insulation report El Cr� c� zero APR 3 Oil 2019a � The Foam Guys- Spray foam Solutions TOWN OF QUEENSBURY p Y BUILDING&CODES April 2, 2019 DEPTH REPORT 'LEASE NOTE: This document is intended for the use of NY State Building Ind Code .requirements. PROJECT: 147 Chestnut Ridge Queensbury NY SIGNEE: George Rhein 914-522-2005 Roof Flats(Open Cell) RValue(67.5) Depth(15 inches) Exterior Walls(Open Cell) RValue(24.75) Depth(5.5 inches) Rim/Band Joist(Open Cell) RValue(31 .5) Depth(7 inches) Garage Walls(Open Cell) RValue(24.75) Depth(5.5 inches) Garage Ceiling(Open Cell) RValue(31 .5) Depth(7 inches) Bonus Room Walls(Open Cell) RValue(24.75) Depth(5.5 inches) Bonus Room Slopes(Open Cell) RValue(49) Depth(11 inches) 698 Route 29 !477-330-FOA °M Saratoga Springs 518-932 2989 New York 12866 nsciald©ncfr arnguyskyahoo corn zero The Foam Guys Spray For S thiti cns I, Nick Sciald . • :/Owner, st. - these RValues and Depths are correct. 4/10/19 Nick ' done Date 698 Route 29 1-877-33O FOAN Saratoga Springs 518 932-2989 New York 12866 nscialdaucfbamguys vakoa.cam EsICCEVALUATiON Most Widely Accepted and Trusted SERVICE �. Innovation RESEARCH LABS ICC-ES Evaluation Report ESR-2600 ICC-ES I (800) 423-6587 I (562) 699-0543 I www.icc-es.org Reissued 02/2018 This report is subject to renewal 02/2019. DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 07 2100—THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC. 3315 EAST DIVISION STREET ARLINGTON,TEXAS 76011 EVALUATION SUBJECT: AGRIBALANCE® SPRAY FOAM INSULATION ICC ICC ICC ILPMG LISTED 1w,\. "2014 Recipient of Prestigious Western States Seismic Policy Council SUR NTERNATIONAL (WSSPC)Award in Excellence" A Subsidiary of CODECOIINCIr ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. ANSI There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this ACCREDITED ISOlIEC 77066 report, or as to any product covered by the report. Product/1EC 17065 Body #1000 Copyright©2018 ICC Evaluation Service, LLC. All rights reserved. isICC EVALUATION SERVICE �,� .'.°^ Most Widely Accepted and Trusted ICC-ES Evaluation Report ESR-2600 Reissued February 2018 Revised May 2018 This report is subject to renewal February 2019. www.icc-es.orq 1 (800)423-6587 I (562)699-0543 A Subsidiary of the International Code Council® DIVISION:07 00 00—THERMAL AND MOISTURE construction under the IBC and dwellings under the IRC. PROTECTION The insulation is for use in wall cavities, floor assemblies, Section:07 21 00—Thermal Insulation roof/ceiling assemblies or attics and crawl spaces when installed in accordance with Section 4.4. Under the IRC, REPORT HOLDER: the insulation may be used as air-impermeable insulation when installed in accordance with Section 3.4. DEMILEC(USA)INC. 3.0 DESCRIPTION 3315 EAST DIVISION STREET ARLINGTON,TEXAS 76011 3.1 General: (817)640-4900 ® i www.demiiecusa.c®t1� Agribalance® s a spray-applied, semi-rigid, low- density, cellular polyurethane foam plastic that is installed as a EVALUATION SUBJECT: nonstructural component of floor/ceiling and wall assemblies. The material is a two-component, open-cell AGRIBALANCE®SPRAY FOAM INSULATION spray-applied polyurethane foam plastic system. The product is a water-blown foam with nominal density 1.0 EVALUATION SCOPE of 0.7 pcf(11.2 kg/m) and installed density of 0.6-0.8 pcf (9.6 - 12.8 kg/m )_ The polyurethane foam is produced 1.1 Compliance with the following codes: in the field by combining a polymeric isocyanate • 2018, 2015, 2012 and 2009 International Building (component A) and a year, (component B). The products Code®(IBC) have a shelf life of one when stored in factor sealed containers at temperatures between 50°F and 100°F • 2018, 2015, 2012 and 2009 International Residential (10°C and 38°C). Code®(IRC) Agribalance® spray foam insulation is an in 2018, 2015, 2012 and 2009 International Energy air-impermeable insulation in accordance with 2018 IBC Conservation Code®(IECC) Section 1202.3(2015 IBC Section 1203.3)and 2018, 2015 • 2013 Abu Dhabi International Building Code(ADIBC)t and 2012 IRC Section R806.5[2009 IRC Section R806.4], based on testing in accordance with ASTM E283. tThe ADIBC is based on the 2009 IBC.2009 IBC code sections referenced in this report are the same sections in the ADIBC. The attributes of the insulation have been verified as III Other Codes(see