Loading...
2008-026 TOWN OF QUE E NSBURY Foero 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number: P20080026 Date Issued: Friday, May 09, 2008 This is to certify that work requested to be done as shown by Permit Number P20080026 has been completed. Location: 38 HOWARD St Tax Map Number. 523400-301-020-0001-036-000-0000 Owner. LARRY CLUTE Applicant: HAROLD POTTER This structure maybe ocplaaN,TERPRISES, INC. Garage - 2 Cars Attached By Order of Town Board Single Family Dwelling TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, (7.2)41494 Variance,or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals, TOWN OF QUEENSBURY ` 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development-Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080026 Application Number. A20080026 Tax Map No: 523400-301-020-0001-036-000-0000 Permission is hereby granted to: HAROLD POTTER CLUTE ENTERPRISES, INC. For property located at: 38 HOWARD St in the Town of Queens bury;to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: HAROLD POTTER 38 HOWARD St Garage-2 Cars Attached QUEENSBURY,NY 12804 Single Family Dwelling $100,000.00 Total Value $100,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2008-026 936 SQ FT SINGLE FAMILY DWELLING AND 400 SQ FT GARAGE $152.32 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,January 28, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To o eensb , g,n‘f.- nuary 28,2008 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement 0 o r .2 0" f- f OFFICE USE ONLY f �.. Date { kj 6.`: TAX MAP NO. PERMIT NO. �/� i ; FEES: PERMIT RECREATION ENGINEERING $ Stainp (If appit le) i PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMITMUST BE OBTAINEDBEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VAUD PERMIT FOR CONSTRUCTION. AI PLICANTIBUll.DER. e -:Er-t NNE: 'P' r' (-0 ADDRESS: _ ��.�.�,� � ADDRESS - �. PHONE NOS. ' -7-D'7 7 PHONE NOS; CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: Lc-i -Li PHONE: (c't LOCATION OF PROPERTY: SURD ION NAME: - PLEASE INDICATE MEASUREMENTS AS f EQIJIREP BELOW: CHECK ALL THAT APPLY TO YOUR C$ 5.1t,0 U) PROJECT . ot SINGLE FAMILY C_ C-- t t, 11 TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED L GARAGE ) -]Co OTHER IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: 1 C G,C)a 421 ICI TVOIC. I =P ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? \".------ _ , e--- •Th ARE THERE EASEMENTS ON PROVRIY1 N --- , • ... , . .,... ..- . - -,- - --, - • ' I acknowledge no construction totiAlltiestiall be commenced prior to issuance of a valid permit I certify that the application, plans, and supporting materials are a tnielmd complete statementklescription of the work proposed,that all work will be perfonned in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand thatl/we are required to provide an milt survey by a licensed land surveyor of all newly constructed facilities pricrtolice of a certificate of occupancy. I have read and Wee to the ve ) /.. Signed ' -- birerpiqliiklit&ptliltis;461-8256 iforquestrons regarding.Building Permits, construction codes Or sePtic siaterns) Zoning Administrator. 761-8218 (for questions regarding required permits, the permit process, application requirements or to Schedule an appointment) • 4 Ar*O •* 4 i 4 0 • 4 0 4 1 Permission is hereby granted to the above , : This application I proposed action described Applicant to erect or alter the building herein is found to be in accordance with the : described herein in accordance with said ; ; zoning Laws of the Town of Queensbury. , ',. Application: 4 1 f f f 0 1 f $ 4 t I I 4 4 I 11 I 4 - f 0 t 1 1 1 0 4 BUILDING&CODES APPROVAL , # ; ZONING APPROVAL. . i ', . . 0 0 l 4 1 t DATE DATE 4 4; ;4 4 • . • • VISITCMSIMNOUR WEBSITES 7 CALLEC:10A40:56rVINSO.CflnetEMA:MATION d 0 4 CcOdeftefteenSbU WWW4SISIAtblinlytet .---'----"*%."-') r : OFFICE USE ONLY PROJECT NAME: • STAFF INITIALS: I BUILDING PERMIT SUBMISSION ;• DATE: } CHECKLIST FOR: SINGLE FAMILY DWELLING t. ,JBuiiding Permit Application Completed? YES NO I N/A 2 Energy Form or CheckMate Energy Code Compliance Forms Complete? (2-copies) 3 Energy Code Inspector's Report from Checkmate 1 Program? (2-copies) i 4 Septic application completely filled out? (if applicable) 5. Electrical Inspection Form complete? 1 6. Two (2) sets of the plans each of the following: YES NO 1 N/A a. Floor plans (s)? b. Foundation plan? c. Cross sections (s)? d. Elevations? I { e. Window and door schedule? g. Plans signed and sealed by registered architect or engineer? 1 h. Window and door schedule? 1 ! Two (2) site plans showing location of the structure to be 7. built, location of well or water lines, location of septic system or sewer line? 8. Setbacks from property tines to new structure? Setbacks to neighboring wells and septic systems, 8. including onsite well and septic systems (if applicable)? 9. Driveway Permit? Town of Queensbury- Community Development Office- 742 Bay Road,Queensbury,NY 128C • PROJECT NAME: ; ©FFlt usE ONLY , STAFF INITIALS: , BUILDING PERMIT SUBMISSION , DATE: ; CHECKLIST FOR: MULTIPLE.DWELLING or.CO IIMERCIAL PROJECTS 1. Building Permit Application Completed? YES NO N/A 2 -Energy Form or CheckMate Energy Code Compliance Forms Complete? (2-copies) 32.. Energy Code Inspector's Report from Checkmate Program? (2-copies) I I A Septic application completely filled out? (if applicable) 5. Electrical Inspection Form complete? t 6. Two (2) sets of the plans each of the following: YES NO I N I A 1 a. Floor plans (s)? i b. Foundation plan? Ic. Cross sections (s)? d. Elevations? e. Design loads including floor, snow load, and wind 1 I load? If. Seismic design (required after January 2003)? g. Plans signed and sealed by registered architect or Iengineer? h. Window and door schedule? Two (2) site plans showing location of the structure to be 7 built, location of well or water lines, location of septic system or sewer line with all setbacks and separation distances shown, and all improvements to the property? 8. Solid Fuel Burning or Gas Appliance Form (if applicable)? 9. Driveway Permit Town of Queensbury- Community Development Office= 742 Bay Road,'Queensbury,NY 12804 A. 0 D Z I 1 1 = I 3 il a 4 } Z9 a` S i t } a e 1 4 t S k t7i et Y t 3 e k z t t t�' I 4 ia n Az` i I ��kl 3� 3o f ,\ c.-.A.... . \O .. i i f Warren County Spatial Data Viewer - 3$ Howard a F. I Pa Re 5 • ❑ PA _ Ae r. 411 idii4i, -itk,,.4k,-,i..,-,:,..-;,-4:,,•,,,_-- -----,.—,--:-_„,.,,-,-,,_-,,,.*.-.-' t.r....'.„.---7.3- 4„,,t-,.,,4 1t_!._--,,,,:- ::4.- ,i„,-•",i:-,,i_...ii-,.,,:it,-r:,-..,-i--.:---"l...-t_-1 i.if-:_:--_t ti'.l.l_it-.. ::..,.,,:._.,..-_ 7,,,,,4,,,i1:,,.'i..::.2..,- , ::::.,,. „7,,;,:,,.,..itiet,.., 4, ,$jam.. ."_YAP' J'M e i r rk 759 ,t,p. li.ttp o —ol& Iiiiiiilt 0 O lit d EII \ us dZYv n U, ° ,Z l YA. Z dN o- 0 © coto YA. pyi1lt01I 11* *a*$ ILW J �' T..A (I. g, Alil 1 i 4. .d. VI ,t d2 0 VII cc o o Pic 0 Wi . .' '*' ' r (644.VA .;(1' J;rr fo' te ill .. Ot r 3 • p o a 0 a % T .., d) ili ytt 1 N % \It** ° •s © tor_a Oo 44 yj0 Z c) ,w 3 , f 30 OFFICE USE ONLY ' TAX MAP NO. PERMIT NO. ` ERMIT FEE ; , , ' APPROVALS: ZONING TOWN CLERK t, t t. • tt • APPLICATION FOR, SEPTIC DISPOSAL SYSTEM PERMIT; A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT. atANER: —\\- (CA 3\e INSTALLER: C.-,,A Ski.--„ t` , t;--.-`C ADQRI �f': �.. � �i - ADDRESS' PHONE NOS. PHONE NOS. --7't `T: -7 -7 LOCATION OF INSTALLATION: . ? i` r`:`.... c_.4 .. RESIDENCEINFORMATION: NM= BE oms COMPUTATIma is TOTAL DAILY FLOW GARBAGE GRINDER r-,� 1880 or older 180 gallon per bedroom INSTALLED?-- • =11M 130 gallon Per bedroom illi SPA OR HOT TUB r'A 1892-prevent X 110 gallon per bedroom = aD i INSTALLED? %--'"= PARCEL,INFORMATION: TOPOGRAPHY: FLAT ROLLING STEEP SLOPE %SLOPE •✓ eOI`NATURE: SAND ' LOAM CLAY OTHER, ✓ GROUNDWATER: AT WHAT DEPTH? ¢EDROCKIIMPERVIOUS MATERIAL: AT WHAT DEPTH? • DOMESTIC WATER SLR 'l-Y: MUNICIPAL e"_. WELL r (IF WELL:WATER SUPPLY FROM ANY SEPTIC-SYSTEM ABSORPTION IS FT. ) PS ✓ PERCOLATION TEST: RATE IS PER MIINUTE PER INCH (TEST TO BE COMPLETED BY A LICENSED PROFESSIONAL ENGINEER OR ARCHITECT) PROPOSED SYSTEM FOR NEW CONSTRUCTION: All individual sewage disposal systems must be designed by a licensed professional engineer or architect(unless installed in a Planning Board approved subdivision).Add 250 gallons to the size of the septic tank and leach field for each garbage grinder,spa or whirlpool tubs I SEPTIC TANK: COl 0 GALLON(MIN.SIZE IS 1,000 GAL.) TILE FIELD:EACH TRENCH 5 O FT. ✓ TOTAL SYSTEM LENGTH: (` 2 e FT. SEEPAGE PIT(S):HOW MANY? ✓ SIZE OF EACH FT.X FT. I SIZE OF STONE TO BE USED;# " /DEPTH OR THICKNESS FT. ✓ J3ED SYSTEM SIZE: X • ALTERNATIVE SYSTEM: LENGTH AND/OR SIZE I HOLDING TANK SYSTEM:(If required)NO.OF TANKS: I SIZ€OF EACH 1 GALLONS./TOTAL CAPACITY: GAL. NOTE: ALARM SYSTEM AND ASSOCIATED ELECTRICAL WORK MUST BE INSPECTED BY A TOWN APPROVED ELECTRICAL INSPECTION AGENCY. PLEASE REVIEW LIST PROVIDED. For your protection,please note that pursuant to Section 136-29 of the Code of the Town of Queensbury,any permit or approval granted which is based upon or is granted in reliance anon any MAtAreal ms..^---- -" failure to mate A mM c r4 1 4,^ea4„- —••----. -10 /IVIo Queensbury Building & Code Enforcement - Residential Final Inspection Offi o. (518)761-8256 Arrive: __/..4,:___Vn/pm‘ /p am/pm Date Inspection request received: inspector's Initials: 01—' NAME: 7 PERMIT#: CIF-— LOCATION: � t� �� -= DATE: , � ---� - - U � r�- $ TYPE OF STRUC RE: Comments: Yes No N/A 4" Budding Number Address visible from road Chimney Height/"B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches . Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more . Handrail Termination at Newell Post or Wall Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 8 inch clearance to sill plate _ Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy I trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety gig Interior Smoke Detectors I Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves)installed I Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum lh'Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'/.hour fire door/door closer Duct work Sealed property / 1 Logs in Sealed or Glass Enclosure / f inal Electrical / �/ Final Survey Plot Plan V ‘'-(64/14 r 6 U�(/ f Arc Fault Breaker in Bedrooms . 7 flex Gas Pipe,Bonding As Built Septic System/Sewer Dept.Inspection Sticker Site Plan i Variance required Flood Plain Certification,if required Okay to issue C/C or C/O(Temporary/Permanent) / L:\Building&Codes FormssBuilding&CodesMnspection Forms\Residential Final Inspection Form_revised_100405.doc;Revised January 7,2008 `✓ Queensbury Building & Code Enforcement - Residential Final inspection J Office No. (518)761-8256 Arrive: 1 9-'.1 am/pm npart: am/pm Date Inspection request received: Inspector's Initials: (1. ' NAME: Clk) r PERMIT#: i ~' LOCATION: j.�- _�r. (S ' DATE: CO i TYPE OF STRUCTURE: Comments: Yes No N/A 4" Building Number Address visible from road -: Chimney Height I"B"Vent/Direct Vent Location �-'`' j Gyji ! it- X Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete I Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more Handrail Termination at Newell Post or Wall Intertor/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to sill plate Gas Valve shut-off exposed I regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.ft:150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. Emergency egress below grade Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furnace/Hot Water Heater operating Low water shut-off boiler Relief Valve(s)installed/Heat Ira•/Water Tern. 110 Enclosed Stairs Sheetrock Underside minimum W G I. m MINI� Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/'A hour fire door/door closer Duct work Sealed properly /11 Gas Logs in Sealed or Glass Enclosure Final Electrical Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding As Built Septic System/Sewer Dept.Inspection Sticker Site Plan /Variance required 1111 Flood Plain Certification,if required Okay to issue C/C or C/O I Temporary/Permanent j L:\Building&Codes Forms\Building&CodesMnspection Forms1Residential Anal Inspection Form revised_100405.doc;Revised January 7,2008 l0.