REScheck Software VersionChecklist 4.6.5
Energy Code: 2015 IECC
Requirements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed.Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
&Req.ID
103.1, Construction drawings and ❑Complies
103.2 documentation demonstrate ElDoes Not
[PR1]' energy code compliance for the
V, building envelope.Thermal ❑Not Observable
envelope represented on ❑Not Applicable
construction documents.
103.1, Construction drawings and ❑Complies
103.2, documentation demonstrate ❑Does Not
403.7 energy code compliance for
[PR3]' lighting and mechanical systems. ['Not Observable
y, Systems serving multiple ❑Not Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not
[PR2]2 on loads calculated per ACCA Coolin Coolin
Manual J or other methods g' g ❑Not Observable
ki
Btu/hr Btu/hr
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Stockton Report date: 07/16/19
Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\79 Richmond Hills Drive.rck Page 2 of 9
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1 Conditioned basement wall R- R- ❑Complies See the Envelope Assemblies
[F04]' insulation R-value.Where interior R_ R- ❑Does No
table for values.
insulation is used,verification t
.1.?; ['Not Observable
may need to occur during
Insulation Inspection.Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 Conditioned basement wall ❑Complies
[F05]' insulation installed per ❑Does Not
�i manufacturers instructions.
❑Not Observable
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies
[F06]' insulation depth of burial or ❑Does Not table for values.
�t distance from top of wall.
❑Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies
[F011]2 to protect exposed exterior ❑Does Not
+� insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
❑Not Applicable
403.9 Snow-and ice-melting system ❑Complies
[F012]2 controls installed. ❑Does Not
At, ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Stockton Report date: 07/16/19
Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\79 Richmond Hills Drive.rck Page 3 of 9
Section Plans Verified Field Verified
# Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ONot Observable
N,
ONot Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.5 ONot Observable
[FR2]1 ONot Applicable
303.1.3 U-factors of fenestration products ❑Complies
[FR4]1 are determined in accordance DDoes Not
It* with the NFRC test procedure or
taken from the default table. ❑Not Observable
ONot Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies
[FR23]1 installed per manufacturer's DDoes Not
instructions.
['Not Observable
ONot Applicable
402.4.3 Fenestration that is not site built ❑Complies
[FR20]1 is listed and labeled as meeting DDoes Not
4}, AAMA/WDMA/CSA 101/1.5.2/A440
or has infiltration rates per NFRC ['Not Observable
400 that do not exceed code El Not Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies
[FR16]2 sealed at housing/interior finish DDoes Not
and labeled to indicate<_2.0 cfm
leakage at 75 Pa. ONot Observable
ONot Applicable
403.3.1 Supply and return ducts in attics ❑Complies
[FR12]1 insulated>=R-8 where duct is DDoes Not
>= 3 inches in diameter and >=
R-6 where < 3 inches.Supply and ONot Observable
return ducts in other portions of ONot Applicable
the building insulated>= R-6 for
diameter>=3 inches and R-4.2
for<3 inches in diameter.
403.3.5 Building cavities are not used as DComplies
[FR15]3 ducts or plenums. DDoes Not
k+. ONot Observable
ONot Applicable
403.4 HVAC piping conveying fluids R- R- ❑Complies
[FR17j2 above 105 4F or chilled fluids DDoes Not
below 55 4F are insulated to>_R-
`) 3 ['Not Observable
ONot Applicable
403.4.1 Protection of insulation on HVAC ❑Complies
[FR24]1 piping. ❑Does Not
❑Not Observable
ONot Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies
[FR18]2 >_R-3. DDoes Not
t_' ONot Observable
ONot Applicable
403.6 Automatic or gravity dampers are ❑Complies
[FR19]2 installed on all outdoor air DDoes Not
intakes and exhausts.
ONot Observable
ONot Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Stockton Report date: 07/16/19
Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\79 Richmond Hills Drive.rck Page 4 of 9
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Stockton Report date: 07/16/19
Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\79 Richmond Hills Drive.rck Page 5 of 9
•
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
303.1 All installed insulation is labeled ❑Complies
[IN13)2 or the installed R-values ❑Does Not
provided.
['Not Observable
ONot Applicable
402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values.
[IN1]1 ❑ Steel 0 Steel ❑Not Observable
co.,
❑Not Applicable
303.2, Floor insulation installed per ❑Complies
402.2.7 manufacturer's instructions and DDoes Not
[IN2]1 in substantial contact with the
u, underside of the subfloor,or floor ❑Not Observable
framing cavity insulation is in ❑Not Applicable
contact with the top side of
sheathing,or continuous
insulation is installed on the
underside of floor framing and
extends from the bottom to the
top of all perimeter floor framing
members.