Section 8.0) conforming to the provisions of ICC 700-2008 Section 703.2.1.1.1(c) as an air impermeable insulation. Note that Properties evaluated: decisions on compliance for those areas rest with the user of this report. The user is advised of the project-specific a Surface-burning characteristics provisions that may be contingent upon meeting specific ■ Physical properties conditions, and the verification of those conditions is outside the scope of this report. These codes or standards ■ Thermal resistance often provide supplemental information as guidance. • Attic and crawl space installation 3.2 Surface-burning Characteristics: ■ Air permeability The insulation at a maximum thickness of 5.5 inches 1.2 Evaluation to the following green standard: (139.7 mm) and a density of 0.6 pcf (9.6 kg/m3), has a flame-spread index of less than 25 and smoke-developed 2008 ICC 700 National Green Building StandardT'" index of less than 450 when tested in accordance with (ICC 700-2008) ASTM E84(UL 723).There is no thickness limitation when Attributes verified: installed behind a code-prescribed 15-minute thermal barrier complying with, and installed in accordance with, See Section 2.0 IBC Section 2603.4 or IRC Section R316.4,as applicable. 2.0 USES 3.3 Thermal Resistance,R-values: Agribalance® spray foam insulation is used as a The insulation has thermal resistance,R-values,at a mean nonstructural thermal insulating material in Type V-B temperature of 75°F(24°C), as shown in Table 1. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not spectcally addressed nor are they to be construed pNs� as an endorsement of the subject of the report or a recommendation for its use.There is no warranty by ICC Evaluation Service,LLC,express or implied,asIII to any finding or other matter in this report,or as to any product covered by the report. Copyright©2018 ICC Evaluation Service,LLC. All rights reserved. Page 1 of 4 ESR-2600 I Most Widely Accepted and Trusted Page 2 of 4 3.4 Air Permeability: There is no thickness limitation when installed behind a Agribalance® spray-applied polyurethane foam insulation, code-prescribed 15-minute thermal barrier. at a minimum of 3.5 inches (89 mm), is considered 4.3.2 Application without a Prescriptive Thermal air-impermeable insulation in accordance with 2018 IBC Barrier: Agribalance® spray foam insulation may be Section 1202.3 [2015 IBC Section 1203.3] and 2018, 2015 installed without the prescriptive 15-minute thermal barrier and 2012 IRC Section R806.5 (2009 IRC Section R806.4) described in Section 4.3.1 when installation is in based on testing in accordance with ASTM E283 and accordance with the following: ASTM E2178. 4.3.2.1 The insulation must be covered on all surfaces 3.5 BlazelokTM IB4 Intumescent Coating: with a fire protective coating at the minimum thickness set BlazelokTM IB4 intumescent coating, manufactured by forth in Table 2. TPR2 Corporation, is a one-component,water-based liquid 4.3.2.2 The maximum installed thickness of the insulation coating. BlazelokTM IB4 is supplied in 5-gallon (19 L) pails must not exceed the thickness set forth in Table 2. and/or 55-gallon (208 L) drums and has a shelf life of one 4.3.2.3 The coating must be applied over the insulation in (1) year when stored in factory-sealed containers at accordance with the coating manufacturer's instructions temperatures between 45°F(7°C)and 90°F(32°C). and this report. 3.6 Blazelokn"TBX Intumescent Coating: 4.4 Attics and Crawl Spaces: BlazelokTM TBX Coating, manufactured by TPR2 4.4.1 Application with a Prescriptive Ignition Barrier: Corporation (ESR-3997), is a one-component,water-based When Agribalance® insulation is installed within attics or liquid-applied intumescent coating. BlazelokT'" TBX is crawl spaces where entry is made only for service of supplied in 5-gallon (19 L) pails and 55-gallon (208 L) utilities, an ignition barrier must be installed in accordance drums and has a shelf life of one (1) year when stored in with IBC Section 2603.4.1.6 or IRC Sections R316.5.3 factory-sealed containers at temperatures between 45°F and R316.5.4, as applicable. The ignition barrier must be (7.2°C)and 95°F(35°C). consistent with the requirements for the type of 3.7 DC 315 Coating: construction required by the applicable code, and must be installed in a manner so the foam plastic insulation is not DC 315 Coating (ESR-3702), manufactured by exposed. Agribalance® insulation as described in this International Fireproof Technology, Inc., / Paint to Protect, section may be installed in unvented attics in accordance Inc. is a water-based intumescent coating supplied in with 2018 IBC Section 1202.2 (2015 IBC Section 1203.3) 5-gallon (19L) pails and 55-gallon (208L) drums. The or 2018, 2015 and 2012 IRC Section R806.5 (2009 IRC coating material has a shelf life of one (1) year when Section R806.4). stored in factory-sealed containers at temperatures between 50°F(10°C)and 80°F(27°C). 