Loading...
2008-247 TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF 0CCUP-A-NCY Permit Number. P20080247 Date Issued: Monday, September 15, 2008 This is to certify that work requested to be done as shown by Permit Number P20080247 has been completed. Location: 384 BAY Rd Tax Map Number. 523400-296-020-0001-043-000-0000 Owner. 130 BIG BOOM RD., LLC Applicant: 130 BIG BOOM RD., LLC This structure may be occupied as a: Commercial Alteration By Oder of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the r property owner of the responsibility for compliance with Site Plan,, Variance, or other issues and conditions as a result of approvals by the Director of Building&Code Enforcement Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080247 Application Number. A20080247 Tax Map No: 523400-296-020-0001-043-000-0000 Permission is hereby granted to: 130 BIG BOOM RD., LLC For property located at: 3 84 BAY Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: 130 BIG BOOM RD., LLC 36 WINDY HILL Rd Commercial Alteration $5,000.00 GLENS FALLS,NY 12801-0000 Total value $5,000.00 Contractor or Builder's Name/Address Electrical Inspection Agency Plans &Specifications 2008-247 commercail alteration- MOVING PAINT BOOTH $50.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Wednesday,June 10, 2009 (If a longer period is required,an application for an extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the own o QueeIr T June 10, 2008 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement .... -0 0. / ....................FFICE USE ONLY, .�' .'`4 /c/ � .. , TAX MAP NO. PERMIT N0. ; i............ rill g FEES: PER ECREATION ENGINEERING (If applicabl .... ............................................. JJ tifa, _l i�p� 9 ..,:PRINCIPAL STRUCTURE: APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION. APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. APPLICANT/BUILDER: AVQl t,L �ClLjk IYLLJ - OWNER: ' a� ��T li L- WCIC,Cji+ ADDRESS: 7,Ct L O t ADDRESS: 13 cuctLL �C PHONE NOS. '7�h -1 C' PHONE NOS. `1 93 —3.9 /1 CONTACT PERSON FOR BUILDING &CODES COMPLIANCE:TCLCK. Vyx) 0 PHONE:'] C 6 LOCATION OF PROPERTY: C,Ct_CI SUBDIVISION NAME: . YlL4 PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT z0 p APPLY TO YOUR z LL p a CCU w u_ PROJECT 00 OJ F O = _ w -j u- u, u- w ¢ a 0 U ES - ICJ z O f- 1- O ~ W w w � z Q Q 04 U) O u_ I— u- a = 06 SINGLE FAMILY TWO-FAMILY MULTI-FAMILY (NO.of UNITS ) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL V ATTACHED GARAGE(1,2,3) OTHER• `�1�11 IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: ESTIMATED CONSTRUCTION COST: (a Gtg ro, FUEL TYPE: A)W� � (6 HEAT TYPE:1; LY" -HOW MANY FIREPLACE(S): _.AND/OR WOODSTOVES(S): ZONING CATEGORY: 0 C'S n ARE THERE WETLANDS ON THIS SITE? -r--O IS THIS A HISTORIC SITE? PROPOSED USE OF BUILDING OR ADDITION: u t`y1, i.4l�, Qw \y- COD �q6 �1 1 'Please complete a separate Application for"Fuel Burning Appliances&Chimneys" available in our office B 3-LGL 11-05 Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete state me nt/d escri ptio n of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand that I/we are required to provide an as-built survey by a licensed land surveyor of all newly constructed facilities prior to issuance of a certificate of occupancy. I have read and a e to the ove. Signed Director of Building & Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoninq Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) ;................... ; Permission is hereby granted to the above ; This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said ; zoning Laws of the Town of Queensbury. Application: ; 01 , / , , , BUILDING & C OVAL ZONING APPROVAL S , , , , , , DAT ; DATE , , i .....................................................0 QUESTIONS? CALL 761-8256 OR EMAIL codes -gueensbury.net Office Use Only VISIT OUR WEBSITE FOR MORE INFORMATION www.gueensbury.net Operating Permit Issued: Yes No Occupancy Type: Construction Classification: Assembly Occupancy Limit: _ Special Conditions: Town of Queensbury • Community Development Office • 742 Bay Road, Queensbury, NY 12804 i Inspection for Permit to Occupy Fire Marshal's 0i111Ce Request Rec'd Permit No, O - 2 / 7 Town of Queensbury 742 Bay Road t� Queensbury,NY 12804 Scheduled inspection Date: rime: y Phone: (518)761-M Business game: V'ZZ-4A `7 Fax: (518)745-4437 Location: A Tes INo EXITS: Exit Access COMMENTS Exit Enclosure Exit Discharge AISLES: Main Aisle Width Secondary Aisle Width EXIT SIGNAGE Si -n©rrndRM -bait �+.......Y..�....r..._,... i EVAC signs in rooms F- Ntd Cit.