ComCheck.pdf COMcheck Software Version 4.1.1.0 il Inspection Checklist Energy Code: 2015 IECC IrriII Requirements: 11.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans and/or specifications provide all ❑Complies [PR1]' information with which compliance ❑Does Not can be determined for the building envelope and document where [:]Not Observable exceptions to the standard are ONot Applicable claimed. C103.2 Plans,specifications, and/or ❑Complies [PR2]1 calculations provide all information ❑Does Not with which compliance can be • determined for the mechanical ❑Not Observable systems and equipment and ONot Applicable • document where exceptions to the standard are claimed.Load calculations per acceptable engineering standards and handbooks. C103.2 Plans,specifications, and/or ❑Complies [PR3]' calculations provide all information ❑Does Not with which compliance can be determined for the service water ONot Observable heating systems and equipment and ONot Applicable document where exceptions to the standard are claimed. Hot water system sized per manufacturer's sizing guide. C103.2 Plans,specifications, and/or '❑Complies [PR4]' calculations provide all information ❑Does Not with which compliance can be determined for the interior lighting :Not Observable and electrical systems and equipment ONot Applicable and document where exceptions to the standard are claimed, Information provided should include interior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. C402.4.1 The vertical fenestration area <= 30 ❑Complies [PR10)1 percent of the gross above-grade wall ❑Does Not area. .ONot Observable ONot Applicable C402.4.1 The skylight area <= 3 percent of the ❑Complies [PR11]' gross roof area. ElDoes Not [Not Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\ALB-2018172.00 Saratoga Outpatient Page 5 of 17 Pulmonary\Calculations\Queensbury MO.cck • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\ALB-2018172.00 Saratoga Outpatient Page 6 of 17 Pulmonary\Calculations\Queensbury MO.cck Section # Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID C303.2 'Below-grade wall insulation installed ❑Complies [F0212 per manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable C303.2.1 'Exterior insulation protected against :❑Complies [F0611 damage,sunlight, moisture, wind, :DDoes Not landscaping and equipment maintenance activities. .❑Not Observable ❑Not Applicable C402.1.4 Below-grade wall insulation R-value. ❑Complies See the Envelope Assemblies table for values. [F01)2 ❑Does Not ❑Not Observable ❑Not Applicable C403.2.4, :Snow/ice melting system sensors for ElComplies 5, 'future connection to controls. Freeze ElDoes Not C403.2.4. protection systems have automatic ❑Not Observable 6 controls installed. [F09)3 ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\ALB-2018172.00 Saratoga Outpatient Page 7 of 17 Pulmonary\Calculations\Queensbury MO.cck • Section Framing/Rough-In Inspection Complies? Comments/Assumptions &Req.ID C402.5.1 ;The building envelope contains a ❑Complies [FR1611 continuous air barrier that is sealed in ❑Does Not an approved manner and either constructed or tested in an approved ❑Not Observable manner.Air barrier penetrations are ❑Not Applicable sealed in an approved manner. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\ALB-2018172.00 Saratoga Outpatient Page 8 of 17 Pulmonary\Calculations\Queensbury MO.cck Section Plumbing Rough-In Inspection Complies? Comments/Assumptions &Req.ID C404.5, Heated water supply piping conforms ❑Complies Requirement will be met. C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL613 ❑Not Observable ❑Not Applicable C404.5, :Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 DNot Observable ❑Not Applicable C404.6.1, Automatic time switches installed to ❑Complies C404.6.2 automatically switch off the '❑Does Not [PL3]1 recirculating hot-water system or heat trace. ❑Not Observable ,❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies Exception: Requirement does not apply, (PL713 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating ❑Not Observable cycle. ❑Not Applicable C404.6.3 Pumps that circulate water between a ❑Complies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <=5 minutes after end of heating :Not Observable cycle. ❑Not Applicable C404.7 Water distribution system that pumps ❑Complies Exception: Requirement does not apply. [PL8]3 water from a heated-water supply ❑Does Not pipe back to the heated-water source through a cold-water supply pipe is a [Not Observable demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. C404.7 Water distribution system that pumps ❑Complies [PL8I3 water from a heated-water supply ❑Does Not pipe back to the heated-water source ❑Not Observable through a cold-water supply pipe is a demand recirculation water system. ❑Not Applicable Pumps within this system have controls that start the pump upon receiving a signal from the action of a user of a fixture or appliance and limits the temperature of the water entering the cold-water piping to 104°F. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\ALB-2018172.00 Saratoga Outpatient Page 9 of 17 Pulmonary\Calculations\Queensbury MO.cck Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C402.2.6 Thermally ineffective panel surfaces of DComplies [ME4113 sensible heating panels have DDoes Not insulation >=R-3.5. :Not Observable ❑Not Applicable C402.5.5, Stair and elevator shaft vents have DComplies C403.2.4. motorized dampers that automatically DDoes Not [ME3]3 close. ENot Observable' ❑Not Applicable C402.5.5, Outdoor air and exhaust systems have;DComplies C403.2.4. motorized dampers that automatically :❑Does Not 3 shut when not in use and meet [ME5813 maximum leakage rates.Check ❑Not Observable gravity dampers where allowed. '❑Not Applicable C403.2.13 Unenclosed spaces that are heated DComplies • [ME7112 use only radiant heat. DDoes Not :Not Observable ❑Not Applicable C403.2.3 HVAC equipment efficiency verified. DComplies See the Mechanical Systems list for values. [ME55]2 DDoes Not 1 ❑Not Observable ❑Not Applicable C403.2.6, Demand control ventilation provided :❑Complies 1 for spaces >500 ft2 and >25 ❑Does Not [ME59]1 people/1000 ft2 occupant density and served by systems with air side ❑Not Observable economizer,auto modulating outside ❑Not Applicable air damper control, or design airflow >3,000 cfm. C403.2.6. Enclosed parking garage ventilation DComplies 2 has automatic contaminant detection DDoes Not [ME115]3 and capacity to stage or modulate fans to 50%or less of design capacity. ❑Not Observable ❑Not Applicable C403.2.7 Exhaust air energy recovery on DComplies [ME57]1 systems meeting Table C403.2.7(1) ❑Does Not and C403.2.7(2). [Not Observable ❑Not Applicable C403.2.8 ;Kitchen exhaust systems comply with ❑Complies [ME116]3 :replacement air and conditioned DDoes Not supply air limitations,and satisfy hood rating requirements and maximum ❑Not Observable exhaust rate criteria. ❑Not Applicable C403.2,9 HVAC ducts and plenums insulated. DComplies [ME60)2 Where ducts or plenums are installed DDoes Not in or under a slab,verification may need to occur during Foundation Not Observable Inspection. ❑Not Applicable C403.2.9 Ducts and plenums sealed based on DComplies [ME10]2 static pressure and location. DDoes Not ❑Not Observable ❑Not Applicable C403.2.9. Ductwork operating>3 in,water DComplies Exception: Requirement does not apply. 1.3 column requires air leakage testing, ❑Does Not [ME11]3 :Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\AL8-2018172.00 Saratoga Outpatient Page 10 of 17 Pulmonary\Calculations\Queensbury MO.cck • Section Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.4.4. Multiple zone VAV systems with DDC DComplies Exception:Requirement does not apply. 6 of individual zone boxes have static ❑Does Not [ME110]3 pressure setpoint reset controls. ❑Not Observable See the Mechanical Systems list for values. ❑Not Applicable C408.2.2. Air outlets and zone terminal devices ❑Complies 1 have means for air balancing. :❑Does Not [ME53J3 :❑Not Observable ❑Not Applicable C403.5, ;Refrigerated display cases,walk-in ❑Complies C403.5.1, coolers or walk-in freezers served by Does Not C403.5.2 remote compressors and remote [ME12313 condensers not located in a ❑Not Observable condensing unit, have fan-powered ❑Not Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5,2.. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\ALB-2018172.00 Saratoga Outpatient Page 11 of 17 Pulmonary\Calculations\Queensbury MO.cck Section Rough-In Electrical Inspection Complies? Comments/Assumptions & Req.ID C405.2,1 Lighting controls installed to uniformly'❑Complies [EL15I' reduce the lighting load by at least IDDoes Not 50%. '❑Not Observable ❑Not Applicable C405.2.1 Occupancy sensors installed in ❑Complies [EL18]' required spaces. IDDoes Not :❑Not Observable ENot Applicable C405.2.1, Independent lighting controls installed ❑Complies C405.2.2. per approved lighting plans and all ❑Does Not 3 manual controls readily accessible and ❑Not Observable • [EL23] visible to occupants. ENot Applicable C405.2.2. ;Automatic controls to shut off all ❑Complies 1 building lighting installed in all ❑Does Not [EL22]2 I buildings. ❑Not Observable: ;❑Not Applicable C405.2.3 ;Daylight zones provided with '❑Complies [EL16]2 individual controls that control the EDoes Not lights independent of general area ;lighting. ENot Observable ❑Not Applicable C405.2.3, Primary sidelighted areas are ❑Complies C405.2.3. equipped with required lighting EDoes Not 1, controls. C405.2.3. ENot Observable 2 ❑Not Applicable [EL2OP C405.2.3, Enclosed spaces with daylight area ;❑Complies C405.2.3. under skylights and rooftop monitors EDoes Not 1, are equipped with required lighting Observable 3405.2.3. controls. ;❑Not Applicable [EL21I' C405.2.4 Separate lighting control devices for ❑Complies [EL4I' specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable ENot Applicable C405.2.4 Additional interior lighting power ❑Complies [EL8I' allowed for special functions per the ❑Does Not approved lighting plans and is automatically controlled and Not Observable separated from general lighting. ENot Applicable C405.3 Exit signs do not exceed 5 watts per ;❑Complies [EL6]' face. IEDoes Not ❑Not Observable ,ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\ALB-2018172.00 Saratoga Outpatient Page 12 of 17 Pulmonary\Calculations\Queensbury MO.cck Section Insulation Inspection Complies? Comments/Assumptions & Req.ID C303.1 :Building envelope insulation is labeled Complies [IN1012 with R-value or insulation certificate ElDoes Not providing R-value and other relevant data. [Not Observable ONot Applicable C303.2.1 Exterior insulation is protected from :❑Complies (IN1412 damage with a protective material. ❑Does Not Verification for exposed foundation insulation may need to occur during [Not Observable Foundation Inspection. ❑Not Applicable C402.2.6 Radiant panels and associated ;❑Complies • [IN1813 components, designed for heat ❑Does Not transfer from the panel surfaces to the occupants or indoor space are ❑Not Observable insulated with a minimum of R-3.5. ❑Not Applicable C402.5.1, All sources of air leakage in the ❑Complies 1 building thermal envelope are sealed, ❑Does Not [IN1]' caulked,gasketed,weather stripped or wrapped with moisture vapor- :Not Observable permeable wrapping material to ;❑Not Applicable minimize air leakage. Additional Comments/Assumptions: • 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\ALB-2018172.00 Saratoga Outpatient Page 13 of 17 Pulmonary\Calculations\Queensbury MO.cck Section # Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished O&M instructions for ❑Complies C408.2.5. systems and equipment to the ❑Does Not 2 building owner or designated [FI17]3 representative. :Not Observable ❑Not Applicable C303.3, Furnished O&M manuals for HVAC ❑Complies C408.2.5. systems within 90 days of system '❑Does Not 3 acceptance. [FI8]3 DNot Observable ❑Not Applicable C402.5.3 Where open combustion air ducts ❑Complies [FI51]3 provide combustion air to open ❑Does Not combustion fuel burning appliances, the appliances and combustion air ❑Not Observable opening are located outside the DNot Applicable building thermal envelope or enclosed in a room,isolated from inside the thermal envelope. Such rooms are sealed and insulated. C402.5.8 Recessed luminaires in thermal ;❑Complies [FI2613 envelope to limit infiltration and be IC ❑Does Not rated and labeled.Seal between interior finish and luminaire housing. DNot Observable ❑Not Applicable C403.2.2 HVAC systems and equipment ;❑Complies [FI27]3 capacity does not exceed calculated :❑Does Not • loads. DNot Observable ❑Not Applicable C403.2.4. Heating and cooling to each zone is ❑Complies :Requirement will be met, 1 controlled by a thermostat control. ❑Does Not [FI47]3 Minimum one humidity control device DNot Observable Location on plans/spec: H0.1 :per installed 'humidification/dehumidification DNot Applicable system. C403.2.4. 