Loading...
GM1916696_000_7_08-02-19REPORT OF CONCRETE CYLINDER TEST Whitestone Associates Licensee Address Report Date: 10/16/19 Project Number: GM1916696.000 Report Number: 7 Project: Aldi Supermarket Client: Aldi Inc. Address: 708 Upper Glen Street Queensbury NY Attn: FIELD TEST CONDITIONS AND RESULTS (ASTM C 31) Date Placed: 8/2/2019 Time Sampled: Location of Sample: Foundation Wall Supplier: Pallette Truck Number: 4902 Ticket Number: 3541 Mix Number: 40000 Time Placed: 12:3 pm Design Strength: 4000 Time Batched: 12:03 pm Batch Size: 9.0 Slump: 5.0 (ASTM C 143)Air Content: 5.9 (ASTM C 173) Concrete Temp: 80 F (ASTM C 1064)Ambient Temp: 75 F Water Added: Technician: SB Initial Curing: Final Curing: Max Field Curing Temp.: Min Field Curing Temp.: LABORATORY TEST RESULTS (ASTM C 39) Specimen 649 650 651 652 653 654 Test Date 8/9/2019 8/9/2019 8/30/2019 8/30/2019 8/30/2019 Age 7 7 28 28 28 Load 52770 48920 67100 69150 67980 Diameter 4.00 4.00 4.00 4.00 4.00 Area 12.57 12.57 12.57 12.57 12.57 Strength 4200 3890 5340 5500 5410 Percent of Design 105% 97% 134% 138% 135% Type of Fracture 1 1 1 1 1 Remarks: Copies to: Reported by: Tyler Ulrich Concrete Laboratory Supervisor Type 1 Type 2 Type 3 TYPES OF FRACTURE Type 4 Type 5 Type 6