ComCheck COMcheck Software Version 4.1.1.0 riAlLfii Interior Lighting Co 1. if.= eV ficate MAY 13 2019 Project Information ,!„. Energy Code: 2015 IECC TOWN OF QUEENSBURY Project Title: BUILDING&CODES Project Type: REVIt Nev::— Lion Construction site:ENERGY CODE OMPLIANCE 302.6-1-27 CC-0297-2019 Aldi Inc Additional Efficiency Package(s) -03 Glen St Unspecified FILE COPYcommerical Alterations 22,830 s.f. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) . 1-Sales(Retail) 21975 1.26 27688 Total Allowed Watts= 27689 Ir. Proposed Interior Lighting Power A B C D E Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Sales(Retail) LED 1:L1/L1E:8 Ft.LED Strip Light:LED Other Fixture Unit 90W: 1 17 88 1496 LED 2:L2/L2E:4 Ft.LED Strip Light:LED Other Fixture Unit 46W: 1 4 44 176 LED 3:L4/L4E:2x4 LED Recessed Troffer:LED Other Fixture Unit 46W: 1 16 44 704 LED 4:L10:4 Ft.LED Vaportite:LED Other Fixture Unit 60W: 1 7 63 441 LED 7:N1:3.7 Ft.LED Linear Strip Module:LED Other Fixture Unit 50W: 1 12 54 648 LED 8:N2/N2E:5.5 Ft.LED Linear Strip Module:LED Other Fixture Unit 80W: 1 95 72 6840 LED 9:N3:3.7 Ft.LED Linear Strip Module:LED Other Fixture Unit 36W: 1 12 34 408 LED 10:N3H:3.7 Ft.LED Linear Strip Module:LED Other Fixture Unit 50W: 1 7 54 378 LED 11:N4/N4E:5.5 Ft.LED Linear Strip Module:LED Other Fixture Unit 80W: 1 30 72 2160 LED 12:N5:3.7 Ft.LED Linear Strip Module:LED Other Fixture Unit 36W: 1 4 34 136 LED 13:N5X:5.5 Ft.LED Linear Strip Module:LED Other Fixture Unit 60W: 1 12 54 648 LED 15:N7/N7D: 1.1 Ft.LED Single Spot Module:LED Other Fixture Unit 28W: 1 23 28 644 LED 16:N8/N8D: 1.1 Ft.LED Double Spot Module:LED Other Fixture Unit 46W: 1 18 45 810 LED 14:N4UN4LE:5.5 Ft.LED Linear Strip Module:LED Other Fixture Unit 50W: 1 4 54 216 I; LED 15:L14/L14E:1x4 Ft.LED Recessed Troffer:LED Other Fixture Unit 46W: 1 21 44 924 Total Proposed Watts= 16629 I Interior Lighting PASSES: Design 40% better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Project Title: Report date: 04/23/19 Data filename: M:\2018 Jobs\481 -ALDI-SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 1 of 6 Queensbury NY.cck "'I II ai 1 6. Anthony DiMascio - MEP Engr. kI4 ^v 1 4/26/19 Name-Title Signature Date ---Of NE� •r1 n Ir- 11021 � f j� LCFj m dail! z y(ZO 09812° F Ark () ESS10aP Project Title: Report date: 04/23/19 Data filename: M:\2018 jobs\481 -ALDI - SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 2 of 6 Queensbury NY.cck irlA COMcheck Software Version 4.1.1.0 ii Mechanical Compliance Certificate Project Information Energy Code: 2015 IECC Project Title: Location: Glens Falls, New York Climate Zone: 6a Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: Additional Efficiency Package(s) Unspecified Mechanical Systems List Quantity System Type&Description 1 RTU-1 (Single Zone): Heating: 1 each-Central Furnace,Gas,Capacity=540 kBtu/h Proposed Efficiency=81.00%Et,Required Efficiency: 80.00%Et t Cooling: 1 each-Single Package DX Unit,Capacity=287 kBtu/h,Air-Cooled Condenser,Air Economizer f Proposed Efficiency=11.30 EER,Required Efficiency: 9.80 EER + 11.4 IEER Fan System: RTU-1 I SALES--Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Constant Volume,8095 CFM,8.0 motor nameplate hp,0.0 fan efficiency grade 1 RTU-2(Single Zone): Heating: 1 each-Central Furnace,Gas,Capacity=65 kBtu/h Proposed Efficiency=81.00%Et,Required Efficiency: 80.00%Et or 78%AFUE Cooling: 1 each-Single Package DX Unit,Capacity=24 kBtu/h,Air-Cooled Condenser,Air Economizer Proposed Efficiency=17.00 SEER,Required Efficiency: 14.00 SEER Fan System: RTU-2 I SUPPORT--Compliance(Motor nameplate HP method): Passes Fans: FAN 2 Supply,Constant Volume,600 CFM,0.5 motor nameplate hp,0.0 fan efficiency grade 1 FCU-1/HP-1 (Single Zone): Split System Heat Pump Heating Mode:Capacity= 12 kBtu/h, Proposed Efficiency= 10.50 HSPF,Required Efficiency=8.20 HSPF Cooling Mode:Capacity= 10 kBtu/h, i. Proposed Efficiency=20.20 SEER,Required Efficiency: 14.00 SEER .1 Fan System: FCU-1/HP-1 I OFFICE--Compliance(Motor nameplate