Loading...
2008-269 TOVN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building &Codes (518) 761-8256 CERTIFICATE OF OCCUPANCY Permit Number. P20080269 Date Issued: Monday, January 25, 2010 This is to certify that work requested to be done as shown by Pen-nit Number P20080269 has been completed. Location: 31 COTTAGE HILL Rd Tax Map Number. 523400-301-008-0002-022-000-0000 Owner. LAWRENCE & LINDA KUTCHER Applicant: LAWRENCE & LINDA KUTCHER This structure may be occupied as a: Residential Addition By Order of Town Board TOWN OF QUEENSBURY Issuance of this Certificate of Occupancy DOES NOT relieve the property owner of the responsibility for compliance with Site Plan, 1` G Variance, or other issues and conditions as a result of approvals by the Director of Building L&Code Enforces meet Planning Board or Zoning Board of Appeals. TOWN OF QUEENSBURY 742 Bay Road,Queensbury,NY 12804-5902 (518)761-8201 Community Development- Building&Codes (518) 761-8256 BUILDING PERMIT Permit Number: P20080269 Application Number. A20080269 Tax Map No: 523400-301-008-0002-022-000-0000 Permission is hereby granted to: LAWRENCE & LINDA KUTCHER For property located at: 31 COTTAGE HILL Rd in the Town of Queensbury,to construct or place at the above location in accordance with application together with plot plans and other information hereto filed and approved and in compliance with the NYS Uniform Building Codes and the Queensbury Zoning Ordinance. Type of Construction Value Owner Address: LAWRENCE & LINDA KUTCHER 31 COTTAGE HILL Rd Residential Addition $4,100.00 QUEENSBURY, NY 12804-0000 Total value $4,100.00 Contractor or Builder's Name/Address Electrical Inspection Agency TIATRO & SONS NY 12804-0000 Plans &Specifications 2008-269 100 sq ft residential addition $75.00 PERMIT FEE PAID- THIS PERMIT EXPIRES: Friday,June 12, 2009 (If a longerperiod is required,an application loran extension must be made to the code Enforcement Officer of the Town of Queensbury before the expiration date.) Dated at the To of ens a June 12, 2008 SIGNED BY for the Town of Queensbury. Director of Building&Code Enforcement .. ....... .................................. ----.. 01.................... —2 _ OFFICE USE ONLY ; TAX MAP No,.-' PERMIT No. ; FEES: P T E E TION ENGINEERING ; (If applicable) ; ................... .... . ......................... 1..................... IT PRINCIPAL STRUCTURE APPLICATION FOR ZONING APPROVAL & BUILDING PERMIT A PERMIT MUST BE OBTAINED BEFORE BEGINNING CONSTRUCTION.APPLICATION IS SUBJECT TO REVIEW BEFORE ISSUANCE OF A VALID PERMIT FOR CONSTRUCTION. J� APPLICANT/BUILDER: ifc{iro S OWNER: II ADDRESS: I&.e /:• u"n4 u r ADDRESS: eOfk r,e h I PHONE NOS. 3z 1 ` ou / PHONE NOS. /4�9<�­ CONTACT PERSON FOR BUILDING&CODES COMPLIANCE: A A -75­ty PHONE: Z/-V-O LOCATION OF PROPERTY: C�r l `�' l r /C C� Gc i, SUBDIVISION NAME: PLEASE INDICATE MEASUREMENTS AS REQUIRED BELOW: CHECK ALL THAT 0 o APPLY TO YOUR zO 1= LO 0 U) cQn CO w PROJECT �- 0 tz O w -' a = _ W -j LL Q C9 U Z Q Q - f/) N (A 0 x06 SINGLE FAMILY / TWO-FAMILY / MULTI-FAMILY (NO.of UNITS) TOWNHOUSE BUSINESS OFFICE RETAIL- MERCANTILE FACTORY OR INDUSTRIAL ATTACHED GARAGE(1,2,3) OTHER �� /0 IF COMMERCIAL OR INDUSTRIAL-NAME OF BUSINESS: N� ESTIMATED CONSTRUCTION COST: FUEL TYPE: NIA HEAT TYPE: *HOW MANY FIREPLACE(S): ! �AAND/OR WOODSTOVES(S): /9 ZONING CATEGORY: ARE THERE WETLANDS ON THIS SITE? NU IS THIS A HISTORIC SITE? /Ud PROPOSED USE OF BUILDING OR ADDITION: L&w_&d r!2 R,q oz,_gd,,e.�� *Please complete a separate Application for"Fuel Burning Appliances&Chimneys"available in our office B 3-LGL 11-05 Town of Queensbury- Community Development Office - 742 Bay Road, Queensbury, NY 12804 ARE THERE STRUCTURES NOT SHOWN ON PLOT PLAN? ARE THERE EASEMENTS ON PROPERTY? I acknowledge no construction activities shall be commenced prior to issuance of a valid permit. I certify that the application, plans, and supporting materials are a true and complete statement/description of the work proposed, that all work will be performed in accordance with the NY State Building Codes, local building laws and ordinances, and in conformance with local zoning regulations. I acknowledge that prior to occupying the facilities proposed, I or my agents will obtain a certificate of occupancy. I also understand th a are required to provide an as-built survey by a licensed land surveyor of all newly tructed facilities prior to issuance of a certificate of occupancy. I have read and agree to the above. r Signed r Director of Building &Codes: 761-8256 (for questions regarding Building Permits, construction codes or septic systems) Zoning Administrator: 761-8218 (for questions regarding required permits, the permit process, application requirements or to schedule an appointment) Permission is hereby granted to the above ; This application / proposed action described Applicant to erect or alter the building herein is found to be in accordance with the described herein in accordance with said zoning Laws of the Town of Queensbury. Application: 0 0 ,0 WILAX16 & ODEAPPROVAL ZONING APPROVAL q DATE + + QUESTIONS? CALL 7614256 OR EMAIL codes@gueensburv.net VISIT OUR WEBSITE FOR MORE INFORMATION WWW.pueens ury.net :" Town of Queensbury• Community Development Office - 742 Bay Road, Queensbury, NY 12804 ��_tu_s Queensbu Bu' ding Code i-nYorcement - Residential Final In a IonrY gs� i ice No. (518) 761-8256 Arrive: m/P. �,m-/-pm4Q Date Inspection request received: inspector's Initials: k�© NAME: C4 MIT#: LOCATION: .�L itTE: Z TYPE OF STRUCTUR _ Comments: N N/A 4` Builds Number Address visible from road o 6 -/Z � ChimneyHeight l"B°Vent/Direct Vent Location Fresh Air Intake 3 inch Plumbing Vent through roof minimum 6 inches Roof Complete/Exterior Finish Complete Platform at all exterior doors Handrail 4 or more risers Guards at stairs decks tios more than 30 inches above grade Guard at stairwell at 34 inches or more Guard at deck porches 36 inches or more Handrail Termination at Newell Post or Wail Interior/Exterior Railings 34 inches to 38 inches Deck Bracing/Handicapped Ramp Compliant Grade away from foundation 6 inches with 10 feet 6 inch clearance to silt plate _ Gas Valve shut-off exposed/regulator 18 inches above grade Interior privacy/trim/doors/main entrance 36 inches Bathroom/Kitchen watertight Safety laz' I Window in stairwells safety glazing Interior Smoke Detectors/Carbon Monoxide Detectors Every level: Every Bedroom: Outside every bedroom area: inter Connected: Batte backup: Attic access 30 inches x 22 inches x 30 inches(height)in accessible area Crawl Spaces 18 inch x 24 inch access 1 N.ft.