2006-705 (2)EXISTING FENCE TO BE TEMPORARILY REMOVED AND REPLACED AS REQUIRED 6 N 8" CMU FDN WALL 40'-0"f EXISTING SANITARY OUTLET PIPE ------------------�---- 16'-0 "f +I EXISTING COVERED DECK 0 I EXISTING SUMP PIT TO REMAIN.--\ r -- --- -- -- --- -- __ - _-- - -- ---- '� -----------------_-__-_-------------- rr r--� EXISTING GAS I`� I 1 11 I I HOT-AIR I� _ JI I EXISTING HOT l FURNACE `------J v o \WATER TANK I'I ISI EXISTING BEAM COLUMNS AND POSTS TO REMAIN UP III � III I BEAM POCKET IN I EXISTING DROPPED III CMU FOUNDATION FLOOR BEAM ABOVE i WALL. SEE TYPICAL I i DETAIL FOR MORE INFORMATION EXISTING BASEMENT (2 LOCATIONS) lid i�1 PERFORATED PIPE HIGH SLOPE DRAIN ATNSUMP PITT O -------------------- _ _- - - - - II ---- �------------- — _ — -------------� IS INSTALL NEW 4"0 PERFORATED SLAB WATER METER AND EXISTING MUNICIPAL DRAIN. SAW -CUT EXISTING SLAB Fi-WAAS SHOWN AND SLOPE TO SUMP SUPPLY LINE �n� ------------------------------------------a------I -4 i \-------- L----------- i CONTRACTOR SHALL REMOVE AND PROPERLY DISPOSE OF ALL EXISTING VEGETATION AND LANDSCAPINGFOUNDATION PIAN ADJACENT TO BUILDING WHICH IS REQUIRED TO BE REMOVED FOR WORK TO BE COMPLETED. NOTES: 1. CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY ENGINEER/OWNER OF DISCREPANCIES. 2. CONTRACTOR IS RESPONSIBLE FOR DESIGNING AND IMPLEMENTING A TEMPORARY SHORING SCHEME FOR THE BUILDING. A SHORING DESIGN AND PLAN SHALL BE SUBMITTED TO ENGINEER FOR REVIEW PRIOR TO START OF CONSTRUCTION. PLAN SHALL ALLOW HOMEOWNER TO CONTINUOUSLY OCCUPY RESIDENCE FOR DURATION OF PROJECT. SHORING DESIGN SHALL TAKE INTO CONSIDERATION ALL DEAD AND LIVE LOADS FOR THE BUILDING. J. CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES AND KEEP IN WORKING CONDITION FOR DURATION OF PROJECT, INCLUDING BUT NOT LIMITED TO: NATURAL GAS SERVICE, ELECTRICAL SERVICE, MUNICIPAL WATER SUPPLY, SEWAGE DISPOSAL, AND ETC. ALL PANEL BOXES, PIPES, MECHANICAL EQUIPMENT, AND ETC. SHALL BE TEMORARILY SUPPORTED WHERE ATTACHED TO THE EXISTING FOUNDATION WALL UNTIL PERMANENT RE -ATTACHMENT TO THE NEW FOUNDATION CAN BE COMPLETED. STING FLOOR JOISTS 4" SOLID CMU ON EXTERIOR I II II La I EXISTING DROPPED BEAM 2X4 PRESSURE TREATED BEARING PLATE SOLID CMU AS REQ'D #4 VERT. IN SOLiD GROUTED CORE BELOW BEAM SEARING CMU FOUNDATION WALL TYPICAL WOOD BEAM POCKET DETAIL NOT TO SCALE -- - - -J EXISTING DECK AND ROOF TO BE TEMPORARILY REMOVED AND RELOCATED TO ACCOMMODATE WORK TO BE COMPLETED. RE- INSTALL DECK AND PORCH IN KIND. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MATERIALS AND LABOR RELATED TO THIS NECESSITY. NEW VINYL BASEMENT SASH WITH OPERABLE SASHES. INSTALL TWO LOCATIONS EACH END OF BUILDING AS SHOWN (LOCATE AT EXISTING WINDOWS) LIAND EXISTING CONCRETE STAIR LANDING TO BE REMOVED AND REPLACED WITH TREATED LANDING AND STAIR PER NOTES (2 LOCATIONS) I I I I RE -SUPPORT DROPPED FLOOR BEAM EACH END EXISTING ELECTRIC SERVICE ENTRANCE AND PANEL BOX #4 VERTICAL REINF. AT EACH CORNER AND AT EDGES OF OPENINGS. SEE SECTION FOR MAX. SPACING IN BETWEEN EXISTING NATURAL GAS SERVICE LiNE AND METER