HP method): Passes Fans: FAN 3 Supply,Constant Volume,300 CFM,0.1 motor nameplate hp,0.0 fan efficiency grade 2 UH-1-2(Single Zone): Heating: 1 each-Unit Heater,Gas,Capacity=75 kBtu/h Proposed Efficiency=80.00%Ec, Required Efficiency: 80.00%Ec Fan System: UH-1-2 I BACK ROOM--Compliance(Motor nameplate HP method): Passes Fans: FAN 4 Supply,Constant Volume,950 CFM,0.1 motor nameplate hp,0.0 fan efficiency grade 2 EWH-1: Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481 -ALDI - SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 1 of 14 Queensbury NY,cck mi Quantity, System Type&Description Electric Storage Water Heater,Capacity: 19 gallons Proposed Efficiency:0.00 SL,%/h(if>12 kW),Required Efficiency: 1.66 SL,%/h(if> 12 kW) Mechanical Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4.1.1.0 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. �� �^ . , Anthony DiMascio - MEP Engineer bki "U uV 04/25/19 Name-Title Signature — Date OF NE►N ;1 n n i� jq . w �c'(`O 098120 %Pess10NP Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481 -ALDI -SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 2 of 14 Queensbury NY.cck COMcheck Software Version 4.1.1.0 11 Inspection Checklist Energy Code: 2015 IECC Requirements: 0,0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # I Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans, specifications, and/or ❑Complies [PR2]1 calculations provide all information ❑Does Not ;with which compliance can be ;determined for the mechanical ❑Not Observable systems and equipment and ❑Not Applicable !document where exceptions to the 'standard are claimed. Load calculations per acceptable engineering standards and handbooks. C103.2 Plans, specifications, and/or ❑Complies I. [PR3]1 calculations provide all information ❑Does Not !with which compliance can be ;determined for the service water ❑Not Observable 'heating systems and equipment and ❑Not Applicable document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. C406 Plans, specifications, and/or ElComplies [PR9]1 calculations provide all information ❑Does Not with which compliance can be determined for the additional energy ❑Not Observable efficiency package options. Observable,__, Applicable Additional Comments/Assumptions: t 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481 -ALDI -SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 3 of 14 11 Queensbury NY.cck sectiog # Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID C403.2.4. Snow/ice melting system sensors for EComplies 5, future connection to controls. Freeze ❑Does Not C403.2.4. protection systems have automatic 6 controls installed. ❑Not Observable [F09)3 ❑Not Applicable Additional Comments/Assumptions: I NI 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481 -ALDI-SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 4 of 14 Queensbury NY.cck pi, i . Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID • C404.5, Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ❑Not Observable ❑Not Applicable C404.5, Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. (PL6]3 ❑Not Observable ❑Not Applicable C404.5, Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ❑Not Observable ❑Not Applicable C404.5, Heated water supply ping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not 1' C404.5.2 requirements. Refer to section details. i [PL6]3 ❑Not Observable ❑Not Applicable C404.5, Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. (PL6]3 ❑Not Observable ❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating ENot Observable cycle. ❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating ❑Not Observable cycle. ❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies "' [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating ❑Not Observable _ cycle. ❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to • <= 5 minutes after end of heating ['Not Observable cycle. DNot Applicable C404.6.3 Pumps that circulate water between a ❑Complies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating ['Not Observable cycle. ❑Not Applicable II Nj •' 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481-ALDI-SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 5 of 14 Queensbury NY.cck Section Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.7 Water distribution system that pumps ['Complies [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a [Not Observable demand recirculation water system. Observable,__, Applicable I Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. C404.7 Water distribution system that pumps ❑Complies [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a ❑Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F, C404.7 Water distribution system that pumps ❑Complies [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a ❑Not Observable ) demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. C404.7 Water distribution system that pumps ❑Complies [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a ❑Not Observable demand recirculation water system. LiNot Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. C404.7 Water distribution system that pumps ❑Complies [PL8]3 water from a heated-water supply ❑Does Not ri pipe back to the heated-water source " through a cold-water supply pipe is a ❑Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water • entering the cold-water piping to 104°F. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481-ALDI-SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 6 of 14 Queensbury NY.cck } fi 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481 -ALDI-SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 7 of 14 Queensbury NY.cck 0 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions t i & Req.ID C402.2.6 Thermally ineffective panel surfaces of❑Complies [ME41]3 sensible heating panels have ❑Does Not insulation >= R-3.5. ['Not Observable ❑Not Applicable C403.2.12 HVAC fan systems at design ❑Complies See the Mechanical Systems list for values. .1 conditions do not exceed allowable ❑Does Not [ME65]3 fan system motor nameplate hp or fan system bhp. ❑Not Observable ❑Not Applicable C403.2.12 Fans have efficiency grade(FEG) >= ❑Complies .3 67.The total efficiency of the fan at ❑Does Not [ME117]2 the design point of operation <= 15% of maximum total efficiency of the ❑Not Observable fan. ❑Not Applicable C403.2.13 Unenclosed spaces that are heated ❑Complies [ME71]2 use only radiant heat. ❑Does Not ['Not Observable ❑Not Applicable µ C403.2.3 HVAC equipment efficiency verified. ❑Complies See the Mechanical Systems list for values. Irl [ME55]2 ❑Does Not ['Not Observable ❑Not Applicable C403.2.4. Fault detection and diagnostics ❑Complies 7 installed with air-cooled unitary DX ❑Does Not [ME113]2 units having economizers. li ❑Not Observable ❑Not Applicable C403.2.6. Demand control ventilation provided ❑Complies 1 for spaces>500 ft2 and >25 ❑Does Not [ME59]1 people/1000 ft2 occupant density and served by systems with air side ❑Not Observable • economizer, auto modulating outside ❑Not Applicable air damper control,or design airflow >3,000 cfm. C403.2.6. Enclosed parking garage ventilation ❑Complies 2 has automatic contaminant detection ❑Does Not [ME115]3 and capacity to stage or modulate ❑Not Observable fans to 50%or less of design capacity. ❑Not Applicable C403.2.7 Exhaust air energy recovery on ❑Complies f [ME57]1 systems meeting Table C403.2.7(1) ❑Does Not and C403.2.7(2). ❑Not Observable ❑Not Applicable C403.2.8 Kitchen exhaust systems comply with ❑Complies [ME116]3 replacement air and conditioned EDoes Not supply air limitations, and satisfy hood rating requirements and maximum ❑Not Observable J. exhaust rate criteria. ❑Not Applicable C403.2.9 HVAC ducts and plenums insulated. ❑Complies [ME60]2 Where ducts or plenums are installed ❑Does Not in or under a slab,verification may need to occur during Foundation ❑Not Observable Inspection. ❑Not Applicable C403.2.9 Ducts and plenums sealed based on ❑Complies [ME10]2 static pressure and location. ❑Does