ResCheck gGenerated by REScheck-Web Software i, Compliance Certificate Project McCoslin Residence 5ECEIVErn) Energy Code: 2015 IECC Location: Warren County, New York fI� DEC 0 4 2018 Construction Type: Single-family Ll Project Type: Alteration Climate Zone: 6 (8499 HDD) TOWN OF QUEENSBURY Permit Date: COMMUNITY DEVELOPMENT Permit Number: Construction Site: Owner/Agent: Designer/Contractor: 65 Rockhurst Road Mary McCoslin AND:Architecture&Design Queensbury, New York 12804 46 Brown's Path mark@and-architecture.com Queensbury, NY 12804 ompliance Passes using prescriptive requirements for alteration projects Envelope Assemblies Gross Area Cavity Cont. Assembly or U-Factor UA Perimeter R-Value R-Value Ceiling:Cathedral Ceiling(no attic) --- --- --- --- --- Exemption: Framing cavity filled with insulation Wall: Wood Frame, 16"o.c. --- --- --- --- --- Exemption: Framing cavity filled with insulation Basement:Masonry Block w/Empty Cells 592 21.0 0.0 0.048 28 Wall height:8.0' Depth below grade: 5.0' Insulation depth:8.0' Window:Wood Frame 170 0.270 46 Door:Solid Door(under 50%glazing) 18 0.270 5 Door: Glass Door(over 50%glazing) 146 0.280 41 Compliance Statement: The proposed building design described here is consistent with the building plans,specifications,and other calculations submitted with the permit application.The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version: REScheck-Web and to comply with the m tory-requirements lied in the REScheck Inspection Checklist. Name-Title ' - • ` ` ° Signature ,p-t.0 /i le Date %&' \1NONY o' 41 227.13-2-30 RC-0764-2018 , .}` -i • McCoslin, Mary -t�' y tit Ar - 65 Rockhurst Rd ci;,, ¢- Residential Alterations 832 s.f. ii3 O.&:i0 Project Title: McCoslin Residence Report date: 11/30/18 Data filename: Page 1 of 9 e. REScheck Software Versions REScheck-Web Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified Complies? Comments/As5umptiotts # Pre-Inspection/Ptah Review Value - Value &RegID 103.1, :Construction drawings and iOComplies 103.2 documentation demonstrate ODoes Not [PR1]1 energy code compliance for the ;[]Not Observable building envelope.Thermal lC7Not Applicable :envelope represented on construction documents. 103.1, ;Construction drawings and OComplies 103.2, ;documentation demonstrate Does Not 403.7 ;energy code compliance for ONot Observable (PR3P ;lighting and mechanical systems. :Not Applicable Systems serving multiple :dwelling units must demonstrate Icompliance with the IECC !Commercial Provisions. 302.1, ;Heating and cooling equipment is i Heating: Heating: ;DComplies 403.7 sized per ACCA Manual S based Btu/hr , Btu/hr ;ODoes Not [PR212 on loads calculated per ACCA Cooling: Cooling: ;ONot Observable ,: Manual j or other methods Btu/hr Btu/hr ONot Applicable ;approved by the code official. Additional Comments/Assumptions: 1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McCoslin Residence Report date: 11/30/18 Data filename: Page 2 of 9 Section Plans Verified Field Verified ) # Foundation Inspection Complies? Comments/Assumptions & Re ID. Value Value Req.ID 'Conditioned basement wall R- R- ;DComplies See the Envelope Assemblies [F04]1 :insulation R-value.Where interior R- R- DDoes Not table for values. 9) insulation is used,verification ; Not Observable may need to occur during !Insulation Inspection. Not DNot Applicable ;required in warm-humid locations; in Climate Zone 3. 303.2 ;Conditioned basement wall DComplies [F0511 :insulation installed per ❑Does Not 4, ;manufacturer's instructions. :Not Observable i - DNot Applicable 402.2.9 ;Conditioned basement wall ft ft lElComplies See the Envelope Assemblies [F06)1 ;insulation depth of burial or - "ODoes Not 'table for values. ;distance from top of wall. ONot Observable ONot Applicable 303.2.1 A protective covering is installed <DComplies [FO1l]2 ':to protect exposed exterior ODoes Not insulation and extends a -DNot Observable -;,minimum of 6 in. below grade. DNot Applicable 403.9 ;Snow-and ice-melting system • `.DComplies [F012]2 controls installed. DDoes Not DNot Observable ONot Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) 1 Project Title: McCoslin Residence Report date: 11/30/18 Data filename: Page 3 of 9 Section Plans Verified field Verified # Framing/Rough-In inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, ,Door U-factor. U- U- '❑Complies See the Envelope Assemblies 402.3.4 !