'Thermostatic controls have a 5 °F ❑Complies 1.2 deadband. ❑Does Not [FI38]3 ❑Not Observable DNot Applicable C403.2.4. Temperature controls have setpoint '❑Complies 1.3 overlap restrictions. ❑Does Not [FI20]3 DNot Observable DNot Applicable C403.2.4. .Each zone equipped with setback ❑Complies 2 controls using automatic time clock or ❑Does Not [FI3913 programmable control system. :Not Observable DNot Applicable C403.2.4. 'Automatic Controls: Setback to 55°F '❑Complies 2.1, (heat)and 85°F(cool); 7-day clock, 2- ❑Does Not C403.2.4. :hour occupant override, 10-hour 2.2 backup ONot Observable [FI40]3 :Not Applicable C403.2.4. 'Systems include optimum start ❑Complies :Requirement will be met. 2.3 controls. ❑Does Not [FI41]3 Location on plans/spec: H0.1 DNot Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\ALB-2018172.00 Saratoga Outpatient Page 14 of 17 Pulmonary\Calculations\Queensbury MO.cck Section # Final inspection Complies? Comments/Assumptions &Req.ID C404.3 :Heat traps installed on supply and ❑Complies [FI11]3 ;discharge piping of non-circulating ❑Does Not •systems. DNot Observable ❑Not Applicable C404.4 All piping insulated in accordance with ❑Complies [F12512 section details and Table C403.2.10. EDoes Not ❑Not Observable ❑Not Applicable C404.6.1 Controls are installed that limit the ❑Complies [FI1213 operation of a recirculation pump EDoes Not • installed to maintain temperature of a storage tank.System return pipe is a ENot Observable dedicated return pipe or a cold water ❑Not Applicable supply pipe. C405.4.1 Interior installed lamp and fixture :❑Complies .See the Interior Lighting fixture schedule for values. [FI1811 lighting power is consistent with what EDoes Not is shown on the approved lighting plans,demonstrating proposed watts Not Observable are less than or equal to allowed ❑Not Applicable watts. C408.2.1 Commissioning plan developed by ❑Complies [FI28]1 registered design professional or ❑Does Not ;approved agency. ❑Not Observable ❑Not Applicable C408.2.3. HVAC equipment has been tested to ❑Complies 1 ensure proper operation. ❑Does Not [FI31]1 ['Not Observable ❑Not Applicable C408.2.3. HVAC control systems have been ❑Complies 2 tested to ensure proper operation, ❑Does Not [F11011 :calibration and adjustment of controls. ['Not Observable ;❑Not Applicable C408.2.4 Preliminary commissioning report ❑Complies [F12911 completed and certified by registered ;EDoes Not design professional or approved agency. ❑Not Observable ❑Not Applicable C408.2.5. Furnished HVAC as-built drawings ❑Complies 1 submitted within 90 days of system ❑Does Not (F17)3 acceptance. ❑Not Observable ❑Not Applicable C408.2.5. Furnished as-built drawings for ❑Complies 1 electric power systems within 90 days ❑Does Not [FI1613 of system acceptance. ❑Not Observable ❑Not Applicable C408.2.5. An air and/or hydronic system ❑Complies 3 balancing report is provided for HVAC EDoes Not [F143]1 systems. ❑Not Observable ❑Not Applicable C408,2.5. 'Final commissioning report due to ❑Complies 4 building owner within 90 days of Does Not [FI30]1 receipt of certificate of occupancy. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\ALB-2018172.00 Saratoga Outpatient Page 15 of 17 Pulmonary\Calculations\Queensbury MO.cck Section Final Inspection Complies? Comments/Assumptions &Req.ID C408.3 Lighting systems have been tested to ElComplies [F133)1 ensure proper calibration,adjustment, 'ODoes Not programming, and operation. ONot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\ALB-2018172.00 Saratoga Outpatient Page 16 of 17 Pulmonary\Calculations\Queensbury MO.cck Project Title: Queensbury Medical Offices Report date: 07/02/19 Data filename: P:\Projects\420-Architectural Collaborative\ALB-201B172.00 Saratoga Outpatient Page 17 of 17 Pulmonary\Calculations\Queensbury MO.cck