Loading...
fireplace detail Direct Vent I DirectVent Pro Pipe Length Designed for appliances tested and listed for direct vent.Features a fully unitized twist-lock construction in both 4"x 6 5/a"and 5"x 8"vent sizes. Use of sealant is optional,unless specified by the appliance manufacturer.To calculate install length,subtract 1 1/2" for each joint. No beads or hems.Black pipe lengths feature ii it exterior laser-welded seams. It of 48. � SIZE GALVANIZED BLACK A 4"x 6 5/a 46DVA 06 46DVA 066 6" 4"x 6 5/8" 46DVA-09 46DVA-09B 9" A 4"x 6 5/8" 46DVA-12 46DVA-12B 12" 4"x 6 5/8" 46DVA-18 46DVA-18B 18" 4"x 6 5/8' 46DVA-24 46DVA-24B 24" 4"x 6 5/8" 46DVA-36 46DVA-368 36" 4"x 6 5/e" 46DVA-48 46DVA-488 48" 4"x 6 5/e" 46DVA-60 46DVA-60B 60" 5"x 8" 58DVA-06 58DVA-06B 6" 5"x 8" 58DVA-09 58DVA-09B 9" 5"x 8" 58DVA-12 58DVA-12B 12" 5"x 8" 58DVA 18 58DVA-18B 18" 5"x 8" 58DVA-24 58DVA-24B 24" 5"x 8" 58DVA-36 58DVA-36B 36" 5"x 8" 58DVA-48 58DVA-48B 48" 5"x 8" 58DVA 60 58DVA-608 60" Pipe Extension Use to add length to a straight length of DirectVent Pro.8 W pipe adds 3"-7"of length,16"pipe adds 3"-14 1/2"of length,when used with rigid sections of pipe. Direct vent lengths feature a fully unitized,twist-lock construction.Use of sealant is optional,unless ' specified by the appliance manufacturer. Available in black or 1 3 'j galvalume exterior(both feature laser-welded outer wall seams). �! Does not fit DirectVent GS pipe. SIZE I GALVANIZED I BLACK I A ; EXTENSION i,r`, A 4"x 6 lu" 46DVA-08A 46DVA-08AB 81" 3"-7" 4,, "x 6 5/8 46DVA16A 46DVA-16AB 16" 3"-14'' 5"x 8" 58DVA-08A 58DVA-08AB 81" 3"-7" 5"x 8" 58DVA-16A 58DVA-16AB 16" 3"-141/2" 800-835-4429 I DuraVent 174 Multisided Series Tahoe Direct-Vent Multisided Fireplace Systems Heater Rated at 35,000 Btu input, the Tahoe direct-vent system draws in outdoor air to support combustion and sends its exhaust directly outdoors, and must be located in a position that allows venting through an exterior wall or through the roof. Multisided Tahoe fireplaces install using readily available 4 x 6 5/8 direct-vent pipe. Tahoe systems include a built-in 24-inch Slope Glaze Vista Burner, large tempered-glass viewing windows, Banded Brick Liner, ceramic fiber floor liner, dimmer controlled lighting, and glowing embers.The 24-inch Rock Creek Log Set and barrier screens must be ordered to complete the fireplace. (Doors are not available for multisided fireplaces.) xla 5 ` _r _ r 'x' t f "' af< g,� ti The Tahoe Premium 36 Peninsula Direct-Vent Fireplace(DVP36PP)includes the 35,000 Btu Slope Glaze Vista Burner (for use with Rock Creek refractory log set only),large tempered glass view windows,and Banded Brick Liner shown in Custom Mantel. Fireplace also available in See-Through models with two open sides. Rugged looking refractory logs give the Rock Creek Log Seta rustic look on a grand scale. a 1 Let Opposite side view. - T Right.End view. White Mountain Hearth • Tahoe Direct-Vent Fireplaces 5 DVP36PP32EN-3 DVP36PP32EP-3 o r ' ' 04" a 13/" ii 26156" 065 233 ��ee�� / � f ff — 0 1 L , 401" ► - 421" 2315 6 Li d a a a H A A A H a a o o H 1 0 F—_171', 0 3458 321,E 25„ 40156' 33%' 0 0 — F I . / I + 576 I i 0 0 t L 13 36 J + 2%„J 57/�, -0- -0- 5/8" .- t2/8" . 39" ► Minimum Framing Dimensions for Minimum Framing Dimensions for Deluxe, Premium, & Luxury Models (in inches) Multisided Models (in inches) Model A B C Model A B C DVD32FP 35-3/4 34-3/8 16-3/8 DVP36PP 41-1/2 39 23 DVD36FP 35-3/4 37-3/8 16-3/8 DVP36SP 41-1/2 40 23 DVD42FP 37-3/4 43-3/8 16-3/8 See owners manual for complete dimensions. DVD48FP 37-3/4 49-3/8 16-3/8 0 0 0 DVP36FP 37-3/4 39-3/8 19-7/8 DVCD32FP 39 35-1/4 18 DVCD36FP 39 38-1/4 18 -----A-____ DVCD42FP 41 44-1/4 18 DVP42FP 37-3/4 43-3/8MEM A • DVP48FP 37-3/4 49-3/8 19-7/8 DVX36FP' 40-7/8 39-3/8 19-7/8 DVX42FP 40-7/8 43-3/8 19-7/8 �---__B See owners manual for complete dimensions. Peninsula o00 o �Io oo -- -- — Urn" o ----- . .. ... .. ..., Aft r .....„Jr, 11,rftliill —�g-__�__ B--_____I. Deluxe,Clean-Face Deluxe, See-Through Premium,and Luxury 10-year limited warranty on combustion chamber;limited lifetime on glass. All other parts carry a 3-year limited warranty. All Remote Controls carry a 1-year limited warranty. All direct-vent fireplaces manufactured after January 1,2015,must be installed with a barrier screen to prevent accidental contact with hot glass. Depending on the fireplace model,the barrier screens are available separately or incorporated into decorative fronts. (i _ ),7 r„, js See owner's manual for details. Type of Gas Natural or LP Refer to your Owner's Manual for complete installation and safety information. Iron Pipe Size(N.P.T.) 1/2 inch IMP .IMIIMMIIIINW. Empire is committed to continuous product improvement;specifications are subject to change without notice.Dimensions in this brochure are EMPIRE approximate;read and follow the framing dimensions in the owners manual supplied with your Empire product.Flame size,shape,and color will vary from photos. SINCE 1932 This appliance is design-certified Member of the following industry associations: to the ANSI standard by: Empire Comfort Systems Inc. 918 Freeburg Ave. Belleville,IL 62220-2623 Nf�l M DE info@empirecomfort.com Ham. tHPBArui_'PGA ` � C US I WMH-00641 2/12/19 ..a+.....e. ..�mm ree i IN ADMATE LISTED Z1I Gas rroduccs ..mwwwe.wsr� The Ems Comfort Systems and Mate Mounttin Hearth names and logos am registered U.S.trademarks www.empirecomfort.com Specifications UL 103 HT and ULC S604 System Applications DuraTech 5"-8" 5"-8"DuraTech is a double-wall, With a Thermal Tech blanket insulation encased between dual all-fuel chimney system for use with walls,DuraTech offers the optimum in safety and performance. It wood stoves,fireplaces,furnaces, keeps the outer wall of the chimney cool,while ensuring high flue boilers,ranges,water heaters,or other appliances fueled by wood,oil,coal,or gas temperatures for optimum gas,and zero-clearance fireplaces that draft performance. are factory-built. The inner wall is 25%thicker than competitive chimneys for an Materials and Construction extra margin of safety.No locking bands or mechanical fasteners 5"-8"diameter pipe features inner wall required. of.020"430 stainless steel.Outer wall options of.016"430 stainless steel or .021"galvalume steel. A Thermal Tech DuraTech's sleek 1°"wall design provides for easy installations (ceramic refractory)blanket insulation is through 16"on-center framing.For tight installations,a Reduced encased between walls.Stainless steel Clearance Square Ceiling Support Box is available(6°°diameter end rings seal the pipe. DuraTech only). Dura Tech features light weight insulation,twist-lock fittings,support Designed for normal,continuous operation at 1000°F flue gas boxes with factory installed starter temperatures,DuraTech is subjected to rigorous and stringent HT sections,elbows with 360°swivel base, requirements of the UL standard,including one hour at 1400°F, select black finish pipe lengths,and five plus three ten minute chimney fire tests at 2100°F. foot length pipe sections. Clearances '. :s 2"clearance to combustibles. Shrouds _ UL Listed with DuraVent shroud specifications.Information available online at www.duravent.com or call and request L157. s 5 . Diameters f.