-150 sq.ft.vents Bathroom Fans,if no window Plumbing fixtures Foundation insulation/insulation Certification Floor truss,draft sto iEg finished basement 1,000 sq.ft. Emergency ress below n!e Gas Furnace shut-off within 30 feet or within line of site Oil Furnace shut-off at entrance to furnace area Fumace/Hot Water Heater operating Low water shut-off boiler Relief Valves installed/Heat Trap/Water Temp 110 Enclosed Stairs Sheetrock Underside minimum'A'Gypsum Basement stairs closed rise>4 inches Garage Floor Pitched Garage fireproofing/%hour fire door/door closer Duct work Seated properly Gas Logs in Sealed or Glass Enclosure Final Electrical Ir Final Survey Plot Plan Arc Fault Breaker in Bedrooms Flex Gas Pipe Bondingt- As Built Septic System/Sewer Dept. Inspection Sticker Site Plan /Variance required Flood Plain Certification,if required V- Okay to issue C I C or C 10 1 Tem r ' /Permanent L:\Building&Codes Forms\Building&Codes\Inspection Forms\Residential Final Inspection Form revised 100405.doc;Revised January 7,2008;Revised 6/26/08 � rH Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Ins p on request received: Queensbury Building &Code Enforcement Arrive: am/pj e part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspector's Initials: NAME: �� 1���P, PERMIT #: t 9 — wR, LOCATION: ,� � C r, P� ('E 01 u INSPECT ON: t I - 1 TYPE OF STRUCTURE: Y N NIA Rough Plumbing /Nail Plates Ll Plumbing Vent/Vents in Place K4 -rkau jet- 1 % inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test Water Supply Piping Air/Head 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 COMMONWEALTH ELECTRICAL INSPECTION SERVICE,INC. Main Office 176 Doe Run Road-Manheim,PA 17545 MUNICIPAL CERTIFICATE - ELECTRICAL APPROVAL Permit N r. .......Cert. N2 3816Cut-in Card No..................................... Owner....................L&A.Ay, ......14.vn.�,Aax.......................................................................................... Location...........3A....... Installation Consisting of..... . ...........)....................... . ............. ..-5.�'j ...3...R(;,-r,w.-)...... ......................................................I............................................................................. .................................................................................................................................................................................... InstalledBy...........-5.A.rn.0...........................................................Lic.No................................................... The conditions following governed the issuance of this certificate,and any certificate previously issued is cancelled:- This certificate only covers the electrical equipment and installation conditions as of date. Upon the introduction of additional equipment or alterations,application shall be promptly made for inspection. Inspectors of this Company shall have the privilege of making inspections at any time, and if its rules are violated,the Company shall have the right to revoke this certificate. Date........... --'i.............. INSPECTOR ......................................... Member N.F.P.A.,I.A.E.I. -Rough Plumbing / 1 su ation Insp iion Report Office No. (518) 761-8256 Date Inspecoon r Queensbury Building &Code Enforcement Arrive: "ILV p art: _a- 742 Bay Road, Queensbury, NY 12804 Inspector's ln' al NAME: V P R T #: LOCATION: IN ECT ON: 1 0 TYPE OF STRUCTURE: Y N NIA Ro h Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 Y k inch minimum Drain Size .Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes ��-� Pressure Test Water Supply Piping `r1 /Head (30C ►2 000 50 P.S.I for 15 minutes Insulation/Residential Check/Commercial Check T ek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 iFi� I /e.�e) Rough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspection request received: Queensbury Building & Code Enforcement Arrive: 0.A o, am/pm _ Depart: am/pm 742 Bay Road, Queensbury, NY 12804 Ins or's Initials: RJ -'-. NAME: v� C� PERMIT #: LOCATION: INSPECT ON: l J TYPE OF STRUCTURE: Y N N/A Rough Plumbing Nail Plates Plumbing Vent Vents in Place 1 1/2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet change of direction Pressure Test Drain / Vent Air / Head 5 P.S.I. or 10 ft. above highest connection for 15 minutes Pressure Test WaW Supply Piping 06 / Head 50 P.S.I for 15 minutes Insulation Residential Check Commercial Check Proper Vent Attic Vent Duct/ Hot Water Piping Insulation If required unheated spaces Combustion Air Supply for Furnace Duct work sealed properly / No duct tape COMMENTS: LAPam Whiting\Building&CodesUnspection Forms\Rough Plumbing insulation Report.revised Nov 17 2003.doc Revised February 15,2005 -411ough Plumbing / Insulation Inspection Report Office No. (518) 761-8256 Date Inspectio quest received: Queensbury Building & Code Enforcement Arrive: i art: am/ m P P 742 Bay Road, Queensbury, NY 12804 ins s Initials• NAME: PERMIT * LOCATION: INSPECT ON: TYPE OF STRUCTURE: Y N NIA Rough Plumbing/Nail Plates Plumbing Vent/Vents in Place 1 Y2 inch minimum Drain Size Washing Machine Drain 2 inch minimum Cleanout every 100 feet/change of direction Pressure Test Drain /Vent Air/Head 5 P.S.I. or 10 ft. above hi hest connection for 15 minutes Pressure Test C t Water Supply Piping Air/Head for 15 minutes 1� f sulati -Residential Check/Commercial Check Tyvek or Similar Exterior Sealant Proper Vent, Attic Vent Door/Window Sealed No Insulation Duct/Hot Water Piping Insulations If required unheated spaces Combustion Air Supply for Furnace Duct work sealed property/No duct tape COMMENTS: Rough Plumbing Insulation Report.revised Nov 17 2003, revised February 15,2005, revised January 7,2008 Framing / Firestopping Inspection R port Office No. (518) 761-8256 Date Ins Iv Queensbury Building&Code Enforcement Arrive: 742 Bay Road, Queensbury, NY 12804 Inspector's Init' NAME: _ � - � � PERMIT#: LOCATI INSPECT ON: TYPE OF STRUCTURE: Y N NIA COMMENTS: Framing i ccess 22" x 30" minimum Jack Studs/Headers Bracing/Bridging Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12"O.C. Headroom 6 ft. 8 in. Stair ells 36 in. or more Exterior Deck Bracing Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/ w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side%inch or 5/8 inch Type X Garage side 5/8 inch Type X Ceiling/wall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. OM 5.7 sf above/below grade 5.0 s#grade LABuilding&Codes Forms-01-13U3uilding&CodesUnspecxan FaeisU=raming Firestopping Inspection ReporLdoc Revised January 7,2008 Framing / Firestopping Inspection R4ort Office No. (518)761-8256 Date In e u sire Queensbury Building &Code Enforcement Arrive: part: am/pm 742 Bay Road, Queensbury, NY 12804 Inspecto s I Itia ` V Ot5-2 YO le-,r-- I .f , 0 // NAME: PERMIT# LOCATION: INSPECT ON: TYPE OF STRUCTURE: Framing Y N WA COMMENTS: -AftIc ccess 22" x 30" minimum Jack Studs/HeadersC�� Bracing/Bridging \LA�, Joist hangers Jack Posts/Main Beams Exterior sheeting nailed properly 