air balance report • cc_ - o2:1Lk -Zoe° Serving the Greater Construction Industry in the Testing and Balancing of Air and Fluid Systems SEP092019 Adirondack TOWN OF QUEENSBURY Ar BUILDING& CODES Bal ance „ R Co Inc. 11^` • • A _ 1!. :et, 4A. . .. Py 0j v. • n ' 1 'i.t �i iN, L• d pkf, w'' 342 Clendon Brook Road Queensbury, New York 12804 Phone (518) 798-6186 Fax .. (518) 792-4052 • "Providing experience and knowledge for the mechanical systems of 2000 and beyond': Adirondack Air Balance Co., Inc. Test and Balance Reports Project: Glens Falls National Bank Address: 221 Corinth Rd. Queensbury,New York 12804 • Contractor: Hilltop Construction Co. Address: 51 Crowley Rd,Hudson Falls, New York 12839 Certification: The systems herein have been tested and balanced to within tolerances specified in the plans and specifications or to within the limitations of the equipment installed.All the Testing and Balancing has been performed in accordance with The Associated Air Balance Council and The National Environmental Balancing Bureau.The results of those tests are recorded herein. Date:8/24/2019 By: ! Q.i IV\PAiy John C. Merry TESTING"AND BALANCING AGENCY: ADIRONDACK AIR BALANCE CO.,INC. INSTRUMENT LIST For John C.Merry • Instrument Manufacturer Model# Calibration Range Serial# Date Capture Hood Shortridge ADM 860 2/12/2019 0-2000 CFM M65580 Air Data Shortridge ADM 2/19/2019 50-8000 FPM M08668 Multimeter 860C Thermal TSI AVM430 2/22/2019 0-6,000 FPM AVM430916003 Anemometer Incline Dwyer 400 Not Required 0-12,000FPM Not Manometer 0-10" Required Magnehelics Dwyer 2002C Not Required 0-2.5" Not 2008 0-8" Required Sling Taylor 1330 Not Required 32-100F Not Psychrometer Required PocketThermo- Taylor TA16903 Not Required -40-180F Not • meter Required Water Meter Alnor HM680 3/14/2018 0-300 PSI 70651020 HVAC Clamp Fluke 902 2/19/2019 0-600V 18400123 Meter 0-600A _ Tachometer Shimpo DT-207L 4/1/2019 0-90,000 RPM D56B0073 Vesting and Balancing.Agency: Date: 8/24/2019 Adirondack Air Balance Co.,Inc. Page: 1 of 2 Project# 3337 Project Name: Glens Fall.National Bank Address: 209 Corinth Rd. Queensbury,New York AIR MOVING EQUIPMENT TEST SHEET SYSTEM F-1 Equipment Location MER Area Served Entire Space Equipment Manufacturer York Model Number TG9S060B Serial Number W1D8744930 . • Specified Actual Specified Actual Total CFM-Fan 1000 NA Total CFM-Outlet 1303 988 R/A CFM o NS 888 O/A CFM NS 100 Total Static Pressure(Total/Ext.) .50 Ext. .20 Ext. Inlet Pressure NS 0.12 Discharge Pressure NS 0.08 Fan RPM NS High Specified Actual Specified Actual. Motor Manufacturer NS NA Motor HP 1 BHP NS NA Phase single single Voltage 120 120 Amperage NA 5.9 Motor RPM NS • 3 Speed Motor Service Factor NS 1.0. Starter Heater Elements NS TP Motor.Sheave&No. Grooves • Direct Drive Fan Sheave&No. Grooves • Belts Remarks:. Tenting and Balancing Agency: Date: 8/24/2019 Adirondack Air Balance Co..Inc. Page: 2 of 2 Project#: 3337 Project Name:.Glens Falls National Bank Address: 209 Corinth Rd. Queensbury,New York AIR DISTRIBUTION TEST SHEET Terminal Room Terminal Design Test-FPM or CFM Final Number Number Type Size Factor FPM CFM Test I Test 2 Test 3 FPM CFM F-1 1 108 CD 6"rd. 1.0 Hood 33 Del. Del.. NR Hood Del.. 2 107 CD 7"rd. 1.0 Hood 117 115 70 NR Hood 70 3 104 CD 6"rd. 1.0 Hood 17 82 20 NR Hood 20 4 109 CD 8"rd. 1.0 Hood 137 46 120 NR Hood 120 5 103 CD 8"rd. 1.0 Hood 163 99 100 NR Hood 100 6 110 CD 6"rd. 1.0 Hood 89 72 75 NR Hood 75 7 102 CD 6"rd. 1.0 Hood 207 135 90 NR Hood 90 8 111 CD 6"rd. 1.0 Hood 90 76 75 NR Hood 75 9 101 CD 6"rd. 1.0 Hood 150 52 128 NR Hood 128 10 100 CD 6"rd. 1.0 Hood 150 141 151 NR Flood 151 11 100 CD 6"rd. 1.0 Hood 150 147 159 NR Flood 159 1303 988 HX-1 Supply 1 MER OD 6"rd. .20 NS NS 0 500 NR 500 100 Exhaust 1 MER OD 6"rd. .20 NS NS 0 535 NR 535 107 EF-1 1 104 ER 12x12 1.0 Hood NS 55 NR NR Hood 55