`` Listings "'- c-UL-us Listed to UL 103 HT and ULC S604(MH7399) (Stainless steel outer wall required for installation in Canada). - a n Y 21 DuraVent www.duravent.com WCT6820WS EPA Wood Burning Fireplaces Specifications Back Wall of Chase/Enclosure OUTSIDE CHASE Including Flnising Materials If any Corner Installation //� Cat.# Model Description c 19-5/8" F1792 WCT6820WS EPA Wood-Burning D ›/ fireplace *Zero Clearance t From Back `J G F Product Reference Information Spacer to Wall wJ 0 Weight 300 lbs II ,' d, 1 m Height 36" i. 1 " r Width 36" \ I".u A--1.- 1 Depth 24-1/2" .Co Rough Framing Face(Unfinished Shown) '201/2 Firebox W x H x D 22"x 11-3/4" E measured in front x12" �` Chimney weight ASHT (6"dia) 6.25!b/tt. ',. 741 Chimney weight ACa(6"dia.) 3.25lb/it. �gy Chimney Weight S 2100+ (6"dia.) 10.8 Ib/ft. *- �I Available from Security Chimneys h E 10;1 101, 2"X 3"FRAMING DIMENSIONS �., I Min. Fireplace Opening Width A 36-1/4" 921 mm II piywood 1/2" 8 42" 1067 mm Header C 30-1/8" 764 nun ��� 0 13-1/2" 343 mm 7' '� %` E 77" 1956 mm Min. B 1111010fr F 37-1/2" 953 mm B G *24-1/2" 603 mm J 53-3/4" 1365 mm Rough Framing Face * Total depth is 25 inches including the (dimension includes finish kl A •-1 backspacer minus 1/2 inch for drywall material inside framing,if any) to be flush with the facing. Notes Diagrams,illustrations and photographs are not to scale -consultinstallationinstructions.Productdesigns,materials, �F§ dimensions,specifications,colors and prices are subject to - ® 28-1/8" change or discontinuance without notice. 9 3/4" All framing dimensions calculated for 1/2"dry wall at the CV. US �_ 1 fireplace lace.ll sheathing the chase or finishing with other } thickness materials,calculations will need to be made. Report No. 14-199 10-3/8"j *The fireplace must not be in contact with any insulation or 14" loose filling material.Cavertheinsulation withdrywall panels Listed to ULC-S610&UL-127 22-5/8 0: = + +0 24„ around the fireplace. EPA certification test emis- PARTS REQUIRED sion value 3.7 g/hr per 2015 `� standard 1 I1111 I1111 • 6"diameter chimney.-Model ASHT+, S-2100+,HT6000+,HT6103+or AC mane- i{ factured by Security Chimneys International only,including: - Chimney lengths — ' ' ' ' - Elbows oe necessary) - Associated components per installation and operation manual. eo • Decorative Door-Required (OrderSeparately) � 9i +` ,�_i;�:�y2,,i y�+,,, I �i—` - Available in hlack,gold or brushed nickel . 42I" ��. ' _ '-leJ • Front Facade kit-Required •\ , (Order Separatery) - Available in ak r h 'k black,,bus brushed nickel tad ' "" or hammered steel 12-1/4" Ih11 I hill361/8" es. • UZYS blower(included) i_tIII�I�IA ll • VRUW Blower Speed Control(included) IIl11r�!l;711111 17 3/4" • Outside air kit(Included) 4a 17-3/4" _.,_ _:. OPTIONAL EQUIPMENT 13.1/4" • L ��� 3-3/44 • Additional Equipment i L 4 6-3/4-e— 1P-3/4 f - AC Chimney Adaptor s 22-1/2" (required if using AC Chimney) a 8-1/4"---- 15-1/2 AC chimney outside air kit LL 24" 36 Gravity venting system 4 {Available from Security Chimneys.' PM 900161-00,REV.B,04/2015 Page 1 of 2 WI 6820WS EPA Wood Burning Fireplaces Specifications Rain Cap Roof Support Storm Collar — Attic Radiation IIIFlashing Flashing Collar / Shield A'i, Flashing / Floor, � ►i -11. �; NOTE:It is recommended Ill Ceiling& ��� Ji Root Support thatthe chase wallsand floor Wan ��� �� beinsulatedinthesamemanner, Attic Radiation t✓ Shield usingthesame insulation,asthe rest �, of the building,below the aOic.VI IlmiThr" C:3 IIIWIMP • Must have the same 1 i 6-1/2"Min. ;_, ~. firestopping resistance (t0 ceiling) I se as adjacent wall. 9 4111. �:: li ✓ 1. Musthavethesameinsu- Firestop ' �j z, lotion as adjacent ceiling. Firestop y • Follow local rules regard- ` li=i — y ing framing construction. 