SIMPSON A35 CLIP ANGLE AT EACH JOIST TO SILL PLATE (WHEN JOISTS PARALLEL INSTALL 2X BLKG AT 24" O.C. FOR A35) 1/2" CLEARANCE FOR GROUT— TO UNDERSIDE OF SILL PLATE FOR FULL BEARING CONTRACTOR TO REMOVE AND REPLACE EXISTING SIDING AND OTHER BUILDING COMPONENTS AS REQUIRED FOR SHORING AND WORK SHOWN #4X2'-0" LG DOWELS TO MATCH VERTICAL WALL REINFORCING LOCATIONS DRiLL AND EPDXY INTO EXISTING FOOTING MIN. 6 INCHES EXTERIOR WATERPROOFING IN ACCORDANCE WITH CODE FROM T/FOOTING TO FINISHED GRADE ELEVATION EXTERIOR PERIMETER DRAIN - TO BE INSTALLED AND PIPED TO EXISTING SUMP PIT AT INTERIOR OF BASEMENT 5" MATERIAL PROPERTIES Reinforcing: Deformed bars; ASTM A 615, Grade 60. Misc. Wood Framing: No. 2 or better, Spruce -Pine -Fir (SPF). Concrete Block: ASTM C 90 with average net compressive strength of 1900 psi, normal weight. Mortar: ASTM C 270 or ASTM C 1142, Type Grout: ASTM C 476, minimum compressive str-ngth of 2500 psi, 8-10 inch slump. Anchor Bolts: ASTM A 307, Grade A. Foundation Drainage Pipe: Drainage pipe complete with bends, reducers, adapters, couplings and joint materials as follows: Perforated Polyvinyl Chloride (PVC) Pipe: ASTM D 3034, SDR 35. GENERAL NOTES Designed in accordance with 2002 Residentia, Building Code of New York State. Do not scale Drawings. Contractor shall notifi Engineer of any discrepancies in dimensions or elevations. Do not change size or spacing of structural' members. Contractor shall notify Engineer of proposed deviations or substitutions from dimensions or materials shown on the Drawings and make only those deviations or substitutions accepted by Engineer. These Drawings do not include necessary components for construction safety. Contractor shall be solely responsible for construction safety. Use pressure -treated wood for all timber elements exposed to weather or in contact with soil, water, or concrete. FOUNDATION NOTES Excavations shall be laid back to prevent soughing in of sides. Maintain sides and slopes of excavations in stable condition until completion of backfilling. Foundation excavations shall be hand trimmed to remove loose material or ridges left by equipment. Where high groundwater exists contractor shall be responsible for maintaining dry working conditions for placement of foundation components. Install temporary sumps and pump water away from work area as necessary. Backfill foundation walls with sand and gravel which are sound, durable, and free of organic or other deleterious materiais. instr,;; backfili evenly on bath sides of walis where necessary to prevent displacement of construction. Backfill shall not be placed against basement walls until the walls have sufficient strength and have been anchored to the floor above. Finished grade at perimeter of foundation shall be sloped to drain surface water away from building. The grade away from foundation walls shall fall a minimum of 6 inches within first 10 feet. Perimeter foundation drains shall be installed around the entire perimeter of basement as shown on the foundation details. install perforated HDPE pipe with crushed rock wrapped in filter fabric at or below the area to be protected and discharge by gravity or mechanical means into on approved drainage system. Foundation walls that are located in high water table areas or other sever soil -conditions shall be waterproofed with a waterproof membrane `roam the top of footing to finished grade. Anchor sill plate of exterior walls to foundation walls with 1/2 -inch anchor bolts 12 inches maximum from each end and 6 feet maxirnum on center in between. (Minimum of two anchor bolts in each sill piece.) Embed anchor bolts a minimum of 12 inches in concrete block foundation walls. Install horizontal joint reinforcing at 16" on center (every other course) and top two courses. Joint reinforcing shall be galvanized 9 ga. truss type with diagonals not exceeding 16" on center. Install prefabricated T's and corner sections and lap 2 feet with main reinforcing. Reinforced masonry cores shall be grouted solid with grout. Filling masonry cores with mortar is not acceptable. Refer to the Material Notes for grout requirements. Install vertical wall reinforcing where spec;fiyd. Grout CMU cores solid at reinforcing locations. If vertical reinforcing is spliced iop minirn;;r ; 18 inches al' all splices. Take care to properly place bars in cores as dimensioned on details and sections. Ties bars in place to prevent displacement during grouting. EXISTING CONCRETE SLAB AND FOOTING - 6A PY TYPICAL FOUNDATION WALL SECTION NOT TO SCALE TOWN OF QUEENSEURV EI?'I.OINO DEPARTMENT Based on our limiter? examination, compliance with our comments shall not be construed as indicating the plans and specifications are in full compliance with the Building Codes of l New York State. TOWN OF QUEENSb urey BUILDING & CODE EPT. REVIEWED BY DATE /v ty Cts bX 0 w UD I 0 co C\2 y+ Z oli CQ m m w C`J I C\2 COCM GQ y"� �w a 40 O CQ C\2 E- � cc ,-y -J b c�2 m cit I C\2 GD .-� co w w CM I v C\2 d o m CO OD � O a: a F-1 0 W Z W 01 A., ALL FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS SHALL BE CONSIDERED TO BE PART OF THE BUILDING DETAILS AND SPECIFICATIONS HEREIN. IF DISCREPANCIES BETWEEN THE CODES AND REGULATIONS AND THE INFORMATION CONTAINED ON THESE PLANS EXIST THE MORE STRINGENT SHALL APPLY UNLESS THE INFORMATION SHOWN, DESCRIBED, OR IMPLIED IS A VIOLATION OF THE CODE, IN WHICH CASE THE CODE OR REGULATION SHALL TAKE PREFERENCE OVER PLANS. DIG SAFELY NEW YORK - CALL BEFORE YOU DIG - WAIT THE REQUIRED TIME - CONFIRM UTILITY RESPONSE - RESPECT THE MARKERS - DIG WITH CARE SAFE DIGGING IS EVERYONES RESPONSIBILITY! PLEASE CALL 1-800-962-7962 BEFORE YOU DIG., VISIT www.digsafelynewyork.com FOR ADDITIONAL INFORMATION. IT IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DiREOTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. ENGINEERED PLANS CONTAIN ENOUGH DETAILED INFORMATION TO CONSTRUCT A RESIDENTIAL LIGHT FRAMED SINGLE FAMILY DWELLING IN GENERAL CONFORMANCE WITH STATE AND LOCAL BUILDING CODES. PLANS TYPICALLY INCLUDE BUILDING ELEVATIONS, FLOOR PLANS WITH STRUCTURAL COMPONENTS, FOUNDATION PLAN AND DETAILS, AND BUILDING SECTIONS. ELECTRICAL, PLUMBING, AND MECHANICAL SYSTEMS ARE NOT PART OF THESE PLANS AND SPECIFICATIONS AND IT'S RECOMMENDED THAT THESE ITEMS BE INLCUDED IN YOUR BUILDING CONTRACT. YOU SHOULD CONSULT A LOCAL DESIGN PROFESSIONAL FOR EACH ITEM TO VERIFY THESE COMPONENTS ARE DESIGNED AND INSTALLED ACCORDING TO THE APPLICABLE CODES AND REGULATIONS. ENGINEERS STAMP: 0 rn .' w ��OA �0 07 90 S! ab THESE PLANS REQUIRE FIELD VERIFICATION BY THE RESPONSIBLE REGISTERED DESIGN PROFESSIONAL WHO'S SEAL IS PLACED UPON THEM. AT LEAST ONE INSPECTION SHOULD BE PERFORMED AFTER COMPLETION OF ROUGH CARPENTRY OR FRAMING. SCALE: AS NOTED DATE: 2006 DRAWN BY: VISION PROJECT: 17 SEWARD STREET DRAWING TITLE FOUNDATION PLAN AND DETAILS DRAWING N0. DWG 1 o f � STAIR AND LANDING NOTES Stairway shall not be less than 36 inches :vide in clear width at all points above the permitted handrail height and below the required hecoroom height. Handrails shall not project more than -1/2"0 X16" ANCHOR BOLTS TO 4 1/2 inches on either side of the stoirwaf and the minimum clear width of the stairway at EXISTING SILL PLATE and below the handrail height, including treads and landings, shall not be less than 31 1/2 inches GROUT CORES SOLID AT A.B. S where the handrail in installed on one side and 27 inches where the handrails are provided on both sides. -SOLID CMU TOP COURSE The maximum riser height shall be 8 1/4 inches and the minimum tread depth shall be 9 inches. Porches, balconies, or raised floor surfaces located more than 30 inches above the floor or grade below shall have guards not less than 36 inches in height. Open sides of stairs with a total rise 44 VERTICAL REINFORCING of more than 30 inches above the floor or grade below shall have guards not less than 34 inches in height measured vertically from the nosing of the treads. AT CORNERS, OPENING EDGES AND MAX. 32" O.C. IN BETWEEN Required guards on open sides of stairways, raised floor surfaces, balconies, and proches shall have intermediate rails or ornamental closures that do not allow the passage of a sphere 4 inches or more 8" CONCRETE BLOCK FOUNDATION WALL Handrails shall be provided on at least one side of each stairway with two or more risers. Handrail height, measured above the tread nosings, shall be not less than 34 inches and not more than 38 inches. All required handrails shall be continuous the full length of the stairs from a point directly above the top riser of a flight to a point directly above the lowest riser of the flight. HORIZONTAL JOINT REINF. Exterior exit landings, stairs, decks, and similar exit facilities shall be positively anchored to the phimary building structure using handers, lag bolts, screws, or other fastening systems not subject to withdrawal. Use pressure -treated wood for all timber elements exposed to weather or in contact with soil, water, or concrete. Extefior landings shall to constructed from 2x8 at 16" on center joists with SAW -CUT EXISTING CONCRETE joist hangers to a 2x10 ledger bolted to ti -e house with 2-5/16"0 goly. lag bolts at 24" on FLOOR SLAB AND INSTALL center. Cover joists with 5/4x6 treated deo'dng parallel with house wall. Use minimum 4x4 posts PERFORATED PIPE DRAIN IN #2 CRUSHED STONE BED. on outside corners with double 2x8 rim joist at perimeter supported by deck blocks. SLOPE TO EXISTING SUMP PIT AND REPLACE CONCRETE SLAB TO MATCH EXISTING. EXISTING CONCRETE SLAB AND FOOTING - 6A PY TYPICAL FOUNDATION WALL SECTION NOT TO SCALE TOWN OF QUEENSEURV EI?'I.OINO DEPARTMENT Based on our limiter? examination, compliance with our comments shall not be construed as indicating the plans and specifications are in full compliance with the Building Codes of l New York State. TOWN OF QUEENSb urey BUILDING & CODE EPT. REVIEWED BY DATE /v ty Cts bX 0 w UD I 0 co C\2 y+ Z oli CQ m m w C`J I C\2 COCM GQ y"� �w a 40 O CQ C\2 E- � cc ,-y -J b c�2 m cit I C\2 GD .-� co w w CM I v C\2 d o m CO OD � O a: a F-1 0 W Z W 01 A., ALL FEDERAL, STATE, AND LOCAL CODES AND REGULATIONS SHALL BE CONSIDERED TO BE PART OF THE BUILDING DETAILS AND SPECIFICATIONS HEREIN. IF DISCREPANCIES BETWEEN THE CODES AND REGULATIONS AND THE INFORMATION CONTAINED ON THESE PLANS EXIST THE MORE STRINGENT SHALL APPLY UNLESS THE INFORMATION SHOWN, DESCRIBED, OR IMPLIED IS A VIOLATION OF THE CODE, IN WHICH CASE THE CODE OR REGULATION SHALL TAKE PREFERENCE OVER PLANS. DIG SAFELY NEW YORK - CALL BEFORE YOU DIG - WAIT THE REQUIRED TIME - CONFIRM UTILITY RESPONSE - RESPECT THE MARKERS - DIG WITH CARE SAFE DIGGING IS EVERYONES RESPONSIBILITY! PLEASE CALL 1-800-962-7962 BEFORE YOU DIG., VISIT www.digsafelynewyork.com FOR ADDITIONAL INFORMATION. IT IS A VIOLATION OF SECTION 7209 SUBDIVISION 2 OF THE NEW YORK STATE EDUCATION LAW FOR ANY PERSON, UNLESS ACTING UNDER THE DiREOTION OF A LICENSED PROFESSIONAL ENGINEER, TO ALTER THIS DOCUMENT IN ANY WAY. IF AN ITEM BEARING THE SEAL OF AN ENGINEER IS ALTERED, THE ALTERING ENGINEER SHALL AFFIX TO THE ITEM HIS SEAL AND THE NOTATION "ALTERED BY" FOLLOWED BY HIS SIGNATURE, THE DATE OF SUCH ALTERATION, AND A SPECIFIC DESCRIPTION OF THE ALTERATION. ENGINEERED PLANS CONTAIN ENOUGH DETAILED INFORMATION TO CONSTRUCT A RESIDENTIAL LIGHT FRAMED SINGLE FAMILY DWELLING IN GENERAL CONFORMANCE WITH STATE AND LOCAL BUILDING CODES. PLANS TYPICALLY INCLUDE BUILDING ELEVATIONS, FLOOR PLANS WITH STRUCTURAL COMPONENTS, FOUNDATION PLAN AND DETAILS, AND BUILDING SECTIONS. ELECTRICAL, PLUMBING, AND MECHANICAL SYSTEMS ARE NOT PART OF THESE PLANS AND SPECIFICATIONS AND IT'S RECOMMENDED THAT THESE ITEMS BE INLCUDED IN YOUR BUILDING CONTRACT. YOU SHOULD CONSULT A LOCAL DESIGN PROFESSIONAL FOR EACH ITEM TO VERIFY THESE COMPONENTS ARE DESIGNED AND INSTALLED ACCORDING TO THE APPLICABLE CODES AND REGULATIONS. ENGINEERS STAMP: 0 rn .' w ��OA �0 07 90 S! ab THESE PLANS REQUIRE FIELD VERIFICATION BY THE RESPONSIBLE REGISTERED DESIGN PROFESSIONAL WHO'S SEAL IS PLACED UPON THEM. AT LEAST ONE INSPECTION SHOULD BE PERFORMED AFTER COMPLETION OF ROUGH CARPENTRY OR FRAMING. SCALE: AS NOTED DATE: 2006 DRAWN BY: VISION PROJECT: 17 SEWARD STREET DRAWING TITLE FOUNDATION PLAN AND DETAILS DRAWING N0. DWG 1 o f �