Not ❑Not Observable ❑Not Applicable "I 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481-ALDI -SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 8 of 14 Queensbury NY.cck Section '# Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID . C403.2.9. Ductwork operating >3 in. water ❑Complies 1.3 column requires air leakage testing. ❑Does Not [ME11]3 ❑Not Observable ❑Not Applicable C403.2.9. Ductwork operating >3 in. water ❑Complies ''_ I1.3 column requires air leakage testing. ❑Does Not 1 [ME11]3 ❑Not Observable ❑Not Applicable C403.2.9. Ductwork operating >3 in.water ❑Complies 1.3 column requires air leakage testing. ❑Does Not it' [ME11]3 [Not Observable V. ❑Not Applicable C403.2.9. Ductwork operating >3 in.water ❑Complies 1.3 column requires air leakage testing. ❑Does Not [ME11]3 ['Not Observable ❑Not Applicable C403.3 Air economizers provided where ❑Complies [ME62]' required, meet the requirements for ❑Does Not design capacity, control signal, ['Not Observable ventilation controls, high-limit shut-off, integrated economizer control,and ❑Not Applicable provide a means to relieve excess outside air during operation. C403.4.2. Open-or closed circuit cooling towers ❑Complies • 3.2.2 have a separate heat exchanger to Oboes Not 1 [ME122]3 isolate the cooling tower from the heat pump loop, and heat loss is ❑Not Observable it controlled by shutting down the ❑Not Applicable I " circulation pump on the cooling tower loop. C403.4.4. Multiple zone VAV systems with DDC ❑Complies See the Mechanical Systems list for values. t 6 of individual zone boxes have static Oboes Not [ME110]3 pressure setpoint reset controls. ❑Not Observable �" ❑Not Applicable C403.4.4. Multiple zone VAV systems with DDC ❑Complies See the Mechanical Systems list for values. 6 of individual zone boxes have static ElDoes Not [ME110]3 pressure setpoint reset controls. ❑Not Observable ❑Not Applicable C403.4.4. Multiple zone VAV systems with DDC ❑Complies See the Mechanical Systems list for values. 6 of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. [Not Observable ENot Applicable C403.4.4. Multiple zone VAV systems with DDC ❑Complies See the Mechanical Systems list for values. 6 of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. ['Not Observable ❑Not Applicable ; , C408.2.2. Air outlets and zone terminal devices ❑Complies • 1 have means for air balancing. ❑Does Not [ME53)3 ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) "3 Low Impact(Tier 3) Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481-ALDI-SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 9 of 14 Queensbury NY.cck Section Mechanical Rough-In Inspection Complies? • Comments/Assumptions & Req.ID C403.5, Refrigerated display cases,walk-in ❑Complies C403.5.1, coolers or walk-in freezers served by ❑Does Not C403.5.2 remote compressors and remote [ME123]3 condensers not located in a ❑Not Observable condensing unit, have fan-powered ❑Not Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: I 1 High Impact(Tier 1) [ Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481-ALDI-SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 10 of 14 Queensbury NY.cck , Section Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished O&M manuals for HVAC ❑Complies C408.2.5. systems within 90 days of system ❑Does Not 3 acceptance. [F18]3 ❑Not Observable (: ! ❑Not Applicable C403.2.2 HVAC systems and equipment ❑Complies [F127]3 capacity does not exceed calculated ❑Does Not loads. ENot Observable ❑Not Applicable C403.2.4. Heating and cooling to each zone is ❑Complies 1 controlled by a thermostat control. ❑Does Not [FI47]3 Minimum one humidity control device per installed ['Not Observable humidification/dehumidification ❑Not Applicable system. C403.2.4. Heating and cooling to each zone is ❑Complies 1 controlled by a thermostat control. ❑Does Not [F147]3 Minimum one humidity control device per installed ENot Observable humidification/dehumidification ❑Not Applicable system. C403.2.4. Heating and cooling to each zone is ❑Complies 1 controlled by a thermostat control. ❑Does Not [F147]3 Minimum one humidity control device per installed ❑Not Observable humidification/dehumidification ❑Not Applicable system. C403.2.4. Heating and cooling to each zone is ❑Complies • 1 controlled by a thermostat control. ❑Does Not [FI47]3 Minimum one humidity control device per installed ENot Observable humidification/dehumidification ENot Applicable system. C403.2.4. Heat pump controls prevent ❑Complies 1.1 supplemental electric resistance heat ❑Does Not [F142]3 from coming on when not needed. ❑Not Observable ❑Not Applicable C403.2.4. Thermostatic controls have a 5 °F ❑Complies 1.2 deadband. ❑Does Not [F138]3 ❑Not Observable ❑Not Applicable C403.2.4. Temperature controls have setpoint ❑Complies 1.3 overlap restrictions. ❑Does Not (F120]3 ENot Observable ; ENot Applicable C403.2.4. Each zone equipped with setback ❑Complies 2 controls using automatic time clock or ❑Does Not [F139]3 programmable control system. ENot Observable ENot Applicable • C403.2.4. Automatic Controls: Setback to 55°F ❑Complies 2.1, (heat)and 85°F (cool); 7-day clock, 2- ❑Does Not C403.2.4. hour occupant override, 10-hour 2.2 backup [Not Observable [F140]3 ENot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481-ALDI-SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 11 of 14 Queensbury NY.cck j1 Section * Final Inspection Complies? Comments/Assumptions & Req.ID C403.2.4. Systems include optimum start ❑Complies 2.3 controls. ❑Does Not [FI41]3 ❑Not Observable ❑Not Applicable C403.2.4. Systems include optimum start ❑Complies 2.3 controls. ❑Does Not [F141]3 ❑Not Observable ❑Not Applicable C403.2.4. Systems include optimum start ❑Complies 2.3 controls. ❑Does Not [F141]3 ❑Not Observable ", ❑Not Applicable C403.2.4. Systems include optimum start ❑Complies i ' 2.3 controls. ❑Does Not irn` [FI41]3 ❑Not Observable ❑Not Applicable C404.3 Heat traps installed on supply and ❑Complies [FI11]3 discharge piping of non-circulating ❑Does Not systems. ❑Not Observable ❑Not Applicable C404.4 All piping insulated in accordance with ❑Complies [F125]2 section details and Table C403.2.10. ❑Does Not ❑Not Observable ❑Not Applicable C408.2.1 Commissioning plan developed by ❑Complies [F128]1 registered design professional or ❑Does Not approved agency. ['Not Observable ; ❑Not Applicable II 1 C408.2.3. HVAC equipment has been tested to ❑Complies 1 ensure proper operation. ❑Does Not [FI31]1 ❑Not Observable ❑Not Applicable C408.2.3. HVAC control systems have been ❑Complies k 2 tested to ensure proper operation, ❑Does Not [F110]1 calibration and adjustment of controls. ❑Not Observable ❑Not Applicable C408.2.3. Economizers have been tested to ❑Complies 3 ensure proper operation. ❑Does Not [FI32]1 ❑Not Observable ❑Not Applicable C408.2.4 Preliminary commissioning report ❑Complies [F129]1 completed and certified by registered ❑Does Not design professional or approved agency. ❑Not Observable ❑Not Applicable 1'1 C408.2.5. Furnished HVAC as-built drawings ❑Complies 1 submitted within 90 days of system ❑Does Not h, [FI7]3 acceptance. ❑Not Observable ❑Not Applicable C408.2.5. An air and/or hydronic system ❑Complies 3 balancing report is provided for HVAC ❑Does Not ir [F143]1 systems. ['Not Observable 4" ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481-ALDI-SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 12 of 14 Queensbury NY.cck Section # Final Inspection Complies? Comments/Assumptions & Req.ID C408.2.5. Final commissioning report due to EComplies 4 4 building owner within 90 days of ❑Does Not [F130]1 receipt of certificate of occupancy. �1, ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: M, I 41 41 I if 1 ',I 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481-ALDI-SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 13 of 14 Queensbury NY.cck 7�NyI rl Project Title: Report date: 04/25/19 Data filename: M:\2018 Jobs\481 -ALDI - SWN XX-Queensbury NY\Buildings\Design Documents\Reports\ALDI Page 14 of 14 Queensbury NY.cck