ResCheck FILE COPY
. REScheck Software Version 4.6.3 cn co i w
Compliance Certificate co
* 0
p , ,
cie
sy
Project Neew Model Home U E 7 a �, N * o-
11)
Energy Code: 2015 IECC f (n
Location: Glens Falls, New York AU� 1 2Q19 111 N 2.
Construction Type: Single-family __ _ j l XI
Project Type: New Construction +AWN OF QUUE'EW-N--S-B-U.-
RUILDJN GDES �) O
Conditioned Floor Area: 2,405 ft2 G$c f✓ � (A
Glazing Area 12% '•/
Climate Zone: 6 (7635 HDD) 0 N
Permit Date: Co..) ON
Permit Number: N 1"
Construction Site: Owner/Agent: Designer/Contractor:
9 Westberry Way David Howard Ethan Peter Hall
Queensbury, NY 12804 500 Luzerne Road Rucinski Hall Architecture
Queensbury, NY 12804 134 Dix Ave
518-361-0674 Glens Falls, NY 12801
Howard35_2000@yahoo.com 518-741-0268
ephall@nycap.rr.com
Compliance: Passes using UA trade-off
Compliance: 3.5%Better Than Code Maximum UA: 376 Your UA: 363 REVIEWED FOR
The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
ENERGY CODE COMPLIANCE
Envelope Assemblies
Gross Area Cavity Cont.
Assembly or R-Value R-Value U-Factor UA
Perimeter
Ceiling 1: Raised or Energy Truss 1,105 38.0 0.0 0.025 28
Ceiling 2: Raised or Energy Truss 195 38.0 0.0 0.025 5
Wall 1: Wood Frame, 16" o.c. 1,823 21.0 3.6 0.046 71
Window 1: Vinyl/Fiberglass Frame:Double Pane with Low-E 185 0.290 54
Door 1: Solid 38 0.300 11
Door 2: Glass 40 0.320 13
Door 3: Solid 18 0.300 5
Wall 2: Wood Frame, 16" o.c. 1,440 21.0 3.6 0.046 60
Window 2: Vinyl/Fiberglass Frame:Double Pane with Low-E 138 0.290 40
Basement Wall 1: Solid Concrete or Masonry 1,441 0.0 15.0 0.048 68
Wall height: 7.9'
Depth below grade: 6.5'
Insulation depth: 7.5'
Window 3: Vinyl/Fiberglass Frame:Double Pane with Low-E 28 0.290 8
Project Title: Neew Model Home Report date: 08/21/19
Data filename: Y:\Howard Construction\9 Westberry - 2019\9 Westberry Way.rck Page 1 of10
Compliance Statement: The proposed building design described here is consistent with the building plans,specifications, and other
calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in
REScheck Version 4.6.3 and to comply with the mandatory requirements I' ed in the Sch k Ins ection Checklist.
Ethan Peter Hall-Architect
Name-Title Signatu 4 . - Date
J*
L 4i
Project Title: Neew Model Home Report date: 08/21/19
Data filename: Y:\Howard Construction\9 Westberry - 2019\9 Westberry Way.rck Page 2 of10
. REScheck Software Version 4.6.3
Inspection Checklist
Energy Code: 2015 IECC
Requirements: 100.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Section Plans Verified Field Verified
# Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions
& Req.ID
103.1, Construction drawings and EComplies Requirement will be met.
103.2 documentation demonstrate ❑Does Not
[PR1]1 energy code compliance for the ❑Not Observable Location on plans/spec: A-
building envelope.Thermal 1
envelope represented on ENot Applicable
construction documents.
103.1, Construction drawings and ❑Complies Requirement will be met.
103.2, documentation demonstrate EDoes Not
403.7 energy code compliance for ENot Observable Location on plans/spec: A-
[PR3]' lighting and mechanical systems. 1
d Systems serving multiple ENot Applicable
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met.
403.7 sized per ACCA Manual S based Btu/hr Btu/hr ElDoes Not
[PR2)2 on loads calculated per ACCA Cooling: Cooling: ENot Observable Location on plans/spec: A-
t* Manual J or other methods Btu/hr Btu/hr 1
approved by the code official. ❑Not Applicable
Additional Comments/Assumptions:
(1 IHigh Impact (Tier 1) 12 IMedium Impact(Tier 2) 1 3 row Impact(Tier 3)
Project Title: Neew Model Home Report date: 08/21/19
Data filename: Y:\Howard Construction\9 Westberry - 2019\9 Westberry Way.rck Page 3 of10
Section Plans Verified Field Verified
# Foundation Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1 Conditioned basement wall R- R- EComplies See the Envelope Assemblies
[F04]1 insulation R-value. Where interior R- R- EDoes Not table for values.
insulation is used,verification ❑Not Observable
may need to occur during
Insulation Inspection. Not ❑Not Applicable
required in warm-humid locations
in Climate Zone 3.
303.2 'Conditioned basement wall ❑Complies Requirement will be met.
[F05]1 insulation installed per ElDoes Not
manufacturer's instructions. ❑Not Observable Location on plans/spec: A-
1
❑Not Applicable
402.2.9 Conditioned basement wall ft ft ElComplies See the Envelope Assemblies
[F06]1 insulation depth of burial or CI Does Not table for values.
d distance from top of wall.
[Not Observable
❑Not Applicable
303.2.1 A protective covering is installed ❑Complies Exception: Requirement is
[F011]2 to protect exposed exterior ❑Does Not not applicable.
insulation and extends a
minimum of 6 in. below grade. ❑Not Observable
ONot Applicable
403.9 Snow-and ice-melting system ❑Complies Exception: Requirement is
[F012]2 controls installed. ❑Does Not not applicable.
e ❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 High impact(Tier 1) 1 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3)
Project Title: Neew Model Home Report date: 08/21/19
Data filename: Y:\Howard Construction\9 Westberry - 2019\9 Westberry Way.rck Page 4 of10
Section 1Plans Verified Field Verified
# 'Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions
& Req.ID
402.1.1, Door U-factor. U- U- ❑Complies See the Envelope Assemblies
402.3.4 ❑Does Not table for values.
[FR1]1 ❑Not Observable
❑Not Applicable
402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies
402.3.1, average). ❑Does Not table for values.
402.3.3,
402.3.6, :Not Observable
402.5 ❑Not Applicable
[FR2]1
V
303.1.3 U-factors of fenestration products ❑Complies Requirement will be met.
[FR4]1 are determined in accordance ❑Does Not
with the NFRC test procedure or ❑Not Observable Location on plans/spec:A-
taken from the default table. 1
ENot Applicable
402.4.1.1 Air barrier and thermal barrier ❑Complies Requirement will be met.
[FR23]1 installed per manufacturer's ❑Does Not
instructions. Location on plans/spec: A-
❑Not Observable 1
❑Not Applicable
402.4.3 Fenestration that is not site built ElComplies Requirement will be met.
[FR20]1 is listed and labeled as meeting ❑Does Not
0 AAMA/WDMA/CSA 101/I.5.2/A440 ❑Not Observable
or has infiltration rates per NFRC
400 that do not exceed code ENot Applicable
limits.
402.4.5 IC-rated recessed lighting fixtures ❑Complies Exception: Requirement is
[FR16]2 sealed at housing/interior finish ❑Does Not not applicable.
and labeled to indicate 52.0 cfm
leakage at 75 Pa. ❑Not Observable
ENot Applicable
1403.2.1 Supply and return ducts in attics ❑Complies Exception: Ducts located
1[FR12]' insulated >= R-8 where duct is ElDoes Not completely inside the
d >= 3 inches in diameter and >= ['Not Observable building envelope.
R-6 where < 3 inches. Supply and
return ducts in other portions of ❑Not Applicable
the building insulated >= R-6 for
diameter>= 3 inches and R-4.2
for< 3 inches in diameter.
403.3.3.5 Building cavities are not used as ❑Complies 'Requirement will be met.
[FR15]3 ducts or plenums. EDoes Not
d ❑Not Observable Location on plans/spec:A-
ONot Applicable 1
403.4 HVAC piping conveying fluids R- R- ❑Complies Exception: Requirement is
[FR17]2 above 105 QF or chilled fluids ❑Does Not not applicable.
below 55 4F are insulated to zR- [Not Observable
❑Not Applicable
403.4.1 Protection of insulation on HVAC ❑Complies Exception:Requirement is
[FR24]1 piping. ❑Does Not not applicable.
V [Not Observable
❑Not Applicable
403.5.3 Hot water pipes are insulated to R- R- ❑Complies Requirement will be met.
[FR18]2 zR-3. ❑Does Not
d ❑Not Observable Location on plans/spec:A-
1
ENot Applicable
403.6 Automatic or gravity dampers are ❑Complies Requirement will be met.
[FR19]2 installed on all outdoor air ❑Does Not
intakes and exhausts. Location on plans/spec:A-
i- ❑Not Observable 1
ENot Applicable
High Impact(Tier 1) [2jMedium Impact(Tier 2) 3JLow Impact(Tier 3)
Project Title: Neew Model Home Report date: 08/21/19
Data filename: Y:\Howard Construction\9 Westberry - 2019\9 Westberry Way.rck Page 5 of10
Additional Comments/Assumptions:
1THigh Impact(Tier 1) 121Medium Impact(Tier 2) T 3TLow Impact (Tier 3)
Project Title: Neew Model Home Report date: 08/21/19
Data filename: Y:\Howard Construction\9 Westberry - 2019\9 Westberry Way.rck Page 6 of10
Section Plans Verified Field Verified
# Insulation Inspection Value Value Complies? Comments/Assumptions
& Req.ID — —
303.1 All installed insulation is labeled ❑Complies 'Requirement will be met.
[IN13)2 or the installed R-values EDoes Not
U: provided. :Not Observable
❑Not Applicable
402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies
402.2.5, mass wall with at least 1/2 of the El Wood ❑ Wood ❑Does Not table for values.
402.2.6 wall insulation on the wall 0 Mass ❑ Mass ❑Not Observable
[IN3]1 exterior, the exterior insulation
requirement applies(FR10). ❑ Steel ❑ Steel ❑Not Applicable
303.2 Wall insulation is installed per ❑Complies Requirement will be met.
[IN4]1 manufacturer's instructions. ❑Does Not
❑Not Observable Location on plans/spec: A-
1
DNot Applicable
Additional Comments/Assumptions:
1 High Impact(Tier 1) 121Medium Impact(Tier 2) 1 3 ILow Impact(Tier 3) 1
Project Title: Neew Model Home Report date: 08/21/19
Data filename: Y:\Howard Construction\9 Westberry - 2019\9 Westberry Way.rck Page 7 of10
• Section Plans Verified Field Verified
# Final Inspection Provisions Value Value
& Req.ID Complies? Comments/Assumptions
402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies
402.2.1, ❑ Wood ❑ Wood ❑Does Not table for values.
402.2.2,
402.2.E ❑ Steel ❑ Steel ENot Observable
[Mr ENot Applicable
303.1.1.1, Ceiling insulation installed per ❑Complies Requirement will be met.
303.2 manufacturer's instructions. ❑Does Not
[FI2]1 Blown insulation marked every Location on plans/spec: A-
300 ft2. Not Observable 1
ENot Applicable
402.2.3 Vented attics with air permeable ❑Complies Requirement will be met.
[FI22]2 insulation include baffle adjacent ❑Does Not
to soffit and eave vents that Location on plans/spec:A-
extends over insulation. ❑Not Observable 1
:Not Applicable
402.2.4 Attic access hatch and door R- R- ❑Complies Requirement will be met.
[F13]1 insulation R-value of the ❑Does Not
adjacent assembly. Location on plans/spec:A-
, ENot Observable 1
❑Not Applicable
402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50= ACH 50 = ❑Complies Requirement will be met.
[FI17]1 ach in Climate Zones 1-2, and ❑Does Not
<=3 ach in Climate Zones 3-8. Location on plans/spec:A-
ENot Observable 1
❑Not Applicable
403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Exception:All ducts and air
[FI4]1 cfm/100 ft2 across the system or ff ft7— ❑Does Not handlers are located within
<=3 cfm/100 ft2 without air ENot Observable conditioned space.
handler @ 25 Pa. For rough-in
tests,verification may need to ENot Applicable
occur during Framing Inspection.
403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Exception: All ducts and air
[F12711 determine air leakage with ft2 ft2 ❑Does Not handlers are located within
either: Rough-in test:Total ENot Observable conditioned space.
leakage measured with a
pressure differential of 0.1 inch ElNot Applicable
w.g. across the system including
the manufacturer's air handler
enclosure if installed at time of
test. Postconstruction test:Total
leakage measured with a
pressure differential of 0.1 inch
w.g. across the entire system
including the manufacturer's air
handler enclosure.
403.3.2.1 Air handler leakage designated ❑Complies Requirement will be met.
[FI24]1 by manufacturer at<=2°/a of ❑Does Not
design air flow. Location on plans/spec: A-
ENot Observable 1
❑Not Applicable
403.1.1 Programmable thermostats ❑Complies Requirement will be met.
[FI912 installed for control of primary ❑Does Not
heating and cooling systems and Location on plans/spec: A-
initially set by manufacturer to Not Observable 1
code specifications. ENot Applicable
403.1.2 Heat pump thermostat installed ❑Complies Exception: Requirement is
[FI10]2 on heat pumps. ❑Does Not not applicable.
ENot Observable
❑Not Applicable
403.5.1 Circulating service hot water ❑Complies Exception:Requirement is
[FI11]2 systems have automatic or ❑Does Not not applicable.
accessible manual controls.
ENot Observable
ENot Applicable
1 THigh Impact(Tier 1) 2 Medium Impact (Tier 2) 1 3 Low Impact(Tier 3) 1
Project Title: Neew Model Home Report date: 08/21/19
Data filename: Y:\Howard Construction\9 Westberry - 2019\9 Westberry Way.rck Page 8 of10
•
Section Plans Verified Field Verified
Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
403.6.1 All mechanical ventilation system EComplies Requirement will be met.
[F125]2 fans not part of tested and listed ❑Does Not
HVAC equipment meet efficacy ENot Observable Location on plans/spec: A-
and air flow limits. 1
❑Not Applicable
403.2 Hot water boilers supplying heat EComplies Exception: Requirement is
[F126]2 through one-or two-pipe heating ❑Does Not not applicable.
systems have outdoor setback
control to lower boiler water [Not Observable
temperature based on outdoor ENot Applicable
temperature.
403.5.1.1 Heated water circulation systems EComplies Exception: Requirement is
[FI28]2 have a circulation pump.The ❑Does Not not applicable.
system return pipe is a dedicated
return pipe or a cold water supply Not Observable
pipe. Gravity and thermos- ENot Applicable
syphon circulation systems are
not present. Controls for
circulating hot water system
pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop
is at set-point temperature and
no demand for hot water exists.
403.5.1.2 Electric heat trace systems EComplies Exception: Requirement is
[F129]2 comply with IEEE 515.1 or UL ❑Does Not not applicable.
515. Controls automatically
adjust the energy input to the ENot Observable
heat tracing to maintain the ENot Applicable
desired water temperature in the
piping.
403.5.2 Water distribution systems that EComplies Exception: Requirement is
[F130]2 have recirculation pumps that ❑Does Not not applicable.
pump water from a heated water
supply pipe back to the heated Not Observable
water source through a cold ENot Applicable
water supply pipe have a
demand recirculation water
system. Pumps have controls
that manage operation of the
pump and limit the temperature
of the water entering the cold
water piping to 1044F.
403.5.4 Drain water heat recovery units ❑Complies Requirement will be met.
[F131]2 tested in accordance with CSA ElDoes Not
B55.1. Potable water-side Location on plans/spec: A-
pressure loss of drain water heat 1
recovery units < 3 psi for ENot Applicable
individual units connected to one
or two showers. Potable water-
side pressure loss of drain water
heat recovery units < 2 psi for
individual units connected to
three or more showers.
404.1 75%of lamps in permanent EComplies Requirement will be met.
[F16)1 fixtures or 75%of permanent ❑Does Not
fixtures have high efficacy lamps. Location on plans/spec: A-
Does not apply to low-voltage 1
lighting. ENot Applicable
404.1.1 Fuel gas lighting systems have ❑Complies Requirement will be met.
[F123]3 no continuous pilot light. ❑Does Not
d' ENot Observable Location on plans/spec: A-
1
ENot Applicable
1 'High Impact(Tier 1) 2 Medium Impact(Tier 2) 13TLow Impact(Tier 3)
Project Title: Neew Model Home Report date: 08/21/19
Data filename: Y:\Howard Construction\9 Westberry - 2019\9 Westberry Way.rck Page 9 of10
• Section Plans Verified Field Verified
# Final Inspection Provisions Value Value Complies? Comments/Assumptions
& Req.ID
401.3 Compliance certificate posted. ❑Complies Requirement will be met.
[FI7)2 ❑Does Not
❑Not Observable
❑Not Applicable
303.3 Manufacturer manuals for ❑Complies Requirement will be met.
[FI18)3 mechanical and water heating ❑Does Not
systems have been provided.
❑Not Observable
❑Not Applicable
Additional Comments/Assumptions:
1 I High Impact(Tier 1) 2 I Medium Impact(Tier 2) 3 Low Impact(Tier 3)
Project Title: Neew Model Home Report date: 08/21/19
Data filename: Y:\Howard Construction\9 Westberry -2019\9 Westberry Way.rck Page 10 of10
2015 IECC Energy
Efficiency Certificate
Insulation Rating R-Value
Above-Grade Wall 24.60
Below-Grade Wall 15.00
Floor 0.00
Ceiling / Roof 38.00
Ductwork (unconditioned spaces):
Glass &Door Rating U-Factor SHGC
Window 0.29
Door 0.32
Heating & Cooling Equipment Efficiency
Heating System:
Cooling System:
Water Heater:
Name: Date:
Comments