402.1.1, Wall insulation R-value.If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least Y2 of the ❑ wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable
[IN3]1 exterior,the exterior insulation
tip, requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies
[IN4]1 manufacturer's instructions. ❑Does Not
['Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Stockton Report date: 07/16/19
Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\79 Richmond Hills Drive.rck Page 6 of 9
•
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood DDoes Not table for values.
402.2.2, ❑ Steel ❑ Steel ['Not Observable
402.2.E[FI1] ❑Not Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies
303.2 manufacturer's instructions. DDoes Not
[F12]1 Blown insulation marked every
300 ft2. Not Observable
❑Not Applicable
402.2.3 Vented attics with air permeable ❑Complies
[FI22]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that
extends over insulation. ❑Not Observable
❑Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies
[FI3]1 insulation>_R-value of the DDoes Not
adjacent assembly.
❑Not Observable
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ❑Complies
[F117]1 ach in Climate Zones 1-2,and DDoes Not
<=3 ach in Climate Zones 3-8.
❑Not Observable
CI Not Applicable
403.3.4 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies
[F14]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in ❑Not Observable
tests,verification may need to ❑Not Applicable
occur during Framing Inspection.
403.3.3 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies
[F127]1 determine air leakage with ft2 ft2 ❑Does Not
either: Rough-in test:Total
leakage measured with a Not Observable
pressure differential of 0.1 inch ONot Applicable
w.g.across the system including
the manufacturer's air handler
enclosure if installed at time of
test.Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g.across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies
[F124]1 by manufacturer at<=2%of DDoes Not
design air flow.
:Not Observable
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies
[Fl9]2 installed for control of primary ❑Does Not
heating and cooling systems and
initially set by manufacturer to Not Observable
code specifications. ❑Not Applicable
403.1.2 Heat pump thermostat installed ❑Complies
[F110]2 on heat pumps. ODoes Not
❑Not Observable
❑Not Applicable
403.5.1 Circulating service hot water DComplies
[FI11]2 systems have automatic or DDoes Not
accessible manual controls.
['Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Stockton Report date: 07/16/19
Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\79 Richmond Hills Drive.rck Page 7 of 9
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 All mechanical ventilation system DComplies
1F12512 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy
and air flow limits. DNot Observable
❑Not Applicable
403.2 Hot water boilers supplying heat DComplies
[F126]2 through one-or two-pipe heating ❑Does Not
systems have outdoor setback
control to lower boiler water [Not Observable
temperature based on outdoor ONot Applicable
temperature.
403.5.1.1 Heated water circulation systems DComplies
[F128]2 have a circulation pump.The ❑Does Not
system return pipe is a dedicated
return pipe or a cold water supply ❑Not Observable
pipe.Gravity and thermos- ❑Not Applicable
syphon circulation systems are
not present.Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy.Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems DComplies
[FI29]2 comply with IEEE 515.1 or UL ODoes Not
515.Controls automatically
adjust the energy input to the Not Observable
heat tracing to maintain the ❑Not Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that DComplies
[FI30]2 have recirculation pumps that ❑Does Not
pump water from a heated water ['Not Observable
supply pipe back to the heated
water source through a cold ❑Not Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1044F.
403.5.4 Drain water heat recovery units DComplies
(FI31]2 tested in accordance with CSA ❑Does Not
B55.1.Potable water-side
pressure loss of drain water heat ❑Not Observable
recovery units<3 psi for ❑Not Applicable
individual units connected to one
or two showers.Potable water-
side pressure loss of drain water
heat recovery units<2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent DComplies
[F16]1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps.
Does not apply to low-voltage Not Observable
lighting. ❑Not Applicable
404.1.1 Fuel gas lighting systems have ❑Complies
[F123]3 no continuous pilot light. DDoes Not
['Not Observable
❑Not Applicable
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Stockton Report date: 07/16/19
Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\79 Richmond Hills Drive.rck Page 8 of 9
Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 Compliance certificate posted. DComplies
[F1712 ❑Does Not
❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies
[F11813 mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Stockton Report date: 07/16/19
Data filename: C:\Users\jkazl\OneDrive\Documents\REScheck\79 Richmond Hills Drive.rck Page 9 of 9
1 2015 IECC Energy
0Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 21.00
Below-Grade Wall 24.00
Floor 30.00
Ceiling / Roof 49.00
Ductwork (unconditioned spaces):
Glass&Door Rating U-Factor SHGC
Window 0.30
Door 0.19
Heating &Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
ONIIMIIIIIIIIIIIIMIIIIIIIINIIIIIIMIINIMIIIOIIIIIIIIMIIIIIIII
Name: Date:
Comments