Loading...
2009-559 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 (zt Community Development- Building &Codes (518) 761.8256 I F 1 4.'TE OF 0CCUP- -AZ-T(]Y Penn it Number. P20090559 Late Issued: Monday, March 01, 2010 This is to certify that work requested to be done as shown by Permit Number P20090559 has been completed. Location. 34 TWICWOOD Ln Tax Map Number. 523400-296-009-0001-033-000-0000 Owner. JAMES & LESLEY CONWAY I Applicant: 3AMES & LESLEY CONWAY This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DUES NOT relieve the property owner of the responsibility for compliance with Site Plan, Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20090559 Application Number. A20090559 Tax Map No: 523400-296-009-0001-033-000-0000 Permission is hereby granted to: ,TAMES &LESLEY CONWAY For property located at: 34 TWICWOOD Ln in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: JAMES &LESLEY CONWAY Residential Addition $35,000.00 34 TWICWOOD Ln Total Value $35,000.00 QUEENSBURY,NY 12804 Contractor or Builders Name/Address Electrical Inspection Agency Plans &Specifications 2009-559 520 sq ft resideintial addition PERMIT FEE PAID- THIS PERMIT EXPIRES: Saturday,December 04,201V (If a7onger period is required,an application for an extension must be metre to the code Enforcement Officer of die Town of Queensbury before the expiration date.) Dated at the T Queers urt, F ,December 04,2009 s!y SIGNED BY w n for the Town of Queensbury. Director of Building&Code Enforcement _ c)rrlcr tlsrc,Nl v J TAX MAP 1 3 TAX NO 2009 FEES PERMIL---- 10-CP1 AI1()r,J 1 rd1 IrN 1 !'IIlr'• l (1 1 ry `" (If a1+I)IIrrih1n) PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUA CE++OF A VAAt.I,D PERMIT FOR CONSTRUCTIO-�N..' Q _ APPLICANT/BUILDER: tA1I t Wfl t�idy) OWNER:11 I h1 L� ���e L-C7rl W4. ADDRESS:5+ �Q� 1`dCi !'+F ADDRESS � 1 i c oxod /�..&h el �•I'S PHONE NOS. [ g'033 F --P�H-�ONE NOS. /61 V 7�a CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: 1 0VK 1 rgC-kf-PHONE:OZoZ�I' 0p 7 LOCATION OF PROPERTY: `t _71A) I CW O0 k-a h SUBDIVISION NAME: PLEASE INDICATE MEASUREMFNTS AS REQUIRED BELOW CHECK ALL THAT z APPLY TO YOUR z p C3 Ct w r; PROJECT p 00 1= a o z z w �„ LLLL u1 Q v.p U Q Ill o -" c1 z c7 1_ o1 w z <[ Q U) N O LL I LL a 2 of SINGLE FAMILY X I LO O rl O �6 TWO-FAMILY p� MULTI-FAMILY(NO.� TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER jf1t1'11 f�� `)NlV'ltti111J1"1/ l 1111111111111/IJ I rl't'1'1r''•11N'II/ r )'�/r i' 1 ;n/ r 11, 1 11lr'r'r; J,711I/ ' ! „rfl IF COMMERCIAL OR INDUSTRIAL—NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST:V5/ D D D FUEL TYPE. HEAT TYPE? h 0+IJ 44'eF>HOW MANY FIREPLACE(S) AND/OR,WOODSTOVES(S): ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? IS THIS A HISTORIC SITE? nn PROPOSED USE OF BUILDING OR ADDITION: r6LMI l 1 y IOo M }s Poo r, W6LIkin C/ose.f- 2'na( Float ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office 1 acknowledge no construction activities shall be commenced prior to issuance of a valid permit. i certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, i or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read a,q agree to the above. Signed (" Director of Building & Codes. 761-8256 (for questions QUESTIONS? CALL 761-8256 OR EMAIL regarding Building Permits, construr,lion code-, or septic_. /' code_s treenshurv.net systems) t VISIT OUR WESSITE FOR MORE INFORMATION Zoning Administrator: 761 821£3 (for questions regarding www.c#ueensbu,ry.net required permits, the permit process, application requiremenl^ r)l I() schedule an appointment) .