4.4.2 Application without a Prescriptive Ignition Barrier: 4.0 DESIGN AND INSTALLATION 4.4.2.1 General: Where Agribalance® insulation is 4.1 General: installed without a prescriptive ignition barrier in attics and Agribalance® spray foam insulation must be installed in crawl spaces in accordance with Sections 4.4.2 and 4.4.3, accordance with the manufacturer's published installation the following conditions apply: instructions and this report. A copy of the manufacturer's a. Entry to the attic or crawl space is only to service published installation instructions must be available at all utilities and no storage is permitted. times on the jobsite during installation. b. There are no interconnected attic or crawl space 4.2 Application: areas. The insulation is spray-applied on the jobsite using a c. Air in the attic or crawl space is not circulated to other volumetric positive displacement pump as identified in parts of the building. the Demilec application manual. The insulation can be installed in one pass to the maximum thickness as d. Attic ventilation is provided when required by 2018 specified in Sections 3.2 and 4.4.2. The foam plastic must IBC Section 1202.2.1 [2015, 2012 and 2009 IBC not be used in electrical outlet or junction boxes or in Section 1203.2] or IRC Section R806, except when contact with rain, water, or soil. The foam plastic must not air-impermeable insulation is permitted in unvented be sprayed onto a substrate that is wet, or covered with attics in accordance with 2018 IBC Section 1202.3 frost or ice, loose scales, rust, oil, or grease. Agribalance® [2015 IBC Section 1203.3] or 2015 and 2012 IRC resin (component B) must be stored in areas where Section R806.5(2009 IRC Section R806.4). the ambient temperature is between 50°F and 100°F e. Under-floor(crawl space)ventilation is provided when (10°C and 38°C). Agribalance® must be used in areas required by 2018 IBC Section 1202.4 [2015 IBC where maximum ambient temperature is equal or less than Section 1203.4 (2012 and 2009 IBC Section 1203.3)] 180°F (82°C). The insulation must be protected from the or IRC Section R408.1,as applicable. weather during and after application. f. Combustion air must be provided in accordance with 4.3 Thermal Barrier: International Mechanical Code®(IMC)Section 701. 4.3.1 Application with a Prescriptive Thermal Barrier: 4.4.2.2 Application with Blazelokn" IB4 Coating: In Agribalance® spray foam insulation must be separated attics, Agribalance®insulation may be spray-applied to the from the interior of the building by an approved thermal underside of roof sheathing and/or rafters; and the barrier of/2-inch-thick (12.7 mm) gypsum wallboard or an underside of wood floors and/or floor joists in crawl spaces equivalent 15-minute thermal barrier complying with, and as described in this section. The thickness of the foam installed in accordance with, IBC Section 2603.4 or IRC plastic applied to the underside of the wood floor and roof Section R316.4, as applicable, except when installation is sheathing must not exceed 111/4 inches (286 mm). The in attics and crawl spaces, as described in Section 4.4. spray foam insulation applied to vertical wall surfaces in ESR-2600 I Most Widely Accepted and Trusted Page 3 of 4 attics and crawl spaces must not exceed 91/4 inches thicknesses noted in Sections 3.2, 4.4.2 and 4.4.3 of (235 mm) in depth. The foam plastic surface must be this report. covered with a minimum 5-dry-mil [9 wet mils (0.23 mm)] 5.5 The insulation must be protected from the weather N thickness of Blazelok IB4 intumescent coating as during and after application. described in Section 3.5.The intumescent coating must be spray-applied over the insulation in accordance with the 5.6 The insulation must be applied by contractors coating manufacturer's instructions and this report at a rate authorized by Demilec USA. of 1 gallon (3.38 L) per 175 square feet(16.3 m2)to obtain 5.7 Use of the insulation in areas where the probability the recommended minimum dry film thickness noted in this of termite infestation is "very heavy" must be in section. Surfaces to be coated must be dry and clean, and accordance with IRC Section R318.4 or IBC Section free of dirt, loose debris and any other substances that 2603.8,as applicable. could interfere with adhesion of the coating. 