HVAC calculator EMS Calculator Page 1 of 14 pECEOWE EMS HVAC Load Calculator DEC o 7 2018 www.hvacloadcalculator.com TOWN OF OUEENSBURY BUILDING&CODES Date: Fri Dec 7 Loaded Document: gf info - 2018 09:39am Company Info Client Information Company GF HEATING OIL LLC Name Mary McCoslin Preparer BRIAN NELSON Addressl 65 ROCKHURST RD QUEEN Phone (518) 792-2220 Address2 Email brian@gfheatingoil.com Address3 Phone (321) 231-4597 Email Date 07-Dec-2018 This HVAC load calculation has been performed using sound engineering principles as prescribed by Manual J eighth edition and ASHRAE Handbook of Fundamentals. Duct sizing has been performed as prescribed by Manual D. 1. Design Conditions(Temp. F) Check If Using Celcius INDOOR OUTDOOR TEMP Front of West DIFF Building is Facing WINTER 70 -20 90 Total 1400 Sq.Ft SUMMER 65 90 25 Conditioned Area https://ems-residential.hvacloadcalculator.com/app/ 12/7/2018 EMS Calculator Page 3 of 14 Distance of OH from top of 1.6 1.6 1.6 1.6 window (A) Length of overhang (B) 1.6 1.6 1.6 1.6 Total linear ft. across top 4 7 0 0 of windows located below overhang Solar GainThrough Glass Check this box if using manufacturer specifications and enter the latitude, U-value and SHGC Latitude 45 U-Value SHGC Facing Area(sq ft) Type Glass HTM Unshaded Shaded BTUH North or 51 Double v 24.00 0 51 1,224 Shaded NE/NW 0 v 0.00 0 0 0 South 45 Double v 40.00 45 0 1,800 SE/SW 0 v 0.00 0 0 0 East 19 Double v 75.00 19 0 1,425 West 200 Double v 75.00 200 0 15,000 Does glass have reflective Yes v 0.6 11,669 coating? Skylight 0 Clear v 150 0 Total 11,669 Solar Gain https://ems-residential.hvacloadcalculator.com/app/ 12/7/2018 EMS Calculator Page 6 of 14 * CAUTION - The cooling capacity of the air conditioner must meet both, sensible and latent loads. It is recommended a Manual S calculation be performed. Using manufacturer's specs. The nominal tons assume .75 S/T ratio at the chosen outdoor design temperature. Summary Including Basement Heating Load Sensible Cooling Latent Cooling Total Cooling Load Nominal Tons 39,870 19,342 3,101 22,442 2.04 Whole House (Block Load) Completed Scroll to top For Additional Options Solar Gain Through Glass .m�Check if Using Manufacturer specs Latitude 40 U-Value SHGC Facing Area(sq ft) Type Glass HTM BTUH North or 0 Double 24.00 0 Shaded NE/NW 0 \, 0.00 0 South 0 Single ' 50.00 0 SE/SW 0 v 0.00 0 East 0 V 0.00 0 West 70 Tripl or Low-I v 65.00 4,550 Does glass have reflective coating? Yes v 2,730 https://ems-residential.hvacloadcalculator.com/app/ 12/7/2018 EMS Calculator Page 8 of 14 Basement Summary Heating Load Sensible Cooling Latent Cooling Total Cooling Load *Nominal Tons 7,377 3,789 851 4,141 0.40 * CAUTION - The cooling capacity of the air conditioner must meet both, sensible and latent loads. It is recommended a Manual S calculation be performed. Using manufacturer's specs. The nominal tons assume .75 S/T ratio at the chosen outdoor design temperature. Room by Room Load Calculation Total House Total House System CFM Cooling Heating Heat Loss Sensible Heat 1200 800 Gain 39,870 19,342 ♦Add Room Room HeatLoss HeatGain CFM_Heat CFM_Cool Name :iCheck-Calculations-When-Completed auto- 7,377 3,789 148 235 basement Totals: 7,377 3,789 148 235 Percent Of Original: 18% 19% IRound to Rectangle Conversion Calculator(Optional) Enter Round Side A (Inches) Side B (Inches) Diameter 0 0 https://ems-residential.hvacloadcalculator.com/app/ 12/7/2018 EMS Calculator Page 10 of 14 4th reduction or branch 0 5th reduction or branch 0 Basement supply and return 148 trunk Room Runs cfm no of outlet duct air outlets cfm dia vel auto-basement 0 0 Duct Sizing Completed Scroll to top For Additional Options -► Equipment selection as per Manual S Instructions: enter load, weather and manufacture's data in white cells Auto Complete BTUH Total Heat Loss 39870 Design Outdoor Indoor Conditions Total Heat Gain 21942 -20 70 Sensible Heat 19342 90 65 Gain Latent Heat Gain 2,601 ID Design RH 50%, 63F WB Sensible/Total 0.88 Altitude 344 Ratio target clg Temp. 17 Predominantly Heating climat v Drop Manufactures Equipment Specifications https://ems-residential.hvacloadcalculator.com/app/ 12/7/2018 EMS Calculator Page 11 of 14 Equipment Manufacturer Model BTUH Total Sensible Latent No output cooling BTUH BTUH (heating) BTUH ® OD design temp Furnace RUUD R9 60000 r2.,gCt��0bDi31-1 YY15A Boiler 0 0 Heat Pump RUUD RA 24000 24000 0 or Air Conditioner SQ.1\13)-4 1 it A Evaporator RUUD RC at-i(`lST/ayy)c-is Coil Air Handler Total 59174.4 23876.16 23876.16 0 Capacity with Altitude Correction Selected OVERSIZED OK OK UNDERSIZED Equipment Size Heating CFM Cooling CFM External Static Pressure of (recommended) Blower 1200 1,277 0 Available static presure for Supplemental heat needed for heat duct system pump Blower ext. 0 HP capacity @ 47F 0 static press Coil press HP capacity @ 17F 0 0 drop* https://ems-residential.hvacloadcalculator.com/app/ 12/7/2018 EMS Calculator Page 12 of 14 Filter press 0 HP capacity ® 0 drop* ODDT Register press 0 BTUH 39,870 drop supplemental heat Grille Pressure 0 KW supplemental 12 Drop heat Other 0 Other 0 Other 0 Available SP 0 for duct Equipment Size Limits Air conditioner- Furnace Boiler heat Pump Cool Climate Heat output output Climate Maximum Size 25,234 27,428 55,818 55,818 Selected OK OK OVERSIZED OVERSIZED Size Energy Cost Analysis Heat Loss 39,869.91 Heating Degree Days 7000 Heat Gain 21,942.44 Cooling Degree Days 500 Summer Design 90 Summer Design Temp 25 Temp Diff https://ems-residential.hvacloadcalculator.com/app/ 12/7/2018