ResCheck REVIEWED FOR ENERGY CODE COMPLPL1ANCE REScheck Software Version 4.6.1 Compliance Certificate I FILE COPY Project Rhein Residence - Energy Code: 2015 IECC TE0 C E U V Location: Warren County, New York Construction Type: Single-family JUN 2 5 2018 Project Type: New Construction - Conditioned Floor Area: 4,671 ft2 TOWN OF QUEENSBURY Glazing Area 22% BUILDING&CODES Climate Zone: 6 (8499 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: •Chestnut Ridge Road George Rhein Michael Scharff Queensbury, NY 12804 9 Bianca Court Michael J.Scharff,AIA-Architect Warwick, NY 10990 318 Ackertown Road 914-522-2005 Chestnut Ridge, NY 10952 luge101@hotmail.com 646-879-1070 michael@michaelscharff.corn Compliance:Passes using UA trade-off Compliance: 0.0%Better Than Code Maximum UA: 470 Your UA: 470 , The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Ceiling 1: Flat Ceiling or Scissor Truss 4,671 0.0 49.0 0.020 93 Wall 1:Wood Frame, 16"o.c. 1,716 19.0 0.0 0.060 77 Window 1:Wood Frame:Double Pane with Low-E 299 0.300 90 Door 1: Solid 42 1.500 63 Door 2: Glass 86 0.300 26 Floor 1:All-Wood joist/Truss:Over Unconditioned Space 4 671 38.0 0.0 0.026 121 Compliance Statement: The proposed building design described he f is nsis ent w t uilding plans,specifications,and other calculations submitted with the permit application.The proposedbu din (las een�. to meet the 2015 IECC requirements in REScheck Versionn 4.6.1 and to comAply`with the mandatory requ re'ent ist in i ck Inspection Checklist.t .15 1 64 Date 290.-1-22.8 RC-0395-2018 - Rhein, George & Liz = :` �_ 147 Chestnut Ridge Rd. SFD w/gas FP 2741 , Gar. 617 s.f. Project Title: Rhein Residence "°"6''4 e Report date: 05/30/18 Data filename: C:\Users\Authorized User\Documents\Gionta\Rhein\REScheck.rck Page 1 of 9 0 REScheck Software Version 4.6.1 NI Inspection Checklist Energy Code: 2015 IECC Requirements: 100.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement,the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section -, Plans Verified Field Verified Complies?lies.?.: CommentsLAssumptions # Pre-Inspection/Plan Review. Value "Value p &Req.ID - - =- --- , 103.1, Construction drawings and tit'',.'' ❑Complies Requirement will be met. 103.2 ;documentation demonstrate l ' ❑Does Not [PRl]1 'energy code compliance for the ��;' Location on plans/spec: f :building envelope.Thermal �,j ti❑Not Observable This Report ;envelope represented on ' 'P.p., Applicable construction documents. -- -' 103.1, ;Construction drawings and :r-4 ❑Complies Requirement will be met. 103.2, documentation demonstrate ❑Does Not 403.7 ;energy code compliance for Location on plans/spec: ❑Not Observable [PR3]1 :lighting and mechanical systems. Mechanical Notesi:"; ❑Not Applicable Systems serving multiple .�� pP :dwelling units must demonstrate `> . ;compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: ❑Complies Requirement will be met. 403.7 sized per ACCA Manual S based Btu/hr Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Location on plans/spec: Manual) or other methods [Not Observable Mechanical Notes approved by the code official. Btu/hr Btu/hr ❑Not Applicable 1 i Additional Comments/Assumptions: 1 High Impact(Tier 1) a Medium Impact(Tier 2) '3'' Low Impact(Tier 3) Project Title: Rhein Residence Report date: 05/30/18 Data filename: C:\Users\Authorized User\Documents\Gionta\Rhein\REScheck.rck Page 2 of 9 of 2015 IECc Foundation Inspect o Compl es Comments/Assumptions4 303'2'T = A protective covering is installed to ❑Complies Exception: Requirement is not applicable. [FO11)2 protect exposed exterior insulation ❑Does Not and extends a minimum of 6 in. below ❑Not Observable Location on plans/spec: No exposed exterior insulation grade. ❑Not Applicable 403.9LL !Snow-and ice-melting system controls ❑Complies Exception: Requirement is not applicable. [FO12]z _.:installed. ❑Does Not :Not Observable ❑Not Applicable Additional Comments/Assumptions: • • 1 High Impact(Tier 1) 7a Medium Impact(Tier 2) ,?3F:Low Impact(Tier 3) Project Title: Rhein Residence Report date: 05/30/18 Data filename: C:\Users\Authorized User\Documents\Gionta\Rhein\REScheck.rck Page 3 of 9 ,tf Section Plans Verified `"Fie_Id Verified # Framing/Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID - _ 402.1.1, ;Door U-factor. U- U- ❑Complies See the Envelope Assemblies 402.3.4 I ❑Does Not table for values. [FR1]1 i ❑Not Observable ❑Not Applicable 402.1.1, ;Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, :average). ❑Does Not table for values. 402.3.3, 402.3.6, ['Not Observable 402.5 ; ❑Not Applicable [FR2]1 303.1.3 ;U-factors of fenestration products - 0' -, , .`` Complies Requirement will be met. [FR4]1 :are determined in accordance �` •' Z.,� •Does Not ,;:�; with the NFRC test procedure or i ",; f Location on plans/spec: ;taken from the default table. „'■Not Observable Window Schedule q ,� ,: NotApplicable 402.4.1.1 ;Air barrier and thermal barrier , z ❑Complies Requirement will be met. 1 [FR23]1 I installed per manufacturer's <' „ = ❑Does Not instructions. ❑Not Observable Location on plans/spec: u - ❑Not A licable Detailed wall sections 402.4.3 ;Fenestration that is not site built ' ` t€` ❑Complies Requirement will be met. [FR20]1 its listed and labeled as meeting • "� , > ' =:'❑Does Not AAMA/WDMA/CSA 101/1.S.2/A440 -•f �z 4.'e , for has infiltration rates per NFRC , , $44', .t�k ❑Not Observable :400 that do not exceed code ; , ❑Not Applicable :limits. 402.4.5 IC-rated recessed lighting fixtures ' ` '-- ❑Complies Requirement will be met. [FR16)2 sealed at housing/interior finish -4 ' ,, ❑Does Not and labeled to indicate_<2.0 cfm ',4 , Location on plans/spec: '`'ar ❑Not Observable leakage at 75 Pa. Mechanical Notes � CI Not Applicable 403.2.1 ;Supply and return ducts in attics ' .,, ..k a,, ❑Complies Requirement will be met. [FR12]1 ;insulated >= R-8 where duct is_ 4 � ❑Does Not R-6 where<1n diameter and 3 inches.Supply and �, vx,r ' ❑Not Observable Location on plans/spec: Mechanical Notes return ducts in other portions of s1 -0 `l❑Not Applicable :the building insulated>= R-6 for 7 z` -- ;� , diameter>= 3 inches and R-4.2 ,, ;for<3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies Requirement will be met. [FR15]3 ;ducts or plenums. `; ❑Does Not ❑Not Observable Location on plans/spec: Mechanical Notes I ' -s, - ''❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies Requirement will be met. [FR17]2 above 105°F or chilled fluids ❑Does Not below 55 °F are insulated to>_R- ['Not Observable Location on plans/spec: ',',4) 3. Mechanical Notes ❑Not Applicable 403.4.1 ;Protection of insulation on HVAC - '`41 � ` ❑Complies Requirement will be met. [FR24]1 piping. fl: ,. °` �❑Does Not Location on plans/spec: 43', ❑Not Observable Mechanical Notes ❑Not Applicable 403.5.3 ;Hot water pipes are insulated to R- R- ❑Complies Requirement will be met. [FR18]2 I>_R-3. ❑Does Not k'g?, I ❑Not Observable