5.8 The insulation has been evaluated only for use in 4.4.2.3 Application with DC 315 Coating: In attics, Type V-B construction under the IBC and non-fire- Agribalance foam insulation may be spray-applied to the resistance rated assemblies in dwellings under the underside of the roof sheathing and/or rafters and in crawl IRC. spaces. The insulation may be spray-applied to the 5.9 Jobsite certification and labeling of the insulation must underside of wood floors as described in this section. The comply with 2018 or 2015 IRC Sections N1101.10.1 thickness of the foam plastic applied to the underside of and N1101.10.1.1 (2012 IRC Sections N1101.12.1 the top of the space must not exceed 111/2 inches and N1101.12.1.1 or 2009 IRC Sections N1101.4 and (292 mm),l and the thickness on vertical surfaces must not N1101.4.1)]and 2018, 2015 and 2012 IECC Sections exceed 7/2 inches (191 mm). The foam plastic surface C303.1.1, C303.1.1.1, R303.1.1 and R303.1.1.1 must be covered with a minimum nominal thickness of (2009 IECC Sections 303.1.1 and 303.1.1.1), as 3 dry mils (0.08 mm)[4 wet mils(0.10 mm)]of the DC 315 applicable. coating described in Section 3.6. The intumescent coating must be spray-applied over the insulation in accordance 5.10 A vapor retarder must be installed when required by with the coating manufacturer's instructions and this report the applicable code. at a rate of 1 gallon (3.38 L) per 401 square feet(373. m2) 5.11 The insulation is produced in Arlington, Texas and to obtain the recommended minimum dry film thickness Boisbriand, Quebec, Canada, under a quality control noted in this section. Surfaces to be coated must be dry program with inspections by ICC-ES. and clean, and free of dirt, loose debris and any other 6.0 EVIDENCE SUBMITTED substances that could interfere with adhesion of the coating. 6.1 Data in accordance with ICC-ES Acceptance Criteria 4.4.3 Use on Attic Floors: Agribalance® spray-applied for Spray-applied Foam Plastic Insulation (AC377), dated April 2016 (editorially revised April 2018), insulation may be installed exposed at a maximum thickness of 71/2 inches (191 mm) between and over the including testing in accordance with Appendix X. joists in attic floors,when covered with the DC 315 coating 6.2 Reports of room corner fire tests in accordance with described in Section 4.4.2.3. Agribalance® spray-applied NFPA 286. insulation may be installed exposed at a maximum 6.3 Reports of air leakage tests in accordance with ASTM thickness of 5/2 inches (140 mm) between and over the E283. joists in attic floors,when covered with the BlazelokTm TBX 6.4 Reports of air permeance tests in accordance with intumescent coating described in Section 4.4.2.2. The ASTM E2178. insulation must be separated from the interior of the building by an approved thermal barrier. The ignition 7.0 IDENTIFICATION barrier in accordance with IBC Section 2603.4.1.6 and IRC Components of Agribalance® spray foam insulation are Section R316.5.3 may be omitted. identified with the manufacturer's name (Demilec USA), 5.0 CONDITIONS OF USE address and telephone number; the product trade name ® (Agribalance®); use instructions; the density; the flame- The Agribalance®spray-applied foam insulation described spread and smoke-development indices; and the in this report complies with, or is a suitable alternative to evaluation report number(ESR-2600). what is specified in, those codes listed in Section 1.0 of BlazelokTM this report,subject to the following conditions: Each pail of Blazelok IB4 intumescent coating is labeled with the manufacturer's name (TPR Corporation), 5.1 This evaluation report and the manufacturer's the product name and use instructions. published installation instructions, when required by Blazelok TBX coating is labeled with the manufacturer's the code official, must be submitted at the time of name and address; the product name; the date of permit application. manufacture, the shelf life or expiration date; the 5.2 The products must be installed in accordance with the manufacturer's instructions for application and evaluation manufacturer's published installation instructions, this report number(ESR-3997). evaluation report and the applicable code. The International Fireproof Technology, Inc./Paint to Protect instructions within this report govern if there are any Inc., DC 315 coating is labeled with the manufacturer's conflicts between the manufacturers' published name and address; the product name; the date of installation instructions and this report. manufacture, the shelf life or expiration date; the 5.3 The insulation must be separated from the interior of manufacturer's instructions for application and evaluation the building by an approved 15-minute thermal report number(ESR-3702). barrier, except when installation is as described in 8.0 OTHER CODES Section 4.3.1 or in attics and crawl spaces as In addition to the codes referenced in Section 1.0, the described in Section 4.4. products described in this report have been evaluated in 5.4 The insulation must not exceed the density and accordance with the following codes: ESR-2600 I Most Widely Accepted and Trusted Page 4 of 4 • 2006 International Building Code®(2006 IBC) the 2006 and 2003 IBC or Section R408 of the 2006 and • 2006 International Residential Code®(2006 IRC) 2003 IRC, as applicable. Additionally, an ignition barrier must be installed in accordance with Section R314.5.3 • 2006 International Energy Conservation Code® (2006 or R314.5.3 of the 2006 IRC or Section R314.2.3 of the IECC) 2003 IRC,as applicable. • 2003 International Building Code®(2003 IBC) ■ Application without a Prescriptive Ignition Barrier: • 2003 International Residential Code®(2003 IRC) See Section 4.4.2, except attics must be vented in accordance with Section 1203.2 of the 2006 and 2003 • 2003 International Energy Conservation Code® IBC or Section R806 of the 2006 and 2003 IRC, and (2003 IECC) crawl space ventilation must be in accordance with The products comply with the above-mentioned codes as Section 1203.3 of the 2006 and 2003 IBC or Section described in Sections 2.0 through 7.0 of this report, with R408 of the 2006 and 2003 IRC,as applicable. the revisions noted below: ■ Protection against Termites: See Section 5.7, except • Application with a Prescriptive Thermal Barrier: See use of the insulation in areas where the probability of Section 4.3, except the approved thermal barrier must termite infestation is "very heavy must be in be installed in accordance with Section R314.4 of the accordance with Section R320.5 of the 2006 IRC or 2006 IRC or Section R314.1.12 of the 2003 IRC. Section R320.4 of the 2003 IRC. • Application with a Prescriptive Ignition Barrier: See • Jobsite Certification and Labeling: See Section 5.9, Section 4.4.1, except attics must be vented in except jobsite certification and labeling must comply accordance with Section 1203.2 of the 2006 and 2003 with Sections 102.1.1 and 102.1.11, as applicable, of IBC or Section R806 of the 2003 IRC, and crawl space the 2006 IECC. ventilation must be in accordance with Section 1203.3 of TABLE 1—THERMAL RESISTANCE(R VALUES) THICKNESS(INCH) 12-VALUE'(°F.ft2.h/Btu) 1 4.5 2 8.9 3 13 3.5 16 4 18 5.5 24 6 27 7.5 33 9.25 41 9.5 42 10 44 11.25 50 11.5 51 14 62 For SI:1 inch=25.4 mm;1°F.ft.h/Btu=0.176110°K.m2/W. 'R-values are calculated based on tested K values at 1-and 4-inch thicknesses. TABLE 2—USE OF INSULATION WITHOUT A PRESCRIPTIVE THERMAL BARRIER(TESTED IN ACCORDANCE WITH NFPA 286)1 INSULATION MAXIMUM MAXIMUM COATING TYPE&MINIMUM MINIMUM APPLICATION TYPE THICKNESS(in.) THICKNESS(in.) THICKNESS(Applied to all RATE OF COATING (Vertical Surfaces) (Overhead Surfaces) Foam Surfaces)2'3 Blazelok TBX Agribalance® 51/2 111/2 15 mils DFT 1.23 gal/100 ft2 23 mils WFT DC 315 Agribalance® 71/2 111/2 12 mils DFT 1.25 gal/100 ft2 18 mils WFT For SI:1 inch=25.4 mm;1 mil=0.0254 mm;1 gallon=3.38 L;1 ft2=0.093 m2. Notes: 'See Section 4.3.2. 2See Section 3.6 and 3.7. 3DFT=Dry Film Thickness;WFT=Wet Film Thickness