Loading...
ComCheck COMcheck Software Version 4.0.8.1 3 cc 3 • Interior Lighting Compliance Certificatect) a . Project Information7:3 CA 12 I co t� Energy Code: 90.1 (2013)Standard DEC 2 8 2018 l� ta< Project Title: Walmart Store#4403 '� C n Project Type: Alteration O WN` --q----- n BU!ii;,;OF� E�tSuU�Y O ul Construction Site: Owner/Agent: Designer/Contractor: ;�"" N C) 24 quaker Ridge Blvd -P W Queensbury, NY 12804 to O Allowed Interior Lighting Power H co A B C Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Breakroom(Common Space Types:Lounge/Breakroom) 856 0.73 625 2-Rear Mens Restroom(Common Space Types:Restrooms) 245 0.98 240 3-Rear Womens Restroom(Common Space Types:Restrooms) 310 0.98 304 4-Mothers Room(Common Space Types:Restrooms) 113 0.98 111 5-Front Mens Restroom(Common Space Types:Restrooms) 246 0.98 241 6-Front Womens Restroom(Common Space Types:Restrooms) 321 0.98 315 7-Grocery Sales(Retail:Sales Area) 23060 1.44 33206 8-Deli(Common Space Types:Food Preparation) 972 1.21 1176 9-Health Services(Healthcare Facility:Pharmacy) 50 1.68 84 10-Receiving(Common Space Types:Storage) 11342 0.63 7145 11-Bakery(Common Space Types:Food Preparation) 540 1.21 653 12-Bakery Sales(Common Space Types:Food Preparation) 1600 1.21 1936 13-Site-to-Store Storage(Common Space Types:Storage) 1011 0.63 637 14-Rear Office Hallway(Common Space Types:Storage) 1517 0.63 956 Total Allowed Watts= 47629 Proposed Interior Lighting Power A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Waft. Breakroom(Common Space Types:Lounge/Breakroom 856 so.ft.) LED 1: 10:2'X4'LED Troffer:Other: 1 19 30 570 Rear Mens Restroom(Common Space Types:Restrooms 245 sq.ft.) LED 2:existing:Circular Recessed Downlight:Other: 1 10 12 120 LED 3:65:2'Vanity Light:Other: 1 3 21 63 Rear Womens Restroom(Common Space Types:Restrooms 310 sq.ft.) LED 4:existing:Circular Recessed Downlight:Other: 1 14 12 168 LED 5:65:2'Vanity Light:Other: 1 3 21 63 Mothers Room(Common Space Types:Restrooms 113 sq.ft.) LED 7:68:Circular Recessed Downlight:Other: 1 2 12 24 Front Mens Restroom(Common Space Types:Restrooms 246 sq.ft.1 LED 8:68R:Circular Recessed Downlight:Other: 1 11 12 132 Project Title: Walmart Store#4403 Report date: 12/03/18 Data filename: M:\02\02-19-24403 Queensbury, NY 4403\MEPF\ELEC\ELEC\ComCheck\4403 Queensbury, NY.ct Page 1 of 7 • A B C D E Fixture ID : Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Waft. LED 9:65:2'Vanity Light:Other: 1 4 21 84 Front Womens Restroom(Common Space Types:Restrooms 321 sq.ft.) LED 10:existing:Circular Recessed Downlight:Other: 1 15 12 180 LED 11:65:2'Vanity Light:Other: 1 4 21 84 Grocery Sales(Retail:Sales Area 23060 sq.ft.) Linear Fluorescent 1: Existing:8'Fluorescent Strip:Other:Electronic: 4 187 120 22440 LED 15:34:8'LED Strip:Other: 1 14 53 742 Deli(Common Space Types:Food Preparation 972 sa.ft.) LED 12:7: 1'X4'LED Troffer:Other: 1 9 30 270 LED 13:9:2'X2'LED Troffer:Other: 1 24 32 768 Health Services(Healthcare Facility:Pharmacv 50 soft.) LED 14:9:2'X2'LED Troffer:Other: 1 2 32 64 Receiving(Common Space Types:Storage 11342 sa.ft.) Linear Fluorescent 2:2C:4'Fluorescent Strip:Other:Electronic: 2 2 58 116 Linear Fluorescent 3:Existing:8'Fluorescent Strip:Other:Electronic: 4 44 120 5280 Bakery(Common Space Types:Food Preparation 540 sq.ft.) LED 15:7: 1'X4'LED Troffer:Other: 1 4 30 120 LED 16:9:2'X2'LED Troffer:Other: 1 12 32 384 Bakery Sales(Common Space Types:Food Preparation 1600 sq.ft.) LED 17:7: 1'X4'LED Troffer:Other: 1 9 30 270 LED 18:9:2'X2'LED Troffer:Other: 1 