blower door resultsDate:
City: LAKE LUZERNE State: NY Zip: 12846
Phone #518-361-7364 Email:
City: Queensbury State: NY Zip: 12804
Phone # 518-798-9244 Email:
Square Footage:3486
Volume =
Blower Door Diagnostics: Ring
Inside Temp: 70 Baseline Pressure -50 Pa.A
Outside Temp: 80 Fan Pressure 89 Pa.B
C 8
761 cfm@50
New York State Requires builders run a blower door test on new residential
buildings to ensure a maximum air leakage of three air changes per hour (ach50).
*ACH test results are considerably lower than building standards. Mechanical
Ventilation is highly recommended.
Blower Door testing performed by:
Jack Hall Plumbing & Heating, Inc.
165 Bay St
Glens Falls, NY 12801
518-792-7114
ID: 1015618
BLOWER DOOR TEST FORM
Contractor Address: 26 SQUIRE CIRCLE
Location tested: 155 Assembly Point Rd
Customer Name:
KH@QUALITYBUILDERS.COM
Ventilation requirements:
Building has a HRV installed.YES NO
7/19/2019Contractor: QUALITY BUILDERS
Maximum CFM 50 to achieve less than 3 ACH = 1427
Volume: 28550 x 3 = 85650 /60 = 1427CFM @ 50
CFM@50 X 60 / VOLUME = 1.57 ACH
Open
Actual Flow @ CFM50 =
(Height x Living) + (Height x Basement) X 3 / 60 = ACH per Hour