< r��q�: TRUSS ID SiGNAGE sh ` g ez W W � EMERGENCY LIGHTING RR FiRE WINGUISHER: �U Hun InMection of extinguisher FIRE ALARM SYSTEM Fan Shutdown Fire ler System Fire$ ression-kitchen Fire S ession Gonerator Hood installation Elevator interior Finishes ? ...Storm e Compreseed Gas Clearance to SpdnkJers Clearance to Electrical Electric Whing Enclosed/Labeled ' Combustible Waste Vehicle Lyipoct Protection Knox Box F.D.Sign age-Utility Rooms No Smoking Signs Maximum Occupancy Sign Bmffkency Evacuation Plan Approved (if no other approvals apply,the B&C Office will issue the Certificate of Occupancy) Q Den' /argil for Recheck � Ins B LAFireMarsha1\New Folder\permitto occupyform.doc l h v, ('s Commercial Final In ection Report Office No.: (518) 761-8256 Date Inspection request received: Queensbury Building&Code Enforcement Arrive: - ,G✓ am/MP7 Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: , G AAp PERMIT#: g �` , ?L - LOCATION: 62 DATE: 7' COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior/Exterior Guardrails 42 in. Platform/Decks _ Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in./Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s . ft. All Doors 36 in.wiLever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 w)x 44"(1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 %doors > 10%> 1000 s . ft. 3/a Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 s . ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan,if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in. Beyond (Both sides] Active Listening System and Signage Assembly Space Final Electrical +/ Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if reg. As-built Septic System Layout Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler - Building Access All Sides by 20' /Driveable Surface 20'wide Okay To IspacMZiN or Permanent C/O Okay T sue C/ L:\BuikUn odes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc Inspection for Permit to Occupy We Moshd's Office Request Rec'd Permit No� Town of QueeRoad bury Oil 742 Bay Road �� (�`�) Queensbury,NY 12&9 Scheduled Inspection Date: -7 `� Time: Phone: (518)761-M Business Name: G Fax: (518)745-4437 Location: 7- _ at N A Yes No EXITS: Exit Access Enclosure COMMENTS Exit Exit Discharge AISLES: Main Aisle Width Secondary Aisle Width EXIT SIGNAGE Si -normal Si -baftery EVAC s1ws in rooms TRUSS ID SIGNAGE EMERGENCY LIGHTING FIRE EVINGUISHER: Hun Inspection of extin 'sher FIRE ALARM SYSTEM Fan Shutdown Fire ler System Fire Suppression-kitchen Fire Suppression r Generator Hood Installation Elevator Interior Finishes Storage Compressed Gas Clearance to§Rdnklers Clearance to Electrical n 4 Electric Wirina Enclosed/Labeled N4 4 Combustible Waste r..�Qy �14ri � �tiwc14- Vehicle Impact Protection Knox Box F.D.Si e-Utility Rooms No Smoking Signs Maximum Occupanc Sign Emergency Evacuafion Plan v Approved (if no other approvals apply,the B&C Office wiH issue a cote of Occupancy) u Denied /call for Recheck Inspected By: L:\FIreMarshal\New Foider\pern-itto occupyform.doc Inspection for Permit to Occupy Fire Mcnhad's (Mce Request Rec'd Permit No. ae Town of Queensbury 742 Bay Road Quee sbury,NY 12804 Scheduled Inspection Date: Time: Phone: (518) 761-8206 Business Name: yc rT Fax: (518) 745-4437 Location: 3 'M__GZed Two of N/A Iles Ko I EXITS: _ Exit Access Exit Enclosure --^�� COMMENTS Exit Discharge AISLES: _ Main Aisle Width Secondary Aisle Width ` EXIT SIGNAGE Si -normal Sign-batter EVAC signs in rooms TRUSS ID SIGNAGE EMERGENCY LIGHTING FIRE EXTINGUISHER: SA �" Hun Inspection of extinguisher T FIRE ALARM SYSTEM Fan Shutdown Fire Sprinkler System Fire Suppression-kitchen Fire Suppression-Gas Islan Generator Hood Installation Elevator i G� Interior Finishes OIL- Storage Compressed Gas Clearance to Sprinklers Clearance to Electrical Electric Wiring Enclosed/Labeled Combustible Waste Vehicle Impact Protection Knox Box F.D.Si na e-Utility Rooms No Smoking Signs _ Maximum Occupancy Simon ` Emergency Evacuation Plan Approved (If no other approvals apply,the B&C Office wilt issue t erti' ate of Occu ancy) a Denied / call for Recheck C\ Inspected By: L:\FireMarshal\New Folder\permitto occupyform.doc Inspepribn for Permit to Occupy Fire Marshal's Office Request Rec'd Permit No. 0S, a 9�7 Town of Queensbury 742 Bay Road i 3b Queensbury,NY 12804 Scheduled inspection Date: Time: Phone: (518)761-8206 Business Name: Fax: (518) 745-4437 Location: Type of Inspection N/A Yes No EXITS: Exit Access DO Enclosure COMMENTS Exit Discharge AISLES: Main Aisle Width Secondary Aisle Width EXIT SIGNAGE Si —normal Sign-battery EVAC signs in rooms TRUSS ID SIGNAGE rp, EMERGENCY LIGHTING FIRE EXTINGUISHER: Hung Inspection of extinguisher Cr M FIRE ALARM SYSTEM Fan Shutdown Fin n Fire Suppression—kitchen Ejc I n Fire Suppression—Gas Islan Generator Hood Installation Elevator C, Interior Finishes Storage Compressed Gas Clearance to Sprinklers Clearance to Electrical log Electric Wirling Enclosed Aabeled ✓ Combustible Waste Vehicle Impact Protection Knox Box F.D.Signage—Utility Rooms No Smoking Signs Maximum Occupancy Sign, Emergency Evacuation Plan VC I PC fL U i9 u Approved (if no other approvals apply,the B&C Office Will issue the Certificate of Occupancy) a Denied / call for Recheck A (b J /inspected By: op L:\FlreMarshal\New Folder\permitto occupyform.doc Commercial Final Inspection Report Office No.: (518) 761-8256 Date Inspection request received: Queensbury Building& Code Enforcement Arrive: !31 am/pm Depart: am/pm 742 Bay Road,Queensbury,NY 12804 Inspector's Initials: NAME: -Y.- _ PERMIT#: ?_z�7 LOCATIO DATE:7 w COMMENTS: Y N NA Chimney/"B"Vent/Direct Vent Location Plumbing Vent Through Roof 6"/Roof Complete Exterior Finish/Grade Complete 6"in 10' or Equivalent Interior-/Exterior Guardrails 42 in. Platform/Decks _ Interior/Exterior Ballisters 4 in. Spacing Platform/Decks Stair Handrail 34 in.—38 in. /Step Risers 7"/Treads 11" Vestibules For Exit doors>3000 s . ft. All Doors 36 in.w/Lever Handles/Panic Hardware,if required Exits At Grade Or Platform 36 (w)x 44" 1)/Canopy or Equiv. Gas Valve Shut-off Exposed&Regulator 18" Above Grade Floor Bathroom Watertight/Other Floors Oka Relief Valve,Heat Trap/Water Temp. 110 Degrees Maximum Boiler/Furnace Enclosure 1 hr. or Fire Extinguishing System Fresh Air Supply for Occupancy/Ventilation Combustion Low Water Shut Off For Boilers Gas Furnace Shut Off Within 30 ft. or Within Line Of Site Oil Furnace Shut Off at Entrance to Furnace Area Stockroom/Storage/Receiving/Shipping Room(2 hr.), 1 '/z doors > 10%> 1000 s . ft. 3/4 Hour Corridor Doors&Closers Firewalls/Fire Separation,2 Hour, 3 Hour Complete/Fire Dampers/Fire Doors Ceiling Fire Stopping, 3,000 s . ft. Wood Frame Attic Access 30"x 20"x 30"(h),Crawl Space Access 18"x 24" Smoke Vents Or Fan, if required Elevator Operation and Si a e/Shaft Sealed Handicapped Bathroom Grab Bars/Sinks/Toilets Handicapped Bath/Parking Lot Si na e Public Toilet Room Handicapped Accessible Handicapped Service Counters, 34 in., Checkout 36" Handicapped Ramp/Handrails Continuous/12 in.Beyond[Both sides] Active Listening System and Signage Assembly Space 01 Final Electrical Ins �ec�rlte Site Plan/Variance required Final Survey,New Structure/Flood Plain certification,if reg. As-built Septic System La out Required or On File Building Number or Tenant Address on Building or Driveway Water Fountain or Cooler Building Access All Sides by 20' /Driveable Surface 20'wide Okay To Issue Temp. or Permanent C/O Okay To Issue C/C L:\Building& Codes Forms\Building&Codes\Inspection Forms\Commercial Final Inspection Report.doc DYELLA f ' www.dellaautogroup.com MAILING ADDRESS: P.O. Box 728 PONTIAC. Glens Falls, NY 12801 `j +v'1 iN 0!- -NAB BUILDING & CODES May 23, 2008 suicx Queensbury Building Department ® Att: Dave Hatin Director The application attached is for permission to update the current paint booth at the Old Formula Body Shop, with a current more technologically advanced paint system. We are moving it from our location on Broad Street in Glens Falls. I have enclosed a check for the permit fee. Thank you for your assistance. Michael Della Bella CHEVROLET President H ISLIZU ILI NCO LN Mercury o HOMDA SALES • SERVICE PARTS LEASING • COLLISION CENTER O D'ELLA PONTIAC GMC O D'ELLA HONDA O D'ELLA LINCOLN O DELLA HONDA 71 CHRISTOPHER CHEVROLET BUICK CADILLAC OF GLENS FALLS MERCURY ISUZU OF PLATTSBURGH BUICK PONTIAC 293 Quaker Road 313 Quaker Road 202 Broad Street 702 Route 3 Upper Wicker Street Queensbury,NY 12804 Queensbury, NY 12804 Glens Falls, NY 12801 Plattsburgh, NY 12901 Ticonderoga, NY 12883 (518) 793.3871 (518) 793.3811 (518) 743.1800 (518)563.7686 (518) 585.2842 (800)462-1968 (888)474.6632 (866) 743.6677 (800) 564.6632 (800)336-0175 FIRE MARSHAL'S OFFICE Town of Queeusbury 742 Bay Roach, Queensbury, NY 12804 " Horne of Natural Beauty ... A Good Place to Live " PLAN REVIEW Della Group 342 Bay Road 2008 247 6/2/2008 I have reviewed the submitted plans for the above project, and offer the following comments: 1) Installation must conform with the requirements on Section 1504 of NYS Fire Code. Details of suppression system and certification of installation will be required, Section 1504.1 and 1504.6. 2) Compliance with section 1504.1.4.3, 1504.1.4.4, 1504.2.1, 1504.2.6 and 1504.6.11 1504.6.2 and 15.4.6.2.1. 04 Fire Marshal Michael J Palmer 742 Bay Road Queensbury NY 12804 518 761 8205 firemarshal@queensbury.net Fi r e M a r s h.a l 's Off i c e • P h o n c: 518-761-8206 • F a x: 518-745-4437 fiz-emarslzal@gucerzsburil.rzet • u7zt7v.queensbun1.net FLAMMABLE FINISHES 1503.3.2 Valves.Containers and piping to which a hose or SECTION 1504 flexible connection is attached shall be provided with a shut- SPRAY FINISHING off valve at the connection. Such valves shall be kept shut 1504.1 Location of spray-finishing operations. Spray-fin- when hoses are not in use. ishing operations conducted in buildings used for Group A,E,I 1503.3.3 Pumped liquid supplies. Where flammable or or R occupancies shall be located in a spray room protected combustible liquids are supplied to spray nozzles by posi- with an approved automatic sprinkler system installed in accor- tive displacement pumps,pump discharge lines shall be pro- dance with Section 903.3.1.1 and separated vertically and hori- vided with an approved relief valve discharging to pump zontally from other areas in accordance with the Building Code suction or a safe detached location. of New York State.In other occupancies,spray-finishing opera- 1503.3.4 Liquid transfer. Where a flammable mixture is tions shall be conducted in a spray room,spray booth or limited transferred from one portable container to another, a bond spraying space approved for such use. shall be provided between the two containers. At least one 1504.1.1 Spray rooms. Spray rooms shall be constructed container shall be grounded.Piping systems for Class I and and designed in accordance with this section and the Build- Class 11 liquids shall be permanently grounded. ing Code of New York State,and shall comply with Sections 1503.3.5 Class I liquids as solvents.Class I liquids used as 1504.2, 1504.3, 1504.4, 1504.5 and 1504.6. solvents shall be used in spray gun and equipment cleaning 1504.1.1.1 Floor. Combustible floor construction in machines which have been listed and approved for the pur- spray rooms shall be covered by approved, pose or shall be used in spray booths or spray rooms in ac- noncombustible, nonsparking material, except where cordance with Sections 1503.3.5.1 and 1503.3.5.2. combustible coverings, such as thin paper or plastic and 1503.3.5.1 Listed devices.Cleaning machines for spray strippable coatings are utilized over noncombustible ma- terials to facilitate cleaning operations in spray rooms. guns and equipment shall not be located in areas open to the public and shall be separated from ignition sources in 1504.1.2 Spray booths. The design and construction of accordance with their listings or by a distance of 3 feet spray booths shall be in accordance with Sections (914 mm),whichever is greater.The quantity of solvent 1504.1.2.1 through 1504.1.2.6, Sections 1504.2 through used in a machine shall not exceed the design capacity of 1504.6,and NFPA 33. the machine. 1504.1.2.1 Construction. Spray booths shall be con- 1503.3.5.2 Within spray booths and spray rooms. structed of approved noncombustible materials. Alumi- When solvents are used for cleaning spray nozzles and num shall not be used. auxiliary equipment within spray booths and spray Where walls or ceiling assemblies are constructed of rooms, the ventilating equipment shall be operated dur- sheet metal, single-skin assemblies shall be no thinner ing cleaning. than 0.0478 inch (18 gage) (1.2 mm) and each sheet of 1503.3.6 Class II and Class III liquids.Solvents used out- double-skin assemblies shall be no thinner than 0.0359 side of spray booths, spray rooms or listed and approved inch(20 gage)(0.9 mm). spray gun and equipment cleaning machines shall be re- Structural sections of spray booths are allowed to be stricted to Class II and Class III liquids. sealed with latex-based or similar caulks and sealants. 1503.4 Operations and maintenance. Spraying areas, ex- 1504.1.2.2 Surfaces. The interior surfaces of spray haust fan blades and exhaust ducts shall be kept free from the booths shall be smooth and shall be constructed so as to accumulation of deposits of combustible residues. Where ex- permit the free passage of exhaust air from all parts of the cessive residue accumulates in booths, ducts, or discharge interior and to facilitate washing and cleaning,and shall points or other spraying areas,spraying operations shall be dis- be designed to confine residues within the booth.Alumi- continued until conditions are corrected. num shall not be used. 1503.4.1 Tools. Scrapers, spuds and other tools used for 1504.1.2.3 Floor. Combustible floor construction in cleaning purposes shall be constructed of nonsparking ma- spray booths shall be covered by approved, terials. noncombustible, nonsparking material, except where 1503.4.2 Residue. Residues removed during cleaning and combustible coverings,such as thin paper or plastic and debris contaminated with residue shall be immediately re- strippable coatings are utilized over noncombustible ma- moved from the premises and properly disposed. terials to facilitate cleaning operations in spray booths. 1503.4.3 Waste cans.Approved metal waste cans equipped 1504.1.2.4 Means of egress. Means of egress shall be with self-closing lids shall be provided wherever rags or provided in accordance with Chapter 10. waste are impregnated with finishing material. Such rags Exception: Means of egress doors from and waste shall be deposited therein immediately after be- premanufactured spray booths shall not be less than ing utilized. The contents of waste cans shall be properly 30 inches(762 mm)in width by 80 inches(2032 mm) disposed of at least once daily and at the end of each shift. in height. 1503.4.4 Solvent recycling.Solvent distillation equipment 1504.1.2.5 Clear space.Spray booths shall be installed used to recycle and clean dirty solvents shall comply with so that all parts of the booth are readily accessible for Section 3405.4. cleaning.A clear space of not less than 3 feet(914 mm) FIRE CODE OF NEW YORK STATE 145 FLAMMABLE FINISHES shall be maintained on all sides of the spray booth.This 1504.2 Ventilation.Mechanical ventilation of spraying areas clear space shall be kept free of any storage or combusti- shall be provided in accordance with Section 510 of the Me- ble construction. chanical Code of New York State. Exceptions: 1504.2.1 Operation.Mechanical ventilation shall be kept 1. This requirement shall not prohibit locating a in operation at all times while spraying operations are being spray booth closer than 3 feet(914 mm)to or di- conducted and for a sufficient time thereafter to allow va- rectly against an interior partition, wall or pors from drying coated articles and finishing material resi- floor/ceiling assembly, that has a fire-resis- due to be exhausted. Spraying equipment shall be tance-rating of not less than 1 hour, provided interlocked with the ventilation of the spraying area such the spray booth can be adequately maintained that spraying operations cannot be conducted unless the and cleaned. ventilation system is in operation. 2. This requirement shall not prohibit locating a 1504.2.2 Recirculation.Air exhausted from spraying oper- spray booth closer than 3 feet(914 mm) to an ations shall not be recirculated. exterior wall or a roof assembly provided the Exceptions: wall or roof is constructed of noncombustible 1. Air exhausted from spraying operations is allowed material and provided the spray booth can be to be recirculated as makeup air for unmanned adequately maintained and cleaned. spray operations provided that: 1504.1.2.6 Size.The aggregate area of spray booths in a 1.1. The solid particulate has been removed. building shall not exceed the lesser of 10 percent of the 1.2. The vapor concentration is less than 25 area of any floor of a building or the basic area allowed percent of the LFL. for a Group H-2 occupancy without area increases,as set forth in the Building Code of New York State. 1.3. Approved equipment is used to monitor the The area of an individual spray booth in a building vapor concentration. shall not exceed the lesser of the aggregate size limit or 1.4. When the vapor concentration exceeds 25 1,500 square feet(139 m2). percent of the LFL,the following shall oc- cur: Exception: One individual booth not exceeding 500 a. An alarm shall sound; and square feet(46 m2). 1504.1.3 Spraying spaces. Spraying spaces shall be de- b. Spray operations shall automaticallyshut down. signed and constructed in accordance with the Building Code of New York State and Sections 1504.1.3.1, 1504.2, 1.5. In the event of shutdown of the vapor con- 1504.3, 1504.4, 1504.5 and 1504.6 of this code. centration monitor, 100 percent of the air volume specified in Section 1504.2 is auto- 1504.1.3.1 Floor. Combustible floor construction in matically exhausted. spraying spaces shall be covered by approved,non com- 2. Air exhausted from spraying operations is allowed bustible, nonsparking material,except where combusti- to be recirculated as makeup air to manned spray- ble coverings,such as thin paper or plastic and strippable ing operations where all of the conditions provided coatings are utilized over noncombustible materials to in Exception 1 are included in the installation and facilitate cleaning operations in spraying spaces. documents have been prepared to show that the in- 1504.1.4 Limited spraying spaces. Limited spraying stallation does not pose a life safety hazard to per- spaces shall comply with Sections 1504.1.4.1 through sonnel inside the spray booth,spray space or spray 1504.1.4.4. room. 1504.1.4.1 Job size. The aggregate surface area to be 1504.2.3 Air velocity. Ventilation systems shall be de- sprayed shall not exceed 9 square feet(0.84 m2). signed, installed and maintained such that the average air 1504.1.4.2 Frequency.Spraying operations shall not be velocity over the open face of the booth,or booth cross sec- of a continuous nature. tional in the direction of airflow during spraying operations, shall not be less than 100 feet per minute(0.51 m/s). 1504.1.4.3 Ventilation.Positive mechanical ventilation 1504.2.4 Ventilation obstruction. Articles being sprayed providing a minimum of six complete air changes per shall be positioned in a manner that does not obstruct collec- hour shall be installed. Such system shall meet the re- tion of overspray. quirements of this code for handling flammable vapors. Explosion venting is not required. 1504.2.5 Independent ducts. Each spray booth and spray room shall have an independent exhaust duct system dis- 1504.1.4.4 Electrical wiring. Electrical wiring within charging to the outside. 10 feet (3048 mm) of the floor and 20 feet(6096 mm) horizontally of the limited spraying space shall be de- Exceptions: signed for Class I, Division 2 locations in accordance 1. Multiple spray booths havin a combined frontal with the Chapter 27 of the Building Code of New York area of 18 square feet(1.67 in )or less are allowed State. to have a common exhaust when identical 146 FIRE CODE OF NEW YORK STATE FLAMMABLE FINISHES spray-finishing material is used in each booth. If 1504.3.4 Filter rolls. Spray booths equipped with a filter more than one fan serves one booth, fans shall be roll that is automatically advanced when the air velocity is interconnected such that all fans operate simulta- reduced to less than 100 feet per minute(0.51 m/s)shall be neously. arranged to shut down the spraying operation if the filter roll 2. Where treatment of exhaust is necessary for air fails to advance automatically. pollution control or for energy conservation,ducts 1504.3.5 Filter disposal.Discarded filter pads shall be im- shall be allowed to be manifolded if all of the fol- mediately removed to a safe,detached location or placed in lowing conditions are met: a noncombustible container with a tight-fitting lid and dis- 2.1.The sprayed materials used are compatible posed of properly. and will not react or cause ignition of the 1504.3.6 Spontaneous ignition.Spray booths using dry fil- residue in the ducts. ters shall not be used for spraying materials that are highly 2.2. Nitrocellulose-based finishing material susceptible to spontaneous heating and ignition. Filters shall not be used. shall be changed prior to spraying materials that could react 2.3. A filtering system shall be provided to re- with other materials previously collected.Examples of po- duce the amount of overspray carried into tentially reactive combinations include lacquer when com- the duct manifold. bined with varnishes,stains or primers. 2.4. Automatic sprinkler protection shall be 1504.3.7 Waterwash spray booths. Waterwash spray provided at the junction of each booth ex- booths shall be of an approved design so as to prevent exces- haust with the manifold,in addition to the sive accumulation of deposits in ducts and residue at duct protection required by this chapter. outlets. Such booths shall be arranged so that air and overspray are drawn through a continuously flowing water 1504.2.6 Termination point.The termination point for ex- curtain before entering an exhaust duct to the building exte- haust ducts discharging to the atmosphere shall not be less rior. than the following distances: 1504.4 Different coatings. Spray booths, spray rooms and 1. Ducts conveying explosive or flammable vapors, spray spaces shall not be alternately utilized for different types fumes or dusts:30 feet(9144 mm)from the property of coating materials where the combination of materials is con- line; 10 feet(3048 mm)from openings into the build- ducive to spontaneous ignition,unless all deposits of one mate- ing;6 feet(1829 mm)from exterior walls and roofs; rial are removed from the booth, room or space and exhaust 30 feet(9144 mm) from combustible walls or open- ducts prior to spraying with a different material. ings into the building which are in the direction of the exhaust discharge; 10 feet(3048 mm)above adjoin- 1504.5 Illumination.Where spraying spaces,spray rooms or ing grade. spray booths are illuminated through glass panels or other 2. Other product-conveying outlets: 10 feet(3048 mm) transparent materials,only fixed lighting units shall be utilized from the property line;3 feet(914 mm)from exterior as a source of illumination. walls and roofs; 10 feet (3048 mm) from openings 1504.5.1 Glass panels.Panels for light fixtures or for obser- into the building; 10 feet(3048 mm)above adjoining vation shall be of heat-treated glass, wired glass or ham- grade. mered-wire glass and shall be sealed to confine vapors, 3. Environmental air duct exhaust:3 feet(914 mm)from mists,residues,dusts and deposits to the spraying area.Pan- the property line;3 feet(914 mm)from openings into els for light fixtures shall be separated from the fixture to the building. prevent the surface temperature of the panel from exceeding 1504.2.7 Fan motors and belts.Electric motors driving ex- 200°F(93°C). haust fans shall not be placed inside booths or ducts.Fan ro- 1504.5.2 Exterior fixtures. Light fixtures attached to the tating elements shall be nonferrous or nonsparking or the walls or ceilings of a spraying area,but which are outside of casing shall consist of,or be lined with,such material.Belts any classified area and are separated from the spraying area shall not enter the duct or booth unless the belt and pulley by vapor-tight glass panels,shall be suitable for use in ordi- within the duct are tightly enclosed. nary hazard locations.Such fixtures shall be serviced from 1504.3 Filters.Air intake filters that are part of a wall or ceiling outside the spraying area. assembly shall be listed as Class I or Class II in accordance with 1504.5.3 Integral fixtures.Light fixtures that are an inte- UL 900.Exhaust filters shall be required. gral part of the walls or ceiling of a spraying area are al- 1504.3.1 Supports.Supports and holders for filters shall be lowed to be separated from the spraying area by glass panels constructed of noncombustible materials. that are an integral part of the fixture.Such fixtures shall be listed for use in Class 1,Division 2 or Class 11,Division 2 lo- 1504.3.2 Attachment.Overspray collection filters shall be cations, whichever is applicable,and also shall be suitable readily removable and accessible for cleaning or replace- for accumulations of deposits of combustible residues.Such ment. fixtures are allowed to be serviced from inside the spraying 1504.3.3 Maintaining air velocity.Visible gauges,audible area. alarms or pressure-activated devices shall be installed to in- 1504.5.4 Portable electric lamps.Portable electric lamps dicate or ensure that the required air velocity is maintained. shall not be used in spraying areas during spraying opera- FIRE CODE OF NEW YORK STATE 147 FLAMMABLE FINISHES tions. Portable electric lamps used during cleaning or re- accordance with Section 1504.2.2,the heating system shall pairing operations shall be of a type approved for hazardous not be within the recirculation air path. locations. 1504.7.2.1 Interlocks. The spraying apparatus, drying 1504.6 Fire protection.Spray booths and spray rooms shall be apparatus and ventilating system for the spray booth or protected by an approved automatic fire-extinguishing system spray room shall be equipped with interlocks arranged complying with Chapter 9 which shall also protect exhaust ple- to: nums,exhaust ducts and both sides of dry filters when such fil- ters are used. 1. Prevent operation of spraying apparatus while dry- ing operations are in progress. 1504.6.1 Protection of sprinklers. Automatic sprinklers 2. Purge spray vapors from the spray booth or spray installed in spraying areas shall be protected from accumu- room for a period of not less than 3 minutes before lation of residue from spraying operations in an approved drying apparatus is rendered operable. manner. Bags used as a protective covering shall be 0.003-inch-thick(0.076 mm)polyethylene or cellophane or 3. Have the ventilating system maintain a safe atmo- shall be thin paper. Automatic sprinklers contaminated by sphere within the spray booth or spray room during overspray particles shall be replaced with new automatic the drying process and automatically shut off dry- sprinklers. ing apparatus in the event of a failure of the venti- lating system. 1504.6.2 Automated spray application operations. 4. Shut off the drying apparatus automatically if the Where protecting automated spray application operations, air temperature within the booth exceeds 200°F automatic fire-extinguishing systems shall be equipped (93°C). with an approved interlock feature that will,upon discharge of the system,automatically stop the operation of spraying 1504.7.2.2 Portable infrared apparatus.When porta- operations and workpiece conveyors into and out of the ble infrared drying apparatus is used, electrical wiring spraying area. Where the building is equipped with a fire and portable infrared drying equipment shall comply alarm system,discharge of the automatic fire-extinguishing with the Chapter 27 of the Building Code of New York system shall also activate the building alarm notification ap- State.Electrical equipment located within 18 inches(457 pliances. mm)of floor level shall be approved for Class I,Division 2 hazardous locations.Metallic parts of drying apparatus 1504.6.2.1 Alarm station. A manual fire alarm and shall be electrically bonded and grounded.During spray- emergency system shutdown station shall be installed to ing operations, portable drying apparatus and electrical serve each spraying area. When activated, the station connections and wiring thereto shall not be located shall accomplish the functions indicated in Section within spray booths, spray rooms or other areas where 1504.6.2.At least one such station shall be readily acces- spray residue would be deposited thereon. sible to operating personnel.Where access to this station is likely to involve exposure to danger,an additional sta- 1504.7.2.3 Sources of ignition. Except as specifically tion shall be located adjacent to an exit from the area. provided in this section,drying or baking units utilizing a 1504.6.3 Ventilation interlock prohibited. Air makeup heating system having open flames or which are capable and spraying area exhaust systems shall not be interlocked of producing sparks, shall not be installed in a spraying with the fire alarm system and shall remain in operation dur- area. ing a fire alarm condition. Exception:Where the type of fire-extinguishing system SECTION 1505 used requires that ventilation be discontinued, air DIPPING OPERATIONS makeup and exhaust systems shall shut down and damp- ers shall close. 1505.1 Location of dip-tank operations.Dip-tank operations conducted in buildings used for Group A, I or R occupancies 1504.6.4 Fire extinguishers. Portable fire extinguishers shall be located in a room designed for that purpose,equipped complying with Section 906 shall be provided for spraying with an approved automatic sprinkler system, and separated areas in accordance with the requirements for an extra vertically and horizontally from other areas in accordance with (high)hazard occupancy. the Building Code of New York State. 1504.7 Drying operations. Spray booths and spray rooms 1505.2 Ventilation of vapor areas.Vapor areas shall be pro- shall not be alternately used for the purpose of drying by ar- vided with mechanical ventilation adequate to prevent the dan- rangements which could cause an increase in the surface tem- gerous accumulation of vapors. Required ventilation systems perature of the spray booth or spray room except in accordance shall be arranged such that the failure of any ventilating fan with Sections 1504.7.1 through 1504.7.2.3. shall automatically stop the dipping conveyor system. 1504.7.1 Spraying procedure. The spraying procedure 1505.3 Construction of dip tanks. Dip tanks shall be con- shall use low-volume spray application. structed in accordance with this section and NFPA 34. Dip 1504.7.2 Drying apparatus. Fixed drying apparatus shall tanks, including drain boards, shall be constructed of comply with this chapter and the applicable provisions of noncombustible material and their supports shall be of heavy Chapter 21. When recirculation ventilation is provided in metal,reinforced concrete or masonry. 148 FIRE CODE OF NEW YORK STATE LoopNet- 384 tray xoaa, rree ;�,ianaing tsiog, yueensoury, iv x 1 ar k -2Z17 Previous Image 1 of 3 Next Print Window Close Window a� e� k aJ� `a e� r ga C. J MO'!N OF OUEENSI iRY RIMI I PIPAR 1 MENT To download this image: BaSed On OJr limited examination, compliance with our comments shall 1. Right click on the image with your mouse not be con;#rued as indicating the 2. Click "Save Picture As" plans and b�,ClilCatiORS are in full � �� 3. Select where you want to save the photo COmPllance with the Building Codes of 4. Specify a file name New York State. 5. Click "Save" jr httD://www.loopnet.com/xNet/MainSite/Listing/Profile/ProfileImage.aspx?LID=1483 3143&STID=&Ind... 11/21/2007 MaxD raft 440 28' 1 x 14*4 IW w x 91 6"h � i LLJ LrJ { x GEM TOOL M. " JOE EMANUELE 2332 ROUTE 9W SAUGERTIES,NY 12477 PHONE 845-336-2666 FAX 845-336-4172 1-800.486-2299 JOE'S CELL: 1-846-464-9190 E-MAIL GEMTOOL@HVC.RR.COM MaAUFB11440 MMISi010 Maxdraft z � Intake IntakeC 0 010 j Unit Unit 1'-6 14'-41/2" 1'-6". Y-Tv 16'-0 -- II 22'411/2" 24'-0" Side Elevation Front Elevation 6%1" Ev' 1'-6" T-S" 1'-6" �o 4 4 Co -- N Q O r+ N 14'-4 1/2" T_ Side Air Make Up 14'-4 lr2" - Rear Air F take Up Plan View '� .. _= .10E EMANUELE SAIMA of North America,Inc.reserves the right to modify or change any of 1 f 2332 ROUTE 9W 4AUGERTIES,NY 12477 PHONE 84336-2666 FAX US-336-4172 1-800-486-2299 ,,OE%CELL: 1-846-464-9190 E-MAIL GEMTOOL@HVC.RR.COM Maxdra#t t60 Code Compliance &Technical Specifications Burner Demands Each Booth will require: 1. Burner Rating: 1,200,000 Btu/hr 1. Level Floor+l-1/8" 2. Fuel Pressure: 7"-12"of water column 2. Allow for adequate space around the booth for @1,000 CF/hr cleaning and maintenance,in accordance with NFPA(National Fire Protection Association)33, 3. Fuel: Natural Gas 2000 ed.,Section 3.3. 4. Combustion Efficiency: 100% 3. Provide for unobstructed explosion relief in accordance with NFPA 86,95 Ed. 5. Temperature set point accuracy: +/ .5°F 4. Allow for adequate clearance of 3'minimum from 6. Electrical Power: 110v all sparking electrical components,to conform to NFPA 33,2000 ad,,Section 4-3.4. Electrical Demands 5. Means of egress to conform to NFPA 101,94 Ed. 1. Motors: (1) 7.5 H.P. 208/240 v 25 amps 3Phase 6. An approved automatic fire extinguishing system and shall be provided by others. (1) 3 H.P. 208/240 v 12 amps 3Phase 7. Overall Height of Booth: 1019" Overall Width of Cabin: 14'4" 2. Light (2)110 v 20 amps Overall Width of Booth: 19'6" Overall Length of Booth: 24' 3. All electrical connections should be in accordance with NEC(National Electrical Code). 8. Air Velocity: Verify compliance to local codes within the Intake Fan: 10,000 cfm jurisdiction of the installation site. Exhaust fan: 10,000 cfm Air Demands 9. Air changes per minute: 4 to 5 (During Spray Cycle) 1. Max 40 psi to the air regulator 10, R"irculation 80%/20% 2. Piping dimension to the bake cycle!illumination (During Bake Cycle) cut of solenoid valve:1!2" ETL Listings: Based on-107 Outside Temperature 1. Booth: 518416 1. Inside Temperature during Spray Cycle: +75`F 2. Burner: 530022 2. Inside Temperature during Bake Cycle: +172'F 3. Lighting: J20036157-003 Control Panel MEA Listing: 1. Panel may be placed at one's discretion and not 1. Booth: 363-91-E to be within 3'of the booth opening. The placement shall comply with all local and national NYC Calendar: codes. 1. Booth: 41832 GEMjZsr - JOE MANUELE 2332 ROUTE 9W SAO*d No*ameriM Inc,961 Route 10 East,Suite 2k;Randolph,New Je SAUCEOTIES, NY"12477 PHONE 845-336-2666 FAX 845-336-4172 1-MO 486-2299 JOE'S CELL: 1-845,464_9190 — E-MAIL GEMTOOL@HVC.RR.COM t t Maxdraft 440 Booth Specifications Cabin Features Air Make Up Features Dimensions: Intake: • 13'wide x 23'8"long x Thigh ID Vinyl Coated White Externally to match • 13'5"wide x 24'long x 10'9"high OD The cabin • Optional 2'and 4'Length Extensions 10.000 cfm • 7.5 HP 3 Phase TEFC motor Exhaust Configurations: 1.000,000 Btu(capable)stainless steel Burner with 30:1 cum down,for accurate • Side Down Exhaust Modulation • Recirculating damper 30`ao/50% Construction: Incoming and recirculation Pre Filtration • Totaliv enclosed mechanical for safety Single Skin 18 Ga.steel walls Burner pre-installed.pre-wired..and • Vinyl coated White Externally,White Internally Electronically tested • Reinforced Ceiling Frame beams for rigidity ETL Listed • Powder Coated White.Ceiling Filter Grates for Dustless Performance Command Panel: Main Doors: PLC-Programmable Logic Control • Fully automatic operation controls • 36"wide x 3'9"high Paint,Flash Off,Bake.Cooling cycles,and • 3 of the swing out type.2"thick with glass Temperatures standard with Heating System Hung by adjustable hinges to a box steel frame Digital readout,programmable temperature For durability controller with auto tuning(AT)for maximum • Side Service Door temperature control,standard with Heating • 36"wide x 7 6"high with glass system • On/Off Switch Filters: Spray Switch • Bake Switch • 3-Pre-Filters 17.75"x 23.5"x 20" Lights Switch • 12-Pre cut(10 micron)ceiling filters Burner On/Off Switch,standard with heating compression sealed to knife ceiling frame edge system 44"x 46" • 2-25"wide x 16 long Fiberglass Exhaust Filter Exhaust: (Side Exhaust) • 10,000 cfm to match intake Lights: (2)24"Tubeaxil Fans(Side Down) • (2)2 HP 3 Phase TEFC motor(Side Down) • Daylight Corrected Light Bulbs • 12 Upper Gable Fixtures with 4 lamps each Note: • =Lower Vertical Foul Lamp Fixtures,optional • SAIMA USA reserves the right to modify or Optima: change any of the dimensions or features without notification. • Indirect Fired Heating System • Single Phase Electronics,(7.5 HP) Warranty: • Drive Through • One year on all moving and electrical parts • Three years on Structure of Cabin , i JOE EMANUELE 2332 ROUTE 9W i SAUGERTIES, NY 12477 PHONE 845-336-2666 FAX 845-336-4172 1-800-486-2299 JOE'S CELL: 1-845-464-9190 E-MAIL GEMTOOL@HVC.RR.COM g rwr 973A2-WS