43 32 1376 Site-to-Store Storage(Common Space Types:Storage 1011 sq.ft.) Linear Fluorescent 4:existing:2'X4'Fluorescent Troffer:Other: 2 13 79 1027 Rear Office Hallway(Common Space Types:Storage 1517 sq.ft.) Linear Fluorescent 5:2C:4'Fluorescent Strip:Other:Electronic: 2 2 58 116 Linear Fluorescent 6:Existing:8'Fluorescent Strip:Other:Electronic: 4 11 120 1320 Total Proposed Watts= 35781 nterior Lighting PASSES Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 90.1 (2013)Standard requirements in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory requirements listed in the Inspection Che klist. z t-: c.,0A _ / ('- • • 1)- Name Title Signature —�7i Date a . r �L'"d,7111- _ /1,i � ww � m —.. •i w ?r 092954-1 c. Fo i(cr A R�FESSi0''�' NEW PORK ALTER A T ION WARNING IT IS A VIOLATION O!'NEW YORK REGULATION 7200 FOR ANY PERSON. UNLESS WING UNDER THE DIRECTION OF A LICENSED PROFESSIONAL ENGINEER.TO ALTER AN ITEM IN ANY WAY WI'PiaU'' AFFIXING TO THE ITEM HIS SEAL AND THE NOTIFICATION"ALTERED Er. FOLLOWED BY A SIGNATURE.DATE OF SUCH ALTERATION.AND A SPECIFIC DESCRIPTION OF THE ALTERATION. Project Title: Walmart Store#4403 Report date: 12/03/18 Data filename: M:\02\02-19-24403 Queensbury, NY 4403\MEPF\ELEC\ELEC\ComCheck\4403 Queensbury, NY.cc Page 2 of 7 COMcheck Software Version 4.0.8.1 raft Exterior Lighting Compliance Certificate Project Information Energy Code: 90.1 (2013)Standard Project Title: Walmart Store#4403 Project Type: Alteration Exterior Lighting Zone 2(Residential mixed use area) Construction Site: Owner/Agent: Designer/Contractor: 24 quaker Ridge Blvd Queensbury, NY 12804 Allowed Exterior Lighting Power A B C D E Area/Surface Category Quantity Allowed Tradable Allowed Watts Watts/Unit Wattage (B X C) Total Tradable Watts(a)= 0 Total Allowed Watts= 0 Total Allowed Supplemental Watts(b)= 600 (a)Wattage tradeoffs are only allowed between tradable areas/surfaces. (b)A supplemental allowance equal to 600 watts may be applied toward compliance of both non-tradable and tradable areas/surfaces. Proposed Exterior Lighting Power Exterior Lighting TBD: Invalid exterior use type Project Title: Walmart Store#4403 Report date: 12/03/18 Data filename: M:\02\02-19-24403 Queensbury, NY 4403\MEPF\ELEC\ELEC\ComCheck\4403 Queensbury, NY.cc Page 3 of 7 COMcheck Software Version 4.0.8.1 Inspection Checklist Energy Code: 90.1 (2013) Standard Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. ' Section # Nan Review ; Complies? I Comments/Assumptions &-Req.ID 4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met. 8.4.1.1, calculations provide all information ❑Does Not 8.4.1.2, with which compliance can be 8.7 determined for the electrical systems ❑Not Observable [PR6I2 and equipment and document where ❑Not Applicable 1 exceptions are claimed. Feeder connectors sized in accordance with approved plans and branch circuits 'sized for maximum drop of 3%. 4.2.2, Plans, specifications, and/or ❑Complies Requirement will be met. 9.4.3, 9.7 calculations provide all information ❑Does Not [PR4]1 with which compliance can be ❑Not Observable'. determined for the interior lighting and electrical systems and equipment :ENot Applicable and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts,transformers and control devices. 9.7 Plans, specifications, and/or DComplies [PR8]1 !calculations provide all information LiDoes Not with which compliance can be determined for the exterior lighting Not Observable and electrical systems and equipment ❑Not Applicable and document where exceptions to the standard are claimed. Information provided should include exterior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Walmart Store #4403 Report date: 12/03/18 Data filename: M:\02\02-19-24403 Queensbury, NY 4403\MEPF\ELEC\ELEC\ComCheck\4403 Queensbury, NY.cc Page 4 of 7 section I ,... .. r i �"4,,t $�'� # Rough-in Electrical' Inspection Co n� �' �'„� � Regsl® 8.4.2 At least 50%of all 125 volt 15-and DComplies Requirement will be met. [EL10]2 20-Amp receptacles are controlled by ❑Does Not an automatic control device. ❑Not Observable ❑Not Applicable 9,4.1.1 : Automatic control requirements DComplies Requirement will be met. EL1]2 prescribed in Table 9.6.1,for the ❑Does Not • appropriate space type, are installed. ENot Observable Mandatory lighting controls (labeled as 'REQ') and optional choice controls ❑Not Applicable (labeled as'ADD1' and 'ADD2')are implemented. • 9.4 1.1 ' Independent lighting controls installed DComplies Requirement will be met. EL2]2 per approved lighting plans and all ❑Does Not manual controls readily accessible and! visible to occupants. ❑Not Observable ❑Not Applicable 9.4.1.2 Parking garage lighting is equipped `❑Complies Requirement will be met. [EL11]2 with required lighting controls and !❑Does Not daylight transition zone lighting. "❑Not Observable ❑Not Applicable 9.4.1.1f Daylight areas under skylights and DComplies Requirement will be met. [EL13]1 roof monitors that have more than ❑Does Not 150 W combined input power for general lighting are controlled by ❑Not Observable _ photocontrols. ❑Not Applicable 9.4.1.4 m`.Automatic lighting controls for exterior DComplies [EL3]2 lighting installed. ❑Does Not ❑Not Observable ❑Not Applicable 9.4.1.3 Separate lighting control devices for DComplies Requirement will be met. [EL4]1 specific uses installed per approved ;❑Does Not lighting plans. ❑Not Observable • ❑Not Applicable 9.6.2 Additional interior lighting power '❑Complies Requirement will be met. [EL8]1 allowed for special functions per the ❑Does Not approved lighting plans and is ❑Not Observable automatically controlled and separated from general lighting. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) .2-'Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Walmart Store#4403 Report date: 12/03/18 Data filename: M:\02\02-19-24403 Queensbury, NY 4403\MEPF\ELEC\ELEC\ComCheck\4403 Queensbury, NY.c( Page 5 of 7 z y a` . Section # Final!ospectkin' C pttes' s tit #' . 3zce.s N % _ _ 87,1 Furnished-as-built drawings for ❑Complies Requirement will be met. 1FI1613 electric power systems within 30 days ❑Does Not of system acceptance. DNot Observable ❑Not Applicable 8.7.2 Furnished O&M instructions for ❑Complies Requirement will be met. [E117]3 systems and equipment to the ❑Does Not building owner or designated DNot Observable representative. ❑Not Applicable 9.2.2.3 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [F118]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans, demonstrating proposed watts DNot Observable are less than or equal to allowed _Not Applicable watts. 9.4.2 Exterior lighting power is consistent ❑Complies See the Exterior Lighting fixture schedule for values. [F119]1 with what is shown on the approved ❑Does Not lighting plans, demonstrating proposed watts are less than or equal DNot Observable to allowed watts. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Walmart Store#4403 Report date: 12/03/18 Data filename: M:\02\02-19-24403 Queensbury, NY 4403\MEPF\ELEC\ELEC\ComCheck\4403 Queensbury, NY.cc Page 6 of 7