GM1916696_000_3_08-07-19REPORT OF CONCRETE CYLINDER TEST Whitestone Associates Licensee Address Report Date: 10/16/19 Project Number: GM1916696.000 Report Number: 3 Project: Aldi Supermarket Client: Aldi Inc. Address: 708 Upper Glen Street Queensbury NY Attn: FIELD TEST CONDITIONS AND RESULTS (ASTM C 31) Date Placed: 8/7/2019 Time Sampled: Location of Sample: Cart Corral, Stem Wall and Foundation Wall Supplier: Pallette Truck Number: 4904 Ticket Number: 3669 Mix Number: 40001 Time Placed: 3:15 pm Design Strength: 4000 Time Batched: 3:00 pm Batch Size: 6.5 Slump: 4.0 (ASTM C 143)Air Content: 7.2 (ASTM C 173) Concrete Temp: 80 (ASTM C 1064)Ambient Temp: 82 Water Added: Technician: SB Initial Curing: Final Curing: Max Field Curing Temp.: Min Field Curing Temp.: LABORATORY TEST RESULTS (ASTM C 39) Specimen 655 656 657 658 659 660 Test Date 8/14/2019 8/14/2019 9/4/2019 9/4/2019 9/4/2019 Age 7 7 28 28 28 Load 54930 46230 60260 64000 65070 Diameter 4.00 4.00 4.00 4.00 4.00 4.00 Area 12.57 12.57 12.57 12.57 12.57 12.57 Strength 4370 3680 4800 5090 5180 Percent of Design 109% 92% 120% 127% 130% Type of Fracture Remarks: Copies to: Reported by: Tyler Ulrich Concrete Laboratory Supervisor Type 1 Type 2 Type 3 TYPES OF FRACTURE Type 4 Type 5 Type 6