-- Quee bury Building & Code Enforcement - Residential Final Inspection N. Office No. (518)761-8256 Arrive: 1-- ' am/pm Depart: am/pm Date Inspection request received: Inspector's Initials: . ,L_ NAME: ciii).-i,4_ PERMIT#:LOCATION: - 'r S -, DATE: g -0 TYPE OF STRUCTURE: Nl Comments:ti >r9;No_ WA �- 4' Building Number Address visible from road Chimney Height/-B"Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches �/� Roof Complete/Exterior Finish Complete ✓ Platform at all exterior doors Handrail 4 or more risers Guards at stairs,decks,patios more than 30 inches above grade / Guard at stairwell at 34 inches or more Guard at deck,porches 36 inches or more - Handrail Termination at Newell Post or Wall v� /Inter or/Exterior Railings 34 inches to 38 inches / Deck Bracing/Handicapped Ramp Compliant , Grade away from foundation 6 inches with 10 feet I 6 inch clearance to sill plate Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches /Bathroom/Kitchen watertight Safety glazing/Window in stairwells safety gig ,, / Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: Inter Connected: Battery backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access, 1 sq.tt.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation Floor truss,draft stopping finished basement 1,000 sq.ft. / Emergency egress below grade , Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Furace/Hot Water Heater operating Low water shut-off boiler /' Relief Valve(s)installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum W Gypsum i/ Basement stairs closed rise>4 inches l Garage Floor Pitched Y Garage fireproofing/'/.hour fire door/door closer Duct work Sealed prolperly Gas Logs in Sealed G Finclosure Final Electrical / Final Survey Plot Prei �j U P�h�k v�� Arc Fault Breaker in Bedrooms Flex Gas Pipe Bonding "-----A. D As Built Septic System/Sewer Dept. Inspection Sticker /' rkb(hoei. Lolubi/U(2 e A Site Plan /Variance required - /' G.r Flood Plain Certification,if required ,J/ Okay to issue C/C or C/O[Temporary/Permanent L:1Building&Codes Forms1Buiiding&CodesUnspection Forms\Residential Final Inspection Form revised 100405.doc;Revised January 7,2008 \ Final Survey Inspection Dept. of Community Development Town of Queensbury 742 Bay Road Queensbury,NY 12804 '4 Date received: 34 1546 e___ NAME: LLY9'&7- LOCATION: PERMIT#: 04e " go Final Survey Plot Plan Approved Denied The attached final survey has been received by the Dept.of Community cr Development. Upon review the survey has be ;• Al i Craig :rown, Zoning Administrator Notes: L;\SueHemingway\Building.Codes.Inspection.FORMS\Final Survey Zoning Administrator.doc $,r,�,'C ; C; �,l,.'�,'C; ;<; C ,; Qr,.'1,'�,�•.'�,'C;t,�,T',C; ,; C;:�C;�C;'�CZC�C.C;:�C:C�c.c.C.C.CSC.'CSC.C���C�C�C�<s\.t;C�C'.4c'�C.4<:St�c�N1C� ;'—gt 5\7 t<<?N. ) MIDDLE DEPARTMENT INSPECTION AGENCY, INC. �>> ti `��� cee/xlifzeo,that the electrical wiring to the electrical equipment listed below has been examined and is approved as ��%. (j) being in accord with the National Electrical Code, applicable governmental, utility and Agency rules in effect on the date << 4 noted below and is issued subject to the following conditions. 0,( Owner: Clute Date: 04/30/2008 0 0 Occupant: Unknown Location: 'i ���) 38 Howard 0 C�j Queensbury, Warren Co. NY <<S `) Occupancy: Single Family Dwg. <<>> (raj F —1 4. 