ResCheck REScheck Software Version 4..6.5 0 i Compliance Certificate Nui N 1. 4 to O N 0 Project Taylor o c Energy Code: 2015 IECC D 2 tC 2 fi �\/7 fE cn 0 Tr N Location: Glens Falls, New York lVi 15 lJ V L� _ N Construction Type: Single-family 0 . E Project Type: New Construction , = a Conditioned Floor Area: 2,224 ft2 _ JUN 2 4 2019 c Li Glazing Area 12% ^ N E In Climate zone: 6 (7635 HDD) TOWN OF OUEENSBURY e. 3 E 0 Permit Date: BUILDING&CODES ti e 2 Permit Number: 0 O tF 0 Construction Site: Owner/Agent: Designer/Contractor: CO = N. 74 Richmond Hill Drive Hodorowski Homes Northstar Home Design, LLC Queensbury, NY Compliance: Passes using UA trade-off Compliance: 0.6%Better Than Code Maximum UA: 325 Your UA: 323 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Perimeter R-Value R-Value Ceiling 1: Raised or Energy Truss 1,382 49.0 0.0 0.020 28 Wall 1:Wood Frame, 16"o.c. 2,713 21.0 0.0 0.057 134 Window 1:Vinyl/Fiberglass Frame:Double Pane with Low-E 278 0.300 83 Door 1:Solid 44 0.190 8 Door 2:Glass 40 0.300 12 Basement Wall 1: Solid Concrete or Masonry 1,256 21.0 0.0 0.043 54 Wall height:8.0' Depth below grade: 7.0' Insulation depth: 8.0' Floor 1:All-Wood Joist/Truss:Over Unconditioned Space 84 30.0 0.0 0.033 3 Floor 2:All-Wood Joist/Truss:Over Outside Air 26 30.0 0.0 0.033 1 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the • check Inspection Checklist. Name-Title Signature ` s di Date 's 44%, ' , •,,., Project Title: Taylor "1 Report date: 06/05/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\74 Rich - - 'uF' ...rck Page 1 of 9 0 REScheck Software VersionChecklist 4.6.5 Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ❑Complies 103.2 documentation demonstrate DDoes Not [PR1]1 energy code compliance for the V building envelope.Thermal ['Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. ❑Not Observable 31, Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods ❑Not Observable Btu/hr Btu/hr ❑Not Applicable approved by the code official. pP Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Taylor Report date: 06/05/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\74 Richmond Hill Drive.rck Page 2 of 9 • Section Plans Verified Field Verified Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R_ R- ❑Does Not table for values. insulation is used,verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall ❑Complies [F05]1 insulation installed per ❑Does Not manufacturer's instructions. 42.1' ❑Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F06]1 insulation depth of burial or ❑Does Not table for values. distance from top of wall. [Not Observable ❑Not Applicable 303.2.1 A protective covering is installed Complies [FO11]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. DNot Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F012)2 controls installed. ODoes Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Taylor Report date: 06/05/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\74 Richmond Hill Drive.rck Page 3 of 9 • Section Plans Verified Field Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 ❑Does Not table for values. [FR1]1 ❑Not Observable I4. ONot Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.5 ONot Observable [FR2]1 ONot Applicable 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not ¢4 with the NFRC test procedure or taken from the default table. ❑Not Observable ONot Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ❑Does Not 4f, instructions. ['Not Observable ONot Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR2O]1 is listed and labeled as meeting ElDoes Not AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC ONot Observable 400 that do not exceed code ONot Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate<_2.0 cfm leakage at 75 Pa. ONot Observable ONot Applicable 403.3.1 Supply and return ducts in attics ❑Complies [FR12]1 insulated >=R-8 where duct is ❑Does Not 41, >=3 inches in diameter and >= R-6 where<3 inches.Supply and ['Not Observable return ducts in other portions of ONot Applicable the building insulated>= R-6 for diameter>= 3 inches and R-4.2 for<3 inches in diameter. 403.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not 1 ❑Not Observable ONot Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105 QF or chilled fluids ❑Does Not below 55 QF are insulated to>_R- N 3 ['Not Observable ONot Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not ❑Not Observable ONot Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ONot Observable ONot Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ONot Observable DNot Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Taylor Report date: 06/05/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\74 Richmond Hill Drive.rck Page 4 of 9 Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:Taylor Report date: 06/05/19 Data filename: C:\Usersjkazl\OneDrive\Documents\REScheck\74 Richmond Hill Drive.rck Page 5 of 9 • Section Plans Verified Field Verified Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. ❑Not Observable ❑Not Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 ❑ Steel ❑ Steel ['Not Observable ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the 44) underside of the subfloor,or floor ['Not Observable framing cavity insulation is in ❑Not Applicable contact with the top side of sheathing,or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ['Not Observable [IN3]1 exterior,the exterior insulation 4t, requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]1 manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:Taylor Report date: 06/05/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\74 Richmond Hill Drive.rck Page 6 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Re..ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, 402.2.E ❑ Steel ❑ Steel ❑Not Observable [Al]' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]' Blown insulation marked every 300 ft2. ['Not Observable ❑Not Applicable 402.2.3 Vented attics with air permeable ❑Complies [FI22]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. ❑Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [FI3]' insulation .R.-value of the ❑Does Not adjacent assembly. ❑Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50 = ❑Complies [FI17]' ach in Climate Zones 1-2,and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.3.4 Duct tightness test result of<=4 cfm1100 cfm/100 ❑Complies [F14)' cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27)' determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a DNot Observable pressure differential of 0.1 inch ❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test.Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g.across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI24]' by manufacturer at<=2%of ❑Does Not design air flow. ❑Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies (FI9)2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to :Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed ❑Complies [FI10)2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [FI11]2 systems have automatic or ODoes Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Taylor Report date: 06/05/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\74 Richmond Hill Drive.rck Page 7 of 9 • Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 403.6.1 All mechanical ventilation system ❑Complies [F125]2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ['Not Observable ElNot Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water Not Observable temperature based on outdoor ❑Not Applicable temperature. 403.5.1.1 Heated water circulation systems ❑Complies [F128]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply Not Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present.Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy.Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ❑Complies IF129]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically adjust the energy input to the ['Not Observable heat tracing to maintain the ONot Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1049F. 403.5.4 Drain water heat recovery units ❑Complies [FI31]2 tested in accordance with CSA ❑Does Not B55.1.Potable water-side pressure loss of drain water heat ❑Not Observable recovery units < 3 psi for ❑Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units<2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies [FI6]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. ❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Taylor Report date: 06/05/19 Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\74 Richmond Hill Drive.rck Page 8 of 9 • Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 401.3 Compliance certificate posted. ❑Complies [F17)2 Does Not ❑Not Observable ❑Not Applicable 303.3 Manufacturer manuals for ❑Complies [F118)3 mechanical and water heating ❑Does Not systems have been provided. ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title:Taylor Report date: 06/05/19 Data filename: C:\Usersjkazl\OneDrive\Documents\REScheck\74 Richmond Hill Drive.rck Page 9 of 9 iC 20 IECC Energy Efficiency15 Certificate Insulation Rating R-Value Above-Grade Wall 21.00 Below-Grade Wall 21.00 Floor 30.00 Ceiling / Roof 49.00 Ductwork (unconditioned spaces): Glass& Door Rating U-Factor SHGC Window 0.30 Door 0.19 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments