2008-211 TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518) 761-8201
Community Development- Building &Codes (518) 761-8256
CERTIFICATE OF OCCUPANCY
Permit Number. P20080211 Date Issued: Thursday, April 01, 2010
This is to certify that work requested to be done as shown by Permit Number P20080211
has been completed.
Location: 44 BURCH Rd
Tax Map Number. 523400-308-006-0001-072-002-0000
Owner. CHRISTOPHER CONNELLY
Applicant: CHRISTOPHER CONNELLY
This structure maybe occupied as a:
Garage Detached By Order of Town Board
TOWN OF QUEENSBURY
Issuance of this Certificate of Occupancy DOES NOT relieve the J W �ot
property owner of the responsibility for compliance with Site Plan,
Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement
Planning Board or Zoning Board of Appeals.
TOWN OF QUEENSBURY
742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201
Community Development- Building&Codes (518) 761-8256
BUILDING PERMIT
Permit Number: P20080211 Application Number. A20080211
Tax Map No: 523400-308-006-0001-072-002-0000
Permission is hereby granted to: CHRISTOPHER CONNELLY
For property located at: 44 BURCH Rd
in the Town of Queensbury,to construct or place
at the above location in accordance with application together with plot plans and other information hereto filed
and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning
Ordinance. Tyne of Construction Value
Owner Address: CHRISTOPHER CONNELLY
44 BURCH Rd Garage Detached $8,000.00
QUEENSBURY,NY 12804-0000 Total value $8,000.00
Contractor or Builder's Name/Address Electrical Inspection Agency
FRED SMITH
23 VERMONT Ave
QUEENSBURY, NY 12804-0000
Plans &Specifications
2008-211
896 SQ FT GARAGE
$89.60 PERMIT FEE PAID- THIS PERMIT EXPIRES: Tuesday, May 19, 2009
(If a longer period is required,an application for an extension must be made to the code Enforcement Officer
of the Town of Queensbury before the expiration date.)
Dated at the wn o ee lur �e , May 19, 2008
SIGNED BY for the Town of Queensbury.
Director of Building&Code Enforcement
�.. ............................... .............---------. ti I ..i.............. } ....r
OFFICE USE ONLY
' { 1&Y 3 2008
TAX MAP NO. C—PERMIT NO.
ENSBIJRY
FEE PAID � O - (!Q BLDG,&CODES APPROVAL 8U I L I�,
.----------------------_._........................
..._._.........!
ACCESSORY STRUCTURE BUILDING PERMIT APPLICATION
Use this application for any structure other than the Principal Structure(house)to include, but
not limited to: garage, shed, greenhouse, dock, deck, etc. Refer to Informational Brochure No. 3
entitled Accessory Structures-Sheds/Fences.
A PERMIT MUST BE OBTAINED BEFORE WORK BEGINS.APPLICATION IS SUBJECT TO REVIEW BEFORE
ISSUANCE OF A VALID PERMIT.NO INSPECTIONS WILL BE MADE UNTIL THE APPLICANT HAS
RECEIVED A VALID BUILDING PERMIT.
OWNER: L'h� A-Ptrn, INSTALLER/BUILDER: Frittj
ADDRESS: _ 11Lj � ADDRESS: lkrvyc-;k- jk� �A�A n��I
PHONE NOS. 7�(3'SY27� PHONE NOS.
LOCATION OF PROPERTY: 44 SUBDIVISION NAME: N -..
LOCATION OF PROPOSED CONSTRUCTION AND/OR INSTALLATION: q4j t3Lc/t-� Ili._t
ESTIMATED COST OF CONSTRUCTION: $_ O,Q�-b'r ANY OTHER ACCESSORY STRUCTURES ON PROPERTY? S �
IF YES,PLEASE LIST: L5 \ flow IQxL 10
I /s
CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: COhrex4 PHONE: -74 T-cSC9
PROPOSED CONSTRUCTION 13r FLOOR 2Nu PROPOSED
FLOOR TOTAL HEIGHT
SQ.FT SQ.FT. SQ.FT. FT.&IN.
OPEN PORCH
DECK
3 SEASON,COVERED OR ENCLOSED PORCH'
BOATHOUSE
BOATHOUSE WITH SUNDECK
DOCK
SHED
POLE BARN
DETACHED GARAGE(NO.OF CARS: ) � N ...• gl(� �� . ��!
OTHER ACCESSORY STRUCTURE:
*CONSIDERED FLOOR AREA&MUST COMPLY WITH FAR[FLOOR AREA RATIO]REQUIREMENTS IF THE
STRUCTURE IS LOCATED IN THE WATERFRONT RESIDENTIAL ZONE.
To the best of my knowledge,the statements contained in the application,together with the plans
and specifications submitted, are a true and complete statement of all proposed work to be done
on the described premises and that all provisions of the Building Codes,the Zoning Ordinance,
and all other laws pertaining to the proposed work shall be complied with,whether specified or
noted, and that such work is authorized by the owner. Further, it is understood that I/we shall
submit prior to a Certificate of Occupancy or Certificate of Compliance being issued, as requested
by the Zoning Administrator or Director of Building and Codes, an As-Built Survey by a licensed
surveyor, drawn to scale, showing actual location of all new
construction.
QUESTIONS? CALL 761.8256 OR EMAIL
I have read and agree to a above. codes0gWeensburv.net
VISIT OUR WEBSITE FOR MORE INFORMATION
Signed Dated: 3 �� www.aueensbury.net
Town of Queensbury- Community Development Office- 742 Bay Road, Queensbury, NY 12804
B 1-LGL 11-05
ELEVATION
c 9 � ' L�
e 99 s>V NSBUR. ;
BUIL N' CODES
VAA
CROSS SECTION
�yPb OJ CT IT A '
ate►�- ALL IM � R
TH
,n x QLRATIO O
j2 C N
P�
El
-i
r
t f
fl
I I f I I— .-
FOUNDATION PLAN
6 INCH SOLID CONCRETE SLAB
Rcea Aar E � ,
�
_._�.. -_ __ _______ ._- 1 �►�� _
2 ROWS OF 1/2 INCH REED BAR AROUND OUTSIDE/FOOOTER
AREA
r`
2 ROWS OF 8 INCH CEMENT BLOCKS TOPPED OFF WITH CAP
BLOCK
�--- I f6w b1ocY�,
FLOOR PLAN
28X36 DETACHED GARAGE
Vu cty, eivnawo vrt S*Oir
5�12 roof �k)n f;..00ry me -lt. -4n41?4
w mJ�
Door
floor
Door I fcx3k L Acv, ci w'
7 Aab iRA 74�L#-MM
QueensburyBuilding & Code Enforcement - Residential Final Inspection
Office No. (518)761-8256 Arrive: am/pm Departl-i�, D am/pm
Date Inspection request received: Inspector's Initials:
NAME: PERMIT#:
LOCATION: DATE:
TYPE OF STRUCTURE:
Comments:
N N/A
4' Building Number Address visible from roadex
Chimney Height/'B'Vent/Direct Vent Location p
Fresh Air Intake /
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors _
Handrail 4 or more risers
Guards at stairs decks ios more than-30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wail
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate
Gas Valve shut-off gnm
jLd/re ulator 18 inches above grade
Interior privacy/trim/doors/main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells salety glazing
Interior Smoke Detectors I Carbon Monoxide Detectors
Every level: Every Bedroom:Outside every every bedroom area:
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access 1 sq.ft.-150 sq.ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stoppiEg finished basement 1,000 sq.ft. �--
Emeraency egress below grade 1
Gas Furnace shut-off within 30 feet or within line of site
Oil Furnace shut-off at entrance to furnace area
Fumace/Hot Water Heater operating
Low water shut-off bailer
Relief Valves installed/Heat Tra Water Temp 110
Enclosed Stairs Sheetroc k Underside minimum W Gypsum
Basement stairs closed rise>4 inches
Garage Floor Pitched
Gars a fire roofi /%hour fire door/door closer
Duct work Sealed ro d
sFEleweWcal
ed or Glass Enclosure
FinaPlan
Arc r in Bedrooms
Flexndin
As Built Sept is System/Sewer Dept. Ins ion Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C/C or C 10 Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\Inspection FonnsWesidential Final Inspection Forrn_revise0_100405.doc;Revised
January 7,2008;Revised 6/28/08
Queensbury Building & Code Enforcement - Residential Final Inspection
Office No. (518)761-8256 Arrive: am/prp Depart:��l`'�am/pm
Date Inspection request received: Inspector's Initials: /'
NAME: ' ` -- PERMIT#:
LOCATION: DATE:
TYPE OF STRUCTURE:
Comments:
Yes N NIA
4' Building Number Address visible from road
Chimney Height/"B"Vent/Direct Vent Location
Fresh Air Intake
3 inch Plumbing Vent through roof minimum 6 inches
Roof Complete/Exterior Finish Complete
Platform at all exterior doors
Handrail 4 or more risers
Guards at stairs deckspatios more than 30 inches above grade
Guard at stairwell at 34 inches or more
Guard at deck,porches 36 inches or more
Handrail Termination at Newell Post or Wall
Interior/Exterior Railings 34 inches to 38 inches
Deck Bracing/Handicapped Ramp Compliant
Grade away from foundation 6 inches with 10 feet
6 inch clearance to sill plate _
Gas Valve shut-off exposed I regulator 18 inches above grade
Interior rivac /trim/doors!main entrance 36 inches
Bathroom/Kitchen watertight
Safety glazing/Window in stairwells safety glazing
Interior Smoke Detectors/Carbon Monoxide Detectors
Every level: Every Bedroom:
Outside every bedroom area: _
Inter Connected: Battery backup:
Attic access 30 inches x 22 inches x 30 inches(height)in accessible area
Crawl Spaces 18 inch x 24 inch access, 1 s .ft.-150 s .ft.vents
Bathroom Fans,if no window
Plumbing fixtures
Foundation insulation/Insulation Certification
Floor truss,draft stopping finished basement 1,000 sq.ft.
Emeraency egress below grade ! `�
Gas Furnace shut-off within 30 feet or within line of site t`
Oil Furnace shut-off at entrance to furnace area �- r
Fumace/Hot Water Heater operating
Low water shut-off boiler
Relief Valves installed/Heat Trap/Water Temp 110
Enclosed Stairs Sheetrock Underside minimum'/2"Gypsum W
Basement stairs dosed rise>4 inches
Garage Floor Pitched r-------^
Garage fireproofing/%hour fire door/door closer -
Duct work Sealed prop d
Gas Logs in Sealed or Glass Enclosure
Final Electrical
Final Survey Plot Plan
Arc fault Breaker in Bedrooms
Flex Gas Pipe Bonding
As Built Septic System/Sewer Dept. Inspection Sticker
Site Plan /Variance required
Flood Plain Certification,if required
Okay to issue C I C or C 10 1 Temporary/Permanent
L:\Building&Codes Forms\Building&Codes\Inspection FormsWesidential Final Inspection Forrrn_revised_100405.doc;Revised
January 7,2008; Revised 6/26/08
Framing / Firestopping Inspection Report
Office No. (518)761-8256 Date Ins o uest received:
Queensbury Building Code Enforcement Arrive: am/�part: am/pm
742 Bay Road, Queensbury, NY 12804 Inspecto s Initials:
NAME: l PERMIT#:
LOCATION: r., INSPECT ON: - �--
TYPE OF STRUCTURE:
Framing Y N WA COMMENTS:
Attic ss 22" x 30" minimum
Jack Studs/Headers
Bracing/Bridging
Joist hangers
Jadc Posts/Main Beams
Exterior sheeting nailed properly
12"O.C.
Headroom 6 ft. 8 in.
Stairwells 36 in. or more
Exterior Deck Bracing
Headroom 6 ft. 8 in.
Notches/Holes/Bearing Walls
Metal Strapping for Notches Top Plate
1 '/ w 16 gauge 8 16D nails each side
Draft stopping 1,000 sq. ft. floor trusses
Anchor Bolts 6 ft. or less on center
Ice and water shield 24 inches from wall
Fire separation 1, 2, 3 hour
Fire wall 2, 3, 4 hour
Firestopping
Penetration sealed
16 inch insulation in cavity min.
Garage Fire Separation
House side%inch or 5/8 inch Type X
Garage side 5/8 inch Type X
Ceiling/wall
Windows Habitable Space/Bedrooms
24 in. (H)
20 in. (W)
5.7 sf above/below grade
5.0 sf grade
LABuilding&Codes Forms-01-Muilding&Codes\Inspection FomsTrar ing Firestopping Inspection ReporLdoc Revised January 7,2008
Foundation Inspection Report
Office No.(518)761-8256 Date Inspection request received: _
Queensbury Building&Code Enforcement Arrive: am/p Dep I am/pm
742 Bay Rd.,Queensbury,NY 12804 Inspector's Initials:
NAME: v el,14PERMIT#:
LOCATION: INSPECT ON:
TYPE OF STRUCTURE:
Comments
4!y
Y N N/A
Footings
Monolithic Slab
Reinforcement in Place
The contractor is responsible for
providing protection from freezing
for 48 hours following the placement
of the concrete.
Materials for this purpose on site.
Foundation/Wallpour
Reinforcement in Place (�
Footing Dowels or Keyway in place
Foundation Dampproofing
Foundation Waterproofing
Footing Drain Daylight or Sump
Footing Drain Stone:
12 inch width
6 inches above footing
6 mil poly for wet areas under slab
Backfill Approval
Plumbing Under Slab
PVC/Cast/Copper
Foundation Insulation Interior/Exterior
R-
Rough Grade 6 inch drop within 10 ft.
L:\Building&Codes Foam\Building&Codes\Inspecdon Forms\Foundation Inspection Report.doc