68"Min. au iyi f J 6'8 Min.TZ ~ 1.�� I ' lip i� 42"Min. so dr II �, 7 Ft.Min. .r V') K� �'-i Non-Combustible Q �I '%%��� Facing au I fr ;,// t \\\1\\1 r] Drywall or ���� y go'/�� Any Rigid IHHMMMlill:, Material I J a, ✓ 0.: ,i \\\ D\,, V 1/2"Plywood 2"x 4" ® ,t t�Gravity Vent Kit(optional) Outside Combustion Air Kit(standard) CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements 12"Max. (305mm) ‘,e for a safe installation: Z Side wall:17"(324:: T::: oet : ::;: ) d frm th Areawhwood ng:6'8" Mantel can be fireplace. installed Fireplace enclosure: �i„ Bottom: 0" `-i-a. Sidt.ne: 0"to spacer , •/ �i�i 4111111111 . Back: 0"to spacer �1. i E 42"Min. , = -e 45 Deg. Top: Do not fill the space above the fireplace with any material 4" (Except the wood framing) 17"Min. Hearth Chimney:2"(50 mm) Extension 36" "Mantel:42"(1067 mm)measured from the base of the replace.fi 18" �„„/"- Y Non-Combustible Material Printed in U.S.A.©2013 Innovative Hearth Products P/N 900161-00, REV.B, 04/2015 Page 2 of 2 uperior • WCT6820 - ' u - -e _. _-'-•'::---:---'-:-: - '!' ''':: ,- - F REP LA CES - _ ,,, Our rRarne is our promise. yam ;J. ` 6�rY` $ J � z - - '' t:';;-::::"''-' '-'''''-,,,- '."5"; a _ # i % , 'tdi am: • f . A i 3 J 6 � h .. '-1 "le2 At ,F - K +' } eft .> 'V Aires ,1 k r, y f _y Buz ,. � ''44 TRADITIONAL - -- gefficiency, burning fireplacebeautifully;.. High EPA-certified wood combines the craftsmanship of a traditional masonry fireplace with clean and powerful non-catalytic combustion heating. x r 4 BF elm s � i _tan 7,�R FEATURED WCT6820 shown with White Stacked Textured Panels and Smooth Facade and door EXCLUSIVE FEATURES 4 Circulating design features facade,arch door and ceramic glass for optimum heat transfer 4 EPA phase II certified and Washington State approved wood heater 6 2.0 cubic foot insulated firebox that accepts up to 19"log size for increased performance White stacked textured refractory panels with integrated ash lip and decorative cast iron log retainer 4 Air combustion control for variable heat output with air boost for faster wood ignition during startup Includes insulated outside air kit(required for use) 4 86.6%Thermal efficiency and heats up to 1,500 square feet* 6 Efficient air wash system that keeps glass clean Cast or steel door available with heat resistant door handle that stays cool to the touch Includes heat activated 200 CFM UZY 5 variable speed blower for time-delayed heat distribution HeatFloTr^air kit and/or thermostatically controlled forced air kit available(three maximum outlets) m dl Durable high temperature paint finish 6 Uses SCIL(ACBI)6"air cooled wood burning chimney 01. Uses SCIL(ASHT/HT6103/S-2100/HT6000)6"insulated wood burning chimney 4 20 year limited warranty __ • MULTI-ROOM HEATING OPTIONS The WCT6820 wood burning fireplace can be used to heat multiple rooms within your home with our HeatFIoTM air kit option.Through natural convection or with the aid of the heat-circulating fan,warm air can be directed up to 10 feet away into one or two adjacent rooms,giving you the flexibility to heat up to three areas. Heat the family room with the fireplace,and the dining room and upstairs bedroom with the HeatFIoTM air kit.Or you can choose to more efficiently heat a large space by directing heat through multiple vents. INTERIOR DOORS FACADES (Standard) (One required) (Required) Air S.stY il+ 'L '�d. White Stacked Cast-Iron Smooth Smooth • ADDITIONAL ACCESSORIES ENGINEERING FEATURES AND SPECIFICATIONS c Cast Iron or Smooth Door(One Required) * Smooth Facade(Required) Chimney* (uses 6°ACBI, i HeatFlo Air Kit -- - ASHT,HT6103, n (optional)• Rigid Fire Screen s-2100or f; - 1 -_ - __ _ ._ _. e, „��._,a,�L.-.,�,,.s�g�a HT6000 wood burning chimney) e O HeatFloT""Air Kit 0 Forced Air Kit c O Variable Speed Switch for Blower V f il Insulation - - d: Flue 4 'Y Convection Exhaust - Air Outlet Stainless Steel Secondary Air Tubes BURN RATES* ->.. t -, $ . Air Wash System Secondary Air ',.-1.,...,,,,-¢1-{ • '`4s ,. Combustion • $ t -S ,, _. i—'s Radiant r {r - j ,d' Heat 800°F- Textured * 6 i - Refractories Cast Iran Log Retainers Combustion Air J _ 600°F- 'e _Convection • Air Inlet i4 �` , Outside _ Air Intake ::::: t Air Control** I:-i1 1 2 3 4 5 6 7 8 *Air-cooled chimney not recommended for use at elevations above 4,000 feet or in climates where temperatures will fall below 32°Fahrenheit(0'Celsius). HOURS Double doors shown available on WCT6840 only. **Air-cooled chimney not recommended for use at elevations above 4,000 feet or in climates *Results obtained by burning 2516s,of dry maple wood.(one hour pre-heating) where temperatures will fall below 32°Fahrenheit(0°Celsius). APPLIANCE SPECIFICATIONS INSTALLATION SPECIFICATIONS Front View Venting 6"ASHT Wood 3E31- burning chimney I \ A r A _ OWetGdll 42-/16*" I 1 r 36-in6' li11iMiIIIIIIIIIIIIIIIIII�i.IIl UI ' (3.lm) 11.1111111111111111111 I, " 13"x 13" — Max. IIL 11_r.�11.711111 <OWetGrly a(330mm x 33pmm)� 1 36" I 10 a Max. — — M Z Top View (— 28-1/8' Maintain at least 6-1/2" ) (160 mm)clearance from 4-5na ¢3/4" 9-3/4" Venting the outlet grill framing to a —�� 6^ASHT Wood a combustible ceiling, I i i; burning chimney ,r side wall or mantel. 113n6'III 1� f - kII 1a»e re �� Z snomo , I2a16n8" '_. IDouble doors shown 0 available on WCT6840 only. El El so. �ockout for gravity ducting l+ PRODUCT SPECIFICATIONS Left Side View Right Side View Knockout for Knockout for Glass Viewing Area(W x H) 22-1/2"x 12-1/4" forced air forced air (side or rear) ' , (side or rear) Firebox Interior(W x H x D+) 22"x 11-3/4"x 12" Interior Cubic Feet 2.0 IIMaximum Log Size 19" (11 `I IChimney Size 6" EPA Rating 3.7 grams/hr BTU's 55,000 II i8-tfir to-toe' Heating Capacity(up to) 1,500 sq.ft. � Thermal Efficiency 86.6% — :!sll '6- 111 rev. .c 3-13n6' 15-1/r oerstaeairmhke Junmeneu. 13-a/r Blower 200 CFM 15-15/15. $$ ts-Va Weight 3031bs- +Measured in front of door IMPORTANT NOTES: As with any fireplace,this appliance is extremely hot during operation.Read and understand all operating instructions before using this appliance.For further information,consult your dealer. Local conditions,such as elevation and choice of fuel will affect overall appearance of the fire and heating performance.Performance can also vary with home design and insulation,ceiling height,accessories chosen and appliance location. Diagrams,illustrations and photographs are notto scale—consult installation instructions Product designs, materials,dimensions,specifications,colors and prices am subject to change or discontinuance without notice. 6 uperior FIREPLACES® PFS.� NFf. ©2018 Innovative Hearth Products Visit us online ® 785565M 10/18 SuperiorFireplaces.us.com Ca"US Report#F14-199