12" O.C. Headroom 6 ft. 8 in. Stairwells 36 in. or more Exterior Deck Bracing cJ Headroom 6 ft. 8 in. Notches/Holes/Bearing Walls Metal Strapping for Notches Top Plate 1 '/ w 16 gauge 8 16D nails each side Draft stopping 1,000 sq. ft. floor trusses Anchor Bolts 6 ft. or less on center Ice and water shield 24 inches from wall Fire separation 1, 2, 3 hour Fire wall 2, 3, 4 hour Firestopping Penetration sealed 16 inch insulation in cavity min. Garage Fire Separation House side %inch or 518 inch Type X Garage side 5/8 inch Type X Ceilingfwall Windows Habitable Space/Bedrooms 24 in. (H) 20 in. (W) 5.7 sf above/below grade 5.0 sf grade LABuilding&Codes Fortes-QLD1Building&Codesllnsimbon FomulFmffwig FnstoW g Inspection Report.doc Revised January 7,2008 -`d .40 Foundation Inspection Report Office No.(518)761-8256 Date Inspection req st r /- ed�' Queensbury Building&Code Enforcement Arrive: Depart: �m 742 Bay Rd.,Queensbury,NY 12804 Inspector's Initi NAME: fft)tAcc" T#: OF—2 LOCATION: ECT ON: TYPE OF STRUCTURE: Z � 1 � Comments Y N N/A t t jFootinPgs otSo vR,� Lz' Vi\L Monolithic Slab Reinforcement in Place The contractor is responsible for providing protection from freezing t for 48 hours following the placement V—N55ARI of the concrete. Materials for this purpose on site. Foundation/Wallpour Reinforcement in Place Footing Dowels or Keyway in place Foundation Dampproofmg Foundation Waterproofing Footing Drain Daylight or Sump Footing Drain Stone: 12 inch width 6 inches above footing 6 mil poly for wet areas under slab Backfill Approval Plumbing Under Slab C/Cast/Copper ZFoundation Insulation Interior/Exterior R_ u Rough Grade 6 inch drop within 10 ft. L:\Building&Codes Forms\Building&Codes\Inspecction Forms\Foundation Inspection Report.doc Last printed 12/20/2005 9:24:00 AM Community Development Office Town of Queensbury • 742 Bay Rd. !� s Queensbury, New York •12-$04 PLOT PLAN Show all existing a%proposed structures. Indicate the setbacks of all structures and buildings from all property lines. '' SIDE PROPERTY LINE <5 TI zt- N Z of 0 O W ` 7,11 Z /\/ f �3 a'3 kw. V n ( 17 N1 01 1 SQUARE = FT. SIDE PROPERTY LINE ` `''`° i f� V gal 2 .1 �I�UZ��O ��• ' (J� -yLt ti 7 �,c�esf C,vc� UMY U� i/ ��/son /dDSIiCZ -P Ste Community Development Office own of Queensbury - 742 Bay Road - Queensbury, New York •12804 Marilyn Ryba, Executive Director• David Hatin, Director of Building&Codes Craig Brown,Zoning Administrator WINDOW SCHEDULE - ' JOB SITE/ADDRESS: 31 Co� DATE: OWNER: APPLICATION NO.: WINDOW- UNIT OR CLEAR CLEAR WINDOW STOCK ROUGH ROUGH SQ.FT. OPENING NO.OR WINDOW SQ.FT. OPENING SPECIAL HARDWARE OR VENT MANUFACTURER NUMBER OPENING OPENING EGRESS/CLEAR HEIGHT LETTER NAME MODEL/TYPE CALL WIDTH HEIGHT VE OPENING WIDTH IN IN INSTRUCTIONS ON PLAN SIZE INCHES INCHES Community Development Office ; own of Queensbury ■ 742 Bay Road - Queensbury, New York -12804 0 Marilyn Ryba,Executive Director- David Hatin, Director of Building&Codes 0 Craig Brown,Zoning Administrator BUILDING PERMIT CALCULATION SHEET: NATURAL LIGHT, VENTILATION AND EMERGENCY EGRESS REQUIREMENTS AREA OF ROOM IN ACTUAL LIGHT REQUIRED ACTUAL SQUARE FOOT HABITABLE ROOM SQUARE FEET SQUARE FOOTAGE VENTILATION-4% VENTILATION OPENING FOR REMARKS OF ROOM AREA SQUARE FOOTAGE EGRESS tAAAAi"7 !oo �D- QUESTIONS? CALL 761-8256 OR EMAIL 10c codesCalaueensburv.net jJ 10 14 VISIT OUR WEBSITE FOR MORE INFORMATION www.auensburV.net 4