade Floor Bathroom Watertight/Other Floors Okay Relief Valve,Heat Trap/Water Temperature 110 Degrees Maximum Boiler/Furnace Enclosure 1 hour or Fire Extinguishing System Fresh Air Supply for Occupancy I Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft.or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors > 10%>1000 sq.ft. '/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour,3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping,3,000 sq.ft.Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Signage/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets/Mirrors Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 inch,Checkout 36 inch Handicapped Ramp/Handrails Continuous/12 inch Beyond[Both sides] Active Listening System and Signage Assembly Space Final Electrical/Flex Gas Piping Bonded Site Plan I Variance required Final Survey,New Structure/Flood Plain certification, if req. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4" Water Fountain or Cooler Building Access All Sides by 20'/Drivable Surface 20'wide Special Inspections/Engineer or roval Okay To Issue Temporary o ermanent C/0 Okay To Issue C/C Commercial Final Inspection-1 127 12 . Commercial Final Inspection Report Office No.: (518) 761-8256 Date Ins pe ctron request received: Queensbury Building &Code Enforcement Arrive: a ' pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: I1 ,� Dr, ; t- PERMIT#: , LOCATION: .. = 1.�- '\C jC_ DATE: .5-f 5 /V COMMENTS: Y N NA Chimney/'B'Vent/Direct Vent Location Plumbing Vent Through Roof 6'/Roof Com lets Exterior Finish/Grade Complete 6'in IV or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks h J Interior/Exterior Ballisters 4 in. Spacing Platform 1 Decks Stair Handrail 34 in.—38 in./Stop Risers 7"/Treads 11" Vestibules For Exit doors>3000 sq.ft All Doors 36 in.w/Lever Handy/Panic Hardware, if required Exits At Grade Or Platform 36 w x 44'(lyCanopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18' Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp.110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupy /Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Lime Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockmom/Storage/ReceMng/Shipping Room(2 hr.), 1 %doors > 10%> 1000 sq.ft. %Hour Corridor Doom&Closers Firewalls/fine Separation,2 Hour, 3 Hour Complete/Fire Dam /Fire Doors Ceiling Fire Stopping, 3,000 sq.ft.Wood Frame Attic Access 30'x 20"x 30" h ,Crawl Spam Access 18'x 24' Smoke Vents Or Fan, if required Elevator Operation and Si /Shaft Sealed Hand' Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Signage Public Toilet Room Handicapped Accessible Handicapped Service Counters,34 in.,Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both sides Active Listening System and Signage Assembly Space Final EkK*ical/Flex Gas Piping Bonded Site Plan/Variance required Final Survey, New Structure/Flood Plain certification,if As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway 4' Water Fountain or Cooler Building Access AN Sides by 20'/Driveable Surface 2W wide Okay To Issue Temp. or Pennanent C/O Okay To Issue C/C LABuilding&Codes FormslBuilding&CodesUnspection Fomis%Commercial Final Inspection Report.doc Revised January 7,2008 Queensbury Building.& Code Enforcement - 4iffiftia ntial Fin spection No. (518)761-8256 Arrive: De rt: am Date Inspection request received: Inspecto 0NAME: F [� P R T#: LOCATION: D U—faD— 12� TYPE OF STRUCTURE. ' Comments: 4' Buildby Number Address visible from d 6,�o! Chimney Height/'B'Vent/Direct Vent Location Fresh Air Intake 3 Inch Plumbina Vent through roof minimum 6 inches Roof Co /Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers y Guards at stairs decks os more than 30 inches above tads Guard -`— at stairwell at 34 inches or more Guard at dock,porches 36 inches or more Handrail Termoation at Newell Post or Wall 1 ;� } {�-�► t 1 tnterkx/Exteror Railings 34 inches to 38 inches R�ia� Deck Bra /Handica Ram Compliant b 9J Grade away from foundation 6 Inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off ggosed/regulator 18 inches above grade _ interior pdvaq I trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Sa /Window in stairwells safety glazbv Interior Smoke Detectors/Carbon Monoxide Detectors s Every level: Every Bedroom: Outside every bedroom area: inter Connected: Battery backup: Attic access 30 inures x 22 inches x 30 Inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 N.ft:150 89.ft.vents Bathroom Fans if no window Plumbina fixtures Foundation insulation/Insulation Certification Floor truss draft finished basement 1,000 ft. Emergeng 2UEm below grade Gas Furnace shut-off within 30 feet or within line of site _ ON Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves Installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrack Underside minimum'IN Gypsum Basement stairs dosed rise>4 inches Ga Floor Pitched Garage fireproofing/%hour fire door I door.closer Duct walk Sealed pMpft Gas Loos in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc fault Broker in Bedrooms Flex Gas Pipe Bonding As Built Septic System I Sewer Dept. In Sticker Site Plan I Variance required Flood Plain Certification,if re uired Okay to issue C/C or C 10 1 Temporary/Permanent L:1Building&Codes FormslBuilding&CodeeMnspeclion FormslResidential Final Inspection Form_revised_100405.doc;Revised January 7,2008;Revised MOM Framing / Firestopping Inspection Rt`f fI Office No. (518)761-8256 Date Inspection Queensbury Building &Code Enforcemerrt Arrive: = rt: am 742 Bay Road, Queensbury, NY 12804 Inspector's In NAME: i�-"��' r�,�_-p_ tj �— s19 „r �V�"ERMIT#: Oq-2,7? LOCATION: A�f,%VC INSPECT ON: i?� TYPE OF STRUCTURE: Y WA COMMENTS: fEraming Attic Access 22"x 30' minimum Jack Studs/Headers L � Bracing!Bridging c �� yU�,;,L,�, ,�? i�r__ Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. is 'u"r,`7 CEO- a;,'��j 'V Zr Headroom 6 ft. 8 in. �v ,�F A Stairwells 36 in. or more `7 Exterior Deck Bracing Headroom 6 ft. 8 in. �L Notches!Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge U8 16D naffs each side - Draft stopping 1,000 sq.ft,floor trusses Anchor Botts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour , Fire wall 2, 3, 4 hour Firestopping '� ,� Penetration sealed 16 inch insulation in cavity min. 'N j�: C�v Garage Fire Separation Howse side's inch or 518 inch Type X Garage side 5/8 inch Type X Ceilingtwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade L:\Buil N&Codes F0rms-0LD ding&C0d08*Apedion FwmWrwnkV FnstappkV irspec Wn PAWt.dx Revaed January 7,20M