Loading...
GM1916696_000_6_09-05-19REPORT OF CONCRETE CYLINDER TEST Whitestone Associates Licensee Address Report Date: 10/16/19 Project Number: GM1916696.000 Report Number: 6 Project: Aldi Supermarket Client: Aldi Inc. Address: 708 Upper Glen Street Queensbury NY Attn: FIELD TEST CONDITIONS AND RESULTS (ASTM C 31) Date Placed: 9/5/2019 Time Sampled: Location of Sample: Sidewalk - Cart corral and main entrance Supplier: Pallette Truck Number: 4905 Ticket Number: 4454 Mix Number: 40008 Time Placed: 11:50 am Design Strength: 4000 Time Batched: 11:06 am Batch Size: 5.0 Slump: 5.0 (ASTM C 143)Air Content: 6.2 (ASTM C 173) Concrete Temp: 70 F (ASTM C 1064)Ambient Temp: 75 F Water Added: Technician: SB Initial Curing: Final Curing: Max Field Curing Temp.: Min Field Curing Temp.: LABORATORY TEST RESULTS (ASTM C 39) Specimen 733 734 735 736 737 738 Test Date 9/12/2019 9/12/2019 10/3/2019 10/3/2019 10/3/2019 Age 7 7 28 28 28 Load 55190 60300 67950 73440 68530 Diameter 4.00 4.00 4.00 4.00 4.00 4.00 Area 12.57 12.57 12.57 12.57 12.57 12.57 Strength 4390 4800 5410 5840 5450 Percent of Design 110% 120% 135% 146% 136% Type of Fracture Remarks: Copies to: Reported by: Tyler Ulrich Concrete Laboratory Supervisor Type 1 Type 2 Type 3 TYPES OF FRACTURE Type 4 Type 5 Type 6