SEP-002568-2019 05092019INSPECTION WORKSHEET (SEP-002568-2019) Town of Queensbury - Building and Codes - Fire Marshal 742 Bay Road - (518) 761-8256 Building (518) 761-8206 Fire Marshal Case Number:SEP-0269-2019 Case Module:Permit Inspection Date:Thu May 9, 2019 Inspection Status:Passed Inspector:Mark Smith Inspection Type:Septic Job Address:Parcel Number:1232 WEST MOUNTAIN RD Queensbury, NY 12804 288.-1-65 Contact Type Company Name Name Applicant Sanitary Sewer Service Contractor Sanitary Sewer Service Granted Permission Williams, Tom Primary Owner Williams, Tom Checklist Item Passed Comments Building Inspector Notes YES 1000 gallon poly tank with 96' of absorption field. 3 laterals @ 33 feet each System is for apartment only Type of Water: Municipal / Well Water YES Municipal Waterline separation distance YES 50'+ Absorbtion Fields: Total Length YES 3 laterals @ 33' each Length of Each Trench YES 3 @ 33' each Depth of Trenches YES 18 to 24" May 09, 2019 Page (1) INSPECTION WORKSHEET (SEP-002568-2019) Checklist Item Passed Comments Size of Stone YES #2 Building to Tank YES Sch 40 Tank to Distribution Box YES SDR 35 Distribution box to Field / Pit YES SDR 35 Foundation to Tank YES 15' Foundation to Absorption YES 20' Location of system on property YES Rear of apartment System Use Status YES System approved May 09, 2019 Page (2) Smith, Mark (Inspector)