❑Does Not table for values. (FR1]1 • ;❑Not Observable 9 ;❑Not Applicable 402.1.1, ',Glazing U-factor(area-weighted ; U- U- ❑Complies ;See the Envelope Assemblies 402.3.1, 'average). ❑Does Not table for values. 402.3.3, 402.5 ❑Not Observable [FR2]1 ❑Not Applicable 303.1.3 ;U-factors of fenestration products: '.❑Complies [FR4]1 :are determined in accordance ❑Does Not with the NFRC test procedure or ❑Not Observable ;taken from the default table. I❑Not Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ':❑Does Not instructions. ❑Not Observable Not Applicable 402.4.3 ;Fenestration that is not site built ❑Complies [FR2O]1 :is listed and labeled as meeting : .❑Does Not J AAMA/WDMA/CSA 101/I.S.2/A440, ,or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable 'limits. 402.4.5 'IC-rated recessed lighting fixtures - ❑Compiles [FR16]2 ,sealed at housing/interior finish '❑Does Not and labeled to indicate s2.0 cfm leakage at 75 Pa. `❑Not Observable ❑Not Applicable 403.3.1 ',Supply and return ducts in attics ❑Complies [FR12]1 insulated >= R-8 where duct is ❑Does Not >= 3 inches in diameter and >= R-6 where<3 inches.Supply and- -,❑Not Observable return ducts in other portions of ':❑Not Applicable "the building insulated>= R-6 for 'diameter>=3 inches and R-4.2 for< 3 inches in diameter. 403.3.5 :Building cavities are not used as !❑Complies [FR15)3 ducts or plenums. ❑Does Not -'❑Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ;❑Complies [FR17]2 above 105°F or chilled fluids i❑Does Not below 55°F are insulated to>R- 3, :DNot Observable ;DNot Applicable 403.4.1 Protection of insulation on HVAC ❑Complies [FR24]1 piping. ❑Does Not 4 ;❑Not Observable ❑Not Applicable 4035.3 Hot water pipes are insulated to , R- R- :❑Complies [FR18]2 R-3. ❑Does Not ❑Not Observable ❑Not Applicable 403.6 Automatic or gravity dampers are. ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1'High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McCoslin Residence Report date: 11/30/18 Data filename: ?aae 4 of 9 Section Plans Verified Field Verified Complies? Comments/Assumptions # Insulation Inspection Value Value & Req.tD 303.1 All installed insulation is labeled '[Complies [IN1312 or the installed R-values ❑Does Not 'provided. ;[Not Observable `� i[Not Applicable 402.1.1, `Wall insulation R-value. If this is a. R- R- [Complies :See the Envelope Assemblies 402.2.5, �mass wall with at least'/z of the 0 Wood ❑ Wood Does Not table for values. 402.2.6 wall insulation on the wall [ Mass 0 Mass [Not Observable :. [IN3)1 ':exterior,the exterior insulation 0 Steel 0 Steel ,[Not Applicable requirement applies(FR10). 303.2 Wall insulation is installed per DComplies [IN4I1 manufacturer's instructions. [Does Not ;[Not Observable I DNot Applicable Additional Comments/Assumptions: 1 IHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McCoslin Residence Report date: 11/30/18 Data filename: Page 6 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions &Regal 402.1.1, ;Ceiling insulation R-value. R- R- '❑Complies See the Envelope Assemblies 402.2.1, ❑ Wood 0 Wood ❑Does Not table for values. 402.2.2, Steel 402.2.E ❑ ❑ Steel ;❑Not Observable [FI1]1 ❑Not Applicable 303.1.1.1„Ceiling insulation installed per "r `❑Complies 303.2 :manufacturer's instructions. : - '❑Does Not [FI2]1 !Blown insulation marked every 300 ft2. '❑Not Observable ❑Not Applicable 402 2 3 ',Vented attics with air permeable , ; ,- ❑Complies [FI22]2 insulation include baffle adjacent €:'. ❑Does Not ;to soffit and eave vents that : extends over insulation. t';_ ❑Not Observable ❑Not Applicable 402.2.4 ;Attic access hatch and door R- R- ;❑Complies [FI3]1 ;insulation e_R-value of the ;❑Does Not ;adjacent assembly. ❑Not Observable ONot Applicable 402.4.1.2 :Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = ;❑Complies [FI17]1 ach in Climate Zones 1-2,and ODoes Not <=3 ach in Climate Zones 3-8. ONot Observable ❑Not Applicable 403.3.4 ;Duct tightness test result of<=4 cfm/100 cfm/100 '❑Complies [Fi4]1 cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable handler @ 25 Pa. For rough-in tests,verification may need to ❑Not Applicable ;occur during Framing Inspection. 403.3.3 •Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [FI27]1 :determine air leakage with ft2 ft2 ❑Does Not either: Rough-in test:Total leakage measured with a ❑Not Observable pressure differential of 0.1 inch ;❑Not Applicable w.g.across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total ;leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air 'handler enclosure. 403.3.2.1 ;Air handler leakage designated IDComplies [F124]1 by manufacturer at<=2%of ;❑Does Not design air flow. [Not Observable ❑Not Applicable 403.1.1 Programmable thermostats ❑Complies [FI9]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 .Heat pump thermostat installed ❑Complies [FI10]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [Fill]2 systems have automatic or EDoes Not accessible manual controls. ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: McCoslin Residence Report date: 11/30/18 Data filename: Page 7 of 9 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions &Req.ID 403.6.1 All mechanical ventilation system ❑Complies [F125)2 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy ❑Not Observable and air flow limits. ❑Not Applicable 403.2 .Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating I,C3Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor `❑Not Applicable temperature. • 403.5.1.1 Heated water circulation systems : ❑Complies (F128]2 :have a circulation pump.The ❑Does Not ;system return pipe is a dedicated ❑Not Observable return pipe or a cold water supply ;pipe. Gravity and thermos- ❑Not Applicable ,syphon circulation systems are I not present.Controls for .circulating hot water system - pumps start the pump with signal ;for hot water demand within the :occupancy.Controls automatically turn off the pump when water is in circulation loop ;is at set-point temperature and no demand for hot water exists. 403.5.1.2 'Electric heat trace systems '❑Complies [F129]2 comply with IEEE 515.1 or UL }❑Does Not 515.Controls automatically Not Observable adjust the energy input to the ❑ heat tracing to maintain the Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that • ❑Complies [F130]2. have recirculation pumps that ElDoes.Not pump water from a heated water :supply pipe back to the heated "' ;❑Not Observable water source through a cold Not Applicable water supply pipe have a ',demand recirculation water system. Pumps have controls 'that manage operation of the pump and limit the temperature of the water entering the cold :water piping to 1044F. 403.5.4 Drain water heat recovery units ❑Complies (Fi31] 'tested In accordance with C5A B55.1.Potable water-side Does Not pressure loss of drain water heat -❑Not Observable recovery units <3 psi for '❑Not Applicable individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units< 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ;OComplles [FI6]1 !fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ❑Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [FI23]3 'no continuous pilot light. =❑Does Not ❑Not Observable ❑Not Applicable 1 [High Impact(Tier 1) 12 [Medium Impact(Tier 2) 13 [Low Impact(Tier 3) I Project Title: McCoslin Residence Report date: 11/30/18 Data filename: ?age 8 of 9 Section # Final Inspection Provisions Plans Verified Field Verified (& Req.ID Value Value Complies? Comments/Assumptions 1401.3 Compliance certificate posted. 1F17J2 _Complies DDoes Not :Not Observable [7Not Applicable 303.3 Manufacturer manuals for [FI1813 mechanical and water heating DComplies ;systems have been provided. Does Not []Not Observable ENot Applicable Additional Comments/Assumptions: 1(High Impact(Tier 1) 12 I Medium Impact(Tier 2) 13 I Low Impact(Tier 3) 1 Project Title: McCoslin Residence Report date: 11/30/18 Data filename: Page 9 of 9 2 Energy,Ejte Eff15IECC ici ency Certificate Insulation Rating R-Value Above-Grade Wall 0.00 Below-Grade Wall 21.00 Floor 0.00 Ceiling / Roof 0.00 Ductwork (unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.27 Door 0.28 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments