Loading...
revisions REVIEWED FOR ENERGY CODE COMPLIANCE hcFILE COPY - 02±)2- 24�� architects July 12, 2019 Mr.John O'Brien Town of Queensbury Building Department �' 742 Bay Road Queensbury, New York 12804 Re:Addictions Care Facility Veel5 Y Queensbury, New York 12804 1G� es 79 Glenwood Avenue V o1NG��d� Dear Mr. O'Brien, In response to your e-mail regarding the Change in Scope of Work at Addiction Care Center we offer the following: We have reached out to the Department of State Code Division and they advised us to forgo the use of CornCheck and instead use the U Values requirements listed in the Energy Code. Using Table C402.1.4 Walls Walls, above grade Climate Zone 6 I-1 Occupancy The Maximum U Factor is 0.051 Our U Value is 0.033 Exceeds requirements Wall insulation consists of: • 1%:"Closed Cell Spray Foam insulation R.6 per inch • R21 Batt Insulation Roofs Climate Zone 6 I-1 Occupancy The Maximum U Factor is 0.021 Our U Value is 0.0204 Our Attic insulation consists of R49 batt insulation Exceeds requirements James P.Coleman,AIA Joseph M.Riley,AIA,LEED AP Benjamin J.Nassivera,AIA,LEED AP HCP Architects, LLP • 302 Washington Avenue Extension • Albany, New York 12203 • p: 518.218.0614 • www.hcpdesign.com r � Windows The replacement Windows are prescribed in Table C402.4 Climate Zone 6 Maximum U-factor allowable ....Operable windows Max U= 0.43 ACTUAL U. 0.30 Exceeds requirements SHGC Maximum SHGC 0.40 ( PF<0.2) ACTUAL SHGC 0.28 Exceeds requirements Doors Climate Zone 6 Entrance Doors shall be insulated Hollow Metal Doors Maximum U-FACTOR 0.77 Actual 0.16 Exceeds requirements All envelope components meet or exceed the Code minimums. We have also attached a cross section of the building indicating the R values of the insulation. Air Sealing and a Blower test will be performed CamRoden Associates will be the agency entrusted with the blower test. Air sealing will be done prior to insulation. Should you have any concerns or questions please contact our office. Sincerely, es Coleman cc. Greg Youmans BBL Construction Services LLC Encl. r \ Andersen. • ,,i , _ , , Sao SERIES SINGLE-HUNG WINDOWS sty. . Andersen® 100 Series single-hung windows allow ventilation i• r I , '' ' :�,e - y 3 thr ough a single operable lower sash that slides up and 4' 1 1 . down. Classic rectangular shapes are available, or use an °' _ : i I'', arched top for added elegance. Made with our revolutionary i i, ,. i Fibrex®composite material, 100 Series products are durable, t i i,� environmentallysmart and energyefficient. 100 Series f = i I -_ ti`< rrr,,,, �_ i ' t products are available in deep, rich colors that complement -., virtually any architectural style. For added style, we offer a i i wide range of grille patterns and patterned glass options. ;.A~m 1 1 ' DURABLE om • Virtually maintenance-free k " • Rigorously tested to deliver years'of smooth, reliable operation • Fibrex material construction provides long-lasting' performance • Durable,low-maintenance finish won't fade,flake, blister or peel- 3 `r • Fibrex material is twice as strong as vinyl \ ENERGY EFFICIENT • Weather-resistant construction for greater comfort and energy efficiency • Weatherstripping is designed to seal out drafts,wind and water • Variety of Low-E glass options are available to help controlthatmake heatingthem and ENERGY cooling costsSTARS v.in 6any.0 climatecertified x It •Many 100 Series casement windows have options ASK ABOUT j E sr:rA�GY throughout the U.S. BEAUTIFUL • Clean,attractive corner seams • Five exterior color options 1111 • Attractive matte finish interiors available in four colors • Add style with grilles or patterned glass EXTERIOR COLORS White Sandtone Terratone Dark Bronze Black "Vsit andandersenvandows.comMairtanly for details. CUSTOM SIZES 'ENERGY STAR'is a registered trademark of the US.Environmental Protection Agency. 100 SERIES SINGLE-HUNG WINDOWS Fibre0 material combines the strength and durability of INTERIOR OPTIONS wood with the low-maintenance of vinyl.The wood fibers are reclaimed from our own factories,which makes this product sustainable and environmentally responsible. III HIGH-PERFORMANCE GLASS OPTIONS White Sandtone' Dark Bronze' Black • Low-E glass • Low-E glass with HeatLock°technology HARDWARE • Low-E Sun glass Single-hung windows feature • Low-E SmartSun'glass I hardware that automatically locks • Low-E SmartSun glass with HeatLock technology when windows are closed Hardware Tempered glass and other glass options are available.Contact color matches the window's interior. your Andersen supplier. Optional lift handle matches the • window's interior. PATTERNED GLASS New metal Slim Line hardware is Ideal for letting light into the home while obscuring vision. available in White,Sandtone,Dark Available in four attractive patterns. 111111111111110 Bronze,Black,Satin Nickel and llg Ili. Dark Bronze Antique Brass. t , '� ' GRILLES q Obscure Cascade Reed Fern Choose from the following grille options: FRAME OPTIONS �' 0 1 3B flange setback, 1°flange setback with stucco key or r : % replacement configuration. ADDITIONAL FEATURES /' • Sash lock engages automatically when operable sash Fine6ght"Grilles- Finelight with Full Divided Simulated Between-the-Glass Exterior Gilles light Divided Light is closed _.� �.,_.. • Operable sash has a meeting stile cover with a unique All grille options are available in a variety of patterns. raised profile design,allowing the sash to be opened and closed easily111111 i 1 mit xi ®I F . 1 x �:. Colonial Prairie A Tall Specified Sunburst" Fractional Equal Light (2x 21 WINDOWS•DOORS "Units with Black.Dark Bronze and Sandtone interiors have matchehgexteriors. n JENA "Sunburst pattern irony available wah Fnelight griles. Printing limitations prevent exact color and finish duplication.See your Andersen supplier for actual finish samples. For more information or to find a dealer,visit "Andersen"and all other marks where denoted are trademarks of Andersen Corporation. 02018 Andersen Corporation.All rights reserved.07!18 andersenwindows.com/100series or call 877.577.7655. Line Item#: 0001 Line Item Qty: 44 Initial: Location: RO Size=3'1 1/2"W x 5'9 1/2"H Unit Size=3'1"W x 5'9"H 100 Series, 100SHS Single Units Unit Code/Item Size: 100SHS3' 1"x 5'9"(Custom) Operation/Handing:F/A Window Opening Control Device: Factory Applied,White, Left Frame Option: No Flange Exterior Color: White Interior Color: White Glass Type(Top): Low E Glass, Finelight Grilles-Between-the-Glass, Specified Equal Lite,White/White,3/4" Viewed from Exterior Glass Type(Bottom): Low E Glass,Finelight Grilles-Between-the-Glass,Specified Equal Lite,White/White,3/4" Grille Construction (Top/Bot):Finelight Grilles-Between-the-Glass/Finelight Grilles-Between-the-Glass Custom Lite Pattern(Top):4w2h Custom Lite Pattern(Bot):4w2h Insect Screens: Half Insect Screen,White Lock Hardware Style: Andersen 100 Series Lock Color:White Zone:Northern ‘\ U-Factor:0.30, SHGC:0.28, ENERGY STAR®Certified:No Comments: Qty Part Num Item Size Description 1 0000000 100SHS3' 1"x 5'9" Unit, No Flange, White/White, Low E Glass, Finelight Grilles-Between-the-Glass,Specified Equal Lite,4w2h,White/White, 3/4"(Each Sash),Half Insect Screen,White,WOCD(Factory Applied), Andersen 100 Series Hardware,White SUBMITTED BY: ACCEPTED BY: DATE: **All graphics as viewed from the exterior. **Rough opening dimensions are minimums and may need to be increased to allow for use of building wraps or flashings or sill panning or brackets or fasteners or other items. QUOTE: 110685 Print Date: 06/14/2019 Page 2 Of 3 iQ Version: 19.0 Thermal Performance CURRIES ASSA ABLOY Thermal Transmission Terms The following terms are used in describing thermal properties of building products: BTU-The BTU(British Thermal Unit)is the amount of heat needed to raise the temperature of one pound of water one degree Fahren- heit. The BTU is used to measure the amount of heat just as the inch or foot is used to measure length. K-Factor-The measure of thermal conductivity or amount of heat transferred(measured in BTU's)in one hour through one square foot of a single material which is one inch thick for a difference of one degree Fahrenheit between the two surfaces. THE LOWER THE"K" FACTOR the more effective the insulation of the material. U-Factor-The total or overall transmission of heat through a combination of materials assembly measured in BTU's per hour per square foot of area for a difference in temperature of 1°F between the air on one side to the air on the other side. THE LOWER THE"U"VALUE the more effective the insulation of the material. R-Factor-The resistance or ability to retard heat flow(as opposed to ability to transmit heat)of any single material determined by the reciprocal of its conductivity. R=1/U or t/K,where t is the thickness of the material involved. THE GREATER THE"R"FACTOR (or resistance),the more effective the insulation of the material. All"K"and"U"factor values are expressed in BTU's/hr-ft2°F(W/m2 K). Materials possessing low"K"and"U"factor values are more efficient insulators than those with higher values. Helpful conversion factors: "R"= „U„ = "K" (where t is the material thickness in inches and the products are of uniform composition) "U"= (Rx is for each material layer) R1+R2+,..+etc. Energy Efficient Solutions Similar to most other building products manufacturers,the Steel Door Institute has encouraged the practice of citing a calculated value for thermal performance of the cores in the doors(U and R Values).While this remains the industry standard,we are seeing more specs with the latest standards for thermal transmittance(ASTM C1363)and air infiltration(ASTM E283).Note,ASTM C1363 is the most current test standard for thermal transmittance and replaces ASTM C236. You will see significant differences between the calculated core values(ASTM C518)and the operable door assembly values as door and frame construction varies.Design professionals are beginning to see these variances in other building products such as wall partitions(an industry that has already begun to move from calculated to operable values).We believe it's important you and your cus- tomers understand the operable performance levels of the opening assemblies you purchase along with the calculated core values. Door Assembly Operable U-Factor and R-Value Ratings Air Infiltration Testing Test Method: Test Method: What is air infiltration? ASTM C518 ASTM C1363* Air infiltration:A measurement of the air leakage Door Series/Core Calculat-d O i erable around the perimeter of a door opening. U-Factor R-Value U-Factor R-Value CFM:Cubic Feet per minute 707/Polystyrene 0.16 • 0.37 2.7 Test Method:ASTM E283* ..+ ` Door Series/Core 707/Polystyrene Kerf 0.16 6.4 0.45 2.2 CFM I SQFT CFM I LN FT 607/Polystyrene 0.16 6.4 0.39 2.6 All CURRIES door construction with CURRIES Thermal Break 0.04 0.06 707/Polyurethane 0.10 10.0 0.35 2.9 Frame 777E(Trio-E)fPolyurethane 0.09 11.0 0.29 3.4 * Tested with hardware from other ASSA ABLOY Group brands including 777E(Trio-E)/Polyurethane Kerf 0.09 11.0 0.36 2.7 Corbin Russwin,Pemko,McKinney,Sargent and Yale in a CURRIES Thermal 707/Honeycomb NIA N/A 0.54 1.9 Break Frame 747/Fiberglass 0.15 6.8 0.55 1.8 NOTE:Information included in this data sheet is subject to revision without notification.