4 Applicant: Don Beagle {�:' Asa ,, << ;� 1747 Hadley Hill Rd. x �% (raj Hadley,NY 12835 -14 4 _ A <<� 0 L C� Cep) @ � � % (. � Raymond A. Novakilxiamaw <; issms es L. � Equipment: a � Ar <<° ��) 200 -Amp. Service Equipment 4/0, - ch =® eptact 1 - fixtures -Dlshw her; 1 Dryer; 3 -20 C w) Amp. Receptacles; 2 Ventans �� C CCU) �� ;C.; 0 >> 77, a -, << (�,`) xx 0 << 0 - , 1,P. This certificate applies to the electrical wiring to the electrical equipment listed immediately null and void. This certificate applies only to the use,occupancy and % L;) above and the installation inspected as of the above noted date based on a visual ownership as indicated herein. Upon a change in the use,occupancy or ownership ( (��) inspection. No warranty is expressed or implied as to the mechanical safety,effi- of the property indicated above,this certificate shall be immediately null and void. 1��� ciency or fitness of the equipment for any particular purpose. This certificate shall In the event that this certificate becomes invalid based upon the above conditions, << be valid for a period of one year from the above noted date. Should the electrical this certificate may be revalidated upon reinspection by Middle Department , ����� system to which this certificate applies be altered in any way,including but not limit- Inspection Agency,Inc. An application for inspection must be submitted to Middle (N)) ed to,the introduction of additional electrical equipment and/or the replacement of Department Inspection Agency, Inc. to initiate the inspection and revalidation C any of the components installed as of the above noted date,this certificate shall be process. A fee will be charged for this service. MAP REFERENCE MAP OF A SURVEY MADE FOR LARRY CLUTE BY: VAN DUSEN & STEVES DATED: JANUARY 2004 LAST REVISED: SEPTEMBER 11, 2007 LANDS N/F OF GREEN a S81°29'45"E 178.73' N k W CRUSHED bn 5TONE DRIVE O W LANDS N/F OF + AREA PIDGEON I 17, 742. 77 sq.ft. o co 1 STORY -- 0.41 acres - N Z WOOD FRAMED - HOUSE ' \ o 0 M� o c 35.55' M N V) 176.42' N81°29'45"W LANDS N/F OF CONDON A." N',- sr a 'tMAlITE1ORILED ALTERAT OR ADDITION TO A SURVEY Da et Aprll 4, 2008n u 's ION � A UCUM LAND SLR2VEYMS SEAL IS A Map of a Survey made for Scale 1'=20' Q,� WMATM OF SECTION 7Mk SUB-WSION 2 OF THE C.X. NEW"MM STATE EDUCATION LAW ONLY COPIES FROM 7HE OPo'MEL OF THIS SMRS MARKED WITH AN aMEI OF THE LAND SURVEYORS SSHALLBE O ACCMM R�E , Clute Enterprise s WrIPMATIMS RDICATED HEREON SMN"THAT ' 7E95 SIJltVEY WAS PREPARED M ACCORDANCE MiN THE Land surveyors (ITNDL�aP�°C `��° E° BY THE IEYV YORK STATE A55017AT10N OF PROf1B51dIK LAND SL RVEVM SAID CERIFICATIOHS SHALL RUN ONLY TO THE PERSON FOR WHOM THE SURVEY IS PREPARED.AND ON NS BEHALF TO THE TITLE COMPANY.GOVERNMENTAL SHEEr'�:' 169 Haviland Road Queensbury, New York 12804 Af.4W AND`ErS O NE LE O LISTED N .' ""° Town of Queensbury, Warren County, New York m THE ASSIGNEE$aF THE IaHDMc MSiITUnON (518) 792-8474 New York Lie. No. 50135 Giute G22IGN0. DATE DESCRIPTION DWG. No. 95001_38 301.20- -36 + 7.1 / 20-1-9 + O ZllOci.. Zee 1 r Septic Inspection Report Office No. (518) 761-8256 Date Ins gn.ye- quest received: Queensbury Building &Code Enforcement Arrive: S am/pq1/2 ,Depart: am/pm 742 Bay Rd., Queensbury, NY 12804 Inspectors Initials. K-- NAME: L V t� � INSPECT ON: Air d A 7,0 LOCATION: 3 /�move° RECHECK: Comments and/or diagram Soil Type: Sand/ Loam/ Clay Type of Water: Municipal/Well Water Waterline separation distance _ ft. Well separation distance ft. Other wells: _ ft. Well Casing Length 50' + / - Y N N/A Absorption Field: Total length ft. Length of each trench ft. Depth of trenches ft. Size of Stone Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank Tank to Distribution Box Distribution Box to Field/ Pit Opening Sealed: Y N End Cap _Y _N Inlet/Outlet Pipes &Baffles Y_N Location/Separations Foundation to tank / ft. Foundation to absorption ft. Separation of Pits ft. el ��t Conforms as per Plot Plan _Y_N A - 6 Uf L, 0 Engineer Report and As-Built i Y_N Location of Syste Property: Front Rear Left Side Right Side Middle Front Middle Rear m e to : pproved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 06/18/07 L:\Building&Codes Forms-OLD\Building&Codes\Inspection Forms\Septic Inspection Report.doc 4. , - rc.)•' C) '031 i .. ..• -tfoil0i` 0 <:.-Y , -- ."6 , A , 1 It N --it i. . .A.-- ..., -..9 • , Am... ....3 , 3 17 % OS , Vt-?-• . ,..., . .....t.,, ,,, 1 • 1......i' •• „ . - • t u 10 ------ 1 ,,,r•77..1 ,,,,,,.,It,I,,. , •t,.. 1,1„ ..-.. . .• , ,..... ...11 ; C \iV 1 Z . , 0 M lirft =3 co c 14 itt ill i 11 -‹ 4-'.. I MM ..ii Hwill .s•./ , liCk ii -OKSch_A,/ . -- 77 / / Septic Inspection Report Office No. (518)761-8256 Date Inspection uest received: Queensbury Building &Code Enforcement Arrive: i . am/pm Depart: am/pm 742 Bay Rd.,Queensbury, NY 12804 Inspector's Initials: _NV NAME: /L) ( . PERMIT NO.: �f' LOCATION: tP. b, INSPECT ON: RECHECK: `, Comments and/or diagram Soil Type: / lay Type of Water: units / Well Water Waterline separation distance ft. Well separation distance `ft. Other wells: ft. Absorption Field: Total length ft. Length of each trench ft. Depth of trenches -.--- - ft. Size of Stone 1./ Seepage Pits: Number Size: x Stone Size: Piping Size Type Building to tank � 1 440 Tank to Distribution Box P '64 e '3 6-- Distribution Box to Field/ Pit LFf ft Opening Sealed: Y/ N/Partial V r End Cap v / Inlet/Outlet Pipes&Baffles Y—N Location/ Separations Foundation to tank ft. Foundation to absorption ft, Separation of Pits Conforms as per Plot Plan Y N A 0/`7— Engineer Report and As-Built , Y N Location of Sy n Property: Front ear Left Side Right Side Middle Fron Middle Rear m to Approved Partial Approved and needs to be re-inspected, please call the Building &Codes Office Disapproved Last revised 021006 Last revised 1/6/05 i 1 , I2 , /4,....1 , Li-, , 7 ,- ,,/I 7 /(......._ , / 01,''''-. 0 7----'---1/ 7F i C: fey` r , , l t 3ol , k \ V/\ I 1 ttv j9t . (74\ 1 VIX 1 A .n. .. ‘ 00 3% t,-,k0.4....,ac- ,,,, ,,f7.44, . 3of .: ..0 ....- 1 --- .3,C" Rou h Plumbing IInsulation Inspe ti gon Report 1-E Office No. (518) 761-8256 Date Inspectiop request received: Queensbury Building &Code Enforcement Arrive: )--1 - I.U am/p rt: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: . ult-4(' -i?"171 C NAME: I A A4LikA-ftqa PERMIT #: d tY LOCATION: , INSPECT ON: Ft, °k, TYPE OF STRUCTURE: Y N N/A Rough Plumbing /Nail Plates Plumbing Vent/Vents in Place 1 '/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain/Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping topsc,L,4 Air/Head for 15 minutes �lnsula /Res idential Check/Commercial Check ' C C` i L- k C) Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace pact work sealed'1 properly/No duct tape r j COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005,revised January 7,2008 -Now Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection re est received: Queensbury Building & Code Enforcement Arrive: epart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's I tials: NAME: Ce,v1C— PERMIT #: LOCATION: 36 144M' 47 INSPECT ON: 6g TYPE OF STRUCTURE: Y N N/A Rough Plumbing / Nail Plates Plumbing Vent/ Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/ change of direction Pressure Test Drain / Vent Air/ Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air / Head 50 P.S.I for 15 minutes Insulation I Residential Check/ Commercial Check re-- 6 Proper Vent, Attic Vent c?v 6'5 • Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace . Duct work sealed properly/ No duct tape COMMENTS: L:\Pam Whiting\Building&Codes\Inspection Forms\Rough Plumbing Insulation Report.revised Nov 17 2003.doc Revised February 15,2005 I— \$ Framing / Firestopping Inspection'Report Office No. (518) 761-8256 Date inspection request received: Queensbury Building&Code Enforcement Arrive: am/ part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's initials:., NAME: PERMIT#: ff02C LOCATION: /IU i re,/ c.Yf INSPECT ON: r, '" TYPE OF STRUCTURE: -- � Y N N/A Framing COMMENTS: « 22" x 30" minimum Jack Studs/Headers Bracing I Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 %(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour �, ratt ;3hour eh?,,V&"(6' LO112& qbcf‘z) Firestoppi5n 2 n p k netration sealed �1V� 16 inch insulation in cavity min. Garage Fire Separation S (/ f� i /os06-_, NHouse side%inch or 5/8 inch Type X t Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Fortes-OLO\Building&Codestlnspection Foims Framsng Firestopping inspection Report doc Revised January 7,2008 I_ 6 $ ` - Rough Plumbing if Insulation Inspection Report Office No. (518) 761-8256 Date In pecti9rt request received: \ ;72 Queensbury Building & Code Enforcement Arrive: 4 o am/pm Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: -.i? NAME: ,.itit-e PERMIT#: LOCATION: L /10,- a INSPECT ON: '2,—_ _ - > . TYPE OF STRUCTURE: Y N N/A I Rough Plumbin ail Plates t/Vents in Place 1 V2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction /1 r''Prefsure Test ,Bain/Vent Aiyy/Head 5'P.S.I. or 10 ft. above highest connection for 15 minutes P r ssure Test 0,er Supply Piping • Head '.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed (No Insulation) Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Repart.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 / ( E Framing I FirestoppingIns ion Repo ( Office No. (518)761-8256 Date Inspeptio�request received:41.61.(2g_ Queensbury Building &Code Enforcement Arrive: 4 _ am/ De rt: am/pm 742 Bay Road, Queensbury, NY 12804 Ins or's I dials: NAME: PERMIT#: (Y- LOCATIION: .1/ INSPECT ON: TYPE OF STRUCTURE: (44/0 Y N N/A COMMENTS: Framing Attic Access 22"x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate t' 1 %(w) 16 gauge (8) 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and*ate shield 24 inches from wall • n1, 2, 3hour Fire wail 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space I Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade L:\Building&Codes Forms-OLD\Building&Codeslinspec Lion FonnsTraming Firestopping inspection Report.doc Revised January 7,2008 , I, fit_A. i — 10 cAm Foundation Inspection Report po-L--- dk -.' ' Office No.(518)761-8256 Date Inspec 'tio equest received: Queensbury Building&Code Enforcement Arrive:(I`- am/pm� Depart: am/pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: ..,( L/ NAME: T)W PERMIT#: Cr v LOCATION: LJ INSPECT ON: jigIOr TYPE OF STRUCTURE: Comments f Y , N/A "X Footings / iers j i Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior I Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation inspection Report.doc Last printed 12/20/2005 9:24:00 AM , ` . t f _ , _ f j� h://.� t �� tea..--. d L7, Foundation Inspection Report Office No.(518)761-8256 Date Inspection reque . Queensbury Building&Code Enforcement Arrive: 1.Lo= i •m Depart: - ; I p 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initial- N /Th ' '& -.- AME: 6 i)/ , , P RMIT#: 0-c._ _ ' LOCATION: '7 le IL a r'' INSPECT ON: - TYPE OF STRUCTURE: Comments /i, N‘ 151SV`' \,,,, 1 Y N N/A Footings- — — Piers Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place 0 Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width hes above footing 6 niil ly for wet areas under slab Backfill proval N. Plv=bifig Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM 4/66,7 Founds ' iz)oi" tion Inspection Report � �� Office No.(518)761-8256 Date Inspectio request received: Queensbury Building&Code Enforcement Arrive: �'-[,i am/p,m�.,�,. Depart: pm 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials: u\ �� o of-05 NAME: �,;>PERMIT#: LOCATION: ` >% - INSPECT ON: / (2iJ c,:37c-/oP TYPE OF STRUCTURE: Comments FOr_ Y N N/A otin 'Piers Monolithic Slab -Reinforcement in Place !�/j- The contractor is responsible fo providing protection from freezing for 48 hours following the placement of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab PVC/Cast/Copper Foundation Insulation Interior/Exterior R- Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspection Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM O3o2 Permit Number REScheck Compliance Certificate Checked By/Date New York State Energy Conservation Construction Code REScheck Software Version 3.6 Release 2 Data filename: Z:\Clutel\Rescheck\38 Howard St.rck PROJECT TITLE: 26 x36(936) Ranch COUNTY: Warren STATE:New York HDD: 7635 CONSTRUCTION TYPE: Detached 1 or 2 Family HEATING TYPE: Non-Electric WINDOW /WALL RATIO: 0.09 DATE: 01/22/08 DATE OF PLANS: 1/22/2008 PROJECT DESCRIPTION: 38 Howard Street Queensbury,Ny 12804 DESIGNER/CONTRACTOR: Clute Enterprises, Inc. 6 Holden Ave Queensbury, NY 12804 COMPLIANCE: Passes Maximum UA= 217 Your Home UA= 178 18.0%Better Than Code(UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor Ceiling 1: Flat Ceiling or Scissor Truss 936 30.0 0.0 33 Wall 1: Wood Frame, 16" o.c. 992 19.0 0.0 53 Window 1: Vinyl Frame:Double Pane 67 0.490 33 Door 1: Solid 21 0.230 5 Door 2: Glass 21 0.490 10 Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 936 19.0 0.0 44 Furnace 1: Forced Hot Air, 92 AFUE COMPLIANCE STATEMENT: The proposed building represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed systems have been designed to meet the New York State Energy Conservation Construction Code requirements. When a Registered Design Professional has stamped and sign:, this 'age, they are attesting that to the best ofhis/her knowledge, belief and professional judgment, such p1. . or sp %"fications are in compli ce with this Code. Builder/Designer Date l RFScheck Inspection Checklist New York State Energy Conservation Construction Code REScheck Sofrware Version 3.6 Release 2 DATE: 01/22/08 PROJECT TITLE: 26 x36(936) Ranch Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Vinyl Frame:Double Pane, U-factor: 0.490 For windows without labeled U-fictors, describe features: #Panes Frame Type Thermal Break? [ ]Yes [ ]No Comments: Doors: [ ] 1. Door 1: Solid, U-factor: 0.230 Comments: [ ] 2. Door 2: Glass,U-factor: 0.490 Comments: Floors: [ ] 1. Floor 1: All-Wood Joist/Truss:Over Unconditioned Space, R-19.0 cavity insulation Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 92 AFUE or higher Make and Model Number Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1)Type IC rated, or 2)installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-11. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-6. [ ] Supply ducts in unconditioned spaces must be insulated to R-11. [ ] Return ducts in unconditioned spaces(except basements)must be insulated to R- [ ] Return ducts in unconditioned spaces (except basements)must be insulated to R-2.. Insulation is not required on return ducts in basements. Duct Construction: [ ] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics(adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means fir balancing air and water systems. Temperature Controls: [ ] Each dwelling unit has at lesat one thermostat capable of automatically adjusting the space temperature set point ofthe largest zone. Electric Systems: [ ] Separate electric meters are required for each dwelling unit. Fireplaces: [ ] Fireplaces must be installed with tight fitting non-combustible fireplace doors. [ ] Fireplaces must be provided with a source of combustion air, as required by the Fireplace construction provisions of the Building Code of New York State, the Residential Code of New York State or the New York City Building Code, as applicable. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% ofthe heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature(F) Up to 1" Up to 1.25" 1.5"to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range(Fl 2"Runouts 1" and Less 1.25" to 2" 2.5"to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate(fir£ed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD(Building Department Use Only)