Loading...
GM1916696_000_9_07-19-19REPORT OF CONCRETE CYLINDER TEST Whitestone Associates Licensee Address Report Date: 10/16/19 Project Number: GM1916696.000 Report Number: 9 Project: Aldi Supermarket Client: Aldi Inc. Address: 708 Upper Glen Street Queensbury NY Attn: FIELD TEST CONDITIONS AND RESULTS (ASTM C 31) Date Placed: 7/19/2019 Time Sampled: Location of Sample: Interior Floor Slab infills Supplier: Pallette Truck Number: 4913 Ticket Number: 088 Mix Number: 40019 Time Placed: 8:00 am Design Strength: 4000 Time Batched: 7:40 am Batch Size: 11.0 Slump: 7.0 (ASTM C 143)Air Content: 1.2 (ASTM C 173) Concrete Temp: 78 F (ASTM C 1064)Ambient Temp: 73 F Water Added: Technician: JV Initial Curing: Final Curing: Max Field Curing Temp.: Min Field Curing Temp.: LABORATORY TEST RESULTS (ASTM C 39) Specimen 621 622 623 624 625 626 Test Date 7/26/2019 7/26/2019 8/16/2019 8/16/2019 8/16/2019 Age 7 7 28 28 28 Load 53380 47960 52620 62870 60990 Diameter 4.00 4.00 4.00 4.00 4.00 Area 12.57 12.57 12.57 12.57 12.57 Strength 4250 3820 4190 5000 4850 Percent of Design 106% 96% 105% 125% 121% Type of Fracture Remarks: Copies to: Reported by: Tyler Ulrich Concrete Laboratory Supervisor Type 1 Type 2 Type 3 TYPES OF FRACTURE Type 4 Type 5 Type 6