____- . . . . . . ; This application/proposed action described Permission is hereby granted to the above herein is found to be in accordance with the ; Applicant to erect or alter the building described zoning Laws of the Town of Queensbury. herein in accordance with said Application: ZONING APPROVAL DATE - BUILDING &CODES APPROVAL DATE 1,011,11 of l< I(rclfSlrifI if - ( (1111nof111111 I !rr•r•/0/MJ4'11l f !f(h I I`oit l , ,rrl 1I11T)r .l1111 y OP T l CONSTRUC JOB_(soint j u / A Div.Of O'V CO SHEET NO. 3!j 7Lw e-LA)Oo d L N OF /7lGrecFtt Management Corp. CALCULATED BY--#6 A DATE 51 CROWLEY ROAD/HUDSON FALLS,NY 12839 (518)798-0338 FAX:(518)798-0338 CHECKED BY DATE SCALE -- Z0t r"OKWO A$a-w evidence of, 1°a�s;cells;:gees, fences,etc., 1p I � - � o f i�1 � 47 1101 + i c w o o-D R � 20 � i Queensbury Building & Code Enforcement - Residenti;�ii W Inspection "�frtce No. (518)761-8256 Arrive: am/pmDepart: /pme Inspection request received: inspector's initials: NAME: PERMIT#: LOCATION: DATE: Z— TYPE OF STRUCTURE: - Comments: N a 4' Building Number Address visible from road Chimney Height/"B'Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors _ Handrail 4 or more risers Guards at stairs decks tios more than 30 inches above Weds Guard at stairwell at 34 inches or more Guard at deck pqLches 36 inches or more Handrail Termination at Newell Post or Wall interior/Extedor Railin s 34 inches to 38 inches Deck Bracing I Handicapped Ramp Compliant Grade TM from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off gg2sed/re ulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety lain /Window in stairwells 9jeA glazing Interior Smoke Detectors/Qarbon Mo oxide Detectors Every levee: EveryBedroom: Outside every bedroom area: Inter Connected: Battey backup: .� Attic access 30 inches x 22 inches x 30 inches(Wight)in accessible area Crawl Spaces 18 inch x 24 inch access 1 scl.ft:150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/insulation Certification ` Floor truss,draft stopping finished basement 1,000 N.ft. , ------------ Emtrgency egress below grade Gas Fumace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler ' Relief Valves installed/Heat Ira Water Temp 110 Enclosed Stairs Sheetroc k Underside minimum W Gypsum Basement stairs dosed rise>4 inches Garage Floor Pitched Garage fireproofing I%hour fire door/door closer Duct work Seated Gas Loge in Seated or Glass Enclosure Final Electrical Final Survey Plot Plan � Are Fault Breaker in Bedrooms Flex Gas P'De Bonding As Built S is System/Sewer Dept. Inspection Sticker L@ood—Plain Plan i Variance_.required Certification,if re aired �,.,^to issue C/C or C 10 Tem ora /Parma nent L:tBuilding&Codes FormslSuilding&CodeMinspection FonnsWesidential Final Inspection Form revised 1 January 7,2008;Revised 6/26/OS06.do Rgyig� ^` _A, 144 Queensbury Building & Code Enforcement - Resl enti final inspection Qffte No. 518 761-8256 Arrive: am/pm, part.: --�m/pm Date Inspection request received: Inspector's Initials: NAME: PERMIT#: _ LOCATION: J 7 DATE: TYPE OF STRUCTURE: Comments: Y N / ,V Building Number Address visible from road Chimney Height/"B°Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbina Vent through roof minimum 6 inches Roof Co fete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks ios more than 30 inches above grade Guard at staiiwelf at 34 inches or more Guard at deck,p2rches 36 Inches or more Handrail Termination at Newell Post or Wall interior/Exterior Railings 34 inches to 38 inches Deck Bradn /Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed/r ulator 18 inches above grade Interior priM i trim/doors/main entrance 36 inches Bathroom I Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches hei ht in accessible area Crawl Spaces 18 inch x 24 inch access 1 N.ft.-150 .ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/Insulation Certification Floor truss,draft eta ing finished basement 1,000 sq.ft. Emerg9M egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap!Water Temp 110 Enclosed Stairs Sheetrodk Underside minimum W Gypsum Basement stairs dosed rise>4 inches Gar a Floor Pitched Garage fireproofing/%hour fire door/door closer Duct worts Sealed properly Gas Logo in Seated or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gie-Ape Bonding As Built Seoic,system/Sewer-Dept,Inspection Sticker Site Plan /Variance re wired Flood Plain Certification,if re uired Oka to issue C I C or C 10 1 Temporary/Permanent L:\Building&Codes Forms\Building&Codes\lnspectian Fam Wesidential Final Inspection Fom� revised 9 dos;Revised January 7,2008;Revised 6/2&W 00�, -3 Rough Plumbing / tneuiatio Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: am/pm Depart:Aamipm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: PERMIT #: LOCATION: INSPECT ON: ~' — TYPE OF STRUCTURE: 7 Y N NIA Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 %inch minimum Drain Size Washi Machine Drain 2 inch minimum Cleanout every 100 feet/chan a of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Wa ly Piping Head 0 .S.I for 5 minutes Insulation! idential Check/Commercial Check jyvek or ilar Exterior Sealant r ent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated Eppaces Combustion Air Su for Furnace uct work sealed pr ed I No duct to NTS. r faougn Numbing rnsu&m0"Repr�'Crrevmd Akw 172003, jvvaJd 155�200, �'' Y tea'�tar�►1�� Framing / Firestopping Inspection Report ice No. (518)761-8256 Date inspection request received: lueensbury Building&Code Enforcement Arrive:am/pm . rt: I am/pm 42 Bay Road, Queensbury, NY 12804 Inspector's lnitial DAME: r0K LA I PERMIT#: _OCATION: O INSPECT ON: TYPE OF STRUCTURE: Y ,f A COMMENTS: Framing Attic s 22" x 30" minimum _ Jack Studs/Headers ` �- Bracing/Bridging +✓ _ <- ,r Joist hangers Jadc Posts/Main Beams Exterior sheeting nailed properly 127 O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 % w 16 gauge 8 16D nags each side Draft stopping 1,000 sq. ft floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in 2@vq min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 518 inch Type X Ceilingtwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf grade L:13uHdbV&Codes Foffns.=iBui hV&Codesunapection FOM'Ftarrdrp FkssWppkV Inspection R"NUac R,ybW JO"70 2008 Framing / Firestopping lns Report Mice No. (518)761-8256 Date inspection request received: tusenstwry Building&Code Enforcement Arrive: amlpm Depart:/j am/pm '42 Bay Road, Queensbury, NY 12804 Inspector's initials: VAME: PERMIT#: LOCATION: INSPECT ON: Z- TYPE OF STRUCTURE: f A4)f Framing Y N NtA CQMMENTS,. Attic Access 22'x 3W minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed property 12'O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %Uw 16 gauge 8 16D naffs each We Draft stopping 1,000 sq. ft, floor trusses Bolts ft. or less on center lee and water s ield 24 inches from wall ` e se n 1, 2,3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 Inch insulation in ca &min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X C!!9 It Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 sf greds L:113ugdbv&Codes Forms-oLD\w ft&codesu apec&m Fomi0WMVft Fkastoppft ln$WxUon Repa da,V �. �rRON (TUE)NOV 10 ZOOS 8:UO/ST. 8:ISOZM .760000OZ88 P 1 REScheck Software Version 4.2.2 Compliance Certificate Energy Code: 2007 New York Energy Conservation Construction Code Location: Warren County,New York Construction Type: Detached 1 or 2 Family Heating Type: Non-Electric Glazing Area Percentage: 7% Heating Degree Days: 7635 Construction Site: Owner/Agent: DesignedContractor: Compliance:19.6%Better Than Code Ma)dmum UA:92 Your UA:74 Gros- C_Ivity cont Glazing UA Ceiling 1:Flat Ceiling or Scissor Truss 368 38.0 0.0 1 f Wait 1:Wood Frame, 16'o.c. 5" 21.0 010 30 Window 1:Wood Frame:Double Pane with Low-E 39 0.310 12 Door 1:Solid 20 0.180 4 Floor 1:All-Wood JoisftT'russ:Over Unconditioned Space 368 19.0 0.0 17 Furnace 1:Forced Hot Air 78 AFUE The proposed building represented in this document is consistent with the building plans,specifications,and other calculations submitted with this permit application.The proposed systems have been designed to meet the 2007 New York Energy Conservation Construction Code requirements.When a Registered Design Professional has stamped and signed this page,they are attesting that to the best of his/her knowledge,belief,and professional judgment,such plans or specifications are in compliance with this Code. ifEyrw HAKE rs &Av Name-Name-Titles Signature Date �{{+ l.� `•to ;�«� t =a 06 Project Title: Report date: 11/06/09 Data filename:CAProgram FIeakCheddRESchecktconway.rck Page 1 of 4 fFROM (TUS>NOV 10 2008 8:SOfST. 9:UOZHo.71500000298 P 2 REScheck Software Version 4.2.2 Inspection Checklist Ceilings: ❑Ceiling 1:Flat Ceiling or Scissor Truss,R-38.0 cavity insulation Comments: Above-Grade Walls: ❑ Wall 1:Wood Frame,16"o.c..R-21.0 cavity insulation Comments: Windows: ❑ Window 1:Wood Frame:Double Pane with Low-E,U-factor:0.319 For windows without labeled U-factors,describe features: #Panes Frame Type Thermal Break? Yes_No Comments: Doors: ❑ Door 1:SoNd,U-factor:0.180 Comments: Floors: ❑ Floor 1:All-Wood JoistJTruss:Over Unconditioned Space,R-19.0 cavity insulation Comments: Heating and Cooling Equipment: ❑ Furnace 1:Forced Hot Air:78 AFUE or higher Make and Model Number. Air Leakage: Joints,penetrations,and all other such openings in the building envelope that are sources of air leakage are sealed. ❑ Recessed lights are 1)Type IC rated,or 2)installed inside an appropriate air-tight assembly with a 0.5"clearance from combustible materials.If non-IC rated,fixtures are installed with a 3"clearance from Insulation. Vapor Retarder: ❑ Installed on the warm-In-winter side of all non-vented framed ceilings,walls,and floors, Materials Identification and Installation: ❑ Materials and equipment are installed in accordance with the manufadurWs installation instructions. Materials and equipment are identified so that oompliarwe can be determined. ❑ Manufacturer manuals for all Installed heating and cooling equipment and service water heating equipment have been provided. ❑ Insulation R-values and glazing U-factors are clearly marked on the building plans or specifications. Insulation is installed according to manufacturer's instructions,in substantial contact with the surface being insulated,and in a manner that achieves the rated R-value without compressing the insulation. Duct Insulation: Duds In unconditioned spaces or outside the building are insulated to at least R-8. Duds in floor trusses above unconditioned spaces or above the outdoors are Insulated to at least R-6. Duct Construction: AN joints,seams,and connections are securely fastened with welds,gaskets,mastics(adhesives),mastic-plus-embedded-fabric,or tapes.Tapes and mastics are rated UL 181 A or UL 181 B. Exceptions: Project Tile: Report date: 11/06/09 Data filename:C:Wrogram FileMChecklRESchecklconway.rck Page 2 of 4 FROM fTUe>MOM 10 2000 8:50/ST. 8:00/Mo.7600000288 P 3 Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in.w.g.(500 Pa). D The HVAC system provides a means for balancing air and water systems. Temperature Controls: Each dwelling unit has at least one thermostat capable of automatically adjusting the space temperature set point of the largest zone. Electric Systems: 0 Separate electric meters exist for each dwelling unit. Fireplaces: I] Fireplaces are installed with tight filling non-combustible fireplace doors. • Fireplaces have a source of combustion air,as required by the Fireplace construction provisions of the Budding Code of New York State,the Residential Code of New York State or the New York City Btdiding Code,as applicable. Service Water Heating: ❑ Water heaters with vertical pipe risers have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or Is part of a circulating system. 0 Circulating hot water pipes are insulated to the levels in Table 1. Circulating Not Water Systems: Circulating hot water pipes are insulated to the levels in Table 1. Heating and Cooling Piping Insulation: Q HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F are insulated to the levels in Table 2. Swimming Pools: • AN heated swimming pools have an onioff heater switch and a cover unless over 20%of the heating energy is from non-depletable sources.Pool pumps have a time dock. w Project Title: Report date: 11/06/09 Data fileneme:C:Trogram FlleslChecklRESchecklconway.rck Page 3 of 4 -vFROM (TUE)NOV 10 2008 0:51/ST. S.50fNo.7500000295 P 4 Table 1:Minimum Insulation Thickness for Circulating Not Water Pipes Insulation Thickness In inches by Pipe Sizes Non-Circulating Runouts Circulating Mains and Runouts Heated Water Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" Temperature("F) 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2.Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness In Inches by Pipe Sizes Piping System Types Range("F) 2"Runouts 1"and Less 1.25"to 2.0" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(for feed water) Any 1.0 1.0 1.5 2.0 Coating Systems Chilled Water,Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD:(Building Department Use Only) Project Title: Report date: 11M/09 Data filename:C:1Program FileMCheck1REScheckloonway.rck Page 4 of 4