Location on plans/spec: ❑Not Applicable Mechanical Notes 403.6 Automatic or gravity dampers are r '� r s■Complies Requirement will be met. [FR19]2 installed on all outdoor air " •Does Not intakes and exhausts. �' " w ,- "..S 5 Location on plans/spec: ■Not Observable Mechanical Notes "` ,r ` ... , ,; Not Applicable 1 High Impact(Tier 1) 2l Medium Impact(Tier 2) 3. Low Impact(Tier 3) Project Title: Rhein Residence Report date: 05/30/18 ' Data filename: C:\Users\Authorized User\Documents\Gionta\Rhein\REScheck.rck Page 4 of 9 Additional Comments/Assumptions: 1 High Impact(Tier 1) Medium Impact(Tier 2) 34 Low Impact(Tier 3) Project Title: Rhein Residence Report date: 05/30/18 Data filename: C:\Users\Authorized User\Documents\Gionta\Rhein\REScheck.rck Page 5 of 9 Section Plans Verified '-Field Verified # Insulation Inspection Value Value ,Complies? • Comments/Assumptions & Req.ID �. 303.1 lAll installed insulation is labeled •.,, " DComplies Requirement will be met. [IN13]2 i or the installed R-values ti.... �� * ❑Does Not 4- 'provided. , .91 u ! Not Observable �M!" , ". ❑Not Applicable 402.1.1, :Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 i ❑ Wood ❑ Wood ❑Does Not table for values. [IN1]1 I ❑ Steel ❑ Steel [Not Observable I ❑Not Applicable 303.2, ;Floor insulation installed per ❑Complies Requirement will be met. 402.2.7 ':manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the '` - Location on plans/spec: j underside of the subfloor, or floor ❑Not Observable Detailed wall sections 4'< r❑Not A licable :framing cavity insulation is in -`, ' > PP •contact with the top side of -'__ ,.. :sheathing, or continuous insulation is installed on the :underside of floor framing and s i extends from the bottom to the ;top of all perimeter floor framing * q ,, ;members. 402.1.1, I Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, I mass wall with at least Y2 of the ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.6 ;wall insulation on the wall ❑ Mass ❑ Mass ❑Not Observable [IN3]1 ;exterior,the exterior insulation requirement applies(FR10). ❑ Steel 1] Steel ❑Not Applicable 303.2 I Wall insulation is installed per ❑Complies Requirement will be met. [IN4]1 I manufacturer's instructions. fv ❑Does Not I k ❑Not Observable Location on plans/spec: ❑Not Applicable Detailed wall sections Additional Comments/Assumptions: • 1 High Impact(Tier 1) Medium Impact(Tier 2) -•34;Low Impact(Tier 3) Project Title: Rhein Residence Report date: 05/30/18 Data filename: C:\Users\Authorized User\Documents\Gionta\Rhein\REScheck.rck Page 6 of 9 e Section Plans-Verified Field Verified # Final Inspection Provisions complies? Commerrt, Assumptions- Value Value 402.1.1, ;Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, ; ❑ Wood ❑ Wood ❑Does Not table for values. 402.2.2, ❑ Steel ❑ Steel ['Not Observable 402.2.6 [FI1]1 ; ❑Not Applicable 303.1.1.1,;Ceiling insulation installed per _,; ❑Complies Requirement will be met. 303.2 manufacturer's instructions. ❑Does Not [FI2]1 Blown insulation marked every -1> �" w Location on plans/spec: 300 ft2. � c❑Not Observable Detailed wall sections ° "- ' .y< -❑Not Applicable 402.2.3 Vented attics with air permeable > , ," >"- ----t ❑Complies Requirement will be met. [FI22]2 I insulation include baffle adjacent - ❑ s'- Does Not . Ito soffit and eave vents that '.=�� Location on plans/spec: ;extends over insulation. ❑Not Observable Detailed wall sections ❑Not Applicable 402.2.4 ;Attic access hatch and door R- R- DComplies Requirement will be met. [FI3]1 ;insulation?..R-value of the ❑Does Not I adjacent assembly. Location on plans/spec: ❑Not Observable Door Schedule ❑Not Applicable 402.4.1.2 ;Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50= ❑Complies Requirement will be met. [FI17]1 ;ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. Location on plans/spec: ['Not Observable Mechanical Notes ❑Not Applicable 403.2.3 j Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies Requirement will be met. [FI4]1 ;cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air ❑Not Observable Location on plans/spec: handler @ 25 Pa. For rough-in Mechanical Notes ;tests,verification may need to ❑Not Applicable occur during Framing Inspection. 403.3.2 ;Ducts are pressure tested to cfm/100 cfm/100 ❑Complies Requirement will be met. [FI27]1 ;determine air leakage with ft2 ft2 ❑Does Not ;either: Rough-in test:Total ❑Not Observable Location on plans/spec: ;leakage measured with a Mechanical Notes ;pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including ;the manufacturer's air handler enclosure if installed at time of ;test. Postconstruction test:Total ;leakage measured with a pressure differential of 0.1 inch ;w.g. across the entire system ;including the manufacturer's air handler enclosure. 403.3.2.1 ;Air handler leakage designated ❑Complies Requirement will be met. [FI24]1 ;by manufacturer at<=2%of ❑Does Not design air flow. Location on plans/spec: ❑Not Observable ��. - Mechanical Notes ❑Not Applicable 403.1.1 Programmable thermostats K ❑Complies Requirement will be met. [F19}2 ,installed for control of primary 7' " ' " ❑Does Not {heating and cooling systems and Location on plans/spec: initially set by manufacturer to _ :` Not Observable Mechanical Notes I code specifications. ❑Not Applicable 403.1.2 I Heat pump thermostat installed ❑Complies Exception: Requirement is [FI10]2 ion heat pumps. ❑Does Not not applicable. -a41 2, ❑Not Observable n ❑Not Applicable 403.5.1 Circulating service hot water ,, "''❑Complies Exception: Requirement is [Fill]2 systems have automatic or ❑Does Not not applicable. accessible manual controls. -❑Not Observable 4,"".' ,❑Not Applicable 1 High Impact(Tier 1) 2l Medium Impact(Tier 2) "'31 Low Impact(Tier 3) Project Title: Rhein Residence Report date: 05/30/18 Data filename: C:\Users\Authorized User\Documents\Gionta\Rhein\REScheck.rck Page 7 of 9 4 1 :: :: ct Plans Verified Field Verified # Final Inspection Provisions value Value Complies? Comments/Assumptions 403,6.1 All mechanical ventilation system 3 .-- •Complies Requirement will be met. [FI2512 fans not part of tested and listed -' „ ■Does Not 1 HVAC equipment meet efficacy ` Location on plans/spec: and air flow limits. ... . sry•Not Observable r•Not Applicable Mechanical Notes 403.2 Hot water boilers supplying heat - `, ■Complies Requirement will be met. [FI26]2 through one-or two-pipe heating ':' "'`'" ■Does Not systems have outdoor setback z Location on plans/spec: control to lower boiler water - ' "•"•Not Observable Mechanical Notes temperature based on outdoor , `■Not Applicable temperature. "; - 403.5.1.1 II H-. -. i.. - .I- . . - _ ❑Complies Requirement will be met. [F128]2 !have a circulation pump.The ' ❑Does Not system return pipe is a dedicated Location on plans/spec: return pipe or a cold water supply' k ,,-,1:,..-------,. t. , Not Observable Mechanical Notes pipe.Gravity and thermos- T i❑Not Applicable syphon circulation systems are s r ' not present.Controls for E xxi ' circulating hot water system R - ` -- - - : pumps start the pump with signal !t . . for hot water demand within the "t . �;" occupancy.Controls :, I automatically turn off the pump •s -- . } - 4 when water is in circulation loop x 3 *` -' is at set-point temperature and '��' no demand for hot water exists > 403.5.1.2 Electric heat trace systems `.-s < terFo- ❑Complies Exception: Requirement is [F129]2 comply with IEEE 515.1 or UL ii,, F ❑Does Not not applicable. 515.Controls automatically adjust the energy input to the , � `" ' .7g,- ❑Not Observable heat tracing to maintain the - Utz„,:44eAo., * run,,,z,„.t.,, ❑Not Applicable desired water temperature in the piping. 403.5.2 ;Water distribution systems that �'" x ❑Complies Requirement will be met. [FI30]2 have recirculation pumps that "` K!# ❑Does Not pump water from a heated water ,-.. '` / ;� Location on plans/spec: 'supply i e back to the heated hti ❑Not Observable P p pipe Mechanical Notes water source through a cold :; ❑Not Applicable water supply pipe have a a *�� j demand recirculation water �' - -! system. Pumps have controls � � ' that manage operation of theWT. - " . I pump and limit the temperature �.-A- of the water entering the cold water piping to 104°F. r, 403.5.4 Drain water heat recovery units 1 F ar? "'' ❑Complies Requirement will be met. [FI31]2 tested in accordance with CSA s# - 3' ❑Does Not 11355.1. Potable water-side t :r Location on plans/spec: pressure loss of drain water heat3. ❑Not Observable Mechanical Notes recovery units< 3 psi fore.: ❑Not Applicable individual units connected to one ry,, or two showers. Potable water- • side pressure loss of drain water :; heat recovery units < 2 psi for ,� - 3 individual units connected to f.,,. - '�'� three or more showers. 404,1 175%of lamps in permanent " pi Comp Requirement will be met. [F1671 !fixtures or 75% of permanent _ 5� � ! ❑Does Not Mixtures have high efficacy lamps Location on plans/spec: ;Does not apply to low-voltage ; ,• :❑Not Observable Mechanical Notes lighting. 3❑Not Applicable 404.1.1 'Fuel gas lighting systems have 71 ' .Z " � �' ■Complies Requirement will be met. [F123]3 Ino continuous pilot light. •* `■Does Not 4 ! ■Not Observable Location on plans/spec: I � * Mechanical Notes �� r.■Not Applicable 1 High Impact(Tier 1) Li Medium Impact(Tier 2) ;3§" Low Impact(Tier 3) Project Title: Rhein Residence Report date: 05/30/18 Data filename: C:\Users\Authorized User\Documents\Gionta\Rhein\REScheck.rck Page 8 of 9 w � ` ` Section # Final Inspection P,pv�o"s p�nana'��u p�mvenneu Complies? commen�s / va��� Value x�sumpuons a�eq.|o ` 401.3 .cnmp|iancecem�catepos�n� OcnmpUes nequiem�twmucme� [p|7]^ - []Does Not / O Not Observable | Not Applicable yo�.� �an���o��mnnua|sfor El Complies nequinem�twiUbeme� [R18]3 mechanical and water heating Does Not systemshavebeenpmvided. | OwutUbsemab|e � []NotApp|icob|e Additional Comments/Assumptions: ' z High Impact(Tier 1) Medium Impact(Tier z) Low Impact(Tier s) Project Title: Rhein Residence Report date: 05/30/18 Data filename: CAUaers\AuthohzedUser\Documents\Gionta\Rhain\RE5check.rck Page 9of 9 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 19.00 Below-Grade Wall 0.00 Floor — 38.00 Ceiling/ Roof 49.00 Ductwork(unconditioned spaces): Glass&Door Rating U-Factor SHGC Window 0.30 Door 0.30 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments